Provision of Electrical Cable alongwith electrical items for Oxygen Plant at Tilak Nagar Colony Hospital under West Zone.
2021_SDMC_78315_1
EE/Elect/WestZone/2021-22/05
Open Tender
Electrical Works
Works
1 days
Rajouri Garden
Please refer Tender documents.
3 documents required · 3 mandatory
₹500
Commissioner SDMC
Exempted
1 Jun 2021
28 May 2021
1 Jun 2021
28 May 2021
31 May 2021
28 May 2021
Amount
Supply of XLPE insulated PVC Sheathed Al. Conductor Armoured Cable 1.1 KV Grade conforming to IS-7098 of following size;-
4 Core, 50 sqmm
Laying and fixing of one number PVC insulated and PVCsheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required.
Above 35 sq. mm and upto 95 sq. mm (clamped with 25x3mm MS flat clamp)
S/I/T/C of LED Tube type luminaire 20 Watt rating complete with Extruded Aluminium Batten prewired with high efficient LEDs with the following: a) Total system wattage 20 Watt + - 5 % c) Luminious efficacy lumens/watt >=95 d) Power factor >= 0.95
Supply of 1.5 sq. mm ISI marked, FRLS PVC insulated,single core copper conductor cable
SITC of Pillar box size 900mm x 450mm x 250mm suitable for mounting incomer of 250 AMCCB/Main switch 4 pole and energy meter 3phase complete with eleethoypic grade Aluminium bus bar of size 25mm x 10mm mounted on galvanized M.S. body power quoted pilferage proof SMC door duly welded with S.S. with rain com size 40mm x 40mm x 5mm x 600mm height in cutting 300 mm height below grand and covered with shode proof SMC sheet of 3 mm as required
Supply of 18"(450 mm) sweep 1400 rpm exhaust fan heavy duty complete with shutter blade etc as required
Supply of 1200mm sweep 50 Watt, Energy saver ISI Marked BEE 5star rating AC Ceiling fan suitable for 230 V, 50 Hz AC supply without regulator with blades, downrod etc. complete as required
Supply of XLPE insulated PVC Sheathed Al. Conductor Armoured Cable 1.1 KV Grade conforming to IS-7098 of following size;-
4 core, 6 sqmm
Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required.
Upto 35 sq. mm (clamped with 1mm thick saddle)
Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.
Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.
Providing and fixing 25 mm X 5 mm copper strip on surface or in recess for connections etc. as required.
Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.
Group C
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed steel conduit as required.
2 X 4 sq. mm + 1 X 4 sq. mm earth wire
Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required.
100 A, 16 KA,TPMCCB
Supplying and fixing following rating, four pole, 415 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.
M/s HI TECH ELECTRICALS
AMAN ELECTRICALS
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .