Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Tender Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹29.0 LAccepted-AOC H NO 1395 SECTOR 21 PANCHKULA 134112 HARYANA | PANCHKULA | HARYANA | 134112 | L1 | Accepted-AOC BEING LOWEST | |
| 2 | L2₹31.9 L+₹2.2 L (7.47%)Rejected-Finance | L2 | Rejected-Finance BEING NOT LOWEST | |
| 3 | L3₹32.2 L+₹2.5 L (8.50%)Rejected-AOC | L3 | Rejected-AOC BEING NOT LOWEST | |
| 4 | L4₹35.5 L+₹5.8 L (19.6%)Rejected-AOC A 306 SAISHA RESIDENCY PLOT NO 99 SECTOR 35 KAMOTHE RAIGAD MAHARASHTRA 410209 UDYAM MH 27 0136235 | RAIGAD | MAHARASHTRA | 410209 | L4 | Rejected-AOC BEING NOT LOWEST |
Tender Value
₹39.4 L
EMD Value
₹78,860
Closing Date
9 Jun 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE 863 EWS
GE 863 EWS C/O 56 APO
CONVERSION AND REROUTING OF OVER HEAD TENSION LINE INTO UNDERGROUND LOW TENSION CABLE ALONGWITH ASSOCIATED WORK AT OFFR MESS OMC SPL REPAIR REPLACEMENT TO LT SWITCH GEARS CONNECTED CABLES OTHER ACCESSORIES IN THE AREA OF AGE EM WE POOH UNDER GE 863
2023_MES_594930_1
GE863/EWS-T-28 OF 2023-24
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
Pooh
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
Yes
GE 863 EWS
₹78,860
Yes
17 Jul 2023
12 May 2023
12 Jun 2023
12 May 2023
9 Jun 2023
26 May 2023
Amount
Supplying, laying in trenches /passing through tubing/pipes or laid under floors or through walls/ducts etc , jointing and testing , Low Tension,1100 Volts grade XLPE insulated, screened PVC bedded , galvanized steel strip or wire armoured, electric power cable (heavy duty) with stranded aluminum conductor, cross sectional area 06 sqmm , 4 core, including both sides connection with and including cable lugs etc., complete all as specified and directed.
Supplying, laying in trenches /passing through tubing/pipes or laid under floors or through walls/ducts etc , jointing and testing , Low Tension,1100 Volts grade XLPE insulated, screened PVC bedded , galvanized steel strip or wire armoured, electric power cable (heavy duty) with stranded aluminum conductor, cross sectional area 10 sqmm , 4 core, including both sides connection with and including cable lugs etc., complete all as specified and directed.
Supplying, laying in trenches /passing through tubing/pipes or laid under floors or through walls/ducts etc , jointing and testing , Low Tension,1100 Volts grade XLPE insulated, screened PVC bedded , galvanized steel strip or wire armoured, electric power cable (heavy duty) with stranded aluminum conductor, cross sectional area 16 sqmm , 4 core, including both sides connection with and including cable lugs etc., complete all as specified and directed.
Supplying, laying in trenches /passing through tubing/pipes or laid under floors or through walls/ducts etc , jointing and testing , Low Tension,1100 Volts grade XLPE insulated, screened PVC bedded , galvanized steel strip or wire armoured, electric power cable (heavy duty) with stranded aluminum conductor, cross sectional area 25 sqmm , 3.5 core, including both sides connection with and including cable lugs etc., complete all as specified and directed.
Supplying, laying in trenches /passing through tubing/pipes or laid under floors or through walls/ducts etc , jointing and testing , Low Tension,1100 Volts grade XLPE insulated, screened PVC bedded , galvanized steel strip or wire armoured, electric power cable (heavy duty) with stranded aluminum conductor, cross sectional area 35 sqmm , 3.5 core, including both sides connection with and including cable lugs etc., complete all as specified and directed.
Supplying, laying in trenches /passing through tubing/pipes or laid under floors or through walls/ducts etc , jointing and testing , Low Tension,1100 Volts grade XLPE insulated, screened PVC bedded , galvanized steel strip or wire armoured, electric power cable (heavy duty) with stranded aluminum conductor, cross sectional area 50 sqmm , 3.5 core, including both sides connection with and including cable lugs etc., complete all as specified and directed.
Supplying, laying in trenches /passing through tubing/pipes or laid under floors or through walls/ducts etc , jointing and testing , Low Tension,1100 Volts grade XLPE insulated, screened PVC bedded , galvanized steel strip or wire armoured, electric power cable (heavy duty) with stranded aluminum conductor, cross sectional area 70 sqmm , 3.5 core, including both sides connection with and including cable lugs etc., complete all as specified and directed.
Supplying, laying in trenches /passing through tubing/pipes or laid under floors or through walls/ducts etc , jointing and testing , Low Tension,1100 Volts grade XLPE insulated, screened PVC bedded , galvanized steel strip or wire armoured, electric power cable (heavy duty) with stranded aluminum conductor, cross sectional area 120 sqmm , 3.5 core, including both sides connection with and including cable lugs etc., complete all as specified and directed.
Dismantling cross arms of MS channel or angle sections etc., complete ,all as specified and directed.
Dismantling insulators, any type and size, complete, all as specified and directed.
Dismantling of stay assembly , complete ,all as specified and directed.
Dismantling of ACSR conductors any size ,complete, all as specified and directed.
Supply and Fixing terminal box , made out of PVC with hinged door and locking arrangements of size 240x130x95 mm including four way connector, fixed on pole with necessary clamps, complete , all as specified and directed. Make: Sintex, Cat No- GSJB-2817 or equivelent as approved.
M&L for wiring with two runs of 1.5 sqmm single core PVC insulated FRLS cable 1100 volts grade, multistranded copper conductor cable , with one run of 1 sqmm single core PVC insulated FRLS cable 1100 volts grade with multi stranded copper coductor cable as earth continuity conductor drawn through and including 20 mm dia rigit PVC conduit and conduit accessories complete, all as specified and as directed.
Material & labour in replacement earthing complete with galvanized steel earth plate electrode 600x600x6mm thick buried directly in ground (earth pit not less than 2.25 mtr depth below ground level at any type of strata) with top edge of the earth plate not less than 1.5 mtr below normal ground level surrounded with adequate quantity of charcoal dust mixed with salt to a packed thickness of 15cm all around the plate, connected with galvanised earth strip of size 32x6 mm earth continuity conductor by means of bolts, nuts hook nuts and washers as including concrete chamber of PCC 1:3:6 type C1 (using 20mm graded stone aggregate) with fair finish, internal surface of concrete chamber shall be given internal dia 300mmx300mm, 15mm thick plaster in CM 1:4) funnel with wire mesh, RCC pit cover of 320x320x80 mm size in (1:2:4) Type B1 (using 20mm graded stone aggregate ) reinforced with XPM all as shown in electrical plate No 3 of MES SSR Part-1 (2009) and specified including and provision of earth strip of size 32x6 mm upto 7.5 mtrs long with 40 mm bore dia light grade GI pipe for protection and watering pipe of GI 20 mm bore, medium grade, including all excavation and earth work and connecting the earthing wire to panel, including testing on completion complete all as specified and directed.(Earthing for LT Panel) Note : (i) RCC pit cover shall be precast of RCC(1:2:4) type B1, 80mm thick reinforced with XPM weighing not less than 4kg/sqm in lieu of CI cover.
M & L in replacement street light bracket , made out from GI Pipe 40 mm bore, light grade 1.20 meter long bent to required shape and fixing to pole, walls etc including fixing of clamp, nut, bolt etc complete all as specified and directed.
Supply and fixing, in replacement of MCBs , SPN , 240 Volts , 6 to 32 Amps , C curve , 10 kA , complete all as specified and directed.
Supply and fixing in repair 1100 Volts grade heavy duty cable PVC insulated aluminium stranded conductor served with inner sheathing of PVC tape and overall PVC sheathed in service connection suspended by insulating hangers not more than 1 meter apart including 4mm suspension wire, one twin core cable flat or circular of size 16 Sqmm complete all as specified and directed.
Supply and fixing street light automatic control panel of capacity 6 W conforming IS/ IEC 60947-4-1 providing protection IP 54, extended wide band coil, inbuilt internaly wired and short circuit protection and 'H' class protection, necessary fixing arrangment clamps, nuts, bolts etc. complete all as specified and directed.. Make Havells Cat No- IHXTS0306A or equivelent as approved.
Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, laying underground cables/ errection of steel tubular poles / stay pit etcetc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out in hard/dense soil, complete, all as specified and directed.
M&L for laying dry bricks old size with subclass 'B' made of burnt clay best quality locally available with permissible tolerance, laid straight in trench for protection of cable complete, all as specified and directed.
Returning and filling in two parts (i) using riddled soil obtained from excavated soil upto depth of 30 cm (8 cm below cable and remaining above cable for cushioning of cable and (ii) refilling the trench of remaining depth with normal excavated soil complete all as specified and directed. Note- Excavated soil shall be riddled by using sieve to separate composite particles etc as per IS - 1255-1983 and refilling in trenches as in cable cushioning.
Removing excavated surplus material to a distance n.exc 50 m and depostimg where directed at a level n exc. 1.5 m above the starting point in any type of soil complete all as specified and directed.
S & F in replacement of GI tubing 50 mm (Light grade) laid in trenches under road or fixed to wall as mechnical protection of UG cable complete all as specified and directed.
S & F in replacement of GI tubing 100 mm (Light grade) laid in trenches under road or fixed to wall as mechnical protection of UG cable complete all as specified and directed.
Material & labour in replacement earthing complete with galvanized steel earth plate electrode 600x600x6mm thick buried directly in ground (earth pit not less than 2.25 mtr depth below ground level at any type of strata) as with top edge of the earth plate not less than 1.5mtr below normal ground level surrounded with adequate quantity of charcoal dust mixed with salt to a packed thickness of 15cm all around the plate. Connected with galvanised earth wire 4 mm dia by means of bolts, nuts hook nuts and washers as earth lead including concrete chamber of PCC 1:3:6 type C1 (using 20mm graded stone aggregate) with fair finish, internal surface of concrete chamber shall be given internal dia 300mmx300mm, 15mm thick plaster in CM 1:4) funnel with wire mesh, RCC pit cover of 320x320x80mm size in (1:2:4) Type B1 (using 20mm graded stone aggregate ) reinforced with XPM all as shown in electrical plate No 3 of MES SSR Part-1 (2009) and specified including and provision of GI wire upto 7.5 mtrs long with 15 mm bore dia light grade GI pipe for protection and watering pipe of GI 20 mm bore, medium grade, including all excavation and earth work and connecting the earthing wire to panel, including testing on completion complete all as specified and directed. Note : (i) RCC pit cover shall be precast of RCC(1:2:4) type B1, 80mm thick reinforced with XPM weighting not less than 4kg/sqm in lieu of CI cover.
Dismantling of LT over head line any type from existing LT poles complete all as specified and directed ( Five runs in one stretch/span)
Dismantling of LT pole any type and size and removing from site complete all as specified and directed
Supply and laying of GI pipe light grade galvanized with all fittings laid in trenches for cable protection of 80 mm bore all as specified and directed
M&L for Stay assembly , diameter of stay rod of not less than 20 mm, 215cm long with threaded end with suitable size of nuts & washers complete with accessories including staybows with nut bolt & washer of 14mm dia, 40cm long and stay grips & thimble of suitable size as shown in electrical plate No. 1 of SSR Part-I complete all as specified and directed. Note:(i) Rate are deemed to be inclusive of streching, tieing and tightening of stay assembly for poles including tieing frame for stay wire. (ii) Exacavation, returning filling, removal for stay wire assembly upto 2.5 mtrs including Ropes are deemed to be included in quoted rates. (iii) ladders of any size,T&P (any type), Labour Safety equipments as required at site for working on PCC pole of 9Mtrs height is deemed to be inclusive of quoted rates. (iv) Stay clamp/stay wire will be measured & paid saperately.
M&L for Loop type insulator, vitreous porcelain, white, brown or green of Large size, with overall dimensions 140mm, clearance of hole 25.5mm, including nut bolts & washers of suitable length and thickness, complete all as specified and directed.
M&L for galvanised stay wire 7/4mm for stay assembly to be fixed between stay assembly and stay clamp on PCC/MS steel pole, complete all as specified and directed.
M&L for plain cement concrete in foundations, filling and mass concrete of type D2 1:4:8 (40mm graded stone aggregate), complete all as specified and directed.
Net Contract Sum will be after deducting Sch Of Credit of Rs. 70441.50
JAMDAGNI ENGG WORKS
A P ENTERPRISES
R C TRADING COMPANY
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .