Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹22.3 LAccepted-AOC 164 197 NEWAJPUR DASAULI KURSI ROAD LUCKNOW UTTAR PRADESH 226026 | LUCKNOW | UTTAR PRADESH | 226026 | L1 | Accepted-AOC Found lowest and reasonable | |
| 2 | L2₹25.6 L+₹7,410.37 (0.29%)Rejected-Finance 93 1 PREMPURI KANKER KHERA MEERUT INDEX NO E MER 81 HQ CWE MEERUT | L2 | Rejected-Finance In order but L2 | |
| 3 | L3₹30.4 L+₹4.9 L (19.3%)Rejected-Finance | L3 | Rejected-Finance In order but L3 | |
| 4 | L4₹32.1 L+₹6.6 L (26.1%)Rejected-Finance | L4 | Rejected-Finance In order but L4 | |
| 5 | L5₹33.6 L+₹8.1 L (31.8%)Rejected-Finance 289 KASERU KHERA MAWANA ROAD MEERUT 250001 U P | MEERUT | UTTAR PRADESH | 250001 | L5 | Rejected-Finance In order but L5 |
Tender Value
Refer Docs
EMD Value
₹90,000
Closing Date
29 Apr 2024, 6:00 pmClosed
GE (U) Meerut cantt
Roorkee road Meerut Cantt
REPAIR/ MAINT OF GI/CI/DI PIPE AT PUMP HOUSE NO 10, MH AREA, SRC AND MALHOTRA ENCLAVE OF AGE E/M (WS) UNDER GE (U) E/M MEERUT CANTT.
2024_MES_649593_1
8580/E8
Open Tender
Civil Works - Water Works
Item Rate
180 days
Meerut
Please refer Tender documents.
11 documents required · 11 mandatory
₹500
GE (U) Meerut cantt
₹90,000
Yes
22 Jun 2024
8 Apr 2024
1 May 2024
8 Apr 2024
29 Apr 2024
22 Apr 2024
Amount
Excavation in trenches in soft/loose soil n.exc. 1.5M wide & n exc 1.5M deep for laying of GI/CI/DI pipe line & getting out including forming bottom surface all as specified and directed.
All as per item No. 1 above but in Hard/dense soil including cutting of roads/PCC floors etc.
Returning, filling in, trenches including spreading, levelling, watering and well ramming in layer n.exc. 250 mm in any type of soil after the pipe laid & tested complete all as specified and directed.
Removing excavated surplus soil to a distance n.exc. 50mtr and depositing where directed at a level n.exc. 1.5 m above the starting point all as specified and directed
Disconnecting and Taking out old existing CI pipe including all fitting with spigot and socket ends and lead jointed any description / grade and in any position of trenches / under floors/ on wall etc all as directed and specified for the following sizes :-
150mm dia
100mm dia
80mm dia
Disconnecting and Taking out old existing GI pipe and connecting of any description / grade and any position of trenches / under floors/ on walls etc including connecting fitting / accessoriese and fixtures such as bend, union, elbow socket etc. all as directed and specified for the following size of pipe :-
100mm dia bore
80mm dia bore
50mm dia bore
40mm dia bore
25mm dia bore
20mm dia bore
15mm dia bore
M & L for DI/CI Specials class B as per IS such as bends, tappers,any type branches cross all sockets and spigot collar caps and plug up to 250mm bore all as specified and as directed
M & L for run lead joint cast iron spigot and socket end CI pipe class and CI special fitting caulks, spun yarn and lead completed of the following sizes all as specified and directed
250mm dia bore
200mm dia bore
150mm dia bore
100mm dia bore
80mm dia bore
Dismantling the existing rubber/fiberboard gasket in joints of pipe and replacing it with New joint including nuts,bolts and washer of appropirate size complete all as required at site and directed by Engr-in-Charge
250mm dia bore
200mm dia bore
150mm dia bore
100mm dia bore
80mm dia bore
Taking down old existing sluice valve and S & F sluice valve PN-1.6 with stainless steel spindle conforming to IS-14846-2000 doubles flange and including new flanged rubber joints complete suitable for following sizes including necessary nuts, bolts with washer and rubber gasket of following sizes :-
150mm dia bore
100mm dia bore
80mm dia bore
M & L for Gun metal gate valve with iron wheel head screwed both ends for iron pipe including testing fixed in repair of following :-
50mm dia bore
40mm dia bore
25mm dia bore
20mm dia bore
15mm dia bore
Supply and fixing Bib taps 15 mm dia, PTMT any colour, high pressure screwed for iron pipes and fixed to pipe (minimum weight not less than 90 gms) fixed in repair complete all as specified & directed.
Cutting of existing CI Pipes and reducing to required length before laying in position for insertion of new tees, branches etc complete all as specified & directed. For following size :- Note :- Fittings will be measured and paid for separately under respective item
150mm dia bore
100mm dia bore
80mm dia bore
Making bore holes in GI pipe includingcutting of pipe where required for making any branch connection, repairing branch connection pipe including providing and fixing of suitable clamps of required size etc. complete for following sizes:-
50mm dia bore
40mm dia bore
25mm dia bore
20mm dia bore
M &L for Stainless steel spindle for any make and type of sluice valve fixed in repair all as specified and directed, for following sizes of sluice valves:-
250mm dia bore
200mm dia bore
150mm dia bore
100mm dia bore
80mm dia bore
S & F Gun metal/stainless steel nut for any make/type of sluice valve spindle fixed in repair all as specified and directed for following sizes of sluice valves with pressure rating upto 25 Kg/cm2 :-
250 mm bore
200mm dia bore
150mm dia bore
100mm dia bore
80mm dia bore
S & F GI tubing, medium grade, ISI marked complete with all fittings, laid in trenches or laid under floors, fixed on walls with and providing clamps etc complete all as specified & directed, for the following size:-
100mm dia bore
80mm dia bore
50mm dia bore
40mm dia bore
25mm dia bore
20mm dia bore
15 mm dia bore
Refixing only GI tubing, medium grade, including new threading old serviceable GI pipe with all fittings, laid in trenches or laid under floors, fixed on walls with and providing clamps etc complete all as specified & directed, for the following size:- (Note :- Old serviceable GI pipes shall ne used obtained from BOQ item No 06)
50mm dia bore
40mm dia bore
25mm dia bore
20 mm dia bore
15 mm dia bore
M & L for Ductile iron pipes with spigot and socket ends, centrifugally cast (spun) class K9, in any length, externally coated with metallic Zinc Coating finished with bituminous paint complete all as specified of the following bore:- Note :- Excavation, earthwork and GI clamps shall be measured and paid separately under respective items
150mm dia bore
100mm dia bore
80mm dia bore
Laying/ Refixing only in trenches, under floors or fixed to walls old serviceable CI pipe of any type and length, of following size:- Note:- Serviceable pipes retrieved under Srl item no 05 here in before shall be reused. Joints and special fitting shall be measured and paid for separately.
150mm dia bore
100mm dia bore
80mm dia bore
M&L for construction of brick masonary valve pit of size 1.00x 1.00x 1.00mm incl necessary excavation and earth work and disposal of surplus soil upto 50m, BB work in CM 1:6, 10mm plastering internally in cement mortor 1.4, PCC 1:2:4 100mm thickat bottom and top wall as copling of valve pit, MSsheet 3mm thick cover doublr door fixed in angle iron frame 35mmX35mmX5mm and 40mmX40mmX5mm at bottom for accomadating cover duly embaded in PCC coping with 25X3mm FI lugs 300mm long, one on each side, 12mm dia MS handle made to shape, locking arrangement with 1 No.Lock with two keys NAVTAL/Godrej/Harrison 50mm incl two coats of Synthetic enamel paint over a coat of red oxide zinc chrome primer on steel surface complete all as specified and shown on drawing.
All as per time No. 21 above but of size 1.2Mtr X 1.2Mtr X 1.2Mtr
M & L for cement concrete type B-1 1:2:4 (20mm grade stone aggregate) as in door cills, path and plinth protection (of any section)including chambers, weatherings, throat-ing etc and setting in mortar complete all as specified and directed.
S & F long length CI Detachable joint complete with nuts, bolts, washers and rubber ring (Set) suitable for 150mm nominal bore CI/DI pipe complete all as specified.
S & F long length CI Detachable joint complete with nuts, bolts, washers and rubber ring (Set) suitable for100mm nominal bore CI/DI pipe complete all as specified.
S & F long length CI Detachable joint complete with nuts, bolts, washers and rubber ring (Set) suitable for 80mm nominal bore CI/DI pipe complete all as specified.
S & F long length CI Detachable joint complete with nuts, bolts, washers and rubber ring (Set) suitable for 50mm nominal bore CI/DI pipe complete all as specified.
S & F of galvanized fitting like TEE, Elbow, Socket, Union, Reduser, Nipple of suitable for existing GI tubing of size up to 150mm for preventing leakage if any of make new branch connection complete all as specified and directed.
Supply only pig lead used for CI fitting joint
Supply only lead wool used for CI fitting joint
M&L for horizental boring for 180mm dia and up to 1.5m depth with hydraulic machine under any surface ( Hard/Deuse/ RCC/ Coal tar Road) for laying of pipeline including trenching if required . Cost of horizontal Bore Machine (hydraulic) & all allied itemes required for boring is deemed to be included in qnoted Rates
S&F MS work as in clamps, made to shape of flat iron of suitable size incl nuts, bolts, washers of appropriate size and painting with synthetic enamel paint in two coats over one coat of redoxide zinc chrome primer complete all as specified. Note:- Cost of fixing clamps in walls/ RCC by cutting and grouting in PCC is deemed to include in the rate quoted by tenderer.
Defence Auto Works
CHAUDHARY FURNITURE HOUSE
NITHYA INFRATECH
Shikha Enterprises
M/S JPS Electrical Engineer & Contractor
M/s RAM RATAN AND SONS
Anil Kumar Gupta
yameen enterprises
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .