| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹11.7 LAccepted-AOC 37 A 19 3 B MADHU NAGAR AGRA UP | AGRA | AGRA | UTTAR PRADESH | 282001 | L1 | Accepted-AOC LOWEST TENDERER. | |
| 2 | L2₹13.7 L+₹1.6 L (13.2%)Rejected-AOC BLOCK NO 6 7 WING NO 3 RAHUL COMPLEX I ST BUS STAND GANESHPETH GANESHPETH NAGPUR NAGPUR MAHARASHTRA 440018 | NAGPUR | MAHARASHTRA | 440018 | L2 | Rejected-AOC NOT LOWEST TENDERER. | |
| 3 | L3₹14.1 L+₹2.1 L (17.2%)Rejected-AOC | L3 | Rejected-AOC NOT LOWEST TENDERER. |
Tender Value
₹15.0 L
EMD Value
₹30,000
Closing Date
11 Jan 2024, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
LT COL SANDEEP BENIWAL, GE
OFFICE OF GARRISON ENGINEER AIR FORCE VAYUSENA NAGAR NAGPUR- 440007
REPAIR MAINT OF COOLING APPLIANCES AT VSN, MCCF SONEGAON, 22 P and S, AKSTA AKSC NAGPUR
2023_MES_631258_1
8653
Open Tender
Civil Works
Item Rate
180 days
GE AF NAGPUR
As per tender documents
7 documents required · 7 mandatory
₹500
GE AF NAGPUR
₹30,000
15 Apr 2024
6 Dec 2023
18 Jan 2024
6 Dec 2023
11 Jan 2024
23 Dec 2023
Amount
Taking out unserviceable temp sensor and supply and fix new temperature sensor with cold assembly 230 v AC suitbale for split type ac of 1.5/2 Ton capacity of make any make model complete all as specified and directed.
Taking out unserviceable air filter and supply and fix new Air filter suitable for split type ac of 1.5/2 Ton capacity as per sample in Engr-in-charge office omplete all as specified and directed.
Taking out unserviceable copper capliary tube and Supply and fix new copper cappliary tube suitable for Split type AC's and water coolers of any make/model complete all as specified and directed.
Taking out defective capacitor and supply and fix running capacitor suitable for 1.5/2 ton 230 v split ac 36/40/45/50/55/60 mfd complete all as specified and directed.
Taking down unserviceable fan motor blade assembly & supply and fix new fan motor blade assembly for split type AC 1.5/2 Ton capacity of any make/model complete all as specified and directed.
Taking down unserviceable blower drum assembly and supply and fix new blower drum assembly suitable for 1.5/2 ton capacity of split type acs for any make/model of any make/model complete all as specified and directed.
Taking down unserviceable condenser fan motor assembly and supply and fix new condenser fan motor assembly suitable for 1.5/2 Ton split type AC of any make/model complete all as specified and directed.
Taking down unserviceable remote assembly kit and supply and fix new including PCB board suitbale for 1.5/2 TON cap split AC of any make/model complete all as specified and directed.
Taking down unserviceable PVC drain pipe & supply and fix with new PVC drain pipe with clamps set of size 40 mm dia up to 2 mtrs complete all as specified and directed.
Taking down unserviceable PVC drain pipe & supply and fix with new PVC drain pipe with clamps set of size 20 mm dia up to 2 mtrs complete all as specified and directed.
Supply only cordless remote suitbale for 1.5/2 Ton cap split type AC of any make / model complete all as specified and directed.
Taking down unserviceable power contactor & supply and fix new power contactor suitable for 1.5/2 ton split type AC of any make /model complete all as specified and directed.
Taking down unserviceable brass suction valve & supply & fix new brass suction valve 5/8" suitable for 1.5/2 ton split type AC of any make /model complete all as specified and directed.
All as per item No 13 above but brass suction valve1/2" suitable for 1.5/2 ton split type AC.
All as per item No 13 above but brass suction valve3/8" suitable for 1.5/2 ton split type AC .
All as per item No 13 above but brass suction valve1/4" suitable for 1.5/2 ton split type AC.
Taking down unserviceable brass discharge valve & supply & fix new brass discharge valve 5/8" suitable for 1.5/2 ton split type AC of any make /model complete all as specified and directed.
All as per item No 17 above but discharge valve 1/2" suitable for 1.5/2 ton split type AC .
All as per item No 17 above but brass discharge valve 3/8" suitable for 1.5/2 ton split type AC.
All as per item No 17 above but brass discharge valve 1/4" suitable for 1.5/2 ton split type AC.
Taking down unserviceable brass flare nut 5/8" supply and fix new brass flare nut 5/8" suitable for 1.5/2 ton split type AC of any make /model complete all as specified and directed.
All as per item No 21 above but brass flare nut 1/2" suitable for 1.5/2 ton split type AC.
All as per item No 21 above but brass flare nut 3/8" suitable for 1.5/2 ton split type AC.
All as per item No 21 above but brass flare nut 1/4" suitable for 1.5/2 ton split type AC .
Supply and fix PVC rigid conduit pipe 20/25 mm dia including all accessories and necessary saddles with fixing screwa, gutties etc complete all as specified and directed.
Taking down unserviceable sheet metal enclusure with earth plug socket & suply and fix sheet metal enclosure with single pole and neutral with two pin and earth plug and socket complete with one single pole mcb of 20 Amp complete all as specified and directed.
Supply and fix power unit for AC upto 2 ton, 4 module, 230 volts all as specified and directed.
Dismantling of 1.5/2 TR capacity of split type Acs and removing of existing indoor/outdoor units, including MS angular frame /MS channels, copper tube , foundation frames etc, complete and closing of holes of pipe line and drain water opening and making surface goood with plastering and painting to match the existing colour of walls complete all as specified and directed.
Fixing of 1.5/2TR capacity of split type Acs indoor& outdoor units including MS chanels, modification of copper tubes including installation foundation frames of out door unit complete and provision of opening of through holes for pipe line and drain water in brick/stone masonary wall and disturbed surface making good with plastering and painting to match existing colour of walls complete all as specified and directed. Note: Item obtained from the above ser No 28 shall be reused
Dismantling of unserviceable condensor coil complete and providing of new condensor coil of same size and quality complete suitable for split type AC of capacity 1.5/ 2 Ton of of any make /model complete all as specified and directed.
Dismantling of unserviceable knob of thermostat and providing of new knob of thermostat of same size and quality suitable for the existing split type AC of capacity 1.5/ 2 Ton of any make /model complete all as specified and directed.
Dismantling of defective compressor sealed unit from the existing AC's foundation by removing suction/ discharge line and providing of new compressor sealed unit of same size and quality from the manufacturers of ACs or of make authorised by the manufacturers of AC's, rotary type and checking (company re-oriented), system with nitrogen gas pressure, testing for leakages and vaccumisation of complete system with gas recharging with R-134a/R -22/R-32/R-410a gas as required and oil testing suitable for 1.5 Ton split AC capacity including testing complete all as specified and directed. Note : The quoted rate shal deemed to be inclusive of cost for refrigerant gas.
All as per item No. 34 above but reciprocating type
All as per item No 33 above but suitable for 2.0 Ton split AC capacity
All as per item No. 35 above but reciprocating type
Taking out of defective fan motor and providing new fan motor suitable for existing make of AC split type capacity 1/8 HP complete all as specified and directed.
All as per item No. 37 above but for fan motor suitable for AC split type of capacity 1/10 HP complete all as specified and directed.
Material and labour for taking out existing filter and capilary and replace by new filter and capillary of same size and quality suitable for split type air conditioner 1.5/ 2 TR complete all as specified and directed.
Taking out defective capacitor and supply and fix fan motor capacitir suitable for 1.5/2 ton 230 v split ac of capacity 2.5/4 mfd complete all as specified and directed.
All as per item no 40 above but of capacity 6/10 mfd.
Dismantling of existing unserviceable blower motor and providing of new blower motor double ended shaft type of same quality and charecteristics suitable for any make of 1.5/2 Ton capacity split AC of any make /model complete all as specified and directed.
Taking down of unserviceable PCB (Printed circuit board) and providing new PCB for AC of 1.5 / 2.0 Ton capacity of split AC complete all as specified and directed.
Taking out of unserviceable swing motor and providing new swing motor of same quality and charecteristics suitable for any make of AC 1.5 / 2.0 Ton split complete all as specified and directed.
Dismantling old and providing new copper tubes of size 1/4 inch for suction line including rubber tube insulations of same size for fixing AC complete all as specified and directed.
All as per item No 46 above but copper tubes of size 1/2 inch
All as per item No 46 above but copper tubes of size 3/8 inch
All as per item No 46 above but copper tubes of size 5/8 inch
Material and labour for checking of gas leakage and supply and charging of gas, including vacummising, cutting, brazing after filling again and checking of gas leakage after gas charging for the following instruments :- Make of gas : R-134 a/R-22/R-32/R-410a. Note: (i) Contractor shall be ensure that gas charging to be measured as Job and if there is any leakage during the contract period then the same will be fullfilled by the contractor without any extra cost. (ii) No tools and plants, gas cylinder shall be issued by MES.
(a) Split AC (2 Ton),
(b) Split AC (1.5 Ton)
Supply only Refrigerant (R -22) suitable for Split AC. Note: Empty cylinder shall be issued by the department.
Supply only Refrigerant (R -134a/410A/R-32) suitable for split AC. Note: Empty cylinder shall be issued by the department.
Supply & fixing pvc insulated 1100v grade of size 2.5 sqmm, 3 core pvc round sheathed insulated flexible FRLS copper cable .
Supply and fix rubber insulation suitable for existing copper pipe from indoor unit to outdoor unit of split AC 1.5/2 ton capacity and as directed.
Taking out old unserviceable split AC stand of outdoor unit and supply & fixing new stand suitable for 1.5/2 ton including necessary fixing arrangement.
Taking out of defective fan motor and providing new fan motor of same quality and characteristics suitable to any make of water cooler type capacity 1/8 HP complete all as specified and directed.
Dismantling of unserviceable thermostate and providing of new thermostate of same size and water cooler quality complete suitable of any make and model complete all as specified and directed.
M & L for checking of gas leakage and supply and charging of gas, including vacummising , cutting, brazing after filling again and checking of gas leakage after gas charging for the following instruments :- Note: (i) Contractor shall be ensure that gas charging to be measured as Job and if there is any leakage during the contract period then the same will be fullfilled by the contractor without any extra cost. (ii) No tools and plants, gas cylinder shall be issued by MES.
(a) Refrigerator (165 Ltrs to 310 Ltrs)
(b) Drinking Water Cooler 40/80 Ltrs
Dismantling of existing unserviceable float valve of size 15 mm and providing new one of same size, quality and characteristics suitable for water cooler.
Dismantling of existing unserviceable magnetic door lining and providing new magnetic door lining suitable for refrigerator of 165-310 Litres capacity complete all as specified and directed.
Dismantling of defective compressor sealed unit of refrigerator from existing foundation by removing suction/ discharge line and providing new approved compressor of equal capacity given below (company re-oriented) flushing complete system with nitrogen gas pressure testing for leakages, vaccumisation of complete system and gas charging with R - 134 including connection suction/ discharge line complete for 165/180 /310Ltrs capacity refrigerator complete all as specified and directed.
Dismantling of defective compressor sealed unit of water cooler from existing foundation by removing suction/ discharge line and providing new approved compressor of equal capacity given below (company re-oriented) flushing complete system with nitrogen gas pressure testing for leakages, vaccumisation of complete system and gas charging with F - 134 including connection suction/ discharge line complete for 40/60/80Ltrs capacity water cooler complete all as specified and directed.
Taking down of unserviceable condensor coil and providing new condensor coil of same size and quality for water cooler capacity upto 120 LPH complete all as specified and directed.
Taking out of defective water taps of water cooler and supply and fix new water taps chromium coated 15 mm dia push type of same quality and characteristics suitable to existing water cooler
Taking out of unserviceable PVC pipe and providing new PVC flexible pipe of 20/15 mm dia and of same quality for water circulation to air cooler all as specified and as directed.
Taking out unserviceable and supply and fix over load protector suitable for water cooler of 40/80/60/120/150 ltr cap of water cooler all as specified and as directed.
Taking out defective capacitor and supply and fix running capacitor suitable for 40/80/60/120/150 ltr capacity of water cooler all as specified and as directed.
Taking down unserviceable starting relay and supply and fix starting relay for water cooler capacity 40/80/60/120/150 ltrs all as specified and as directed.
Taking down unserviceable fan motor blade & supply and fix fan motor blade for water cooler capacity 40/80/60/120/150 ltrs all as specified and as directed.
Taking down unserviceable insulation & supply and fix thermal insulation with fiber glass 15 mm thick for water cooler of any cpacity all as specified and as directed.
Taking down unserviceable water cooler tray 80/40,80/120 ltr and supply and fix new water waste tary stainless lteel material in existing water cooler all as specified and directed.
Taking down U/s plug top and supply and fix 16 amp 3 pin plug top all as specified and as directed
Supply and provide in holes of POP (Plaster of paris) alabaster plaster (450 gms ) of very high strength, fast setting time , dries fast, snow white colour, creamy consistency, compressive strength after 1 hrs : 150kg/cm2 complete all as specified and as directed.
Advance Refrigeration Engineering Pvt. Ltd.
VIJ ASSOCIATES
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .