diesel generators- DG Sets Experience with Gov. Required 1 Year (s) Diesel Generators- DG Sets ( 1 ) Technical Specifications Specification Specification Name Values Allowed Values OUTPUT CAPACITY RATING/PHASE Nominal Rated Capacity (KVA) 20 20 No of Phase Three Phase threephase ENGINE Make of Engine ECSORTS LIMITED N/A Model Number of Engine G20-II N/A Capacity of Engine (cc) 2140 N/A Engine Power (kWm) 18.5 N/A ISI Marking to IS :10001 for engine true N/A BIS license No
if applicable 0 N/A Type of Engine cooling Liquid Cooled Air Cooled
Liquid Cooled Type of governer Mechanical Array
Array Class of governer A1 Array
Array
Array Number of cylinders (nos) 3 N/A No of Strokes (nos) 4 N/A Rated RPM of Engine (RPM) 1500 1500
3000 1/4 Overload capacity for one hour for every 11 hours continuous running at full load (%) 10 N/A Specific Fuel Consumption (gm/kWh) 220 N/A Starting voltage (volt) 12 N/A ALTERNATOR AC GENERATOR(ALTER NATOR) Make CGL/MECCALTE N/A AC GENERATOR(ALTER NATOR) model Number G1R160SB/ECO28 1L/4 N/A Rating of AC Generator (KVA) 20 N/A Power Factor of AC generator 0.8 N/A Efficiency at rated Power factor at 75% of full Load 85.1 N/A Compliance of Alternator to IS:13364(part-1) Yes N/A Type of alternator Brushless N/A Voltage Regulation Grade VG 3 N/A Alternator IP Rating IP 23 N/A Class of Insulation H N/A CONTROL PANEL Control Panel AMF Manual
AMF IP Rating of Control Panel IP 55 N/A ACOUSTIC ENCLOSURE Sheet Thickness 1.6 1.6
1.8
2
1.2 Thickness of Foam 25 N/A Density of Foam for sound insulation 26 N/A Noise level at 1 meter (dB) 73.5 N/A BATTERY Battery Type & Specification Low Maintenance free to IS: 14257 for high cranking performance N/A Battery capacity (Ah) 88 N/A No of batteries 1 N/A TEST REPORTS Availability of Type test report for Engine from Central govt/NABL/ILAC accredited laboratory Yes N/A Test Report number ICAT/MOEF/DGTA-2013- N/A 2/4 and date(Engine) 766-1 Name and address of laboratory(Engine) ICAT MANESAR GURGAON N/A Availability of Type test report for Alternator from Central government/NABL/ILAC accredited laboratory Yes N/A Test Report number and date(Alternator) ARAI/DGTA/GCL/GPWII- PII-20/2016/5543 N/A Name and address of laboratory(Alternator) ARAI PUNE N/A DG set meet requirements of Enviro nmental(Protection) Rules 1986
in respect of noise and emission norms
as described in STC Yes N/A WARRANTY INSTALLATION & COMMISSIONING Warranty 2 Installation & Commissioning With Installation With Installation
Without Installation Agreed to STC of the Product Yes N/A * Bold specifications are the golden parameters. Consignees and Quantity S.No. Consignee Address Quantity Delivery Days 1 Anil Kumar 302012
South Western Comd Sig Regt PIN -901252 C/o 56 APO 1 15 EMD Required No ePBG Required No
8261
GEM/2018/B/1166
diesel generators- DG Sets
15 days
Rajasthan; Jaipur
PRODUCT
| Item | Delivery Location | Qty | Delivery |
|---|---|---|---|
| diesel generators- DG Sets Experience with Gov. Required 1 Year (s) Diesel Generators- DG Sets ( 1 ) Technical Specifications Specification Specification Name Values Allowed Values OUTPUT CAPACITY RATING/PHASE Nominal Rated Capacity (KVA) 20 20 No of Phase Three Phase threephase ENGINE Make of Engine ECSORTS LIMITED N/A Model Number of Engine G20-II N/A Capacity of Engine (cc) 2140 N/A Engine Power (kWm) 18.5 N/A ISI Marking to IS :10001 for engine true N/A BIS license No | - | - | - |
| if applicable 0 N/A Type of Engine cooling Liquid Cooled Air Cooled | - | - | - |
| Liquid Cooled Type of governer Mechanical Array | - | - | - |
| Array Class of governer A1 Array | - | - | - |
| Array | - | - | - |
| Array Number of cylinders (nos) 3 N/A No of Strokes (nos) 4 N/A Rated RPM of Engine (RPM) 1500 1500 | - | - | - |
| 3000 1/4 Overload capacity for one hour for every 11 hours continuous running at full load (%) 10 N/A Specific Fuel Consumption (gm/kWh) 220 N/A Starting voltage (volt) 12 N/A ALTERNATOR AC GENERATOR(ALTER NATOR) Make CGL/MECCALTE N/A AC GENERATOR(ALTER NATOR) model Number G1R160SB/ECO28 1L/4 N/A Rating of AC Generator (KVA) 20 N/A Power Factor of AC generator 0.8 N/A Efficiency at rated Power factor at 75% of full Load 85.1 N/A Compliance of Alternator to IS:13364(part-1) Yes N/A Type of alternator Brushless N/A Voltage Regulation Grade VG 3 N/A Alternator IP Rating IP 23 N/A Class of Insulation H N/A CONTROL PANEL Control Panel AMF Manual | - | - | - |
| AMF IP Rating of Control Panel IP 55 N/A ACOUSTIC ENCLOSURE Sheet Thickness 1.6 1.6 | - | - | - |
| 1.8 | - | - | - |
| 2 | - | - | - |
| 1.2 Thickness of Foam 25 N/A Density of Foam for sound insulation 26 N/A Noise level at 1 meter (dB) 73.5 N/A BATTERY Battery Type & Specification Low Maintenance free to IS: 14257 for high cranking performance N/A Battery capacity (Ah) 88 N/A No of batteries 1 N/A TEST REPORTS Availability of Type test report for Engine from Central govt/NABL/ILAC accredited laboratory Yes N/A Test Report number ICAT/MOEF/DGTA-2013- N/A 2/4 and date(Engine) 766-1 Name and address of laboratory(Engine) ICAT MANESAR GURGAON N/A Availability of Type test report for Alternator from Central government/NABL/ILAC accredited laboratory Yes N/A Test Report number and date(Alternator) ARAI/DGTA/GCL/GPWII- PII-20/2016/5543 N/A Name and address of laboratory(Alternator) ARAI PUNE N/A DG set meet requirements of Enviro nmental(Protection) Rules 1986 | - | - | - |
| in respect of noise and emission norms | - | - | - |
| as described in STC Yes N/A WARRANTY INSTALLATION & COMMISSIONING Warranty 2 Installation & Commissioning With Installation With Installation | - | - | - |
| Without Installation Agreed to STC of the Product Yes N/A * Bold specifications are the golden parameters. Consignees and Quantity S.No. Consignee Address Quantity Delivery Days 1 Anil Kumar 302012 | - | - | - |
| South Western Comd Sig Regt PIN -901252 C/o 56 APO 1 15 EMD Required No ePBG Required No | - | - | - |
Exempted
20 May 2018
18 Apr 2018
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
bid_8261.pdf
GEM_BID
termsCondition.pdf
OTHER
2657c7ca70287299b5181580fdb5a7ab.pdf
OTHER
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .