Loading…
Loading…
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance | Admitted-Finance |
| 2 | Admitted-Finance | Admitted-Finance |
| 3 | Admitted-Finance | Admitted-Finance |
| 4 | Admitted-Finance | Admitted-Finance |
| 5 | Admitted-Finance | Admitted-Finance |
Tender Value
₹20.5 L
Closing Date
15 Nov 2021, 6:55 pmClosed
Executive Engineer, REW Poonch
Office of the Executive Engineer, REW Poonch
Please refer to BOQ
2021_RDPR_146852_1
e-NIT No. 215 of REW POONCH, Dated 06-11-2021
Open Tender
Civil Works
Item Rate
35 days
Poonch
Please refer to Technical Bid as per specifications of e-NIT
2 documents required · 2 mandatory
₹600
Executive Engineer, REW Poonch
Exempted
18 Nov 2021
8 Nov 2021
16 Nov 2021
8 Nov 2021
15 Nov 2021
8 Nov 2021
Amount
Providing and laying in position cement concrete of specified grade including curing but excluding the cost of centring and shuttering. All work upto plinth level with: 1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size)
15mm Cement plaster on the rough side of single or half brick wall of mix: 1 : 6 ( 1 cement : 6 fine sand)
Providing and fixing insulating board ceiling of approved quality with necessary nails etc. complete (frame work to be paid separately) : 12 mm
Cement concrete flooring 1:2:4 (1cement: 2 coarse sand: 4 graded stone aggregate) finished with a floating coat of neat cement including cement slurry and curing complete, but excluding the cost of nosing of steps etc. complete. 50 mm thick with 20mm nominal size stone aggregate.
Providing and fixing glazed shutters for doors, windows and clerestory windows using 4mm thick float glass panes including ISI marked M.S. pressed butt hinges bright finished of required size with necessary screws. Second class Kail wood
Painting with synthetic enamel paint of approved brand and manufacture to give an even shade. Two or more coats on new work
Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade on New work (two or more coats) over and including priming coat with water thinnable cement primer
Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622 of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1cement :4 coarse sand) including grouting the joints with white cement and matching pigments etc. complete job Size of tile 500x500 mm
Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS : 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer- in-Charge, in skirting, risers of steps and dados over 12 mm thick bed of cement mortar 1:3 ( 1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3 kg per sqm, including pointing in white cement mixed with pigment of matching shade complete job.
Carriage of Stone 500 Mtr by MT by H.L
Carriage of Cement by 10 km by MT & 2km by HL
Carriage of Sand -Bajri by 20 km by MT & 2 Km by HL
Electrification
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm2 FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduct with modular switch modular plate suitable GI box @ earthing the point with 1.5 mm2 FRLS PVC insulated copper conductor single core cable etc. as required.
Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit alongwith 1 No 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required.
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required 1.14.2 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire
Supplying and fixing following way, single pole and neutral, sheet MCB distribution board, 240 volts, on surface/ recess,complete with tinned copper bus bar, neutral bus bar, earth bar,din bar, interconnections, powder painted including earthing etc as required.( But without MCB/RCCB/Isolator) 6 way , Double door
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 5/6 amps switch
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 3 pin 5/6 amp socket outlet
Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.
Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required.
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 amps modular socket outlet and 5/6 amps modular switch, connection etc. as required. (For light plugs to be used in non residential buildings).
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 amps modular socket outlet and 15/16 amps modular switch, connection etc. as required.
Supplying and fixing of follwoing 5 rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required Single pole 6/16 amps
Supplying and fixing of 9 watt LED 1 amps, ISI Marked
Supplying and fixing of follwoing rating, 240/10 KA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single pole and neutral 63 amps
Supplying of following electrical item suitable for operatingon 240/230 volts AC 50 HZ supply: Ceiling Fan 1400 mm sweep
Supplying of following electrical item suitable for operatingon 240/230 volts AC 50 HZ supply: Exhaust Fan
Supplying and fixing of Main service line 16 Sq mm twin core alumonium cable unarmoured from the LT pole upto the MCB DB including connections, etc. as required.
Installation / Construction of Sign Board (C.I.B) Showing details of project of required specifications, as directed by Engineer Incharge at Site.
NISA CONSTRUCTION
M/S MOHAMMAD ABDULLAH
SHOKAT MEHMOOD
M/S MOHD SADEEQ
HAKIM DIN
MOHD MAHROOF KHAN
mohd sadiq
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .