Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹37.9 LAccepted-AOC SHOP NO 10 BMC SHOPPING CENTRE MITHA NAGAR GOREGAON WEST MUMBAI 400 104 | MUMBAI | MUMBAI SUBURBAN | MAHARASHTRA | 400104 | L1 | Accepted-AOC Being lowest tenderer | |
| 2 | L2₹73.0 L+₹34.4 L (89.0%)Rejected-Finance | L2 | Rejected-Finance Being other than lowest tenderer | |
| 3 | L3₹91.8 L+₹53.2 L (137.7%)Rejected-Finance | L3 | Rejected-Finance Being other than lowest tenderer |
Tender Value
Refer Docs
EMD Value
₹90,000
Closing Date
26 Dec 2020, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE (NW) KUNJALI
Dr Homibhabha Road, Colaba, Mumbai-400005
8305 REPAIR MAINT OF LT DISTRIBUTION NETWORK AT INS ANGRE INS AGANIBHAU INS KUNJALI ETC UNDER GE NW KUNJALI
2020_MES_399237_1
8305/E8
Open Tender
Civil Works
Item Rate
186 days
GE (NW) KUNJALI
Please refer tender documents
7 documents required · 7 mandatory
₹500
Yes
GE (NW) KUNJALI
₹90,000
Yes
23 Jan 2021
28 Nov 2020
28 Dec 2020
5 Dec 2020
26 Dec 2020
12 Dec 2020
28 Nov 2020 - 5 Dec 2020
60 days
Amount
Supply, fabrication, installation, testing & commissioning of LT Panel board / Feeder piller box, in door type, dust and vermin proof, made out of 2mm thick CRCA sheet, front & back openable doors having aluminium bus bar of capacity 1000 amps for phases and 500 amps for neutral including powder coated painting, internal wiring with suitable size of stranded copper conductor cable, PCC foundation, supporting channels,cable termination,cable gland etc complete at Drill shead including taking down old panel all as directed and suitable to accommodate the following switch gears and meters :- a) MCCB 630Amps 4pole,65 KA,Thermal magnetic - 1 Nos (Incomer) b) MCCB, 3 pole 200 Amps,37KA,Thermal magnetic - 7 Nos (Out going) c) MCCB, 3 pole 100 Amps,18KA,Thermal magnetic - 3Nos (Out going) d) MCCB, 3 pole 40 Amps,18KA,Thermal magnetic - 2 Nos (Out going) e) Volt meter , digital type ,0 - 500V - 1 Nos f) Ammeter, digital type with CT's - 1 No g) indication lamps (R,Y,B) LED type - 1 set MAKE of MCCB : Schinder/C&S/ Legrand/Seimens/Benlo
Supply, fabrication, installation, testing & commissioning of LT Panel board / Feeder piller box,Outdoor type, dust and vermin proof, made out of 3.15mm thick CRCA sheet, front & back openable doors having aluminium bus bar of capacity 1000 amps for phases and 500 amps for neutral including powder coated painting, internal wiring with suitable size of stranded copper conductor cable, PCC foundation, supporting channels,cable termination, cable gland etc complete at Near Armoury including taking down old panel all as directed and suitable to accommodate the following switch gears and meters :- a) MCCB 630Amps 4pole,65 KA,Thermal magnetic - 1 Nos (Incomer) b) MCCB, 3 pole 250 Amps,37KA,Thermal magnetic - 03 Nos (Out going) c) MCCB, 3 pole 200 Amps,37KA,Thermal magnetic - 01 Nos (Out going) d) MCCB, 3 pole 150 Amps,18KA,Thermal magnetic - 09 Nos (Out going) e) MCCB, 3 pole 100 Amps,18KA,Thermal magnetic - 01 Nos (Out going) f) Volt meter , digital type ,0 - 500V - 1 Nos g) Ammeter, digital type with CT's - 1 No h) indication lamps (R,Y,B) LED type - 1 set MAKE of MCCB : Schinder/C&S/ Legrand/Seimens/Benlo
Supply, fabrication, installation, testing & commissioning of LT Panel board / Feeder piller box, indoor type, dust and vermin proof, made out of 2mm thick CRCA sheet,side canopy, front openable doors having aluminium bus bar of capacity 600 amps for phases and 300 amps for neutral including powder coated painting, internal wiring with suitable size of stranded copper conductor cable, PCC foundation, supporting channels,cable termination,cable gland etc complete at PUMP HOUSE INS ANGRE including taking down old panel all as directed and suitable to accommodate the following switch gears and meters :- a) MCCB 350Amps 4pole,37 KA,Thermal magnetic - 1 No (Incomer) b) Change over switch 315A, 4 pole open execution type-01 No c) MCCB, 3 pole 100 Amps,18KA,Thermal magnetic - 3 Nos (Out going) d) Star delta starter for 60 HP- 03 Nos (Make : L&T/C&S/Seimens) e) MCCB, 3 pole 30 Amps,18 KA,Thermal magnetic - 4 Nos (Out going) f) Star delta starter for 10HP - 04 Nos (Make : L&T/C&S/Seimens) g) DOL starter for 05 HP- 03 Nos (Make : L&T/C&S/Seimens) h) Volt meter , digital type ,0 - 500V - 1 Nos j) Ammeter, digital type with CT's - 1 No k) indication lamps (R,Y,B) LED type - 1 set MAKE of MCCB : Schinder/C&S/ Legrand/Seimens/Benlo
Supply, fabrication, installation, testing & commissioning of LT Panel board / Feeder piller box,Outdoor type, dust and vermin proof, made out of 3.15mm thick CRCA sheet, front & back openable doors having aluminium bus bar of capacity 1000 amps for phases and 500 amps for neutral including powder coated painting, internal wiring with suitable size of stranded copper conductor cable, PCC foundation, supporting channels,cable termination,cable gland etc complete at PCDA including taking down old panel all as directed and suitable to accommodate the following switch gears and meters :- a) MCCB 630Amps 4pole,65 KA,Thermal magnetic - 1 No (Incomer) b) MCCB, 3 pole 300 Amps,37KA,Thermal magnetic - 01 No (Out going) c) MCCB, 3 pole 100 Amps,18KA,Thermal magnetic - 04 Nos (Out going) d) MCCB, 3 pole 150 Amps,18KA,Thermal magnetic - 02 Nos (Out going) e) MCCB, 3 pole 60 Amps,18KA,Thermal magnetic - 02 Nos (Out going) f) MCCB 3 pole 32 Amp 10KA Thermal magnetic-01 No (Out going) g) Volt meter , digital type ,0 - 500V - 1 Nos h) Ammeter, digital type with CT's - 1 No j) indication lamps (R,Y,B) LED type - 1 set MAKE of MCCB : Schinder/C&S/ Legrand/Seimens/Benlo
Supply, fabrication, installation, testing & commissioning of LT Panel board / Feeder piller box, indoor type, dust and vermin proof, made out of 2mm thick CRCA sheet,side canopy, front openable doors having aluminium bus bar of capacity 200 amps for phases and 100 amps for neutral including powder coated painting, internal wiring with suitable size of stranded copper conductor cable, PCC foundation, supporting channels,cable termination,cable gland etc complete at PCDA PUMP HOUSE including taking down old panel all as directed and suitable to accommodate the following switch gears and meters :- a) MCCB 125Amps 4pole,37 KA,Thermal magnetic - 1 Nos (Incomer) b) Change over switch 125A, 4 pole, open execution type-01 No c) MCCB, 3 pole 30 Amps,18 KA,Thermal magnetic - 3 Nos (Out going) d) Star delta starter for 10HP - 03 Nos (Make : L&T/C&S/Seimens) e) DOL starter for 05 HP- 01 Nos (Make : L&T/C&S/Seimens) f) Volt meter , digital type ,0 - 500V - 1 Nos g) Ammeter, digital type with CT's - 1 No h) indication lamps (R,Y,B) LED type - 1 set MAKE of MCCB : Schinder/C&S/ Legrand/Seimens/Benlo
Supply, fabrication, installation, testing & commissioning of LT Panel board / Feeder piller box, indoor type, dust and vermin proof, made out of 2mm thick CRCA sheet,side canopy, front openable doors having aluminium bus bar of capacity 300 amps for phases and 200 amps for neutral including powder coated painting, internal wiring with suitable size of stranded copper conductor cable, PCC foundation, supporting channels,cable termination,cable gland etc complete at LIFT panel PCDA including taking down old panel all as directed and suitable to accommodate the following switch gears and meters :- a) MCCB 200Amps 4pole,37 KA,Thermal magnetic - 1 Nos (Incomer) b) MCCB, 3 pole 100 Amps,18 KA,Thermal magnetic - 3 Nos (Out going) c) MCB 32AMP 10KA SP -06 Nos d) Volt meter , digital type ,0 - 500V - 1 Nos e) Ammeter, digital type with CT's - 1 No f) indication lamps (R,Y,B) LED type - 1 set MAKE of MCCB : Schinder/C&S/ Legrand/Seimens/Benlo
Supply, fabrication, installation, testing & commissioning of LT Panel board / Feeder piller box, indoor type, dust and vermin proof, made out of 2mm thick CRCA sheet,side canopy, front openable doors having aluminium bus bar of capacity 200 amps for phases and 100 amps for neutral including powder coated painting, internal wiring with suitable size of stranded copper conductor cable, PCC foundation, supporting channels,cable termination,cable gland etc complete at Warali PUMP HOUSE including taking down old panel all as directed and suitable to accommodate the following switch gears and meters :- a) MCCB 125Amps 4pole,37 KA,Thermal magnetic - 1 Nos (Incomer) b) Change over switch 125A, 4 pole open execution type-01 No c) MCCB, 3 pole 30 Amps,18 KA,Thermal magnetic - 3 Nos (Out going) d) Star delta starter for 10HP - 03 Nos (Make : L&T/C&S/Seimens) e) MCB 32AMP 10KA TPN -06 Nos (Out going) f) Volt meter , digital type ,0 - 500V - 1 Nos g) Ammeter, digital type with CT's - 1 No h) indication lamps (R,Y,B) LED type - 1 set MAKE of MCCB : Schinder/C&S/ Legrand/Seimens/Benlo
Supply, fabrication, installation, testing & commissioning of LT Panel board / Feeder piller box,Outdoor type, dust and vermin proof, made out of 3.15mm thick CRCA sheet, front & back openable doors having aluminium bus bar of capacity 300 amps for phases and 150 amps for neutral including powder coated painting, internal wiring with suitable size of stranded copper conductor cable, PCC foundation, supporting channels,cable termination,cable gland etc complete at Warali ghoda maidan including taking down old panel all as directed and suitable to accommodate the following switch gears and meters :- a) MCCB 150Amps 4pole,26 KA,Thermal magnetic - 1 No (Incomer) b) MCCB, 3 pole 100 Amps,18KA,Thermal magnetic - 01 No (Out going) d) MCCB, 3 pole 60 Amps,18KA,Thermal magnetic - 03 Nos (Out going) e) MCB 32 Amps, 3 pole 10KA-02 Nos (Out going) f) Volt meter , digital type ,0 - 500V - 1 No g) Ammeter, digital type with CT's - 1 No h) indication lamps (R,Y,B) LED type - 1 set MAKE of MCCB : Schinder/C&S/ Legrand/Seimens/Benlo
Supply, fabrication, installation, testing & commissioning of Wall mounted LT Panel board / Feeder piller box, indoor type, dust and vermin proof, made out of 2mm thick CRCA sheet,side canopy, front openable doors having aluminium bus bar of capacity 600 amps for phases and 300 amps for neutral including powder coated painting, internal wiring with suitable size of stranded copper conductor cable, PCC foundation, supporting channels,cable termination,cable gland etc complete at ANNEX CWE complex including taking down old panel all as directed and suitable to accommodate the following switch gears and meters :- a) MCCB 400Amps 4pole,50 KA,Thermal magnetic - 1 No (Incomer) b) MCCB, 3 Pole 200 Amps,37 KA,Thermal magnetic - 2 Nos (Out going) c) MCCB 3 Pole 60 AMP 18KA SP -08 Nos (Out going) d) MCCB 32 Amps, 18 KA, Thermal magnetic- 01 No (Out going) e) Volt meter , digital type ,0 - 500V - 1 Nos f) Ammeter, digital type with CT's - 1 No g) indication lamps (R,Y,B) LED type - 1 set MAKE of MCCB : Schinder/C&S/ Legrand/Seimens/Benlo
Supply, fabrication, installation, testing & commissioning of Wall mounted LT Panel board / Feeder piller box, indoor type, dust and vermin proof, made out of 2mm thick CRCA sheet,side canopy, front openable doors having aluminium bus bar of capacity 600 amps for phases and 300 amps for neutral including powder coated painting, internal wiring with suitable size of stranded copper conductor cable, PCC foundation, supporting channels,cable termination,cable gland etc complete at P/A-72 Bldg INS Kunjali including taking down old panel all as directed and suitable to accommodate the following switch gears and meters :- a) MCCB 400Amps 4pole,50 KA,Thermal magnetic - 1 No (Incomer) b) MCCB, 3 Pole 150 Amps,18 KA,Thermal magnetic - 5 Nos (Out going) c) MCCB 3 Pole 100 AMP 18KA -01 No (Out going) d) Volt meter , digital type ,0 - 500V - 1 Nos e) Ammeter, digital type with CT's - 1 No f) indication lamps (R,Y,B) LED type - 1 set MAKE of MCCB : Schinder/C&S/ Legrand/Seimens/Benlo
Supply, fabrication, installation, testing & commissioning of LT Panel board / Feeder piller box,Outdoor type, dust and vermin proof, made out of 3.15mm thick CRCA sheet, front & back openable doors having aluminium bus bar of capacity 200 amps for phases and 100 amps for neutral including powder coated painting, internal wiring with suitable size of stranded copper conductor cable, PCC foundation, supporting channels,cable termination,cable gland etc complete at Near NAMAC director house including taking down old panel all as directed and suitable to accommodate the following switch gears and meters :- a) MCCB 150Amps 4pole,26 KA,Thermal magnetic - 1 No (Incomer) b) MCCB, 3 pole 32 Amps,10KA,Thermal magnetic - 02 Nos (Out going) c) MCB, SPN 32 Amps 10 KA - 12 Nos (Out going) d) Volt meter , digital type ,0 - 500V - 1 Nos e) Ammeter, digital type with CT's - 1 No f) indication lamps (R,Y,B) LED type - 1 set MAKE of MCCB : Schinder/C&S/ Legrand/Seimens/Benlo
Supply, fabrication, installation, testing & commissioning of LT Panel board / Feeder piller box,Outdoor type, dust and vermin proof, made out of 3.15mm thick CRCA sheet, front & back openable doors having aluminium bus bar of capacity 600 amps for phases and 300 amps for neutral including powder coated painting, internal wiring with suitable size of stranded copper conductor cable, PCC foundation, supporting channels,cable termination,cable gland etc complete at NAMAC including taking down old panel all as directed and suitable to accommodate the following switch gears and meters :- a) MCCB 400Amps 4pole,37 KA,Thermal magnetic - 1 Nos (Incomer) b) MCCB, 3 pole 100 Amps,18KA,Thermal magnetic - 05 Nos (Out going) c) MCB, SPN 32 Amps 10 KA - 02 Nos (Out going) d) Volt meter , digital type ,0 - 500V - 1 Nos e) Ammeter, digital type with CT's - 1 No f) indication lamps (R,Y,B) LED type - 1 set MAKE of MCCB : Schinder/C&S/ Legrand/Seimens/Benlo
Supply, fabrication, installation, testing & commissioning of LT Panel board / Feeder piller box,Outdoor type, dust and vermin proof, made out of 3.15mm thick CRCA sheet, front & back openable doors having aluminium bus bar of capacity 300 amps for phases and 150 amps for neutral including powder coated painting, internal wiring with suitable size of stranded copper conductor cable, PCC foundation, supporting channels,cable termination,cable gland etc complete at Near MT street light panel INS Kunjali including taking down old panel all as directed and suitable to accommodate the following switch gears and meters :- a) MCCB 200Amps 4pole,26 KA,Thermal magnetic - 1 Nos (Incomer) b) MCCB, 3 pole 60 Amps,18KA,Thermal magnetic - 02 Nos (Out going) d) MCCB, 3 pole 100Amps,18KA,Thermal magnetic - 02 Nos (Out going) e) Volt meter , digital type ,0 - 500V - 1 Nos f) Ammeter, digital type with CT's - 1 No g) indication lamps (R,Y,B) LED type - 1 set MAKE of MCCB : Schinder/C&S/ Legrand/Seimens/Benlo
Supply, fabrication, installation, testing & commissioning of LT Panel board / Feeder piller box,Outdoor type, dust and vermin proof, made out of 3.15mm thick CRCA sheet, front & back openable doors having aluminium bus bar of capacity 600 amps for phases and 300 amps for neutral including powder coated painting, internal wiring with suitable size of stranded copper conductor cable, PCC foundation, supporting channels,cable termination,cable gland etc complete at Near MT street light panel INS Kunjali including taking down old panel all as directed and suitable to accommodate the following switch gears and meters :- a) MCCB 400Amps 4pole,50 KA,Thermal magnetic - 1 No (Incomer) b) MCCB, 3 pole 150 Amps,18KA,Thermal magnetic - 04 Nos (Out going) c) MCCB, 3 pole 60 Amps,18KA,Thermal magnetic - 04 Nos (Out going) d) MCCB, 3 pole 100Amps,18KA,Thermal magnetic - 02 Nos (Out going) e) Volt meter , digital type ,0 - 500V - 1 Nos f) Ammeter, digital type with CT's - 1 No g) indication lamps (R,Y,B) LED type - 1 set MAKE of MCCB : Schinder/C&S/ Legrand/Seimens/Benlo
Supply, fabrication, installation, testing & commissioning of LT Panel board / Feeder piller box, in door type, dust and vermin proof, made out of 2mm thick CRCA sheet, front and back openable doors having aluminium bus bar of capacity 2400 amps for phases and 1200 amps for neutral including powder coated painting, internal wiring with suitable size of stranded copper conductor cable, foundation, supporting channels,cable termination,cable gland etc complete at Sub station including taking down old panel all as directed and suitable to accommodate the following switch gears and meters :- a) ACB Manual drawout type ,microprocess release 1600Amps 4pole,50 KA - 3 Nos b) MCCB, 3 pole 300 Amps, 37 KA thermal magnetic release -01 No (Out going) c) MCCB, 3 pole 250 Amps,37KA,Thermal magnetic- 8 Nos (Out going) d) MCCB, 3 pole 200 Amps,26KA,Thermal magnetic - 14 Nos (Out going) e) MCCB, 3 pole 150 Amps,26KA,Thermal magnetic - 04 Nos (Out going) f) MCCB, 3 pole 40 Amps,18KA - 04 Nos (Out going) g) Digital type Volt meter , digital type ,0 - 500V - 1 Nos h) Digital type Ammeter, digital type with CT's - 1 No j) indication lamps (R,Y,B) LED type - 1 set MAKE of MCCB : Schinder/C&S/ Legrand/Seimens/Benlo Note : Only Switch gear/MCCBs/ACB paid seprately.
Supply only Air circuit breaker electrical draout type microprocessor release 1600 Amps 4 pole 50KA all as specified and directed. Make : C&S Cat No AHA16N4P1600MO3.1 (S) /Legrand/ Seimens/Benlo
Supply only MCCB 3 pole 300 Amps , 37 KA thermal magentic complete all as specified and directed. Make : C&S Cat No CSC5N3300 /Legrand/ Seimens/Benlo
Supply only MCCB 250 Amps, 3 pole, 37 KA thermal magentic complete all as specified and directed. Make : C&S Cat No CSC4S3250 /Legrand/ Seimens/Benlo
Supply only MCCB 200 Amps, 3 pole, 26 KA thermal magentic complete all as specified and directed. Make : C&S Cat No CSC4N3200 /Legrand/ Seimens/Benlo
Supply only MCCB 150 Amps, 3 pole, 26 KA thermal magentic complete all as specified and directed. Make : C&S Cat No CSC4N3150 /Legrand/ Seimens/Benlo
Supply only MCCB 40 Amps, 3 pole, 18 KA thermal magentic complete all as specified and directed. Make : C&S Cat No CSC1S340 /Legrand/ Seimens/Benlo
S & F in repair Distribution Board double door, prewired type, made out of CRCA mild steel sheet surface with insulated material like polyester or with epoxy powder coating and IP 43 & IK 09 protection surface mounting SPN 8 way, 240 volts with bus bar rating 200 Amps, dust and vermin proof suitable for incorporation of MCB’s and isolators etc complete all as directed. Make -Legrand cat No 5076 10 or equivalent in Siemens /HPL/ C&S
S & F in repair Distribution Board double door, prewired type, made out of CRCA mild steel sheet surface with insulated material like polyester or with epoxy powder coating and IP 54 & IK 09 protection surface mounting TPN 6 way, 440 volts with copper bus bar rating 100 Amps for each phase with 2 neutral bar, dust and vermin proof suitable for incorporation of MCB’s etc complete all as directed. Make -Legrand cat No 5077 36 or equivalent in Siemens /HPL/ C&S
S & F in repair Distribution Board double door, prewired type, made out of CRCA mild steel sheet surface with insulated material like polyester or with epoxy powder coating and IP 54 & IK 09 protection surface mounting TPN 8 way, 440 volts with copper bus bar rating 100 Amps for each phase with 2 neutral bar, dust and vermin proof suitable for incorporation of MCB’s etc complete all as directed. Make -Legrand cat No 5077 376 or equivalent in Siemens /HPL/ C&S NOTE FOR ITEM NO. 22 TO 24 : [i] MCB DBs shall be concealed in wall wherever posible including making good the surface to match with surrounding.
S & F MCCB FP 125 Amps,16KA, complete all as specified and directed. Make : Legrand Cat Part No. 420016 or equivalent in siemens/C&S
S & F MCB SP 6-32 Amps,10KA, 'C' series 240V complete all as specified and directed. Make : Legrand cat part no 4085 87 to 95 or equivalent in siemens/C&S
S & F MCB SPN 63 Amps,10KA 'C' series 240V complete all as specified and directed. Make : Legrand Cat Part No. 4086 20 or equivalent in siemens/C&S
S & F MCB SPN 40 Amps,10KA 'C' series 240V complete all as specified and directed. Make : Legrand Cat Part No. 4086 18 or equivalent in siemens/C&S
S&F in repairs of 0.71mm thick powder coated aluminium sheet cover, alloy 31000 H4 in ridges, Hips vally gutter including suitable size of revits/nut bolts complete bending, shaping, drilling, cutting notching and all as specified and directed.
S &F in repair Ultra slim edge lit type recess mounting LED 2X2 Luminaire 36 watt and extruded aluminium housing with anti-glare diffuser provides high quality ecomonic energy saving lighting LED Luminaire suitable for 600 x 600 mm modular/POP/Gypsum ceiling complete all as specified and as directed. Make: Crompton cat No LCPL-36-CDL(2X2) / C&S cat No LTCRSLM36WATT2X2 or equivalent Cat part in Surya / Philips
Supply and fix vable jointing STRIGHT THROUGH JOINT complete with jointing material (Heat srinkable) for 1100V grade cable for XLPE armoured alluminium conductor cable of size 120 to 185 sqmm 3.5 cre complete all as specified and directed. Make : Rychem/3M or equivalent as approved by GE
Supply and fix vable jointing STRIGHT THROUGH JOINT complete with jointing material (Heat srinkable) for 1100V grade cable for XLPE armoured alluminium conductor cable of size 240 to 400 sqmm 3.5 cre complete all as specified and directed. Make :Rychem/3M or equivalent as approved by GE
Supply and fix vable jointing STRIGHT THROUGH JOINT complete with jointing material (Heat srinkable) for 1100V grade cable for XLPE armoured alluminium conductor cable of size 95 to 120 sqmm 3.5 core complete all as specified and directed. Make :Rychem/3M or equivalent as approved by GE
S & F in replacement 20 Amps Single pole and neutral enclosure with a Two Pin and earth plug and socket complete with one single pole MCB and making connections complete all as directed. Make -Legrand Cat Part No. 5078 14 or equivalent in Siemens /GE/ C&S
Supply and lay in repair cable XLPE Insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty) 1100 Volts grade with stranded copper conductor of size 10sq mm 4 core. laid in trench/ duct / along pole/wall etc including making connection complete all as directed. MAKE : Gloster/Polycab/Finolex/Havells/Plaza Note : 1. The cost of thimbles/lugs and cable gland etc is incl in quoted rate and no extra payment will be made for it.
Excavation in trenches n exc1.5m wide and n exc in depth for laying of cables and getting out in loose/soft soilcomplete all as specified and directed.
Returing filling in including spreading, levelling watering and well ramming in layers not exc 25cm complete all as specified and directed.
Removing excavated material n exc 50cm and deposting where directed at a level n exc 1.5m above the starting point complete all as specified and directed.
Material and labour for sand filling in trenches fine dry sand as sand cushioning to cable 8 cm before laying of cables and 15 cm after laying cable which shall be punned down to 10 cm complete all as specified and directed. (Note : Only punned down thickness( ie 18 cm) shall be measured and paid)
Supply and layingreinforceced precast concrete cable cover, class LV type , I, flat size 250mmx150mmx40mm laid across the cable complete all as specified and directed.
M&L for GI pipe light grade 100mm dia for protection of UG cable crossing of nalha/bgrdge/road etc complete all as directed.
M&L for cement concrete in 1:2:4 type B1 using 20mm grade stone aggregate for road cutting/pole couping exposed surfaced and fair and even finishing with out using any extra cement etc complete all as specified and directed
Supply and lay in repair cable XLPE Insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty) 1100 Volts grade with stranded copper conductor of size 185sq mm 3.5 core. laid in trench/ duct / along pole/wall etc including making connection complete all as directed. MAKE : Gloster/Polycab/Finolex/Havells/Plaza Note : The cost of thimbles/lugs and cable gland etc is incl in quoted rate and no extra payment will be made for it.
M&L for Earthing complete with galvanised steel earth plate electrode 600x600x6mm thick buried directly in ground (earth pit not less than 2.25 mtr below normal ground level) with top edge of the plate not less than 1.5 mtr below ground level connected to galvanised iron strip 25 x 4 mm means of bolts, nuts check nut & washers of galvanised iron or steel & connected to main switch including complete excavation and earth work in soft/loose soil and disposal of surplus soil to a distance not exc 50 meters, PCC Chamber (1:3:6) type C-2 precast RCC cover with frame, funnel wire mesh, 20mm bore light grade galvanised iron or steel pipe for water, charcoal or coke and salt in alternative layers of 15cm compacted thickness all round the earth electrode complete alll as shown in electrical plate No 5 of SSR part-I including welding with suitble electrode and testing complete all as directed.
S&F galvanised iron strip 25 x 4 mm or main earthing lead fixed to wall with clamps or recess or croses or buried in ground or drawn in conduits/pipe or fixed to poles or any other indicated situation for loop earthing etc as required all as specified and directed .
Ashish Enterprises
ELECTRO ASSOCIATES
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .