| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance PRAGATHI PRIDE APARTMENT 3 4 520 FLAT NO 203 BARKATPURA HYDERABAD 500 027 | HYDERABAD | TELANGANA | 500027 | Admitted-Finance |
| 2 | Admitted-Finance | Admitted-Finance |
| 3 | Rejected-Technical 2 4 136 4TH BLOCK LINGA REDDY MANSION OPP TARBUND SECUNDERABD TARBUND SECUNDERABAD TELANGANA 500009 | HYDERABAD | TELANGANA | 500009 | Rejected-Technical Tender documents received after due date and time of the tender. Refer para 11 and 16 of NIT |
Tender Value
Refer Docs
EMD Value
₹18,000
Closing Date
20 Jan 2021, 2:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
R. Ravichandran, CCE
CCE (RnD) Estates South Chandrayangutta Hyderabad - 05
Provision of A/c and Allied works in ASL Main Building at ASL/ AD complex, Hyderabad ASL/AD complex, Hyderabad
2020_DRDO_606483_1
CCERnDESTENQACASLHYD/332/20-21
Limited
Miscellaneous Works
Item Rate
365 days
Kanchanbagh
Please refer Tender documents.
4 documents required · 4 mandatory
₹500
Yes
CCE (RnD) Estates South
₹18,000
Yes
3 Feb 2021
31 Dec 2020
21 Jan 2021
31 Dec 2020
20 Jan 2021
31 Dec 2020
90 days
Supply, eretion, testing and commissioning of 2 Ton capacity Hour high wall Split type air conditioner with inverter (variable speed technology, with copper coil ecofriendly compliant refrigerent, confirming to IS:1391 (latest) with 5 star BEE rating including 3 mtr of Copper piping, standard length of condenser piping, insulation working on 230 Volts, 50Hz power supply all as directed by Engineer - In - Charge. (Make: Daikin/ Voltas/ Hitachi/ Blue Star.
Supply and Installation of 5KVA - 230Volts , 50Hz automatic voltage stabilizer with High/ Low cut off protection, with time delay, necessary mounting arrangement, cabling, plug top etc., complete all as diredted by Engineer - In- Charge.
Supply, Laying , Testing and Commissining of soft copper piping of following sizes duly insulated with 6mm thick nitrile rubber pre - formed section including fitting and supports etc., complete (This is over and above the standard length of 3mtr supplied along with item Sl No. 1).
Supply and laying 3Cx 4 Sqmm Copper flexible un-armed Cable including necessary end terminations.
Supply, Laying, testing and commissioning of 25 mm diameter HDPE drain pipe covered with 6mm thick nitrile rubber insulation including fixing accessories etc., complete.
Supply and installaion Out Door Stands
Dismantling tile work in floors and roofs laid in cement mortar including stacking material within 50 metres lead.
For Thickness of Tiles above25mm and Up to 40mm
Demolishing lime concrete manually mechanised means and disposal of material within 50 metres lead as per directions of Engineer-In-Charge.
12 mm cement plaster of mix :
1:4 (1 cement: 4 fine sand)
Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete.
Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge.
Removing dry or oil bound distemper, water proofing cement paint and the like by scrapping, sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete.
Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade : Old work (one or more coats)
Providing and applying plaster of paris putty of 2 mm thickness over plastered surface to prepare the surface even and smooth complete.
Supply and installation of Rollar Blinds of approved colour and shade complete as per directions of Engineer in charge
Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in:
SRI GANAPATHI ENTERPRISES
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .