Executive Engineer (Electrical)
Works Department, IIT Delhi, Hauz Khas, New Delhi - 110016
Providing and Fixing Electrical Installation work in Cell Biology LAB at ITEC Sonipat
2020_IIT_561056_1
IITD/WORKS(SP-3001)/2020
Open Tender
Miscellaneous Works
Works
60 days
INdian Institute of Technogy, HAuz Khas, New Delhi
Please refer Tender documents.
11 documents required · 11 mandatory
₹0
₹25,748
6 Jul 2020
27 May 2020
15 Jun 2020
27 May 2020
12 Jun 2020
27 May 2020
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed steel conduit as required. (Make: Havells / Finolex / Polycab / KEI)
2 X 4 sq. mm + 1 X 4 sq. mm earth wire
2 X 6 sq. mm + 1 X 6 sq. mm earth wire
2 X 10 sq. mm + 1 X 6 sq. mm earth wire
Supplying and fixing of 32 mm of steel conduit along with accessories in surface/recess including painting in case of surface conduit, or cutting the wall and making good the same in case of recessed conduit as required
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.
15/16 A switch (Make: Legrand / L & T / MDS / Wipro)
6 pin 15/16 A socket outlet (Make: Legrand / L & T / MDS / Wipro)
Providing and fixing FR PVC trunking without cover of (105 mm x 50 mm) size on existing wall etc. as required. (Make: Legrand / MDS / Havells / GM)
Providing and fixing following assoceries on the existing FR PVC trunking etc. as required.
FR PVC trunking cover of size (105 mm x 50 mm) (Make: Legrand / MDS / Havells / GM)
End Caps (Make: Legrand / MDS / Havells / GM)
6/8 Module arteor frame (Make: Legrand / MDS / Havells / GM)
Flate angle (Make: Legrand / MDS / Havells / GM)
Internal angle (Make: Legrand / MDS / Havells / GM)
External angle (Make: Legrand / MDS / Havells / GM)
Body Joint (Make: Legrand / MDS / Havells / GM)
Cover Joint (Make: Legrand / MDS / Havells / GM)
Modular 16/20A switch on the existing modular plate and switch box/channel including connection.(Make: Legrand / L&T / MDS / Wipro)
Modular 6/16A multi socket on the existing modular plate and switch box/channel including connection.(Make: Legrand / L&T / MDS / Wipro)
Aluminium column 74 x 80 mm- 1 compartment, Height 2.70 m, can be adapted to a ceiling height up to 3.70 m. (Make: Legrand / L&T / MDS / Wipro)
Aluminium column 74 x 80 mm- 2 compartment, Height 2.70 m, can be adapted to a ceiling height up to 3.70 m. (Make: Legrand / L&T / MDS / Wipro)
Accessory- earth Link (Make: Legrand / L&T / MDS / Wipro)
Fixing Clip (Make: Legrand / L&T / MDS / Wipro)
Providing and fixing 32A, 2P+E poles, IP 40 industial type, insulated Plug & Socket on existing wall etc. as required. (Make: Legrand / L & T / MDS / Havells)
Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required. (Make: Siemens / L&T / Havells / Legrand)
200 A,36KA,FPMCCB
250 A,36KA,FPMCCB
Supplying and fixing of 12 way (4 + 36), Double door surface/ recess mounting, vertical type, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer ) as required. (DB Should have provision for installing four pole MCCB as incomer) (Make: Havells / Siemens / Standard / L&T / Legrand)
Supplying and fixing 12 way, Double door,single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) (Make: Havells / Siemens / Standard / L&T / Legrand)
Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. (Make: Havells / Siemens / Standard / L&T / Legrand)
Single Pole
Double Pole
Supplying and fixing 63A rating, 240V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of double poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. (Make: Havells / Siemens / Standard / L&T / Legrand)
Supplying and fixing Cable End Box (Loose Wire Box) suitable for 12/8 way, Double door TPN, sheet steel, MCB distribution board, 415 Volts, on surface/ recess, complete with testing and commissioning etc. as required. (Make: Havells / Siemens / Standard / L&T / Legrand)
Supplying and fixing Cable End Box (Loose Wire Box) suitable for 14/12 way, Double door SPN, sheet steel, MCB distribution board, 240 Volts, on surface/ recess, complete with testing and commissioning etc. as required. (Make: (Make: Havells / Siemens / Standard / L&T / Legrand)
Providing and fixing 4.00 mm dia copper wire on surface or in recess for loop earthing as required.
Supplying and Laying of one number 3.5 Core Aluminium, PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of 35 sq. mm size in the existing masonry open duct as required. (Make: Havells / NICCO / Skytone / Gloster)
Supplying and installing 150 mm width X 50 mm depth X 1.6 mm thickness size of perforated painted with powder coating M.S. cable trays with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required. (Make: Industrial Perforation / Technofab / Indiana Cable Trays / Legrand)
Supplying and making end termination with brass compression gland and aluminium lugs for 3 X 35 sq. mm (28mm) size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.
Supplying, installation, testing & commissioning of 250 A 30kA SC for 1 sec Plug In/ tap off box on the existing Air Insulated Compact Type bus trunking / rising mains for use on 3 phase 4 wire 415 volts, 50Hz A.C. supply made with 1.6mm thick sheet steel enclosure (IP54) duly powder coated with provision of MCCB/ACB (but without MCCB/ACB) complete etc. as required.
Supplying and drawing of UTP 4 pair CAT 6 LAN Cable in the existing surface/ recessed Steel/ PVC conduit as required.
1 run of cable
2 run of cable
3 run cable
M/s Sharma Brothers
SUPER MOTOR WINDING & REFRIGERATION WORK
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .