Loading…
Loading…
Tender Value
₹56.4 Cr
EMD Value
₹29.7 L
Closing Date
28 May 2026, 3:00 pmClosed
No
No
Single Packet System
Normal Tender
No
Not Applicable
Lowest to Highest
30 days
Expenditure
Revenue
ELEC
2 conditions · 2 needing a document upload
The tenderer must have a minimum average annual contractual turnover of 17 Cr. during the last three financial years. Note: The tenderer shall submit a CA certified Annual Construction Turnover Certificate for the last three financial years along with the audited balance sheets for the same period. In case the balance sheet for the most recent financial year is not audited or available, the financial years 2024-25, 2023-24, and 2022-23 shall be considered. Financial years prior to these shall not be taken into account while evaluating the Financial Eligibility Criteria.
4.1.Special Technical Eligibility Criteria: 4.1.1.The tenderer must have successfully completed or substantially completed any one of the following categories of work(s) during last 07 (seven) years, ending last day of month previous to the one in which tender is invited: 4.1.1.1.Three similar works each costing not less than the amount equal to Rs.3.38 Cr. 4.1.1.2.Two similar works each costing not less than the amount equal to Rs.4.51 Cr. 4.1.1.3.One similar work costing not less than the amount equal to Rs.6.77 Cr. The bidder shall submit supporting document/certificate to fulfil the technical criteria, failing which the offer/bid shall be summarily rejected. Note for Item 10.1: Work experience certificate from private individual shall not be considered. However, in addition to work experience certificates issued by any Govt. Organization, work experience certificate issued by Public listed company having average annual turnover of 500 crore and above in last 3 (three) financial years excluding the current financial year, listed on National Stock Exchange or Bombay Stock Exchange, incorporated/registered at least 5 years prior to the date of closing of tender, shall also be considered, provided the work experience certificate has been issued by a person authorized by the public listed company to issue such certificates. In case, tenderer submits work experience certificate issued by public listed company, the tenderer shall also submit along with work experience certificate, the relevant copy of work order, bill of quantities, bill wise details of payment received duly certified by Chartered Accountant, TDS certificate for all payments received and copy of final /last bill paid by company in support of above work experience certificate. 4.1.2.Similar Nature of work: "Execution of any 1*25Kv or 2*25Kv PSI works or execution of any 11Kv and above Overhead lines or transmission lines electrical works"
2 conditions
Please enter the percentage of local content in the material being offered. Please enter 0 for fully imported items, and 100 for fully indigenous items. The definition and calculation of local content shall be in accordance with the Make in India policy as incorporated in the tender conditions.
Please go through the tender document and check list (clause no. 18) for the documents required to be uploaded alongwith the bid.
Design, Supply, Erection, Testing, and Commissioning of Traction Sub-Stations and Switching Posts, excluding Transformers, SCADA System, and CRP, in connection with the upgradation of the electric traction system from 1x25 kV to 2x25 kV for the project being executed by Konkan Railway Corporation Limited.
KR-CO-EL-KATNI-SGRL-T-07-
KR-CO-EL-KATNI-SGRL-T-07-
Limited
Works - General
16 Months
Navi Mumbai, Maharashtra
₹0
₹29.7 L
28 May 2026
7 May 2026
14 May 2026
428 items across 8 schedules
| # | Description | Unit | Qty | Rate | Amount |
|---|---|---|---|---|---|
| — | — | — | 47,87,87,171.05 | ||
| — | 20.00 | — | — | ||
| Erection - Preparation of design & drawing incl. survey | — | — | — | 16,52,707.37 | |
| — | 650.00 | — | — | ||
| Supply - Concrete for fdn. & trench in hard soil | — | — | — | 32,70,050.85 | |
| — | 650.00 | — | — | ||
| Erection - Concrete for fdn. & trench in hard soil | — | — | — | 16,83,114.41 | |
| — | 7345.45 | — | — | ||
| Supply - Concrete for fdn. other than hard soil & rock | — | — | — | 3,80,40,739.37 | |
| — | 7345.45 | — | — | ||
| Erection - Concrete for fdn. other than hard soil & rock | — | — | — | 1,38,57,697.94 | |
| — | 2292.17 | — | — | ||
| RCC for foundation/pier/column/pile, cable trench & trench cover | — | — | — | 1,83,14,857.96 | |
| — | 806.76 | — | — | ||
| Supply of steel gantries / portals supportg. Struc.& small part steel work. | — | — | — | 6,83,41,279.14 | |
| — | 806.76 | — | — | ||
| Fabrication, galv. & erec. of steel gantries / portals supportg. Struc.& small part steel work. | — | — | — | 62,67,104.2 | |
| — | 1733.33 | — | — | ||
| Supply of Fencing Panels. | — | — | — | 76,94,237.14 | |
| — | 1733.33 | — | — | ||
| Erection of Fencing Panels. | — | — | — | 4,37,609.74 | |
| — | 46.00 | — | — | ||
| Supply of Fencing Uprights | — | — | — | 30,49,285.42 | |
| — | 46.00 | — | — | ||
| Erection of Fencing Uprights | — | — | — | 6,628.11 | |
| — | 81.32 | — | — | ||
| Supply of Fencing Gate | — | — | — | 2,14,781.97 | |
| — | 81.32 | — | — | ||
| Erection of Fencing Gate | — | — | — | 11,731.79 | |
| — | 2120.00 | — | — | ||
| Supply of Fencing Anti-Climbing device. | — | — | — | 1,40,532.29 | |
| — | 2120.00 | — | — | ||
| Erection of Fencing Anti-Climbing device. | — | — | — | 3,05,845.93 | |
| — | 4000.00 | — | — | ||
| Supply of ballast gravel in the switch yard. | — | — | — | 41,13,457.63 | |
| — | 4000.00 | — | — | ||
| Spreadg. of ballast gravel in the switch yard. | — | — | — | 30,086.24 | |
| — | 709.09 | — | — | ||
| Supply - Construction of Brick work. | — | — | — | 30,16,490.72 | |
| — | 709.09 | — | — | ||
| Erection - Construction of Brick work. | — | — | — | 1,86,235.51 | |
| — | 5763.64 | — | — | ||
| Supply - 12mm Plastering of Brick work. | — | — | — | 16,41,683.91 | |
| — | 5763.64 | — | — | ||
| Erection - 12mm Plastering of Brick work. | — | — | — | 2,57,978.9 | |
| — | 200.00 | — | — | ||
| Supply of dry stone boulder pitching of aprox 300mm thickness in exposed slopes at SWS, TSS and OHE Foundations etc . | — | — | — | 1,85,305.35 | |
| — | 200.00 | — | — | ||
| Laying of dry stone boulder pitching of aprox 300mm thickness in exposed slopes at SWS, TSS and OHE Foundations etc . | — | — | — | 45,943.47 | |
| — | 18518.18 | — | — | ||
| Supply - Earthwork in filling at SWS, TSS and OHE Foundations. | — | — | — | 71,92,665.83 | |
| — | 18518.18 | — | — | ||
| Erection - Earthwork in filling at SWS, TSS and OHE Foundations. | — | — | — | 11,23,425.91 | |
| — | 954.55 | — | — | ||
| Construction of approach road for TSS and Control room buildings | — | — | — | 1,48,30,239.54 | |
| — | 160.00 | — | — | ||
| Provision of Cross Track in Traction Sub station | — | — | — | 8,77,143.05 | |
| — | 4.00 | — | — | ||
| Construction o f Switching station buidling, RCC work, plastering, brick masonary, retaining wall, filling, compacting and leveling work etc as per RDSO standard drawing and supply and erection of name board of switching station for TSS including Electrification of switching station & Arrangement of water supply. | — | — | — | 67,97,837.93 | |
| — | 15.00 | — | — | ||
| Construction o f Switching station buidling, RCC work, plastering, brick masonary, retaining wall, filling, compacting and leveling work etc as per RDSO standard drawing and supply and erection of name board of switching station for SP & SSP including Electrification of switching station & Arrangement of water supply. | — | — | — | 1,51,57,429.21 | |
| — | 25.00 | — | — | ||
| Supply, installation, testing and commissioning of submersible pump set suitable to operate on 3 phase, 415V, 50Hz AC supply along with control panel etc. complete for supplying water at suitable discharge and head as per site requirement: 1 HP Pump set | — | — | — | 2,58,940.68 | |
| — | 12.00 | — | — | ||
| Supply of 132KV, 1250/1600 Amp. Triple pole isolators with earth blade | — | — | — | 33,29,237.29 | |
| — | 12.00 | — | — | ||
| Erection of 132KV, 1250/1600 Amp. Triple pole isolators with earth blade | — | — | — | 53,374.33 | |
| — | 8.00 | — | — | ||
| Supply of 132KV, 1250/1600 Amp. Triple pole isolators without earth blade | — | — | — | 20,71,525.42 | |
| — | 8.00 | — | — | ||
| Erection of 132KV, 1250/1600 Amp. Triple pole isolators without earth blade | — | — | — | 31,635.15 | |
| — | 24.00 | — | — | ||
| Supply of 132KV current Transformers (800-400/5A). | — | — | — | 25,29,954 | |
| — | 24.00 | — | — | ||
| Erection of 132KV current Transformers (800-400/5A). | — | — | — | 2,52,986.52 | |
| — | 8.00 | — | — | ||
| Supply of neutral current Transformers | — | — | — | 3,75,833.9 | |
| — | 8.00 | — | — | ||
| Erection of neutral current Transformers | — | — | — | 36,695.59 | |
| — | 48.00 | — | — | ||
| Supply of 120 KV lightening arrester with surge monitor. | — | — | — | 20,14,090.9 | |
| — | 48.00 | — | — | ||
| Erection of 120 KV lightening arrester with surge monitor. | — | — | — | 2,43,291.78 | |
| — | 8.00 | — | — | ||
| Supply of 132 KV, 1600A Triple pole, outdoor SF6 circuit breaker as per RDSO specification. | — | — | — | 81,01,849.87 | |
| — | 8.00 | — | — | ||
| Erection of 132 KV, 1600A Triple pole, outdoor SF6 circuit breaker as per RDSO specification. | — | — | — | 61,070.64 | |
| — | 104.00 | — | — | ||
| Supply of 132 KV termination with adjuster complete with disc insulators. | — | — | — | 13,82,712.15 | |
| — | 104.00 | — | — | ||
| Erection of 132 KV termination with adjuster complete with disc insulators. | — | — | — | 39,625.32 | |
| — | 96.00 | — | — | ||
| Supply of 132 KV termination without adjuster complete with disc insulators. | — | — | — | 11,27,050.69 | |
| — | 96.00 | — | — | ||
| Erection of 132 KV termination without adjuster complete with disc insulators. | — | — | — | 36,577.22 | |
| — | 21.00 | — | — | ||
| Supply of 132 KV/25 KV system connectors, splices all type of PG Style -I & II including Nut Bolt | — | — | — | 51,89,202.26 | |
| — | 16.00 | — | — | ||
| Supply of shunt capacitor bank for 2x25KV TSS (4 Mvar-capacity) as per RDSO specification No. Latest. (To be procured from RDSO/CORE approved sources only). | — | — | — | 64,19,385.03 | |
| — | 16.00 | — | — | ||
| Erection of shunt capacitor bank for 2x25KV TSS (4 Mvar-capacity) as per RDSO specification No. Latest. (To be procured from RDSO/CORE approved sources only). | — | — | — | 6,45,499.16 | |
| — | 16.00 | — | — | ||
| Supply of series reactor detuned for 2x25 KV TSS as per RDSO specification No. Latest. (To be procured from RDSO/CORE approved sources only). | — | — | — | 1,23,05,985.56 | |
| — | 16.00 | — | — | ||
| Erection of series reactor detuned for 2x25 KV TSS as per RDSO specification No. Latest. (To be procured from RDSO/CORE approved sources only). | — | — | — | 12,30,604.47 | |
| — | 32.00 | — | — | ||
| Supply of 50 KV current transformer ratio 200-100/5A for PFC bay. | — | — | — | 33,73,272 | |
| — | 32.00 | — | — | ||
| Erection of 50 KV current transformer ratio 200-100/5A for PFC bay. | — | — | — | 3,37,362.71 | |
| — | 24.00 | — | — | ||
| Supply of 50 KV, 2000A Double pole, outdoor SF6 circuit breaker for PFC as per RDSO specification. | — | — | — | 2,12,89,362.71 | |
| — | 24.00 | — | — | ||
| Erection of 50 KV, 2000A Double pole, outdoor SF6 circuit breaker for PFC as per RDSO specification. | — | — | — | 19,53,152.54 | |
| — | 4.00 | — | — | ||
| "Supply of Special Energy Meter of 0.2s Class accuracy with ABT, complete feature including software, hardware, meter cubical etc. as per the latest specification / grid code/ metering regulations / amendments to regulations of concerned Transmission /Regulatory Authority. This item is including following components: 1) DATA Concentrator unit (DCU) along with software. 2) Industrial Ethernet switch. 3) GPRS/GSM modem (external) as per specification. 4) Armored Fiber optical cable as per specification." | — | — | — | 44,52,447.97 | |
| — | 4.00 | — | — | ||
| Erection, testing and commissioning of Special Energy Meter of 0.2s Class accuracy with ABT, complete feature including software, hardware, meter cubical etc. as per the latest specification / grid code/ metering regulations / amendments to regulations of concerned Transmission /Regulatory Authority. This item is including following components: 1) DATA Concentrator unit (DCU) along with software. 2) Industrial Ethernet switch. 3) GPRS/GSM modem (external) as per specification. 4) Armored Fiber optical cable as per specification. | — | — | — | 8,56,318.3 | |
| — | 24.00 | — | — | ||
| Supply of 132 KV/110V/15VA potential transformer 0.2 class as per RDSO spec. attached. | — | — | — | 25,29,954 | |
| — | 24.00 | — | — | ||
| Erection of 132 KV/110V/15VA potential transformer 0.2 class as per RDSO spec. attached. | — | — | — | 2,53,022.03 | |
| — | 24.00 | — | — | ||
| Supply of 132 KV Current transformer 0.2 class as per RDSO spec. attached. | — | — | — | 25,29,954 | |
| — | 24.00 | — | — | ||
| Erection of 132 KV Current transformer 0.2 class as per RDSO spec. attached. | — | — | — | 2,53,022.03 | |
| — | 2909.09 | — | — | ||
| Supply of ACSR Zebra conductor | — | — | — | 32,80,004.92 | |
| — | 2909.09 | — | — | ||
| Erection of ACSR Zebra conductor | — | — | — | 60,693 | |
| — | 1200.00 | — | — | ||
| Supply of 36 mm AAAC. BERSISMIS CONDUCTOR (767 SQ MM) (IS: 398 Part-4, 767mm2, 61/4.00 conductors) including all connectors etc. | — | — | — | 6,17,906.44 | |
| — | 1200.00 | — | — | ||
| Erection, testing & commissioning of 36 mm AAAC. BERSISMIS CONDUCTOR (767 SQ MM) (IS: 398 Part-4, 767mm2, 61/4.00 conductors) including all connectors etc. | — | — | — | 1,28,730.51 | |
| — | 16.00 | — | — | ||
| Supply of 50 KV isolator double pole | — | — | — | 37,87,932.2 | |
| — | 16.00 | — | — | ||
| Erection of 50 KV isolator double pole | — | — | — | 86,293.83 | |
| — | 104.50 | — | — | ||
| Supply of 25 KV isolator double pole | — | — | — | 2,35,02,935.59 | |
| — | 104.50 | — | — | ||
| Erection of 25 KV isolator double pole | — | — | — | 5,35,426.25 | |
| — | 24.00 | — | — | ||
| Supply of 25 KV isolator double pole (Motorised) | — | — | — | 27,78,235.2 | |
| — | 24.00 | — | — | ||
| Erection of 25 KV isolator double pole (Motorised) | — | — | — | 64,720.37 | |
| — | 57.00 | — | — | ||
| Supply of 25 KV isolator single pole | — | — | — | 1,02,86,033.05 | |
| — | 57.00 | — | — | ||
| Erection of 25 KV isolator single pole | — | — | — | 4,04,384.03 | |
| — | 32.00 | — | — | ||
| Supply of 60 KV Lightening arrestor | — | — | — | 11,73,312 | |
| — | 32.00 | — | — | ||
| Erection of 60 KV Lightening arrestor | — | — | — | 1,17,331.2 | |
| — | 173.00 | — | — | ||
| Supply of 42 KV Lightening arrestor | — | — | — | 44,40,252.6 | |
| — | 173.00 | — | — | ||
| Erection of 42 KV Lightening arrestor | — | — | — | 4,44,127.65 | |
| — | 192.00 | — | — | ||
| Supply of 25 KV potential transformer as per RDSO spec. Type - I & Type - II | — | — | — | 92,33,084.75 | |
| — | 192.00 | — | — | ||
| Erection of 25 KV potential transformer as per RDSO spec. Type - I & Type - II | — | — | — | 20,24,176.27 | |
| — | 51.00 | — | — | ||
| Supply of 25 KV CT (200-100/5A) | — | — | — | 25,67,165.99 | |
| — | 51.00 | — | — | ||
| Erection of 25 KV CT (200-100/5A) | — | — | — | 1,96,316.24 | |
| — | 39.00 | — | — | ||
| Supply of 50 KVA, 25KVA, 10KVA/240 V LT supply Transformer with DO fuse, anti climbing device, copper jumpers & earth electrode etc. | — | — | — | 80,99,348.5 | |
| — | 39.00 | — | — | ||
| Erection, testing and commissioning of 50 KVA, 25KVA, 10KVA/240 V LT supply Transformer with DO fuse, anti climbing device, copper jumpers & earth electrode etc. | — | — | — | 8,09,943.51 | |
| — | 39.00 | — | — | ||
| Supply of L V box assembly | — | — | — | 58,139.58 | |
| — | 39.00 | — | — | ||
| Erection of L V box assembly | — | — | — | 6,492.01 | |
| — | 5500.00 | — | — | ||
| Supply of tubular aluminium bus bars 50mm x 39mm dia including all connectors, bus splice etc. as required | — | — | — | 74,62,670.34 | |
| — | 5500.00 | — | — | ||
| Erection of tubular aluminium bus bars 50mm x 39mm dia including all connectors, bus splice etc. as required | — | — | — | 3,01,111.02 | |
| — | 204.00 | — | — | ||
| Supply of 132 KV support insulator | — | — | — | 37,73,135.59 | |
| — | 204.00 | — | — | ||
| Erection of 132 KV support insulator | — | — | — | 1,11,986.66 | |
| — | 1078.00 | — | — | ||
| Supply of 25 KV support insulator/pedestal Insulators | — | — | — | 75,76,604.24 | |
| — | 1078.00 | — | — | ||
| Erection of 25 KV support insulator/pedestal Insulators | — | — | — | 7,21,771.25 | |
| — | 128.00 | — | — | ||
| Supply of 66 KV support insulator | — | — | — | 23,67,457.63 | |
| — | 128.00 | — | — | ||
| Erection of 66 KV support insulator | — | — | — | 48,012.04 | |
| — | 4.00 | — | — | ||
| Supply of 230V AC LT distribution board for 50 KVA LT supply x-mer in cont.room | — | — | — | 12,30,841.22 | |
| — | 4.00 | — | — | ||
| Erection of 230V AC LT distribution board for 50 KVA LT supply x-mer in cont.room | — | — | — | 1,93,317.71 | |
| — | 4.00 | — | — | ||
| Supply of low maintenance lead acid battery set 250AH, 110V DC as per latest RDSO specifications including filling up of electrolyte and initial charging /discharging as required for TSS | — | — | — | 11,35,592.48 | |
| — | 4.00 | — | — | ||
| Erection, testing and commissioning of low maintenance lead acid battery set 250AH, 110V DC as per latest RDSO specifications including filling up of electrolyte and initial charging /discharging as required for TSS | — | — | — | 56,780.51 | |
| — | 8.00 | — | — | ||
| Supply of Battery Charger (automatic) suitable for 110V, 250AH low maintenance Lead Acid Battery set as per latest RDSO specifications including all accessories for TSS | — | — | — | 14,54,915.17 | |
| — | 8.00 | — | — | ||
| Erection, testing and commissioning of Battery Charger (automatic) suitable for 110V, 250AH low maintenance Lead Acid Battery set as per latest RDSO specifications including all accessories for TSS | — | — | — | 90,496.07 | |
| — | 15.00 | — | — | ||
| Supply of low maintenance lead acid battery set 200AH, 110V DC as per latest RDSO specifications including filling up of electrolyte and initial charging /discharging as required for SP & SSP | — | — | — | 12,30,042.2 | |
| — | 15.00 | — | — | ||
| Erection, testing and commissioning of low maintenance lead acid battery set 200AH, 110V DC as per latest RDSO specifications including filling up of electrolyte and initial charging /discharging as required for SP & SSP | — | — | — | 1,69,680.13 | |
| — | 15.00 | — | — | ||
| Supply of Battery Charger (automatic) suitable for 110V, 200AH low maintenance Lead Acid Battery set as per latest RDSO specifications including all accessories for SP & SSP | — | — | — | 10,90,358.5 | |
| — | 15.00 | — | — | ||
| Erection, testing and commissioning of Battery Charger (automatic) suitable for 110V, 200AH low maintenance Lead Acid Battery set as per latest RDSO specifications including all accessories for SP & SSP | — | — | — | 94,328.39 | |
| — | 42.00 | — | — | ||
| Supply of 240Volt AC and 110Volt DC Distribution boards in the control room. | — | — | — | 13,54,466.9 | |
| — | 42.00 | — | — | ||
| Erection testing & commissioning of 240Volt AC and 110Volt DC Distribution boards in the control room. | — | — | — | 28,742.42 | |
| — | 11375.00 | — | — | ||
| Supply of PVC insulated and sheathed copper unarmored cable size 10 core 2.5 sqmm | — | — | — | 71,11,158.37 | |
| — | 11375.00 | — | — | ||
| Erection of PVC insulated and sheathed copper unarmored cable size 10 core 2.5 sqmm | — | — | — | 4,54,440.88 | |
| — | 5000.00 | — | — | ||
| Supply of PVC insulated and sheathed copper unarmored cable size 12 core 2.5 sqmm | — | — | — | 36,06,673.73 | |
| — | 5000.00 | — | — | ||
| Erection of PVC insulated and sheathed copper unarmored cable size 12 core 2.5 sqmm | — | — | — | 1,99,754.24 | |
| — | 19750.00 | — | — | ||
| Supply of PVC insulated and sheathed copper unarmored cable size 7 core 2.5 sqmm | — | — | — | 83,57,865.26 | |
| — | 19750.00 | — | — | ||
| Erection of PVC insulated and sheathed copper unarmored cable size 7 core 2.5 sqmm | — | — | — | 7,89,029.23 | |
| — | 3333.33 | — | — | ||
| Supply of PVC insulated and sheathed copper unarmored cable size 4 core 4 sqmm | — | — | — | 9,62,766.09 | |
| — | 3333.33 | — | — | ||
| Erection of PVC insulated and sheathed copper unarmored cable size 4 core 4 sqmm | — | — | — | 1,33,169.49 | |
| — | 22333.33 | — | — | ||
| Supply of PVC insulated and sheathed copper unarmored cable size 2 core 2.5 sqmm | — | — | — | 30,23,687.28 | |
| — | 22333.33 | — | — | ||
| Erection of PVC insulated and sheathed copper unarmored cable size 2 core 2.5 sqmm | — | — | — | 8,92,235.58 | |
| — | 6666.67 | — | — | ||
| Supply of PVC insulated and sheathed copper unarmored cable size 2 core 4 sqmm | — | — | — | 13,23,803.39 | |
| — | 6666.67 | — | — | ||
| Erection of PVC insulated and sheathed copper unarmored cable size 2 core 4 sqmm | — | — | — | 2,66,338.98 | |
| — | 2416.67 | — | — | ||
| Supply of PVC insulated and sheathed copper armored cable size 2 core 70 sqmm | — | — | — | 9,81,570.14 | |
| — | 2416.67 | — | — | ||
| Erection of PVC insulated and sheathed copper armored cable size 2 core 70 sqmm | — | — | — | 96,547.88 | |
| — | 666.67 | — | — | ||
| Supply of PVC insulated and sheathed copper armored cable size 2 core 150 sqmm | — | — | — | 5,41,555.96 | |
| — | 666.67 | — | — | ||
| Erection of PVC insulated and sheathed copper armored cable size 2 core 150 sqmm | — | — | — | 26,633.9 | |
| — | 414.00 | — | — | ||
| Suply of solid core cut in/ suspension / 9T feeder insulator | — | — | — | 21,60,568.46 | |
| — | 414.00 | — | — | ||
| Erection of solid core cut in/ suspension / 9T feeder insulator | — | — | — | 3,32,937.05 | |
| — | 2123.33 | — | — | ||
| Supply of 38.25 mm dia (865 sq.mm) AAC Bull conductor | — | — | — | 21,11,298.68 | |
| — | 2123.33 | — | — | ||
| Erection of 38.25 mm dia (865 sq.mm) AAC Bull conductor | — | — | — | 2,11,129.87 | |
| — | 427.27 | — | — | ||
| Supply of structure bond | — | — | — | 2,24,627.32 | |
| — | 427.27 | — | — | ||
| Erection of structure bond | — | — | — | 49,028.56 | |
| — | 760.00 | — | — | ||
| Supply - Earthing with 4m long, 50mm dia, G.I. pipe class 'B' earth electrode, adding the charcoal or coke and salt, providing concrete enclosure and MS cover plate with lifting arrangement etc. including connections with 4mm G.I. wire from earth electrode to switch board/ electrical equipment as required. | — | — | — | 35,16,668.91 | |
| — | 760.00 | — | — | ||
| Erection - Earthing with 4m long, 50mm dia, G.I. pipe class 'B' earth electrode, adding the charcoal or coke and salt, providing concrete enclosure and MS cover plate with lifting arrangement etc. including connections with 4mm G.I. wire from earth electrode to switch board/ electrical equipment as required. | — | — | — | 4,72,971.28 | |
| — | 8850.00 | — | — | ||
| Supply of earth leads 75 x 8mm mild steel flat laid in the ground or exposed as per site requirement. | — | — | — | 16,96,391.77 | |
| — | 8850.00 | — | — | ||
| Erection of earth leads 75 x 8mm mild steel flat laid in the ground or exposed as per site requirement. | — | — | — | 4,89,883.95 | |
| — | 17200.00 | — | — | ||
| Supply of earth leads 50 x 6mm mild steel flat laid in the ground or exposed as per site requirement | — | — | — | 15,91,653.6 | |
| — | 17200.00 | — | — | ||
| Erection of earth leads 50 x 6mm mild steel flat laid in the ground or exposed as per site requirement | — | — | — | 7,63,505.09 | |
| — | 4400.00 | — | — | ||
| Supply of 8 SWG GI Wire for earthing. | — | — | — | 3,58,077.97 | |
| — | 4400.00 | — | — | ||
| Erection of 8 SWG GI Wire for earthing. | — | — | — | 79,753.73 | |
| — | 7200.00 | — | — | ||
| Supply of 32mm to 40mm dia MS rod for earth mat. | — | — | — | 18,64,372.88 | |
| — | 7200.00 | — | — | ||
| Erection of 32mm to 40mm dia MS rod for earth mat. | — | — | — | 1,33,861.98 | |
| — | 6750.00 | — | — | ||
| Supply of earth screen wire including termination. | — | — | — | 17,25,676.86 | |
| — | 6750.00 | — | — | ||
| Erection of earth screen wire including termination. | — | — | — | 77,854.22 | |
| — | 23.00 | — | — | ||
| Supply of fire extinguishing equipments (ISI) Marked, Rubber mat (ISI marked), G.I. fire buckets filled with clean dry sand held on free standing steel stand, first aid box with medicine (ISI marked) and associated materials, shock treatment chart on aluminium frame, schematic diagram of HT/LT installation & transformer data on white hylem sheet with aluminium frame & fixing/ providing in the sub station area as per details in Explanatory notes. | — | — | — | 15,85,764.55 | |
| — | 23.00 | — | — | ||
| Erection/ Fixing of fire extinguishing equipments (ISI) Marked, Rubber mat (ISI marked), G.I. fire buckets filled with clean dry sand held on free standing steel stand, first aid box with medicine (ISI marked) and associated materials, shock treatment chart on aluminium frame, schematic diagram of HT/LT installation & transformer data on white hylem sheet with aluminium frame & fixing/ providing in the sub station area as per details in Explanatory notes. | — | — | — | 2,49,030.65 | |
| — | 4.00 | — | — | ||
| Supply of safety items i.e. Fire extinguishers, set of fire bucket with stand and first aid box, key box with suitable key chain, locks and other misc items required for commissioning of switching station. | — | — | — | 53,202.69 | |
| — | 4.00 | — | — | ||
| Erection of safety items i.e. Fire extinguishers, set of fire bucket with stand and first aid box, key box with suitable key chain, locks and other misc items required for commissioning of switching station. | — | — | — | 8,809.9 | |
| — | 400.00 | — | — | ||
| Supply of Retro-reflective type boards 25kV AC OHE danger board/ danger board for height gauge, public, staff caution board and special boards required for commissioning of OHE/SWSs. | — | — | — | 3,72,874.58 | |
| — | 400.00 | — | — | ||
| Erection of Retro-reflective type boards 25kV AC OHE danger board/ danger board for height gauge, public, staff caution board and special boards required for commissioning of OHE/SWSs. | — | — | — | 1,32,429.66 | |
| — | 12.00 | — | — | ||
| Supply of burried earth rail, including supply and erection of earth leads as per site requirement. (Rail will be provided by Railway) | — | — | — | 13,93,521.07 | |
| — | 12.00 | — | — | ||
| Erection, testing & commissioning of burried earth rail, including supply and erection of earth leads as per site requirement. (Rail will be provided by Railway) | — | — | — | 3,48,371.39 | |
| — | 58.00 | — | — | ||
| Manning of switching station i.e. SP/SSP and TSS | — | — | — | 24,09,406.02 | |
| — | 2300.00 | — | — | ||
| Supply of 150 Sqmm. Copper Cross feeder | — | — | — | 59,06,288.9 | |
| — | 2300.00 | — | — | ||
| Erection of 150 Sqmm. Copper Cross feeder | — | — | — | 81,677.29 | |
| — | 280.00 | — | — | ||
| Supply of copper jumper with fittings and fasteners required for TSS/SP/SSP | — | — | — | 19,18,646.85 | |
| — | 280.00 | — | — | ||
| — | 286.00 | — | — | ||
| Supply - Cross feeder termination | — | — | — | 41,26,034.75 | |
| — | 286.00 | — | — | ||
| Erection - Cross feeder termination | — | — | — | 8,25,206.95 | |
| — | 10.00 | — | — | ||
| Supply of all aluminium 25 kV feeder wire | — | — | — | 15,36,302.44 | |
| — | 10.00 | — | — | ||
| Erection of all aluminium 25 kV feeder wire | — | — | — | 3,07,266.41 | |
| — | 880.00 | — | — | ||
| Supply of 19/2.5mm Galvanized Steel Stranded Earth Wire | — | — | — | 6,04,989 | |
| — | 880.00 | — | — | ||
| Erection of 19/2.5mm Galvanized Steel Stranded Earth Wire | — | — | — | 76,172.95 | |
| — | 100.00 | — | — | ||
| Supply of copper strip for equipment earthing | — | — | — | 4,10,827.88 | |
| — | 100.00 | — | — | ||
| Erection of copper strip for equipment earthing | — | — | — | 43,280.08 | |
| — | — | — | 4,36,50,000.02 | ||
| — | 19.00 | — | — |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
HTML
nit.pdf
NIT
KTNI-SGRL-WCR-T-07-
ATTACHMENT
KTE-SG_ExplanatoryNotes.pdf Explanatory Notes
ATTACHMENT
Limitedtender-BalanceItems-KTNI-SGRL-WCR-T-07-2026.pdf
ATTACHMENT
KTE-SG_ExplanatoryNotes.pdf
ATTACHMENT
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .