Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Tender Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹44.2 LAccepted-AOC BEHIND POWER HOUSE WARD NO 6 UDASAR BIKANER RAJASTHAN 334022 | BIKANER | RAJASTHAN | 334022 | L1 | Accepted-AOC Bidder fulfills the requisite criteria and being lowest | |
| 2 | L2₹46.6 L+₹1.4 L (3.06%)Rejected-Finance | L2 | Rejected-Finance Bidder fulfills the requisite criteria but not being lowest | |
| 3 | L3₹48.6 L+₹3.4 L (7.53%)Rejected-Finance SHIV BARI ROAD NEAR KASUMAL HOTEL BIKANER 334003 RAJASTHAN | BIKANER | BIKANER | RAJASTHAN | 334003 | L3 | Rejected-Finance Bidder fulfills the requisite criteria but not being lowest | |
| 4 | L4₹48.8 L+₹3.6 L (8.01%)Rejected-Finance WARD NO 40 REGRON KA MOHALLA NEAR RAVI DASS JI MANDIR SHIV BARI BIKANER RAJSTHAN 334001 | BIKANER | RAJASTHAN | 334001 | L4 | Rejected-Finance Bidder fulfills the requisite criteria but not being lowest | |
| 5 | L5₹50.2 L+₹5.0 L (11.0%)Rejected-Finance | L5 | Rejected-Finance Bidder fulfills the requisite criteria but not being lowest |
Tender Value
₹47.3 L
EMD Value
₹94,640
Closing Date
19 Jul 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
CWE AF BIKANER
HQ CWE AF BIKANER
PROVN OF WORKS SERVICES TO IMPROVE INFRASTRUCTURE FOR INSTALLATION OF ACs IN SMQs AT 263 SU AF
2023_MES_598755_2
81520/E8
Open Tender
Civil Works
Item Rate
180 days
GE AF NAL
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE AF NAL
₹94,640
Yes
7 Aug 2023
28 Jun 2023
21 Jul 2023
28 Jun 2023
19 Jul 2023
5 Jul 2023
28 Jun 2023 - 3 Jul 2023
Amount
Excavation in trenches not exc. 1.5 m wide and not exc 1.5 mtr deep in soft loose soil for laying / taking up/ taking down of cables and getting out and levelling of bottom suface to required level complete all as specified and directed.
Returning filling in, Including spreading, levelling, Watering and well ramming soil in layers not exceeding 25 cm thick complete all as specified and directed.
Removing excavated soil from site to a distance n. exc 50 mtrs away and depositing where directed at a level not exc. 1.5 mtr above the starting point complete all as specified and directed.
Material and labour for river washed, screened and dry sand for filling in trenches below and around underground cables for cushioning of cables etc. complete all as specified and directed.
Supply and fixing sub class 'B' bricks having minimum compressive strength 75 Kg/ Sqcm laid in trenches for cable protection etc. complete all as directed and directed.
Supply and laying factory made unreinforced precast concrete cable cover class HV, type -I flat size 300mmx180mmx40mm laid in trenches over underground cables complete all as specified and as directed.
Supply, laying & testing cable XLPE insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty)with stranded aluminium conductor, 11000 volts grade 95 Sqmm completed all as specified and directed.
Supply and fixing cable jointing kit for 11 KV grade cable for in door termination, heat shrink type, joint complete with jointing material and accessories suitable for 3 core XLPE, armoured, aluminium conductor cable of size 95 sqmm complete all as specified and directed. Note :- The joniting material like long sleeve for Transformer connection and other connected items will incluive in above rate
Material and labour for earthing complete with gavanised steel earth plate electrode 60 cm x 60 cm x 6.3 mm thick burried directly in ground (earth pit not less than 2.25 Mtrs below gorund level) with top edge of the plate not less than 1.5mtr beolw normal ground level, connected to galvanised earth strip 32 x 6mm size upto a distance of 7.5 mtr long by means of bolts, check nuts and washers of galvnised iron or steel all as shown in electrical plate no 5 connected to earthing test point all as specified and indicated and testing complete including execvation earth work drilling holes for electrode PCC pit & cover , funnel , water pipe , lugs etc. complete all as specified and directed.
supply , laying and testing cable XLPE insulated screened, PVC bedded galvanised steel strip or wire armoured, electric power cable heavy duty with standard aluminimum conductor 1100 Volt grade of size 400 Sqmm 3.5 core completed all as specified and directed.
supply, laying and testing cable XLPE insulated screened, PVC bedded galvanised steel strip or wire armoured, electric power cable heavy duty with standard aluminimum conductor 1100 Volt grade of size 120 Sqmm 3.5 core completed all as specified and directed.
supply , laying and testing cable XLPE insulated screened, PVC bedded galvanised steel strip or wire armoured, electric power cable heavy duty with standard aluminimum conductor 1100 Volt grade of size 50 Sqmm 3.5 core completed all as specified and directed.
supply , laying and testing cable XLPE insulated screened, PVC bedded galvanised steel strip or wire armoured, electric power cable heavy duty with standard aluminimum conductor 1100 Volt grade of size 35 Sqmm 3.5 core completed all as specified and directed.
Supply, installation, testing and commissioning, factory made and tested, LT Panel, Outdoor type, platform mounted, suitable for 415 Volts, 3 Phase and neutral, 4 wire, 50Hz, AC supply system, having bus bar chamber with insulated electrolytic Aluminium bus bars, TPN, of capacity 1000 Amps rating, installed on DMC insulators with bus bar chamber. The panel shall be dust and vermin proof, made out of 3.15 mm thick CRCA mild steel sheet and mild steel & Mounting 75 mmX 50mm Channel frame work, front openable type, with proper ferrule & cable gland, internal wiring with PVC insulated multistranded copper conductor FRLS cable of adequate size but not less than 1.5 Sqmm complete. All steel metal works including frame shall be with anticorrosive coating with seven tank process and finally epoxy polyester powder coating of Siemens grey RAL- 7035 shade. The panel shall be suitable for accommodating and inclusive of following accessories complete all as specified and directed.
Supply, installation, testing and commissioning 500 KVA, 11/0.433KV, AN, Oil Type Transformer with corrugated off circuit tap links of rating +5 to - 5% @ 2.5 %.by means of hand operated off load tap changing gear 400 KVA capacity transformer copper wound step down outdoor type, 11000/433 Volt (at no load), double wound, oil immersed naturally cooled with external cooling tubes, core type delta connected on primary side (HV) and star connected on secondary side(LV) in accordance with vector symbol Dy-II (vector group) with neutral brought on secondary side (LV side) and having tapping changing at + /-7.5% in step of +/- 2.5 %, to be changed and the maximum temperature rise shall not exceed 45 degree centigrade in oil and 55 degree centigrade in HV/LV winding when measured by resistance method after continuous full load run in ambient temp of 40 degree centigrade and the transformer shall be comprised with the following standard fittings including necessary foundation with block masonry work complete all as specified and as directed with following specifications specified in Srl No 15.01 here-in-after:- Note:- Transformer shall be double copper wound (Level -02) as per IS : 1180 (Part -1) 2014 with HT, LT cable Box.
(i) Pressure Release Valve (ii) Thermometer pocket on tank cover (iii) Oil temperature indicator with 2 contacts alarm & trip (iv) Rating plate with terminal marking (v) Two earthing terminals on tank and cover to facilitate fixing of GI earth strip (vi) Oil level gauge (vii) Oil drain filter valve (viii) Lifting lugs (ix) Oil filter hole with cap/plug including connection complete (x) Four plain solid cast steel detachable rollers (xi) First fill of transformer oil confirming to relevant IS and testing up to 60 KV di-electric strength (xii) PCC Foundation with block masonry & Plaster work as per manufacturer's instruction and as directed.
Material and labour for 80mm dia GI steel tubing light grade for protection of cable/ earth continuty conductor fixed to poles/ walls/ roof or laid in floors, road, crossing or ducts fixed with clamps, bolts nuts and wahser etc. complete all as specified and directed.
Boring of holes under road, pavement and hard standing by manual boring of 80 mm dia bore complete all as specified and directed.
Taking down chowkhats with shutter without taking off shutters from the frames (area n. exc. 1.50 sqm each) including making good the disturbed surfaces complete all as specified and directed.
Supply and fixing window/ventilator section of frame 72x55mm fixed to wall or concrete surface with MS hold fast (30x5mm section) 150mm long made of galvanised steel powder coated and section of shutter 47x20mm mullion section 72x50mm (Bse steel as per IS 513*D* quality galvanised as per IS 277 with zinc of 120gms/sqm) glazed or gauged and wire gauge shutter prepare to recieve wire mesh to the shutter. Lower half portion to be made for provision of AC's with total coated thickness of 0.6mm including powder coated grill/guard bars made of square bars 10mm dia at 150mm c/c horizontal spacimg fixed in MS flat frame (30x5mm) fixed to windows frame with screws, including 4mm thick steel glass, 0.36mm stainless steel wire cloth with 1.40mm aparture necessary fittings and all builders hardware such as handles, tower bolts & stays etc. complete all as specified and directed.
Cutting openings, through brick walls for door, window and other openings or enlarging existing openings. converting window into door openings, etc. or cutting out defective brick work for under-pinning, including providing, fixing and removing shoring, cleaning and stacking bricks,removing rubbish not exc. 50m complete all as specified and directed.
Material and labour for forming jambs, etc. to openings (to foregoing item),in CM 1:4 including Cutting,toothing and properly bonding into old work, also facing, jointing and pointing to match existing work, complete all as specified and directed.
Material and labour for rendering 15 mm thick cement plaster in cement mortar 1:6 on fair faces of brick or concrete surfaces and finishing the surfaces even and smooth without using extra cement complete all as specified and directed.
Material and labour for preparation of newly plastered surfaces of walls and applying two coats of oil bound distemper (white or tinted) over a coat of alkali resistant primer complete all as specified and directed.
Material and labour sheet metal enclosure with socket plug top, single pole and neutral enclosure with a two pin earth plug and socket complete with one MCB of capacity 20 Amps , 240 Volts complete all as specified and directed. Make:-Legrand/seimens/ schneider.
Material and labour for sub-main wiring in concealed PVC conduit with two single core 6 sqmm FRLS PVC insulated unsheathed stranded copper conductor cable drawn through including chasing cutting in any type of masonary including 20 mm dia non-metallic PVC conduit fixed in wall including 6 sq mm copper earth continuity wire, accessories and connecting to earth dolly complete. Note : 2 Run of 6 Sqmm, 1 Run of PVC conduit & 1 Run of 6 Sqmm earth cable shall be measured as single unit length
Material and labour for sub-main wiring with two single core 4 sq mm FRLSPVC insulated unsheathed stranded copper conductor cable drawn through including chasing cutting in any type of masonary including 20 mm dia non-metallic PVC conduit fixed in wall including 4 sqmm copper earth continuity wire, accessories and connecting to earth dolly for AC points complete all as specified and directed. Note : 2 Run of 4 Sqmm, 1 Run of PVC conduit & 1 Run of 4 Sqmm earth cable shall be measured as single unit length
Supply and fixing MCB SPN 40 amps 'C' series breaking capacity 10 KA, 'C, curve 240 volts, 50 Hz including necessary incoming and outgoing electric connection with suitable size of copper lugs etc. complete all as specified and directed.
Supply and fixing MCB SP 6 to 40 Amps, 'C' series breaking capacity 10 KA, 'C' curve 240 volts, 50 Hz including necessary incoming and out going electric connection with suitable size of copper lugs etc. complete all as specified and directed. Make : L&T/legrand/Havells/ABB
Supply and fixing MCB SPN DB double door with 200 Amps rated bus bar suitable for fixing 1 No SPN MCB and 02 Nos SP 240 Volts, 50 Hz including necessary incoming and out going electric connection with suitable size of copper lugs etc. complete all as specified and directed. Make : L&T/Legrand/Havells/ABB
RAJENDER ENTERPRISES
M/s Rohit Construction Co.
B.K. ROY & SONS
Aman Enterprises
SHREE GURU NANAK CONSTRUCTION COMPANY
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .