Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Tender Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹37.3 LAccepted-AOC AT AMRITPUR PO NB CHILKA DIST KHURDA ODISHA 752 037 | KHORDHA | ODISHA | 752037 | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹41.7 L+₹3.6 L (9.32%)Rejected-Finance AT DUNGAMAL NH 5 PO INS CHILKA DISTT KHORDHA ODISHA 752030 | KHORDHA | ODISHA | 752030 | L2 | Rejected-Finance Other than L1 | |
| 3 | L3₹42.7 L+₹4.6 L (12.1%)Rejected-Finance AT BRAJARAJPUR PO INS CHILKA DISTT KHURDHA ODISHA 752037 | KHORDHA | ODISHA | 752037 | L3 | Rejected-Finance Other than L1 | |
| 4 | L4₹43.9 L+₹5.8 L (15.2%)Rejected-Finance AMRUITPUR AMRUITPUR INS CHILKA INS CHILKA KHURDA KHORDHA ODISHA 752037 | KHORDHA | ODISHA | 752037 | L4 | Rejected-Finance Other than L1 |
Tender Value
₹43 L
EMD Value
₹86,000
Closing Date
3 Feb 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Garrison Engineer Chilka
Garrison Engineer Chilka INS Chilka Post Khordha Odisha 752037
ADDITION/ALTERATION AND IMPROVEMENTS TO OLD SWIMMING POOL (BUILDING NO P-39) AT INS CHILKA UNDER GE CHILKA
2023_MES_574957_1
GE/CHL/8860 OF 2022-23
Open Tender
Civil Works
Item Rate
180 days
Garrison Engineer Chilka
MES Enlisted contractor of Class D Category a i
7 documents required · 7 mandatory
₹500
Yes
Garrison Engineer Chilka
₹86,000
Yes
9 Mar 2023
13 Jan 2023
6 Feb 2023
13 Jan 2023
3 Feb 2023
20 Jan 2023
13 Jan 2023 - 18 Jan 2023
Amount
Taking down existing waterproofing tratment complete of any description from brick or RCC wall and RCC slab by scrapping including removal of rubbish where directed to a distance not exceeding 100m all as specified and as directed by Engr-in-Charge.
M & L for 15 mm thick cement plaster in CM 1:4 on brick work or concrete surfaces mixed with water proofing compound 3% by weight of cement of rendering finished even and fair and smooth without using extra cement complete all as specified and directed by Engr-in-Charge.
Supply only water proofing compound.
Wire brushing and cleaning top surface of tiles, lime terracing or cement concrete, including flashings and junction of parapets, etc., and priming the surface with bitumen primer of 0.30kg/sqm penetration applied hot @ 1.7 kg per sqm, lightly tampered (area of flashings, etc., shall be added to the roof area) etc complete all as specified and directed by Engr-in -charge.
M&L for water proofing roof treatment consists of a five layered Atactic polypropylene modified polymeric membrane of minimum weighting 3Kg/Sqm and minimum 3 mm thick and reinforced with polyster non woven fabric matt (weight not less than 150 gm/Sqm ) laid with LPG torch forced application over roof surface, with a side & end overlaps of minimum 100 mm with and including priming the surfaceexcept felt with a coat of hot blown bitumen of grade 85/25 @ 1.2 Kg/Sqm each at top and bottom of the membrane as bonding material, and a coat of bituminous aluminium primer @100 gm/Sqm on top , including sealing all joints by thermo fusion, complete all as specified and directed by Engr-in-Charge.
Dismantling of floor, hearth or wall tiles including bedding coat and removal of serviceable tiles to store and debris off from the site complete all as specified & directed.
M&L for chequered cement concrete tiles 30cmx30cmx 25mm thick, set jointed and pointed in neat cement slurry in floor with grey cement and pigment fixed over and including 15mm thick screed bed in CM 1:4 etc all as specified and as directed.
M&L for Non - skid Ceramic tiles 7 to 8 mm thick (square/ rectangular) area of each coloured tile exceeding 0.06 sqm but not exceeding 0.11 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match fixed over and including 15mm thick screed bed in CM 1:4 etc complete all as specified and as directed.
M&L for Glazed ceramic coloured tiles in vertical surface 300x 200x 7 mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match fixed over and including 10mm thick backing coat in CM 1:4 etc complete all as specified and as directed.
S&F in repair 32 mm bore dia of discharge pipe waste coupling of PTMT (half or full threaded) . (Minimum weight 32mm?45gms/40mm-60 gms complete all as specified and as directed.
Material & Labour for providing and fixing stainless steel (Grade 304) railing made of hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (where ever required) and fitting the same with necessary stainless steel nuts and bolts complete, including fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of floor or the side of waist slab with suitable arrangement
M & L for Providing, cement concrete type B0 1:2:4 (12.5mm graded aggrega) in roof kerbs or mud stops, rounded or chamfered on edges in lintels upto 1.5m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, kerbs water troughs and the like including weathering, slightly rounded or chamfered angles and throating, as directed
M&L for Framed work such as grills, gratings, etc. with ends of bars shouldered and/or riveted, or forged into spikes, Lane line hooks, framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe.290.Gde-E-165
S&F in repairs Brass chromium plated shower rose of size 125 mm size with swivel joint fixing to GI pipe of 15mm dia complete all as specified and directed.
S&F in repairs Bib taps, cast copper alloy fancy type chromium plated with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule and fixed
S&F in repairs 15mm gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and complete all as specified & directed.
S&F in repairs wash hand basin vitreous china white flat back of size 580 X 450mm with brackets, complete all as specified and as directed by engr-in charge.
S&F in repairs CP pillar tap of 15 mm dia cast copper alloy fancy type screwed down high pressure, with long screwed shank and fly nuts, screwed for iron pipe and fixed complete all as specified and directed.
S&F LDPE PVC pipe 50mm dia pressure rating 6kgf/cm2 as in waste pipe to wash hand Basin/Kitchen sink /urinal all as specified as in repairs.
S&F in repairs PVC connections 15mm size with PTMT nuts and washers for 600mm long pipe complete all as specified and directed.
S&F in repairs vitreous china wash down water closet pan (Pedestal pattern) white (excld flushing cistern & Pipe) including connection to trap and flushing pipe complete all as specified & directed.
S&F in repairs PVC (EWC)seat cover white colour with flat bottom including CP hinges complete all as specified and directed.
S&F in repair PVC low level flushing cistern of 10 ltr capacity fixed including syphonic action type,ball valve, float and handle including brackets etc complete all as specified and directed.
S&F in repairs CP fancy type hand faucet with hose & hook for EWC including all necessary fitting complete all as specified. (Make : Prayag Cat No 452)
S&F in repairs vitreous china urinal bowl flat back of size 465 X 355 X 265mm white with grating,union and waste coupling including fixing plugs, beding urinal against wall in CM 1:2 securing urinals to plugs including 60mm long brass screws, pointing around urinal back in cement
S&F in repairs 100 mm dia PTMT grating doom (min. weight 25 gms) complete all as specified and directed.
S&F in repairs stop cock concealed type of 15mm dia cast copper alloy chorimum plated screwed down high presure screwed at the ends for iron pipe or union with crutch or butterfly handle screwed both ends for iron pipe or for unions fancy type chromium type complete all as specified and directed.
Taking down chowkats or frames not exceeding 1.5 Sqm each but with shutters (without taking off shutters from the frames) incl making good for removal portation all as specified and directed by Engineer-in-Charge
S & F Solid PVC door frame of size 50mmx47mm made out of 5mm plain colour PVC sheet reinforced withMS squaretube,
S&F solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails. M.S. frame shall be covered with heat moulded both side Prelam PVC sheet used PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; Panelling of plain colour PVC sheet to be fitted in the M.S. frame welded / sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement, suppling & fixing in the frame at site as per specification
S&F butt hinges,medium weight cold rolled mild steel of 100 mm.
S&F Aluminium anodised barrel tower bolts of extruded sections of size 125
S&F Aluminium handles, cast type, anodised of size 125 mm
S & F Anodised Aluminium frame for doors, windows, ventilators, fixed partitions etc., with one or more rebates with powder coating of minimum 50 micron thick including joining cleat for fixing etc., complete all as specified.
S & F Anodised Aluminium window and ventilator shutters, fixed type without sash bar with powder coating of any colour of minimum 50 micron thick, aluminum section weighing 0.55 Kg/ RM including necessary joining cleats, glazing clips, rubber packing, anodised aluminum snap beading, screws etc., complete all as specified. Note 4.8 mm thick glass or stainless steel wire cloth shall be measured and paid separately.
S & F4.8 mm thick Sheet glass, exc 0.5 Sqm each pane in ordinary quality in aluminium window including necessary fixing arrangement complete all as specified and as directed.
Renewing and repair to floor and wall glazed tiles in patches, area n exc 5 sq.m. including removing and cleaning old tiles, preparing beds and laying or setting, jointing and pointing new or old tiles complete all as specified and as directed.
Taking down and refixing old 20mm dia bore of steel tubing and connections in new or old position (Walls, ceiling, floors, etc.) complete all as specified and directed by Engr-in-Charge.
Ditto all as per Sl item No above item but 15mm bore pipe.
S&F in repairs 20 mm bore galvanized medium grade tubing fixed / laid in trenches along walls / celing etc complete all as specified and directed by Engr-in -charge.
S&F in repairs15 mm bore medium grade GI tubing including all fittings and fixed in position to walls, ceiling or under floors etc complete all as specified and directed by Engr-in -charge.
Cutting chases, pinning in, making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels etc., and cutting chases for concealed water tubing or concealed conduit wiring, etc., and making good, cutting not exceeding 10 cm girth in brick walls
Taking down cement plaster and the like from brick or stone wall and concrete surfaces including racking out joints, hacking for keys, scrubbing down with water etc., complete all as specified.
M&L for rendering 15mm thick in two layers on fair faces of stone masonry surfaces in cement mortar 1:4, including finishing even and fair without using extra cement, complete all as specified.
M&L for preparation of new plaster surface and applying two coats of distemper oil emultion on new wall surfaces and including treating with 1mm thick wall care putty chalk whiting on plastered surfaces, preparatory to distemper and a coat of primer, white or tinted complete all as specified and directed
M&L for preparing old decorated plastered surfaces including brooming down or steel wire brushing, scraping down moulds, mass and efflorescent salts and greasy spots and applying two coat of white wash on walls all as specified.
Ditto all as per above item but on ceilings
M&L for complete removal of existing treatment and applying two coats of oil bound distemper over one coat of primer including 3mm thick wall care putty on wall complete all as specified and directed.
M&L for complete removal of existing treatment on wall, chajjas & cantilever portion and making good the undulated surfaces of wall, chajjas and cantilever portion by filling of putty including rubbing, scraping & grinding make the wall surface smooth & applying two coats of weather proof acrylic emulsion paint exterior grade (100% acrylic) of silver steak shade of asian paint over a coat of primer on prepared external surfaces of walls of any description over 10 cm width/girth etc on column/pillars , RCC chajja and facia approved colour all as specified.
S&F Rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) hoisted and fixed in position of 2000 ltr capacity including provision of inlet, outlet overflow and wash out connections and taking down the unserviceable tank complete all as specified and as directed including cover
S&F Rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) hoisted and fixed in position of 1000 ltr capacity including provision of inlet, outlet overflow and wash out connections and taking down the unserviceable tank complete all as specified and as directed including cover
S&F 20mm gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and complete all as specified & directed.
S&F in repairs 110 mm dia PVC (SWR) soil, waste and vent pipes single socketed in any length with rubber ring joints, fixed to walls complete all as specified and directed
S&F in repairs 75 mm dia PVC (SWR) soil, waste and vent pipes single socketed in any length with rubber ring joints, fixed to walls complete all as specified and directed
S&F in repairs 110 mm bore PVC (SWR) bend any radius complete all as specified & directed.
S&F in repairs 75 mm bore PVC (SWR) bend any radius complete all as specified & directed.
S&F in repairs 110 mm bore PVC (SWR) bend with access door complete all as specified & directed.
S&F in repairs 75 mm bore PVC (SWR) bend with access door complete all as specified & directed.
S&F in repairs 75mm bore PVC (SWR) junction single (Single T) equal or unequal complete all as specified & directed.
S&F pre-painted galvalume aluminium zink coating GI based corrugated steel sheets 0.50 mm thick of an colour having tensile strength of 550 MPs as in roof covering/cladding to walls , fixed with self tapping screws complete all as specified and directed.
Taking down carefully copper / aluminium point wiring(light,fan,socket or power) complete along with fittings such as switches ,Sockets, ceiling rose , lamp holder ,tube light fittings and making good distrubed surfaces on walls etc.
M&L for point wiring with 1.5 sqmm PVC insulated unsheathed multistranded copper cable of FRLS grade with one run of 1.5 sqmm PVC insulated copper cable as earth continuity drawn in Concealed PVC Conduit not less than 20mm with pressed steel in concealed modular MS box duly including covered with modular sheets for mounting modular switches/Sockets, accessories such as spacers, saddles, junction boxes for one light / fan point / Bell point/5 amp socket controlled by one switch.
Ditto all as per above item but, one socket outlet, three pin, 5/6 Amp on the same board with other switches
Ditto all same as per above item but with 2.5 sqmm PVC insulated unsheathed multistranded copper FRLS grade cable with one run of 2.5 sqmm PVC insulated copper cable as earth continuity for power socket on independent board.
S&F in repairs sub main wiring with 2 runs of 4 sqmm PVC insulated unsehathed copper cable multistand 1100 V of FRLS grade with drawn in concealed PVC conduit not less than 25mm dia and one run of PVC insulated unserviceable of 4sqmm as earth continuity conductor drawn in PVC conduit with accessories complete NOTE: 3 runs of 4 Sqmm cable and 1 run of conduit will be measured as one unit i.e RM
S&F in repairs sub main wiring with 2 runs of 6 sqmm PVC insulated unsehathed copper cable multistand 1100 V of FRLS grade with drawn in concealed PVC conduit not less than 25mm dia and one run of PVC insulated serviceable of 4 sqmm as earth continuity conductor drawn in PVC conduit / casing and capping with accessories complete NOTE: 2 runs of 6 Sqmm one run of 4 Sqmm cable and 1 run of conduit will be measured as one unit i.e RM
S&F ceiling rose surface backlite 3 terminals 65X50mm 230V including PVC Box of size 3"X3" round type.
Supply and fixing switch paino, flush type, single pole, one way, 5/6 Amp, complete all as specified.
S&F switch socket out let 3 pin 5 Amps flush type, 230V.
S&F Piano type switch socket combination 2 in 1, 3 pin, 5/15 Amps, 230V.
S&F five stepped electronic socket type fan regulator as per site requirement to use in wiring 300 watt
Taking down of existing serviceable light fitting and refixing the same light in existing place all as specified and directed by Engineer-in-charge.
S&F 20 W tubelight fitting with lamp, Endura linear LED Wall and surface mounted LED batten with THD<20% polycarbonate housing & intergated driver for efficient heat dissipatio with complete fitting. Make: Havell /Bajaj/philips//CG/Surya roshini
S&F 9 W tubelight fitting with lamp, Endura linear LED Wall mounted LED batten with polycarbonate housing & intergated driver for efficient heat dissipatio with complete fitting. Make: Havell /Bajaj/philips//CG/Surya roshini
Supply and fixing in repair LED street light 25W, made up of pressure die cast aluminium housing with high power LED as lighting source and lens embeded PC cover having top opening separate driver compartment with IP 66 protection and impact resistance of IK07 complete all as specified and directed by Engineer-in-charge.
M & L Painting of ceiling fans with blade complete, in situ with synthetic enamel paint by spraying including filling cavities with filler, one coat after cleaning all dust etc all as per directed by engineer in charge
M & L Painting of exhaust fans with blade complete, in situ with synthetic enamel paint by spraying including filling cavities with filler, one coat after cleaning all dust etc all as per directed by engineer in charge
Taking down defective ceiling fan from its position and refixing the same after repairs complete all as directed by Engr-in-Charge.
Taking down defective exhaust fan380/450 mm sweep from its position and refixing with louvers the same after repairs complete all as directed by Engr-in-Charge.
Rewinding of ceiling fan motor of type 1200mm sweep & any make, with super enameled copper wire of appropriate gauge including replacement of insulating materials such as laminated lethroid paper, sleeves, necessary varnishing with golden colour varnish, greasing the bearings, replacement of missing / worn out nuts, bolts & washers, split pins etc. complete all as specified and directed by Engineer- in -Charge.
Rewinding of exhaust fan motor of type 380/450 mm sweep & any make, with super enameled copper wire of appropriate gauge including replacement of insulating materials such as laminated lethroid paper, sleeves, necessary varnishing with golden colour varnish, greasing the bearings, replacement of missing / worn out nuts, bolts & washers, split pins etc. complete all as specified and directed by Engineer- in -Charge.
Supply and fix in repair ceiling fan capacitor/condensers 2.5 mfd of approved make complete all as directed by Engineer-in-Charge. Make : NICCO/Havells/Universal.
Supply and fix in repair ceiling fan capacitor/condensers 4.0 mfd of approved make complete all as directed by Engineer-in-Charge. Make : NICCO/Havells/Universal.
Supply and fix in replacement of new ball bearing 6201 / 6202 / 6203 including metal filling, machining if required, complete all as specified. Make : SKF/NBC
Supply and fix in replacement of fan clamp with nut & bolt and rubber bush suitable for ceiling fan of any sweep and make, complete all as specified.
Supply & fix in repairs MCB DB 12 way SPN with 200 A rated bus bar, 240 Volts, Double door complete.
Supply & fix in repairs MCB DB 08 way SPN with 200 A rated bus bar, 240 Volts, Double door complete.
Supply & fix in repairs MCB DB 04 way SPN with 200 A rated bus bar, 240 Volts, Double door complete.
Supply & fix in repairs MCB DB 4 way TPN with 200 A rated bus bar,415 Volts, Double door complete.
S&F in repairs sheet metal enclosure single pole and neutral enclosure with two pin and earth plug and socket complete with one single pole MCB 20 Amps capacity.
Supply & fix MCB SP 6 to 32 Amps 240 Volts
Supply & fix 40 Amps SPN C Series MCB 240 Volts.
Supply & fix MCB four pole 63 Amps 415 volt 50 Hz.
M&L for earthing complete with galvanised steel earth plate electrode 60cm x 60 cm x 6 mm thick burried directly in ground (earth pit not less than 2.25M deep below ground level) with top edge of the plate not less than 1.5 M below ground level connected with galvanised earth wire 4 mm dia by means of bolts nuts check nuts and washers of galvanised iron to earth test point all as specified or indicated including necessary excavation and earth work any type of soil PCC (1:3:6) watering funnel, GI tubing 20 mm for watering all as specified and directed and all as shown in electrical plate No.5 of SSR part 1.
Supply and fixing in replacement 250 W LED flood light of die cast aluminum body,IP-66 including all accessories as required complete all as specified and as directed by Engr-in-Charge.
UDAYA BHANU NAYAK
ANTARYAMI PANDA AND COMPANY
PABITRA MOHAN PARIDA
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .