Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹18.9 LAccepted-AOC 203 1 THIRUMATHI SUNDARI ILLAM CHINNAMMEN KOIL STREET AVADI CHENNAI 600 054 | CHENNAI | THIRUVALLUR | TAMIL NADU | 600054 | 1 | Accepted-AOC BEING LOWEST TENDERER AND FULFILLING ALL THE REQUISITE CRITERIA | |
| 2 | 2₹20.4 L+₹67,817 (3.45%)Rejected-Finance 63 2ND MAIN ROAD NGO COLONY ADAMBAKKAM CHENNAI 600 088 | CHENNAI | CHENNAI | TAMIL NADU | 600088 | 2 | Rejected-Finance NOT BEING LOWEST TENDERER | |
| 3 | 3₹23.6 L+₹4.0 L (20.1%)Rejected-Finance NO 229 ANGAPPAN STREET MITTANAMALAI AVADI IAF CHENNAI 600 055 | CHENNAI | CHENNAI | TAMIL NADU | 600055 | 3 | Rejected-Finance NOT BEING LOWEST TENDERER | |
| 4 | 4₹24.5 L+₹4.9 L (24.7%)Rejected-Finance 53 13 A OUTER CIRCULAR ROAD KILPAUK GARDEN COLONY CHENNAI 600 010 | CHENNAI | CHENNAI | TAMIL NADU | 600010 | 4 | Rejected-Finance NOT BEING LOWEST TENDERER | |
| 5 | 5₹24.7 L+₹5.0 L (25.4%)Rejected-Finance D NO 32 1 211 2 BOWDARA ROAD VISAKHAPATNAM 530004 | VISAKHAPATANAM | ANDHRA PRADESH | 530004 | 5 | Rejected-Finance NOT BEING LOWEST TENDERER |
Tender Value
₹35 L
EMD Value
₹70,000
Closing Date
1 Jul 2023, 6:00 pmClosed
GE Chennai
GARRISON ENGINEER FORT SAINT GEORGE CHENNAI - 600009
REPAIRS REPLACEMENT OF INTERNAL ELECTRIFICATION INCLUDING ALL FITTINGS FIXTURES AND CONNECTED WORKS AT ZONE A B AND D AREA UNDER GE CHENNAI
2023_MES_600930_1
8668/E8
Open Tender
Civil Works
Item Rate
333 days
GE Chennai
As per Tender Documents
8 documents required · 8 mandatory
₹500
GE Chennai
₹70,000
Yes
26 Aug 2023
3 Jun 2023
8 Jul 2023
3 Jun 2023
1 Jul 2023
17 Jun 2023
Amount
Taking down old unserviceable/ damaged point wiring carefully of any size and description on teak wood batten/ through pipe (light, fan, socket etc) including removal of battens, pipes/ conduits, sockets, switches, shades, ceiling fittings, bulk head fittings ceiling rose etc complete and making good disturbed portion of wall to match with the existing surface all as specified and directed.
Point wiring complete with 1.5sqmm (nominal area) PVC insulated unsheathed multistranded, (two run for Phase and Neutral) copper conductor FR & LS grade cable of 1100V grade conforming to IS -694 drawn through and including new non metallic rigid PVC conduit , 20mm bore with conduit accessories concealed In wall/ floor and fixed on ceiling/ roof etc. including new pressed steel terminal boxes 1.6mm thick, concealed in walls with plastic laminated sheet cover 3mm thick as top cover fixed with cadmium plated screws for housing the switch sockets, outlets, fan regulator etc including provn of 1.5sqmm PVC insulated unsheathed copper conductor cable of green colour for earth continuity and connecting to common earth dolly etc., complete all as specified and directed for:-
One light point controlled by one switch.
One fan point controlled by one switch through regulator.
One 3 pin socket outlet, 5amps on the same board with other switches controlled by one switch.
One 3 pin switch socket outlet, 5amps on independent board controlled by one switch.
One light point controlled by two No. 2 way switches.
One bell/ buzzer point controlled by one bell push.
Point wiring complete with 2.5sqmm (nominal area) PVC insulated unsheathed multistranded, (two run for Phase and Neutral) copper conductor FR & LS grade cable of 1100V grade conforming to IS-694 drawn through and including new non metallic rigid PVC conduit , 20mm bore with conduit accessories concealed In wall/ floor and fixed on ceiling/ roof etc, including pressed steel terminal boxes 1.6mm thick, concealed in walls with plastic laminated sheet cover 3mm thick as top cover fixed with cadmium plated screws for housing the switch sockets, outlets, fan regulator etc including provn of 2.5sqmm PVC insulated unsheathed copper conductor cable of green colour for earth continuity and connecting to common earth dolly complete all as specified for one socket outlet (plug point) three pin 15 Amps controlled by one switch 15 Amps on independent board complete all as specified and directed.
Point wiring complete with 1.5sqmm (nominal area) PVC insulated unsheathed multistranded, (two runs for Phase and Neutral) copper conductor FR & LS grade cable of 1100V grade conforming to IS -694 drawn through and including new PVC casing and capping of size 25 x 16mm with accessories fixed on surfaces of wall/ floor and fixed on ceiling/ roof etc, including pressed steel terminal boxes 1.6mm thick, concealed in walls with plastic laminated sheet cover 3mm thick as top cover fixed with cadmium plated screws for housing the switch sockets, outlets, fan regulator etc including provn of 1.5sqmm PVC insulated unsheathed copper conductor cable of green colour for earth continuity and connecting to common earth dolly complete all as specified and directed for:-
One light point controlled by one switch
One fan point controlled by one switch through regulator.
One 3 pin socket outlet, 5amps on the same board with other switches controlled by one switch.
One 3 pin switch socket outlet, 5 Amps on independent board controlled by one switch
One bell/ buzzer point controlled by one bell push
Point wiring complete with 2.5sqmm (nominal area) PVC insulated unsheathed multistranded, (two runs for Phase and Neutral) copper conductor FR & LS grade cable of 1100V grade conforming to IS -694 drawn through and including PVC casing and capping of suitable size with accessories fixed on surfaces of wall/ floor and fixed on ceiling/ roof etc. including pressed steel terminal boxes 1.6mm thick, concealed in walls with plastic laminated sheet cover 3mm thick as top cover fixed with cadmium plated screws for housing the switch sockets, outlets, fan regulator etc including provn of 2.5sqmm PVC insulated unsheathed copper conductor cable of green colour for earth continuity and connecting to common earth dolly complete all as specified for one socket outlet (plug point) three pin 15 Amps controlled by one switch 15 Amps on independent board.
Point wiring complete with 1.5sqmm (nominal area) PVC insulated unsheathed multistranded, (two run for Phase and Neutral) copper conductor FR & LS grade cable of 1100V grade conforming to IS -694 drawn through and including non metallic rigid existing PVC conduit , 20mm bore with conduit accessories concealed In wall/ floor and fixed on ceiling/ roof etc. including new pressed steel terminal boxes 1.6mm thick, concealed in walls with plastic laminated sheet cover 3mm thick as top cover fixed with cadmium plated screws for housing the switch sockets, outlets, fan regulator etc including provn of 1.5sqmm PVC insulated unsheathed copper conductor cable of green colour for earth continuity and connecting to common earth dolly etc., complete all as specified and directed for:-
One light point controlled by one switch.
One fan point controlled by one switch through regulator.
One 3 pin socket outlet, 5amps on the same board with other switches controlled by one switch.
One 3 pin switch socket outlet, 5amps on independent board controlled by one switch.
One light point controlled by two No. 2 way switches.
One bell/ buzzer point controlled by one bell push.
Point wiring complete with 2.5sqmm (nominal area) PVC insulated unsheathed multistranded, (two run for Phase and Neutral) copper conductor FR & LS grade cable of 1100V grade conforming to IS-694 drawn through and including non metallic rigid existing PVC conduit 20mm bore with conduit accessories concealed In wall/ floor and fixed on ceiling/ roof etc, including pressed steel terminal boxes 1.6mm thick, concealed in walls with plastic laminated sheet cover 3mm thick as top cover fixed with cadmium plated screws for housing the switch sockets, outlets, fan regulator etc including provn of 2.5sqmm PVC insulated unsheathed copper conductor cable of green colour for earth continuity and connecting to common earth dolly complete all as specified for one socket outlet (plug point) three pin 15 Amps controlled by one switch 15 Amps on independent board complete all as specified and directed.
Point wiring complete with 1.5sqmm (nominal area) PVC insulated unsheathed multistranded, (two run for Phase and Neutral) copper conductor FR & LS grade cable of 1100V grade conforming to IS -694 drawn through and including new non metallic rigid PVC conduit fixed on surface, 20mm bore with conduit accessories concealed In wall/ floor and fixed on ceiling/ roof etc. including new pressed steel terminal boxes 1.6mm thick, concealed in walls with plastic laminated sheet cover 3mm thick as top cover fixed with cadmium plated screws for housing the switch sockets, outlets, fan regulator etc including provn of 1.5sqmm PVC insulated unsheathed copper conductor cable of green colour for earth continuity and connecting to common earth dolly etc., complete all as specified and directed for:-
One light point controlled by one switch.
One fan point controlled by one switch through regulator.
One 3 pin socket outlet, 5amps on the same board with other switches controlled by one switch.
One 3 pin switch socket outlet, 5amps on independent board controlled by one switch.
One light point controlled by two No. 2 way switches.
One bell/ buzzer point controlled by one bell push.
Point wiring complete with 2.5sqmm (nominal area) PVC insulated unsheathed multistranded, (two run for Phase and Neutral) copper conductor FR & LS grade cable of 1100V grade conforming to IS-694 drawn through and including new non metallic rigid PVC conduit, fixed on surface, 20mm bore with conduit accessories concealed In wall/ floor and fixed on ceiling/ roof etc, including pressed steel terminal boxes 1.6mm thick, concealed in walls with plastic laminated sheet cover 3mm thick as top cover fixed with cadmium plated screws for housing the switch sockets, outlets, fan regulator etc including provn of 2.5sqmm PVC insulated unsheathed copper conductor cable of green colour for earth continuity and connecting to common earth dolly complete all as specified for one socket outlet (plug point) three pin 15 Amps controlled by one switch 15 Amps on independent board complete all as specified and directed.
Modular metal fush box 1x2 module complete all as specified and directed.
Modular metal fush box 1x4 module complete all as specified and directed.
Modular metal fush box 1x6 module complete all as specified and directed.
Modular cover plate with frame 2 module complete all as specified and directed.
Modular cover plate with frame 4 module complete all as specified and directed.
Modular cover plate with frame 6 module complete all as specified and directed.
Modular switches 1 way suitable for type AC 240V, 6 Amps, 1 module complete all as specified and directed.
Modular switches 1 way suitable for type AC 240V, 16 Amps, 1 module complete all as specified and directed.
Modular switches 2 way suitable for type AC 240V, 6 Amps, 1 module complete all as specified and directed.
Modular sockets suitable for type AC 240V, 6 Amps, 2/3 pin combined, 2 modules complete all as specified and directed.
Modular power sockets suitable for type AC 240V, 16 Amps, 2/3 pin combined, 2 modules complete all as specified and directed.
Modular fan, step regulator suitable for type AC 120W, 2 modules complete all as specified and directed.
Modular bell push suitable for type AC 240V, 6 Amps complete all as specified and directed.
Call bell of multi music type, single pole, AC, 230 volts complete all as specified and directed.
Supply and fix ceiling rose PVC/ Polycarbonate body 65 x 50mm 2 to 3 terminals 230 Volts, AC Single phase all as specified and directed.
Taking down ceiling fan, carrying out repairs, by rewinding with enamelled copper wire of suitable gauge and insulating material incl varnishing with suitable class of insulating varnish, painting with two coats of synthetic enamel paint and writing MES No., incl replacement of bushes/bolt and nuts etc., and connecting with twin core flexible cord from ceiling roase and testing complete all as specified and directed.
Taking down exhaust fan, carrying out repairs, by rewinding with enamelled copper wire of suitable gauge and insulating material incl varnishing with suitable class of insulating varnish, painting with two coats of synthetic enamel paint and writing MES No., incl replacement of bushes/bolt and nuts etc., and connecting with twin core flexible cord from ceiling roase and testing complete all as specified and directed.
Taking down carefully unservicable fittings of different size and capacity complete and making good the disturbed surface of walls, floors to match with th existing surface complete all as specified and directed.
LED bulb 9 w high suitable for lamp holder , PVC/Polycarbonate type with back plate for batten fittings complete all as specified and as directed by the Engineer-in-Charge. Make : Havells/CG/Philips /Wipro
20 Watts LED light fitting, basic all purpose surface and wall mounted LED batten 20Watts with aluminium housing and integrated electronic driver including 20W LED tube - 1No on surfaces of wall or ceiling complete all as specified and as directed by the Engineer-in-Charge Make Crompton Cat No CCS-103-20-65-SL-DP-NWH or equivalent of make Philips / Wipro/Havells
Supply and fix 10Watts LED light fitting, basic all purpose surface and wall mounted LED batten 10Watts with aluminium housing and integrated electronic driver including 10W LED tube - 1No on surfaces of wall or ceiling complete all as specified and as directed by the Engineer-in-Charge Make Crompton Cat No CCS-103-10-65-SL-DP-NWH or equivalent of make Philips /Wipro/Havells
Supply and fix 36 Watts 2X2 ceiling light Environment friendly, new generation, aesthatically, ultra modern designed Recess mounting luminaire with high brightness SMD LEDs as light source suitable for Armstrong Grid false ceiling complete all as specified and as directed by the Engineer-in-Charge Make Crompton Cat No LCTRLF7-36-CDL or equivalent of make Philips /Wipro/Havells
Fixing only 5 Amp switch and socket modular type by using suitable pressed steel terminal boxes concealed in wall including cover plate and frame connecting complete all as specified and as directed.
Fixing only 15 Amp switch and socket modular type by using suitable pressed steel terminal boxes concealed in wall including cover plate and frame connecting complete all as specified and as directed.
Fixing only 15 Amp switch and socket Piano type by using suitable pressed steel terminal boxes concealed in wall including cover plate and frame connecting complete all as specified and as directed.
Fixing only 6 Amp two way switch modular type by using suitable pressed steel terminal boxes concealed in wall including cover plate and frame connecting complete all as specified and as directed. Note ( Item No 32 to 35 ) :- Only switch and socket will be issued by dept "free for fixing" only.
Fixing only 15 Amp plug top connecting complete. Note: Plug top will be issued by dept "free for fixing" only.
Fixing only MCB single pole 6 Amp to 40 Amp are connecting properly in distrubution board and checking all connection properly complete. Note :- (i) MCB will be issued by dept by dept "free for fixing" only.
Fixing only metal plug socket box complete concealed in wall properly with connections complete all as specified and directed by Engr-in-Charge. Note :- (i) Metal plug socket will be issued by dept "free for fixing" only.
Fixing only MCCB 63 Amp to 125 Amp 4 pole after taking shut down properly by Dept and checking connections properly complete all as specified and directed . Note 1:- i) MCCB will be issued by dept "free for fixing" only. Note 2 ( Item No 32 to 35, 37 to 39 ) :- i) Rate quoted deemed to be inclusive of making the surface good to match with the existing surface
Switch piano flush type 5 amps single pole one way including taking down unservicable complete all as specified and directed
Switch piano flush type 5 amps single pole two way including taking down unservicable complete all as specified and directed
Socket outlet 2 in 1, 3pin 5 amps 230 volts including taking down unservicable complete all as specified and directed
Switch piano flush type 15 amps single pole one way including taking down unservicable complete all as specified and directed
Socket outlet 3 pin, 15 Amp, flush type including taking down unservicable complete all as specified and directed
Bell push 5 amps 230 volts flush type including taking down unservicable complete all as specified and directed
Electronic fan regulator dimmer type,450w , 250 volt including taking down unservicable complete all as specified and directed
Taking down sub main wiring any type and any size complete after properly disconneting electric supply and making surface good complete all as specifided and directed
Sub main wiring complete with two runs of 4 sqmm PVC insulated unsheathed single core multistrand copper conductor cable of 1100 volts grade drawn through new non metalic rigid PVC conduit pipe concealed in wall alongwith accessories fixed on walls/floors/ceiling with one run of 4 sqmm PVC insulated unsheathed copper conductor cable as earth continuity conductor all as specified and directed. Note:- Two runs of PVC insulated cable 4 sqmm + one run 4 sqmm of earth wire and one run of conduit including accessories shall be measured as one length.
Sub main wiring complete with two runs of 6 sqmm PVC insulated unsheathed single core multistrand copper conductor cable of 1100 volts grade drawn through new non metalic rigid PVC conduit pipe concealed in wall alongwith accessories fixed on walls/floors/ceiling with one run of 6 sqmm PVC insulated unsheathed copper conductor cable as earth continuity conductor all as specified and directed. Note:- Two runs of PVC insulated cable 6 sqmm + one run 6 sqmm of earth wire and one run of conduit including accessories shall be measured as one length.
Sub main wiring complete with two runs of 10 sqmm PVC insulated unsheathed single core multistrand copper conductor cable of 1100 volts grade drawn through new non metalic rigid PVC conduit pipe concealed in wall alongwith accessories fixed on walls/floors/ceiling with one run of 10 sqmm PVC insulated unsheathed copper conductor cable as earth continuity conductor all as specified and directed. Note:- Two runs of PVC insulated cable 10 sqmm + one run 10 sqmm of earth wire and one run of conduit including accessories shall be measured as one length.
Sub main wiring complete with four runs of 10 sqmm PVC insulated unsheathed single core multistrand copper conductor cable of 1100 volts grade drawn through new non metalic rigid PVC conduit pipe concealed in wall alongwith accessories fixed on walls/floors/ceiling with one run of 10 sqmm PVC insulated unsheathed copper conductor cable as earth continuity conductor all as specified and directed . Note:- four runs of PVC insulated cable 10 sqmm + two run 10 sqmm of earth wire and one run of conduit including accessories shall be measured as one length.
Sub main wiring complete with two runs of 4 sqmm PVC insulated unsheathed single core multistrand copper conductor cable of 1100 volts grade drawn through new non metalic rigid PVC casing capping on wall alongwith accessories fixed on walls/floors/ceiling with one run of 4 sqmm PVC insulated unsheathed copper conductor cable as earth continuity conductor all as specified and directed. Note:- Two runs of PVC insulated cable 4 sqmm + one run 4 sqmm of earth wire and one run of conduit including accessories shall be measured as one length.
Sub main wiring complete with two runs of 6 sqmm PVC insulated unsheathed single core multistrand copper conductor cable of 1100 volts grade drawn through new non metalic rigid PVC casing capping on wall alongwith accessories fixed on walls/floors/ceiling with one run of 6 sqmm PVC insulated unsheathed copper conductor cable as earth continuity conductor all as specified and directed. Note:- Two runs of PVC insulated cable 4 sqmm + one run 6 sqmm of earth wire and one run of conduit including accessories shall be measured as one length.
Sub main wiring complete with two runs of 10 sqmm PVC insulated unsheathed single core multistrand copper conductor cable of 1100 volts grade drawn through new non metalic rigid PVC casing capping on wall alongwith accessories fixed on walls/floors/ceiling with one run of 10 sqmm PVC insulated unsheathed copper conductor cable as earth continuity conductor all as specified and directed. Note:- Two runs of PVC insulated cable 10 sqmm + one run 10 sqmm of earth wire and one run of casing caping including accessories shall be measured as one length.
Sub main wiring complete with four runs of 10 sqmm PVC insulated unsheathed single core multistrand copper conductor cable of 1100 volts grade drawn through new non metalic rigid PVC casing capping in wall alongwith accessories fixed on walls/floors/ceiling with one run of 10 sqmm PVC insulated unsheathed copper conductor cable as earth continuity conductor all as specified and directed. Note:- four runs of PVC insulated cable 10 sqmm + two run 10 sqmm of earth wire and one run of casing cappping including accessories shall be measured as one length.
Sub main wiring complete with two runs of 4 sqmm PVC insulated unsheathed single core multistrand copper conductor cable of 1100 volts grade drawn through non metalic rigid existing PVC conduit on wall alongwith accessories fixed on walls/floors/ceiling with one run of 4 sqmm PVC insulated unsheathed copper conductor cable as earth continuity conductor all as specified and directed . Note:- Two runs of PVC insulated cable 4 sqmm + one run 4 sqmm of earth wire including accessories shall be measured as one length.
Sub main wiring complete with two runs of 6 sqmm PVC insulated unsheathed single core multistrand copper conductor cable of 1100 volts grade drawn through non metalic rigid existing PVC conduit on wall alongwith accessories fixed on walls/floors/ceiling with one run of 6 sqmm PVC insulated unsheathed copper conductor cable as earth continuity conductor all as specified and directed . Note:- Two runs of PVC insulated cable 6 sqmm + one run 6 sqmm of earth wire including accessories shall be measured as one length.
Sub main wiring complete with two runs of 10 sqmm PVC insulated unsheathed single core multistrand copper conductor cable of 1100 volts grade drawn through non metalic rigid existing PVC conduit on wall alongwith accessories fixed on walls/floors/ceiling with one run of 10 sqmm PVC insulated unsheathed copper conductor cable as earth continuity conductor all as specified and directed. Note:- Two runs of PVC insulated cable 10 sqmm + one run 10 sqmm of earth wire including accessories shall be measured as one length.
Sub main wiring complete with four runs of 10 sqmm PVC insulated unsheathed single core multistrand copper conductor cable of 1100 volts grade drawn through non metalic rigid Existing PVC conduit in wall alongwith accessories fixed on walls/floors/ceiling with one run of 10 sqmm PVC insulated unsheathed copper conductor cable as earth continuity conductor all as specified and directed . Note:- Four runs of PVC insulated cable 10 sqmm + one run of 10 sqmm of earth wire including accessories shall be measured as one length.
Taking down MCB DB any type and any size complete after taking proper disconneting of electric supply properly and making good surface complete all as specifided and directed
S&F MCB distribution board made of CRCA sheet, powder coated paint comforming of IS 13032, double door fixed in switch boards/wall at various places of capacity 415 volt 8 way MCB DB, TPN with 200 Amp rated bus bar shall conform to IP 38 protection incluidng taking down the old one.
S&F MCB distribution board made of CRCA sheet, powder coated paint comforming of IS 13032, double door fixed in switch boards/wall at various places of capacity 415 volt 6 way MCB DB, TPN with 200 Amp rated bus bar shall conform to IP 38 protection incluidng taking down the old one.
S&F MCB distribution board made of CRCA sheet, powder coated paint comforming of IS 13032, double door fixed in switch boards/wall at various places of capacity 240volt 8 way MCB DB, SPN with 200 Amp rated bus bar shall conform to IP 38 protection incluidng taking down the old one.
S&F MCB distribution board made of CRCA sheet, powder coated paint comforming of IS 13032, double door fixed in switch boards/wall at various places of capacity 240volt 4 way MCB DB, SPN with 200 Amp rated bus bar shall conform to IP 38 protection incluidng taking down the old one.
Taking down MCB any type and any size complete after taking proper disconneting of electric supply properly and making good surface complete all as specifided and directed
S&F MCB TPN 100 Amps 415 Volts complete all as specified and directed by Engr-in Charge
S&F MCB TPN 63 Amps 415 Volts complete all as specified and directed by Engr-in Charge
S&F MCB of SPN 63 Amps 240 Volts complete all as specified and directed by Engr-in Charge
S&F MCB of rating 240 Volts, SPN 32 Amps complete all as specified and directed by Engr-in Charge
S&F MCB of Single pole of rating 6 to 32 Amps 240 Volts complete all as specified and directed by Engr-in Charge
Taking down sheet metal enclosure any type and any size complete after taking proper disconneting of electric supply properly and making good surface complete all as specifided and directed
S&F for modular 32 Amp motor starter AC switch with two module one piece including indication both red and green complete all as directed
S&F for PVC flexible hose pipe 25 mm including clamp and suitable for wiring complete all as directed
S&F for open slot PVC cable trunking width 60mm, depth 80 mm complete and fixing on wall and roof including all accessory complete all as specified and directed
S&F for open slot PVC cable trunking width 150 mm, depth 50 mm complete and fixing on wall and roof including all accessory complete all as specified and directed
Earthing complete with galvanised steel earth plate electrode 60cm x 60 cm x 6 mm thick burried directly in ground vertically to a depth not less than 2.25m deep below ground level with top edge of plate not less than 1.5m below ground level connected to GI 4 mm earth wire by means of bolts, nuts check nuts washers made of galvanised iron or steel earth wire protected by GI pipe 15 mm bore light grade connected upto switch board incl 20mm bore GI water pipe with funnel and wire mesh all as shown in electrical plate No.3 of SSR Part I including dearth chamber of PCC 1:2:4 type B1 using 20mm grade aggregate with RCC cover slab 1:2:4 type B1, 40mm thick with 15mm dia MS bar 100mm C/C both ways and 6 MM dia MS hooks complete all as specified inlcuding testing on completion.
EVEREST ENGINEERING WORKS
muthu constructions
M/s.Sai Agency
S.M.ELECTRICALS
M/s Jai Ganesh Engineering Solutions
ELSOL ENGINEERS
RK ENTERPRISES
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .