Loading…
Loading…
Tender Value
Refer Docs
EMD Value
₹9,500
Closing Date
29 Sept 2026, 5:00 pm2d left
Executive Engineer, PWD.
Office of the Executive Engineer, PWD., Buildings Construction and Maintenance Division, PWD Campus, Big Bazaar Street, Town Hall, Coimbatore-641 001
SPECIAL REPAIRS TO PARTITION ARRANGEMENTS OF UROLOGY DEPARTMENT AT TOWER -2 BUILDING AT COIMBATORE MEDICAL COLLEGE HOSPITAL IN COIMBATORE DISTRICT
2026_PWD_703630_1
02/04N/CBE-DVN /2026-27
Open Tender
Civil Works - Buildings
Lump-sum
CMCH Coimbatore
Please refer Tender documents.
7 documents required · 7 mandatory
₹0
₹9,500
11 Sept 2026
11 Sept 2026
30 Sept 2026
11 Sept 2026
29 Sept 2026
11 Sept 2026
This is a percentage-rate BOQ. The schedule below shows estimated quantities and rates. Bidders quote a single percentage above or below the total estimated cost.
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Supplying and installation of UPVC partitions with doors shall utilize UPVC profile sections with an outer wall thickness of 2.30mm (±0.2mm), featuring an outer frame of 74mm x 60mm x 56mm, a shutter of 104mm x 60mm x 66mm, a mullion of 72mm x 60mm x 36mm, a glazing bead of 35mm x 18mm, a 20mm multi-chambered hollow UPVC panel section of 150mm x 20mm, and a uPVC panel bead of 19mm x 16mm. All profiles of frames, sash, and mullion shall be reinforced, where required, with 1mm thick GI steel sections. The door will be equipped with 3D hinges for enhanced weight holding capacity, and security devices such as multipoint lock systems with a cylinder lock facilitated handle, all compliant with relevant specifications and departmental directives. Glazing or uPVC panels shall be 5mm thick Plain Toughened or uPVC panel grip, held by TPE (Grey) weather-sealed gaskets. All corners and mullion joints of the frame and sash shall be mitred cut and fusion welded without mechanical joints, with all welded joints neatly trimmed to a grooved nib finish, ensuring the finished products are free from sharp edges. The complete units shall be fixed into pre-finished openings by drilling and fastening through the outer frame using high-quality fasteners, and silicon sealant shall be applied to fill the gap between the wall and the frame for a leakproof
installation and completion etc., Complete and as directed by the department officers. | 81 | M2 | 9,500 | ₹7,69,500 |
| 19 | GST 18% | 0.18 | Times | 1 | ₹0.18 |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.00 MB
BOQ_845759.xls
BOQ • 0.29 MB
TenderCondition.pdf
Additional Documents • 1.05 MB
TenderDocument.pdf
Tender Documents • 0.47 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .