Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope, Go/No-Go checksEligibility, required documents, scope of work and Go/No-Go checks for this tender, in one click.
Tender Value
₹45.6 L
EMD Value
₹91,140
Closing Date
5 Dec 2026, 6:30 pm
Eligibility, documents, scope, Go/No-Go checksEligibility, required documents, scope of work and Go/No-Go checks for this tender, in one click.
GE AF SULUR
KANGAYAMPALAYAM
PROVISION OF RETROFIT EMISSION CONTROL DEVICES IN CERTAIN DG SETS, MOTION SENSOR LIGHTS AND ASSOCIATED MISC E/M WORKS AT AFS SULUR
2026_MES_798617_1
8932/E8
Open Tender
Miscellaneous Works
Item Rate
210 days
GE AF SULUR
please ref to tender documents
6 documents required · 6 mandatory
₹500
GE AF SULUR
₹91,140
Yes
13 Nov 2026
13 Nov 2026
7 Dec 2026
13 Nov 2026
5 Dec 2026
28 Nov 2026
14 Nov 2026 - 20 Nov 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Design, supply, installing, testing and commissioning of Retrofit Emission Control Device (RECD) for 40/45 KVA standby DG Sets as per lates GOI notification on retrofitting devices emission control and as per latest CPCB guideline and as directed by Engr-in-Charge. The technology involve in the device should be DPF (Diesel Particulate Filter) /wet scrubbing Diesel oxides catalyst or any other technology complete all as specified and as directed with following specifications.
(a) The Emission Control retrofit device shall be with corrosion resistive.
(b) Pollutant captured: PM 2.5 (CO and HC) emitting from Diesel engine with gauranteed reduction efficiency of 70%
(c) Anti-Vibration mountings shall be provided for complete emission control retrofit device in case of flexible coupling with the diesel generator exhaust.
(d) Back pressure: No adverse impact on engine.
(e) Material: Structural Mild steel, RECD: Stainless steel.
(f) If any damage caused to the DG Set is complete responsibility of the contractor to make it good. | 2 | EACH | - | - |
| 1.01 | (g) For DG sets up to 800KW the Retrofit Emission Control Devices (RECD) tested and are certified by one of the following recognized and approved agencies by the Central Pollution Control Board (CPCB) and as per the guideline of “System and Procedure for Emission Compliance Testing of Retro-fit Emission Control Device (RECD) for Diesel Power Generating Set Engines up to Gross Mechanical Power 800 KW issued by CPCB as follows:-
(i) Automotive Research Association of India (ARAI, Pune)
(ii) Internal Centre of Automotive Testing (ICAT, Manesar)
(iii) Indian Institute of Petroleum (IIP, Dehradun)
(iv) Vehicle Research Development Establishment (VRDE, Ahmednagar)
(v) Indian Oil Corporation, Research and Development Centre, Faridabad (Haryana).
(h) Retrofit emission control system should be as per NGT/ MoHUA recommendations to achieve minimum specified Particulate Matter, Carbon Monoxide, NO₂ and Hydrocarbon capturing efficiency is PM, CO, HC
(j) The emission must be tested over an ISO-8178 mode D2 cycle for equivalent in KVA rating having a minimum specified particulate matter Carbon Monoxide and Hydrocarbon reduction efficiency of atleast 70%
(k) Warranty shall be provided for 4000 Hours or 6 years whichever is earlier | - | - | - | - |
| 2 | All as per item No 1.00 here-in-before, but for 50KVA standby DG Sets | 2 | EACH | - | - |
| 3 | All as per item No 1.00 here-in-before, but for 63KVA standby DG Sets | 1 | EACH | - | - |
| 4 | All as per item No 1.00 here-in-before, but for 82.5KVA standby DG Sets | 1 | EACH | - | - |
| 5 | Material and labour for point wiring complete with 1.5 sqmm single core PVC insulated, unsheathed FRLSH 1100 volts grade, multi stranded with copper conductor drawn through and including PVC casing & capping along with accessories in wall/roof/ceiling etc and FRLSH 1.5 sqmm PVC insulated, unsheathed copper conductor multistranded cable 1100V grade as earth continuity conductor & connecting to common earth dolly for one light point/ fan/ bell point controlled by one switch.complete all as specified and as directed by Engr-in-Charge for the following:
Note:
Connection of wire with switch, socket shall be through copper thumble (lugs) only. | 82 | POINT | - | - |
| 6 | Supply and fix modular switch 1 way, 6 Amp, 1 module complete all as specified and as directed. | 82 | EACH | - | - |
| 7 | Supply and fix modular white cover plate with frame, 8 module complete all as specified and as directed. | 10 | EACH | - | - |
| 8 | Supply and fix plastic surface box, 8 module for mounting modular cover plates/ switches/ sockets (horizontal type) complete all as specified and as directed. | 10 | EACH | - | - |
| 9 | Supply, installation, testing and commissioning of high quality standalone integrated full diffuser LED 2'x2' 32W Recess mounted LED occupancy sensor luminare with system efficacy of 110 lumen per Watt, beam angle of 110 deg, voltage range of 140-240VAC, 50/60Hz, burning hours upto 50,000 hrs, IP 20 ingress protection, sensor detection range of 360 deg @ 3Mtr height max fixing, PIR type sensor, 100% dimmable on zero occupancy, CRI >80, CCT of 6500K/5700K , housing should be of high quality CRCA & PS diffuser, driver efficiency >90%, driver Surge protection not less than 3.5kV, PF>=0.95, Driver THD<10%. Product should be suitable for continuous operation (14-16) hrs per day complete all as specifed and as directed.
Make: Philips Cat Pat No. RC 383B P LED 36S-6500 G6 PSU OD WH PIR P or any equivalent make as given list of makes | 160 | EACH | - | - |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 0.33 MB
COMMON_PAGES_8932.pdf
Tender Documents • 0.54 MB
PS_8932.pdf
Tender Documents • 0.29 MB
BOQ_895947.xls
BOQ • 5.96 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .