Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance | Admitted-Finance |
| 2 | Admitted-Finance | Admitted-Finance |
| 3 | Admitted-Finance AZAD NAGAR AZAD NAGAR HARDOI UTTAR PRADESH 241001 UDYAM UP 35 0017189 | HARDOI | UTTAR PRADESH | 241001 | Admitted-Finance |
Tender Value
Refer Docs
EMD Value
₹25,000
Closing Date
27 Jun 2024, 2:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
ASHA NAGAR HARDOI
ASHA NAGAR HARDOI
15/EDC(H)/2024-25
2024_MVVNL_931552_1
15/EDC(H)/2024-25
Open Tender
Miscellaneous Works
Item Rate
180 days
EDC HARDOI
Please refer Tender documents.
2 documents required · 2 mandatory
₹3,540
A/C No. 066505005389, IFSC Code ICIC0000665, ICIC
₹25,000
15 Jul 2024
21 Jun 2024
28 Jun 2024
21 Jun 2024
27 Jun 2024
21 Jun 2024
Amount
Safe carriage, loading-unloading with proper stacking of following material from store centre to pit site/JE dump store.
PCC Pole of size 8.5 mtr long
ST pole 11 mtr. Long.
Stay Set Complete
11 KV Insulator and Pin with Net
33 KV Insulator and Pin with Net
11 KV X-arm
33 KV X-arm
Disc insulator With fitting
MS Earthing Rod
ACSR Weasel Conductor
ACSR Dog/Rabbit Conductor
GI Wire
11/0.4 KV T/F 25/16/10 KVA
11 KV XLPE cable of size 3×70 sq. mm.
11 KV XLPE cable of size 3×185,3×120 & 3x300 sq. mm.
Cable box 3×185, 3×70, 3×120 for 11 KV Line Indoor & Outdoor
Cable box 3x300, 3x120 for 33 KV Line Indoor & Outdoor
ABC of size (3×120+1×95+1×16) sq. mm.
ABC of size (3×95+1×70+1×16) sq. mm.
ABC of size (3×50+1×35+1×16) sq. mm.
ABC of size (1×16+1×25) sq. mm.
LT XLPE Cable Aluminum 3.5x240 sq. mm
LT XLPE Cable Aluminum 3.5x400 sq. mm
LT XLPE Cable Aluminum 1x240 sq. mm
LT XLPE Cable Aluminum 1x400 sq. mm
Line Material
Replacement of Broken PCC single Pole and Erection of PCC Pole 8.5 mtr long with Grouting & with all accessories
Replacement of Broken PCC double Pole and Erection of PCC Pole 8.5 mtr long with Grouting & with all accessories
Replacement of Broken ST single Pole and Erection of ST Pole 11 mtr long with Grouting & with all accessories
Replacement of Broken ST double Pole and Erection of ST Pole 11 mtr long with Grouting & with all accessories
Re-Stringing of three phase ACSR Weasel Conductor for 11 KV line.
Tilted of PCC/ ST Pole.
Rebinding of Stay Set Complete.
Laying of 11 KV 3×70 sq. mm. Single XLPE cable by digging of trench.
Laying of 11 KV 3×120/3×185/3x300 sq. mm. Single XLPE cable by digging of trench.
Cable hoisting of 11 KV XLPE Cable on double pole (3×70, 3×120, 3×185 & 3x300) sq. mm. including jumpering etc. Complete with help of GI Pipe as per RESPO Norms.
Installation of cable box 11 KV Indoor & Outdoor
Installation of cable box 33 KV Indoor & Outdoor
Stringing & Sagging of LT XLPE Cable Aluminum 1x400 sq. mm
Stringing & Sagging of LT XLPE Cable Aluminum 3.5x400 sq. mm
Stringing & Sagging of LT XLPE Cable Aluminum 1x240 sq. mm
Stringing & Sagging of LT XLPE Cable Aluminum 3.5x240 sq. mm
Stringing & Sagging of (1×16+1×25) sq. mm single phase ABC.
Stringing & Sagging of (3×120+1×95+1×16) sq. mm. ABC.
Stringing & Sagging of (3×95+1×70+1×16) sq. mm. ABC.
Stringing & Sagging of (3×50+1×35+1×16) sq. mm. ABC.
Repairing of Damage T/F Plinth and including jumpering with the system (All the required martial for above work shall be provided by contractor except T/Fs)Placement of 11/0.4 KV T/Fs with the help of crane sleepers and man power etc. from dump place to newly constructed T/Fs plinth & erection & commissioning of 250/400 KVA T/Fs
Fabrication erection and commissioning of 25/16/10 KVA T/F on double/single pole with all accessories.
Construction of retaining wall, fabrication and erection of wire mesh fencing of size 3+3 and 2.0 mtr height around T/F and distribution pillar box with retaining wall and 01 no. gate with locking arrangement made of MS angle iron of size 50x50x6 mm jointed with the nuts and bolt. The panel must be supported with MS flat of size 50x6 mm wire mesh of size 10 SWG rectangle type.
Construction of T/F plinth of size 2x2x1.5 mtr on a padding 0.25 Mtr deep in ground 1:5:10 cement sand and brick ballast on the top of padding brick work Ist class brick of 0.95 mtr height & 0.35 mtr wall will be constructed. Rest wall should be 0.23 mtr thick. Brick work in ratio 1:4 cement & cores Sand in the hollow portion the sand should be filled from the ground level upto 15 centimeter below from the top of wall, Cement, sand & brick Ballasts should be filled up to 15 centimeter.
Erection of Stay set complete.
Fixing of Ordinary Earthing by 11 KV MS earth Rod 2500 mm long as per RESPO schedule.
Stringing of ACSR Weasel Conductor for 11 KV line
Stringing of ACSR Dog/Rabbit Conductor for 33 KV line
Guarding of 33 KV Line
Guarding of 11 KV Line
Looping & chopping of tree branches for clearance of HT/LT line after clearance of line throughout pieces of tree branches of site.
Dismantling of old & used (Existing) material and loading, carriage & unloading from site to JE Dump Store/Store centre, Hardoi.
STP 11 mtr long single pole with all accessories
Scrap Materials
M/S S.K. CONTRACTOR AND SUPPLIER
M/S RUDRA CONTRACTOR AND SUPPLIER BAREPUR ANDHARRA HARDOI
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .