Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Tender Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹39.7 LAccepted-AOC | L1 | Accepted-AOC Being L1 bidder | |
| 2 | L2₹41.7 L+₹69,610 (1.70%)Rejected-Finance | L2 | Rejected-Finance Being other than L1 bidder | |
| 3 | L3₹42.2 L+₹1.2 L (2.99%)Rejected-Finance | L3 | Rejected-Finance Being other than L1 bidder | |
| 4 | L4₹42.3 L+₹1.3 L (3.19%)Rejected-Finance | L4 | Rejected-Finance Being other than L1 bidder | |
| 5 | L5₹45.1 L+₹4.1 L (9.97%)Rejected-Finance | L5 | Rejected-Finance Being other than L1 bidder |
Tender Value
₹42.4 L
EMD Value
₹84,700
Closing Date
11 Dec 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE 862 EWS
GE 862 EWS PIN-913862 C/o 56 APO
SPECIAL REPAIR TO BLDG NO T-60 and T-57 INCLUDING PROVN OF SEWAGE AND SEPTIC TANK UNDER AGE B/R DETT-III AND AGE E/M OF GE 862 EWS
2023_MES_627937_1
GER-68/2023-24
Open Tender
Civil Works
Item Rate
180 days
GE 862 EWS
As per tender documents
9 documents required · 9 mandatory
₹500
GE 862 EWS
₹84,700
Yes
11 Jan 2024
10 Nov 2023
13 Dec 2023
10 Nov 2023
11 Dec 2023
27 Nov 2023
Amount
Sch 'A' Part-I (B/R works) Dismantling of asbestos cement (corrugated, semi corrugated etc) sheeting in roof covering, complete all as specified and directed.
S&F for Pre-painted galvalume aluminium zinc coating GI based corrugated sheet 0.50mm thick of approved colour having tensile strength 550 MPa as in roof covering/cladding to wall fixed with self tapping screws including side and end lap as per manufacturer’s instructions, complete all as specified and directed.
S&F for Pre-painted galvalume aluminium zinc coating GI based plain sheet 0.50mm thick of approved colour having tensile strength 550 MPa as in ridges, hips, valley gutters fixed with self tapping screws including side and end lap as per manufacturer’s instructions, complete all as specified and directed.
M&L for rolled section as in main and cross beam/columns, hip and jack, rafters, purlins where connected to common rafters and running rails and guides for sliding doors, fixed with angle cleats or other connecting plates (Fe-290 Gde E-165 Quality A) complete all as specified and directed. (Note :- All structural steel work shall be painted with one shop coat of zinc chromate red oxide primer including preparation of surfaces before fabrication and rate shall be included in this item).
S&F for 4mm thick designer ceiling board in ceiling fixed with screw as per manufacturers instructions, laid over and including hot dipped galvanised iron in post grid with 24mm wide T section exposed flanges which shall be powder coated white. The frame work shall comprise of main runner made from 0.33 mm thick galvanised steel sheet of size 24 x 32 x 300 mm spaced at 1200 mm centres securely fixed to the structural soffits by approved hangers at 1200mm maximum centres. Hangers of GI wire 4 mm dia to be fixed by approved rawl plug or hanged with existing truss members. The last hanger at the end of each main runner shall not be greater than 450 mm from adjacent wall flush fittings of 1200 mm long screws Tee with (double stiching) to interlocked between main runners at 600 mm centre to centre from 1200 x 600 mm modules cross tee longer than 600 mm modules to be formed by fittings 600 mm long cross tee, tee perimeter wall angle shall be of 0.45 mm thick galvanised steel of size 19 x 19 mm and 300 mm long of white colour all as per insturctions including dismantling of existing board etc, complete all as specified and directed.
M&L for vitrified tiles light shade (premium quality) 9-10 mm thick (square/ rectangular) polished, area of each tiles n exc 0.36 sqm in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match the surface, laid over and including 15 mm thick screed bed in cement mortar 1:4, complete all as specified and directed.
M&L for vitrified tiles light shade (premium quality) 9-10 mm thick (square/ rectangular) polished, area of each tiles n exc 0.36 sqm in dados / skirting etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match the surface, laid over and including 10 mm thick rendering in cement mortar 1:3, complete all as specified and directed.
M&L for glazed ceramic coloured tiles of size 450x350x7mm thick, (premium quality) on vertical surface of wall such as dado, skirting, riser etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match the colour of tiles, laid over and including 10mm thick rendering in cement mortar 1:3, complete all as specified and as directed.
M&L for non skid ceramic coloured tiles 7 to 8 mm thick (premium quality) Square/rectangular, area of each tile exceeding 0.11 sqm but n.exc 0.18 sqm in floors etc, set and jointed in neat cement slurry and pointed in white or coloured cement to match the colour of tiles, laid over and including 15mm thick screed bed in cement mortar 1:4 complete all as specified and as directed.
Taking down chowkats or frames with shutters (without taking off shutters from frames) area exceeding 1.50 square metre and not exceeding 4.0 square metre each, complete all as specified and directed.
S&F for pressed steel door frame of size 125x60 mm with one or more rebates including necessary fixing lugs, hinges, lock and strike plate etc including back filling to chowkhats in PCC 1:3:6 type C-0 using 12.5mm graded stone agregate, complete all as specified and directed.
Taking down shutters of any description exc 2.0 sqm each, complete all as specified and directed.
S&F for factory made 2nd class hard wood 35 mm thick plain framed panelled shutters (two panel) with lock rail and panel of 9mm BWP commercial ply or 12mm veneered particle board with commercial veneering on both faces. The size of rail and stile as per IS : 1003 (Part-I), kiln seasoned and chemically pressure treated complete all as specified and directed.
S&F for factory made 35 mm thick 2nd class hard wood glazed and skelton shutters open rebated and prepared to receive glass, gauze etc (without sash bars) edges of framing plain, chamfered or rounded fitted with cut and mitred beads for securing glass, etc sizes of members of shutters as specified in SSR Part I, Section 8, clause 8.24 (a); supplied and fitted to chowkhats complete all as specified and directed.
S&F for extruded aluminium alloy handles size 150 mm fabricated type anodised (ISI marked), complete all as specified and directed.
S&F for aluminium anodized barrel tower bolts 150 mm long of extruded section (ISI marked) ,complete all as specified and directed.
M&L for 300mm long (lenth of bolt) aluminium alloy, anodised, sliding door bolt with hasp, stapl (bolt type) and fixing clips of sheets, cast or extruded section and fixing bolts and sliding bolt of extruced sections or cast aluminium alloy anodised (ISI marked) complete all as specified and directed.
Taking down chowkhats or frames (without taking off shutters from the frames) n.exc 1.5 Sqm each, complete all as specified and directed.
S&F for anodised aluminium, powder coated (minimum thickness of powder coating 50 micron) as in frame for doors, windows, ventilators with one or more rebates including joining cleat for fixing etc, complete all as specified and directed.
S&F for anodised aluminium (minimum thickness of powder coating 50 micron) door shutters, aluminium section weighing 0.55kg/m including necessary joining cleats, glazing clips, rubber neoprene packing, handles 2 Nos in each door, hinges, mortice lock, 1 Nos floor door stopper, anodised aluminium snap beading, screws etc. complete all as specified and directed.
S&F for anodised aluminium (minimum thickness of powder coating 50 micron) window and ventilator shutters, side hung type without sash bars, aluminium sections weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws, anodised aluminium fittings such as peg stays 150mm long (1 no). hinges type B-21 100mm long (2 no.) suitable handle (1no), complete all as specified and directed.
S&F for 5.5 mm thick sheet glass ordinary quality and glazing with oil putty / wooden beads in squares exc 0.50 sqm in each pane, complete all as specified and directed.
S&F for aluminium anodized grills 6.3mm dia decorative type 75mm mesh size complete all as specified and directed.
S&F for 75 mm size mortice lock of brass, vertical type, 4 levers, complete all as specified and directed.
M&L for plain ACP board 5 mm thick fixed in aluminium joinery including cutting, packing, finishing etc, complete all as specified and directed.
S&F for in repair sinks with draining board made out of stainless steel 1mm thick kitchen or laboratory with plugs, washers and wastes, including bedding in cement mortar on to dwarf wall or including fixing cantilever brackets and connecting union to pipe, overall size 915mm x 460mm bowl size 410mm x 330mm x 160mm, complete all as specified and directed.
S&F for 3 mm thick figured glass pin headed type and glazing with oil putty in squares n . exc 0.50 sqm in each pane complete all as specified and directed.
Taking down cement plaster, any description on any walls etc including raking out joints, hacking for key, scrubbing down with water etc complete all as specified and directed.
M&L for rendering 15 mm thick in cement mortar 1:6 on fair faces of brick/stone wall or concrete work, finished the surface even and smooth without using extra cement, complete all as specified and directed.
M&L for rendering 15 mm thick in cement mortar 1:4 on other than fair faces of brick wall / stone wall or concrete work, finished the surface even and smooth without using extra cement, complete all as specified and directed.
M&L for Preparation of newly plastered wall surface and applying two coats of cement base paint over 2mm thick wall care putty, complete all as specified and directed.
M&L for Preparation of newly plastered wall surface and applying two coats of distemper oil emulsion, over a coat of alkali resistant primer over and including 2mm thick wall care putty, complete all as specified and directed.
M&L for Complete removal of existing treatment and applying two coats of cement base paint over a coat of primer including 2mm thick wall care putty on old decorated or undecorated wall surface complete all as specified and directed.
M&L for washing, rubbing down and stopping of old distempered and painted wall surface including cleaning the surface by brooming down or steel wire brushing scrapping down smoke root, moulds moss and efforescent salt and trading oil, greasy spot and applying one coat of oil bound distemper wall surface complete all as specified and directed.
M&L for Complete removal of existing treatment from old plaster surface of wall and applying two coats of distemper oil emulsion over and including 2mm thick wall care putty, complete all as specified and directed.
Demolition of cement concrete of any description and in any position not otherwise specifically provided for, complete all as specified and directed.
M&L for 50mm thick plain cement concrete, type C-1, 1:3:6 (using 20mm graded crushed stone aggregate) as in plinth protection, laid in slope 1:12 from outer edge of the wall, finished even and fair, laid in alternate bays including providing 6mm wide joints throughtout thickness of plinth protection in concrete bays and in between walling and plinth protection, joints filled mastic filling comprising of one part of heated bituminous 85/25 and 3 parts of sand (all by weight), complete all as specified and directed.
M&L for preparation of new steel surface exc 10 cm width or girth and applying two coats of synthetic enamel paint, over a coat of red oxide primer, complete all as specified and as directed by Engr-in-Chagre.
M&L for preparation of old steel surface exc 10cm width or girth and applying one coat of synthetic enamel paint complete all as specified and directed.
M&L for preparation of new wooden surface exc 10cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer complete all as specified and directed.
M&L for preparation of old wooden surface exc 10cm width or girth and applying two coats of synthetic enamel paint complete all as specified and directed.
S& F for galvanised mild steel wire cloth, 0.56mm nominal dia of wire and average width of aperature 1.18mm and fixed with tinned tacks, or galvinsed wire staples , complete all as specified and directed.
Demolition of brickwork or stone / boulder masonry, built in cement mortar including all quoins, arches, pillars, etc, but excluding ashlar facings, dressed stone-work and precast concrete articles complete all as specified and directed.
M&L for brick work with sub class ‘B’ bricks, straight or curved on plan exc 6m mean radius, built in cement mortar 1:4, complete all as specified and directed.
Description all as per Srl item No. 44 above but except brick NOTE: Old brick retrieved from demolition shall be used.
M&L in repair for stainless steel curtain rod 25mm dia, medium grade pipe fixed to stainless steel framework, including all necessary welding, securing, polishing the weleded surface complete with arrangement of 02 stainless steel knobs for each rod, complete all as specified and directed.
S&F in repair for double action floor spring hydraulically regulated made up of minimum 1.25mm thick aluminium alloy sheet foundation box, main body with stainless steel cover, governing pivot made of brass, other parts made of mild steel heavy duty and fixed, complete all as specified and directed.
M&L for rendering 15 mm thick on fair faces of brick wall or concrete surface in cement mortar 1:4, mixed with and including water proofing compound as per manufracturer's instructions, finished even and smooth without using extra cement, complete all as specified and directed. (Note :- Rate of WPC will be included in the quoted rate.)
M&L for in repair edges of the chajja / roof projections in cement mortor 1:3 finished fair even smoth and applying two coats of cement base paint including removing the loose concrete / plastering, complete all as specified and directed.
M&L for cutting out cracks to "V" - section in existing roofs or terrace, cleaning out, wetting, grouting with cement and sand slurry 1:3, complete all as specfied and directed.
M&L for plain cement concrete type B-1, 1:2:4 (using 20mm graded stone aggregate) as in apex stone, coping, benching, hold fasts, water troughs, bed block, surface channel and the like including weathering, slightly rounded or chamfered angles and throating including necessary form work ,complete all as specified and directed.
M&L for complete removal of existing water proofing treatment over RCC roof, projections of any thickness, any type by stripping out old tar felt over roofs, parapets, chimney stacks etc laid horizontally or vertically including taking out layer of cement plaster etc and cleaning the surface with wire brush including removing debris from the site and depositing in low lying area where directed and providing following :- (a) Rendering 10mm thick in cement mortar 1:3 on concrete roof surfaces and finish the surface even and smooth without using extra cement including mixing water proofing compound @ 2% by weight of cement. (b) Apply a coat of bituminous primer confirming to IS-3384@ 0.4 ltr/Sqm on newly plastered surface after curing as per IS-456 and dried. (c) After the primed surface has dried, apply a coat of hot blown bitumen(85/25 penetration) confirming to IS-702 @ 1.2 Kg/Sqm of the surface. (d) Provide polymeric water proofing membrane ISI marked laid with overlaps, bonded with hot blown bitumen, and laid by torch application method, end overlaps shall not be less than 150mm and side lap 75mm. Polymeric water proofing membrane should be five layered with centre core as 90 micron high molecular high density polyethylene film, min weight 3 Kg per sqm. APP membrane shall laid acorss the slop from lowest line of sloping roof towards ridge. (e) Over the APP membrane, apply a coat of semi hot blown 85/25 penetration grade bitumen confirming to IS-702 @ 1.20 Kg/ sqm and blinded with fine sand in dry condition @ 0.50 Kg / Sqm dusted over the bitumen coat Note : (i) Care shall be taken to avoid wrinkle and air gaps while sticking membrane to the bitumen applied surface. (ii) Ponding test shall be conducted for 72 hrs as directed. (iii) Rate of WPC will be included in the quoted rate.
S&F for 15 mm bore galvanised iron GI tubing medium grade with all fittings such as bends, socket, Tee, Elbow, union, nipple, short pieces and fixed to walls, ceilings or laid in floors after taking down old unserviceable GI pipe of 15mm dia with all fittings etc complete all as specified and directed.
S&F for 20 mm bore galvanised iron GI tubing medium grade with all fittings such as bends, socket, Tee, Elbow, union, nipple, short pieces and fixed to walls, ceilings or laid in floors after taking down old unserviceable GI pipe of 20 mm dia with all fittings etc complete all as specified and directed.
M&L for stone walling of random rubble masonry, uncoursed, well bonded, bedded and soilidly hearted, built in cement mortar 1:6, complete all as specified and directed.
M&L for extra over stone walling for hammer dressing to face stones and dressing of face beds with maximum depression on face from straight edge held against the dressed surface n exc 40 mm for lime or sand stone and joints, as specified, of random rubble walling, uncoursed or brought upto courses complete all as specified and directed.
M&L for Preparation of newly plastered wall surface and applying two coats of anti bacterial paint over a coat of alkali resistant primer over and including 2mm thick wall care putty, complete all as specified and directed.
Complete removal of existing treatment of wall and applying two coats of anti bacterial paint over a coat of primer over and including 2mm thick wall care putty, complete all as specified and directed.
Complete removal of existing treatment of old plastered surface of ceiling, and applying two coats of anti bacterial paint over a coat of white cement primer over and including 2mm thick wall care putty, complete all as specified and directed.
S&F in repair vitreous China wash basin, white, flat back, size 550x 400mm including waste coupling waste pipe and brackests, complete all as specified and directed.
S&F in repair viterous china wash down water closet pan, white (pedestal pattern), including plastic water closet seat, black/white, closed pattern with recessed bottom and cover and mild steel chromium plated or aluminised hinging device, (excluding fixing bolts, flushing cistern) complete all as specified and directed.
S&F in repair 10 ltrs capacity (PVC), valve less, syphonic action type, flushing cistern, low level, white, with inlet, ball valve, float and handle including brackets, complete all as specified and directed.
S&F for vitreous China bowl type urinal flat back of size 465x355x265 mm white (minimum), with grating and union for discharge pipe excluding flushing cistern and incluidng flush type and waste pipe including providing and fixing plugs, bedding urinal against wall in cement mortar 1:2, securing urinal to plugs with and inlcuding 60mm long brass screw, pointing around urinal back in cement fixing automatice flushing cistern with bracket, flush pipe, gratting and unioun for discharge pipe (Exclusive of fixing supply pipe to flushing cistern, trap and waste pipe ),complete all as specified and directed.
S&F for 15mm chromium plated brass health faucet (hand shower) inlet length 100mm fixed to angle valve with including decorative choice flexibel pipe, wall hanger etc complete all as specified and directed.
S&F for 32mm dia PVC waste pipe 600/900mm long suitable for wash hand basin/sinks and urinals including connection complete all as specified and directed.
S&F in repair for 15mm bore swan neck pillar taps, cast copper alloy, with capstan heads, brass chromium plated, screwed down high pressure, with or without lettered 'Hot' or 'Cold' with long screwed shanks and fly-nuts, screwed for iron pipe and fixed complete, all as specified and directed.
S&F in repair for 15mm bore concealed type stop valve, cast copper alloy cromium plated, screwed down, high pressure with long shank and cup, screwed both ends for iron pipe or for unions and fixed complete, all as specified and directed.
S&F in repair for 15mm bore angle valve, cast copper alloy, fency type screwed down, high pressure with crutch or butterfly handle, chromium plated, screwed both ends for iron pipe or for unions and fixed complete, all as specified and directed.
S&F in repair for 15mm bore bib tap cast copper alloy, chromium plated, with crutch or butterfly handle, screwed down for iron pipe or for brass ferrule complete, all as specified and directed.
M&L in repair for decorative type cast brass steel finish rectangular towel rack made of 20-25mm dia 1.2mm thick polished tubes (min 4 Nos longer and 3 Nos cross), hooks, brackets and fixing arrangements of min size 600mm x 250mm, complete all as specified and directed.
S&F for 100 mm dia PTMT grating doom stainless steel with waste hole for waste pipe (minium weight 25 grm), complete all as specified and directed.
S&F in repair 32mm dia waste coupling PTMT (half or full threaded), minium weight 60 gms) fixed to stainless steel sinks, complete all as specified and directed.
S&f in repair for CP grating suitable for 75/100 mm bore floor trap and fixed with white cement complete, all as specified and directed.
S&F for in repair sinks made out of stainless steel 1mm thick kitchen or laboratory with plugs, washers and wastes, including bedding in cement mortar on to dwarf wall or including fixing cantilever brackets and connecting union to pipe, of min bowl size 600mm x 450mm x 160mm, complete all as specified and directed.
S&F in repair 110mm bore PVC (SWR) pipes single socketed in any length with rubber ring joints, laid in trenches or in floor, or as in weep hole, complete all as specified and directed.
S&F in repair 110 mm bore PVC (SWR) bend any radius, complete all as specifed and directed by Engr-in-Charge.
S&F for door closer hydraulically regulated, aluminium (extruded section body) designation No 3, universal type, suitable for door shutters of 851 to 1000mm in width and of weight between 61 to 80 Kg. Complete all as specified and directed.
Demolition of cement concrete (unreinforced) in ground floor and paving n exc 15 cm thickness below or above the ground level, complete all as specified and directed.
M&L for construction of soakage well 2.4m dia and 4.50 m deep including excavation and earth work in any type of soil, PCC 1:3:6, type C-2 in foundation, walls of honey combed masonry with top ring of M-25 concrete including intercerpting chamber and screen chamber made of brick masonry in cement mortar 1:4, RCC cover slab in M-25, interconnecting pipes of RCC, complete filled with brick bats complete all as specified and shown on drawing No CE/TD 1202/2008 SH 1/2 & 2/2 and as directed at site by Engr-in-Charge.
M&L for construction of LLDPE septic tank (conventional) of capacity 30 users designed to carry sewage and sludge water, excavation in any type of soil, PCC 1:4:8, type D-2 in foundation, vent shaft, connection etc including returning , filling of soil at sides of tank, well ramming in layers and removing excavated surplus soil to a distance not exc 50m, complete all as specified and directed by Engr-in-Charge at site.
M&L for plain cement concrete 1:3:6, type C-2 ,using 40 mm graded stone aggregate, as in concrete bed to drain pipes including packing under and haunching against the sides of pipe after they are laid and tested for 150 mm bore SGSW pipe, complete all as specified and directed.
M&L for 150 mm internal dia Salt-Glazed stone ware drain pipes grade 'A' laid in trenches over concrete bedding jointed in cement mortar (1:1) and tested ,complete all as specified and directed.
M&L for salt glazed stone ware gully trap, square or round mouthed P type, having size 150 x 150 mm fixed in position, complete all as specified and directed.
Excavating in trenches, n.exc 1.5m wide and n.exc 1.5m in depth in any type of soil for foundation, etc, or for shafts, wells, drain pipes n.exc 10 Sqm on plan and getting out, complete all as specified and directed.
Returning, filling in, trenches including spreading, levelling, watering and well ramming in layers not exceeding 25 cm thick ,complete all as specified and as directed.
Removing excavated material, not exceeding 50 m and depositing where directed at a level not exceeding 1.5 m above the starting point, complete all as specified and directed.
Sch 'A' Part-II (E/M works) Taking down carefully copper/ aluminum point wiring (light, fan, socket or power) complete, including all fittings such as switches, ceiling roses, pendants, regulators sockets etc.) removing material from the site and making good the disturbed surfaces of walls, floor or ceiling etc. to match with existing specifications, complete all as specified and directed.
M&L for point wiring for one light point/fan point controlled by one-one way switch with 1.5 Sqmm. (nominal area) single core FRLS,PVC insulated 1100 Volts, grade multi stranded unsheathed copper conductor unsheathed in and including PVC casing caping medium grade of 25mm width complete with all acessories including PVC sunk box ISI marked for mounting of switches, sockets, fan regulator etc with 3 mm thick plastic laminated sheet as top cover, and 1.5 Sqmm. (nominal area) single core FRLS, PVC insulated 1100 Volts, grade multi stranded unsheathed copper conductor cable as earth wire upto common earth and connected to earth dolly including making good the diturbed surfaces compete all as specified and directed. (Note:- Three run of copper conductor of required size and one run of casing capping measured as one unit and also colour coding of wiring to be followed as red/yellow/blue for phase, black for neutral and green for earth)
Description all as per Serial item No 88 above but for one 3 pin 6 Amp socket outlet on independent board controlled by one 6 amp switch, complete all as specified and directed.
Description all as per Serial item No 88 above but for one 3 pin 6 Amp socket outlet on same board controlled by one 6 amp switch, complete all as specified and directed.
Description all as per Serial item No 88 above but for one 3 pin 15 Amp socket outlet independent with 2.5 sqmm PVC insulated FRLS multistraind copper cable with 2.5 sqmm single core multistraind FRLS copper cable as earthling lead complete all as specified and directed.
Description all as per Serial item No 88 above but for one 3 pin 15 Amp socket outlet independent with 4 sqmm PVC insulated FRLS multistraind copper cable with 4 sqmm single core multistraind FRLS copper cable as earthling lead complete all as specified and directed.
M&L for switch piano, flush type single pole, one way 6 Amp, 240 volts complete all as specified and directed.
S&F for switch socket combination 2 in 1, 5 pin, 6 amp flush type complete all as specified and directed.
S&F for socket 2 in 1, 5 pin, 5 amp flush type complete all as specified and directed.
S&F for switch socket combination 2 in 1, 5 pin, 15 amp flush type complete all as specified and directed.
S&F for ceiling rose 3 phase/PVC/polycarbonate isolated body surface bakelite 2 to 3 terminals complete all as specified and directed.
M&L for ceiling fan regulator elctronic, flush type, hum free suitable to control speed of fan from 0 to 100% rotary type five step 240 volts AC complete all as specified and directed.
Taking down ceiling fan of any sweep of any make from its existing position, after disconnectioning electric connection for carrying out repairs including servicing, overhauling, greasing etc after cleaning the body internally and externally with cleaning agent including renewal of minor spare parts such as split pin, cater pins, coupling bolt, capacitor holder, terminal adopto, screws nuts and washers etc and replacement of spare parts / accessories such as ball bearings gun metal bushes capacitor canopy top and bottom, shakle clip assembly, rewinding of fan motor, painting and including hanging fixing back in existing location and making cable connection and testing for its satisfactory performance complete inlcuding wirting of fan number with white paint, complete all as specified and directed.
S&F for environmental friendly, ultra modern, energy saving, surface mounted, decorative oval bulk head 10 watt 6000 K inbuilt LED luminaire comprising of high brightness LEDs, IP54 protection including connecting electrically using cord flexible 3 core PVC insulated over all sheathed with flexible copper conductor of size 0.75 sqmm complete as in repair all as specified and directed.
S&F High efficacy 2'x2' recess LED flat panel light fittings 36W LED 6000K edge-lit luminaire with in and including LED lamp suitable for armstrong/grid ceiling complete for low ceiling applications complete with all accessories pre wired and including connecting up with twin core twisted flexible copper conductor cable with suitable size, complete all as specified and directed
M&L for LED Tube light fitting, complete with 1x 20 watts, 220V, AC decorative box type with driver, holder in and including LED tube light connection complete prewired and connecting electrically to ceiling rose to fitting using PVC insulated and overall sheathed flexible copper conductor cable of size 0.75 sqmm 3 core and connector block etc and necessary fixing arrangement at any height complete as in repair all as specified and directed.
S&F for lamp holder insulated body PVC/ Polycarbonate type with back plate suitable for batten/angular/pendent fittings including LED lamp 9watt complete all as specified and directed.
S&F in repair of AC socket with 20 Amp MCB with sheet metal enclosure with IP-66 and shock proof , complete all as specified and directed.
Taking down and refixing of AC from existing position including cleaning and servicing complete all as specified and directed.
M&L for sheet metal enclosure MCB distribution board, double door single pole and neutral with IP-66 protection single phase 240 volts 8 way, including suitable size copper bus bar and neutral link fixed flush in wall including chases wall for fixing DB and making good distributed wall surfaces to match with existing specification complete as in repair all as specified and directed. (Note:- MCBs will be measured separately.)
M&L for sheet metal enclosure MCB distribution board, double door single pole and neutral with IP-66 protection single phase 240 volts 12 way, including suitable size copper bus bar and neutral link fixed flush in wall including chases wall for fixing DB and making good distributed wall surfaces to match with existing specification complete as in repair all as specified and directed. (Note:- MCBs will be measured separately.)
M&L for sheet metal enclosure VTPN distribution board, double door single pole and neutral with IP-66 protection single phase 415 volts 08 way, including suitable size copper bus bar and neutral link fixed flush in wall including chases wall for fixing MCCB and incommer capacity 100 Amps and SPN as outgoing and making good distributed wall surfaces to match with existing specification complete as in repair all as specified and directed. (Note:- MCCBs will be measured separately.)
M&L for sheet metal enclosure TPN distribution board, double door single pole and neutral with IP-43 protection single phase 415 volts 04 way, including suitable size copper bus bar and neutral link fixed flush in wall including chases wall for fixing MCCB and incommer capacity 100 Amps and SPN as outgoing and making good distributed wall surfaces to match with existing specification complete as in repair all as specified and directed. (Note:- MCCBs will be measured separately.)
S&F in repair for MCCB 63 Amps triple pole adjustable thermal and magnetic setting type,16 KA breaking capacity, 415 volts, 50 Hz including taking down old unserviceable MCCB any make and provision of suitable size of lugs for existing cable, complete all as specified and directed.
M&L for MCB single pole 240 volts any rating from 6 to 32 amps, 'C' series/curve with rupturing capacity 10 KA, including providing thimble for out going cables complete all as specified and directed.
M&L for MCB single pole & neutral 240 volts any rating from 32 to 40 amps, 'C' series/curve with rupturing capacity 10 KA, including providing thimble for out going cables complete all as specified and directed.
M&L for MCB triple pole & neutral 415 volts any rating from 63, 'C' series/curve with rupturing capacity 25 KA, including providing thimble for out going cables complete all as specified and directed.
M&L for sub main wiring complete with 2 run of 4 sqmm, single core, copper conductor cable 1100 volts grade, FRLS type, PVC insulated, unsheathed, flexible, multi stranded duly colour coded cable drawn through and including PVC casing and caping of size 25mm width or above as required at site and accessories such as tee, corners,overlaping connector etc of suitable size fixed on surface of walls/roofs/ceiling and including 01 run of 4 sqmm single core, copper conductor cable 1100 volts grade, FRLS type, PVC insulated, unsheathed, flexible, multi stranded of green colour as earth continuity conductor connected to common earth dolly including removing old unserviceable sub main wiring items complete all as specified and directed. (Note : - 02 run of 4 sqmm single core copper conductor cable and one run of 4 sqmm single core copper conductor cable and 01 run of PVC casing and caping shall be measured as one unit and also colour coding of wiring to be followed as red/yellow/blue for phase, black for neutral and green for earth).
M&L for sub main wiring complete with 2 run of 6 sqmm, single core, copper conductor cable 1100 volts grade, FRLS type, PVC insulated, unsheathed, flexible, multi stranded duly colour coded cable drawn through and including PVC casing and caping of size 25mm width or above as required at site and accessories such as tee, corners,overlaping connector etc of suitable size fixed on surface of walls/roofs/ceiling and including 01 run of 6 sqmm single core, copper conductor cable 1100 volts grade, FRLS type, PVC insulated, unsheathed, flexible, multi stranded of green colour as earth continuity conductor connected to common earth dolly including removing old unserviceable sub main wiring items complete all as specified and directed. (Note : - 02 run of 6 sqmm single core copper conductor cable and one run of 6 sqmm single core copper conductor cable and 01 run of PVC casing and caping shall be measured as one unit and also colour coding of wiring to be followed as red/yellow/blue for phase, black for neutral and green for earth).
M&L for sub main wiring complete with 2 run of 10 sqmm, single core, copper conductor cable 1100 volts grade, FRLS type, PVC insulated, unsheathed, flexible, multi stranded duly colour coded cable drawn through and including PVC casing and caping of size 25mm width or above as required at site and accessories such as tee, corners,overlaping connector etc of suitable size fixed on surface of walls/roofs/ceiling and including 01 run of 10 sqmm single core, copper conductor cable 1100 volts grade, FRLS type, PVC insulated, unsheathed, flexible, multi stranded of green colour as earth continuity conductor connected to common earth dolly including removing old unserviceable sub main wiring items complete all as specified and directed. (Note : - 02 run of 10 sqmm single core copper conductor cable and one run of 10 sqmm single core copper conductor cable and 01 run of PVC casing and caping shall be measured as one unit and also colour coding of wiring to be followed as red/yellow/blue for phase, black for neutral and green for earth).
Supply,laying, jointng and testing, XLPE insulated, armoured heavy duty electric cable with aluminium conductor 1100 volts grade of size 50 sqmm 3.5 core laid in trenches, ducts, pipes, on poles and connection with necessary cables lugs, glands , complete after taking down old unserviceable cable all as specified and directed. (Note :- Excavation of earth work, removing, returning filling in, sand cushoining, concrete cable cover and protection GI pipe shall be measured and paid separetly and length of calbe shall be one length unless otherwise as directed by GE).
M&L for dry sand cushioning to underground cable, provided with a layer 8 cm thick before and 15 cm deep after laying and stretching jointing and testing the cable complete all as specified and as directed. (Note: Punned thickness of sand shall be measured and paid).
M&L for brick covering with width equal to length of brick as mechanical protection to cable using sub class ‘B’ bricks laid flat, size 230mm x 115mm x 75mm, complete all as specified and as directed.
M&L for earthing complete with galvanized steel earth plate electrode 60cm x 60cm x 6 mm thick buried directly in ground vertically to a depth not less than 2.25 mtr below ground level with top edge of the earth plate at a depth not less than 1.5 mtr below ground level, earth plate surrounded by and packed with 15 cm thick layer of char coal dust and common salt, earth lead GI wire 4.00 mm dia by means of bolts, Nuts, Check Nuts and washers of galvanized iron and thimbles and other end of the earth wire connected to main switch board and protected by galvanized iron pipe light grade 15 mm bore and water pipe 20 mm bore GI light grade with funnel and wire mesh PCC chamber in cement concrete 1:3:6 type C-2 & RCC cover all as specified & shown in elect plate No. 3 of SSR part I of 2010 including testing on completion including taking down existing unserviceable earthing complete all as specified. (Note:-Earth strip and protection pipe upto board is included in the rate quoted)
Supply,laying, jointng and testing, XLPE insulated, armoured heavy duty electric cable with aluminium conductor 1100 volts grade of size 95 Sqmm 3.5 core laid in trenches, ducts, pipes, on poles and connection with necessary cables lugs, glands , complete after taking down old unserviceable cable, complete all as specified and directed. (Note :- Excavation of earth work, removing, returning filling in, sand cushoining, concrete cable cover and protection GI pipe shall be measured and paid separetly and length of calbe shall be one length unless otherwise as directed by GE).
Supply,laying, jointng and testing, XLPE insulated, armoured heavy duty electric cable with aluminium conductor 1100 volts grade of size 35 Sqmm 3.5 core laid in trenches, ducts, pipes, on poles and connection with necessary cables lugs, glands , complete after taking down old unserviceable cable all as specified and directed. (Note :- Excavation of earth work, removing, returning filling in, sand cushoining, concrete cable cover and protection GI pipe shall be measured and paid separetly and length of calbe shall be one length unless otherwise as directed by GE).
M&L in repair for 80mm dia galvanized steel tubing (light grade) with complete all fittings such as elbow, unions, nipples, tees, bends, short pieces, connections, check-nuts, caps, plugs, diminishing pieces and flanges etc as in pole, crossing of roads, laid in trenches, fixed on walls for protection, complete all as specified and directed.
M&Lfor earthing complete with galvanised steel earth plate electrode 600x600x6mm thick, burried directly in ground (earth pit not less than 2.25m deep below ground level) with top edge of the plate not less than 1.5m below normal ground level, connected to and including 25X4mm thick galvanised iron strip by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as specified in electrical plate No 3 of SSR (2009) part-I including 40mm bore GI pipe light grade for protection of earth strip and PCC 1:2:4 type B-1 as in pit, Precast RCC earth pit cover 8 cm thick reinforced with 8mm dia TMT bars @150mm c/c and two handles, excavation and earth work in any type of soil and alternate layers of charcoal, common salt and 20mm bore galvanised medium grade steel tubing for watering with one end fixed with cast iron funnel and wire mesh and testing on completion complete after dismantling of old unserviceable earthing with all material etc all as specified and directed. (Note:-Earth strip and protection pipe upto board is included in the rate quoted)
S&F for exhaust fan of 450mm sweep, heavy duty, 1200 RPM electrical operated 230 Volts AC single phase with metal body with all accessories and louver tec complete all as specified and directed.
Supply, Laying, connecting and testing in replacement of service cable of size 16 Sqmm 2 core 1100 volts grade heavy duty cable PVC insulated stranded alumn conductor, served with an inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1 mtr apart including 4mm suspension wire or drawn in and including medium grade non metallic rigid PVC conduit as per site requirement, flat or circular after taking down old unserviceable cable including others accessories complete all as specified and directed.
S&F in repair for sheet metal enclosure for distribution board when 20 Amps MCB to be used, single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole, complete all as specified and directed
Supply,laying, jointng and testing, XLPE insulated, armoured heavy duty electric cable with aluminium conductor 1100 volts grade of size 25 Sqmm 4 core laid in trenches, ducts, pipes, on poles and connection with necessary cables lugs, glands , complete after taking down old unserviceable cable, complete all as specified and directed. (Note :- Excavation of earth work, removing, returning filling in, sand cushoining, concrete cable cover and protection GI pipe shall be measured and paid separetly and length of calbe shall be one length unless otherwise as directed by GE).
SUBASH CHANDER
BAKSHI DEVI DASS AND SONS
M/s Anil Engineers & Builders
VIJAY KUMAR SURI AND SONS
NATIONAL TRADING COMPANY
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .