| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹6.3 LAccepted-AOC 21 KISHORE BHAWAN MALVIYA NAGAR AIR FORCE JODHPUR RAJ 342011 | JODHPUR | JODHPUR | RAJASTHAN | 342011 | L1 | Accepted-AOC QUOTED RATES ARE REASONABLE AND ACCEPTED | |
| 2 | L2₹7.8 L+₹1.5 L (24.6%)Rejected-Finance BINNAGURI HATKHOLA PO BINNAGURI DIST JALPAIGURI PIN 735203 W B | JALPAIGURI | WEST BENGAL | 735203 | L2 | Rejected-Finance OTHER THAN LOWEST | |
| 3 | L3₹8.8 L+₹2.5 L (39.7%)Rejected-Finance ROOM NO 281 GANESH MARUTI NAGAR CAPTAIN PRAKASH PETHE MARG BACKBAY BUS DEPOT CUFFE PARADE MUMBAI 400005 | MUMBAI | MUMBAI | MAHARASHTRA | 400005 | L3 | Rejected-Finance OTHER THAN LOWEST |
Tender Value
₹10 L
EMD Value
₹20,000
Closing Date
8 Jun 2024, 6:00 pmClosed
GE AF BIHTA
AIR FORCE STATION BIHTA - 801103
REPAIR /MAINT OF PERIMETER SECURITY LIGHTS INCLUDING REPLACEMENTS OF UNSV JUNCTION BOXES LT UG CABLE, JOINING KITS TIME SWITCH AND PAINTING OF POLES, UNSV FLAME PROOF LIGHTS AT LOGISTICS, MT SEC AND ARMOURY SEC AT AFS BIHTA
2024_MES_653724_1
8410/BHT/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
BIHTA
Class E and above and category b(i)
6 documents required · 6 mandatory
₹500
GE AF BIHTA
₹20,000
Yes
23 Sept 2024
13 May 2024
15 Jun 2024
13 May 2024
8 Jun 2024
27 May 2024
14 May 2024 - 20 May 2024
Amount
Excavation in trenches n.exc 1.5 mtr wide and n.exc 1.5 mtr deep in loose / soft soil and getting out for under ground cable / erection of poles, stays etc, complete all as specified and as directed.
Returning, filling in soil including spreading, levelling, watering and well ramming in layers n.exc 25 cm thick, complete all as specified and directed.
Removing of excavated soil n.exc 50 mtr away and depositing where directed at a level n.exc 1.5 mtr above the starting point, complete all as specified and directed.
M&L for laying of bricks subclass ‘B’ old size laid flat perpendicular to the direction of cable for protection of cable, complete all as specified and directed.
M&L for sand cushioning for cable with river washed sand and punning to provide required cover as per SSR Part –I, complete all as specified and directed.
M&L for PCC (1:2:4) type B1 using 20 mm graded stone aggregate for coping of poles, panel board etc, complete all as specified and as directed.
Disconnecting & taking out defective under ground cable from trenches, pole, pipe, floor, wall etc., locating the fault, rectify the defect and relaying the XLPE cable under ground PVC insulated and overall sheathed aluminum conductor heavy duty 1100 volts connecting and testing including relaying of old bricks for any size complete as directed by Engineer-in-Charge (Excavation,earth work, brick protection sand cushioning and GI pipe etc. shall be measured & paid for separately)
Supply & laying, connecting and testing XLPE cable underground PVC insulated and over all sheathed with aluminium conductor heavy duty 1100 volts grade laid in trenches, floors, walls, poles, ducts passing through pipe for road crossing etc. complete all as directed by Engr-in-Charge including taking out old defective/unsv cable of following sizes.
25 Sqmm 3 ½ core
35 Sqmm 3 ½ core
16 Sqmm 4 core
Supplying, laying connecting & testing in replacement P.V.C insulated sheathed, aluminium solid conductor cable of size 4 Sqmm twin core flat or circular, 1100 volts grade service connection from pole light to box with 15 mm flexible pipe connection on poles wherever required at site complete all as specified and directed.
M&L for Tube light grade galvanised with all fittings for earthing lead protection of under ground/on wall/pole size 20 mm dia complete all as specified and directed.
Material & labour for cross arms, bracing supports, clamps and back plates fabricated from structural steel sections of any size and shape including nut, bolts, washers, welding, bending, cold or hot drilling holes in bolts of any size or 25/40 mm light grade 1.2 mtr GI pipe/bracket suitable for fixing the street light also including two coats of aluminium paint over one coat of primer complete all as specified and as directed.
Supply and fixing in replacement LED street light fitting 45 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete all as specified and directed.
S & F in replacement LED bollard made up of extruded aluminium with PC diffuser with fitting on GI pipe pipe 12 watt as approved complete all as specified and directed.
Supply and fixing in replacement post top lantern LED type 20 watt 230 Volts AC outdoor type with decorative post top for 360 degree indirect light IP 65 protection with impact and corrosion resistant complete with driver and lamp complete all as specified and directed.
Supply and fixing in replacement LED flood light 120 watt 230 V AC outdoor type with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant complete with driver and lamp including all fixing arrangements on mettalic sheets complete all as specified and directed.
M & L for driver unit suitable for LED street/road way light of upto 100 watt including testing and taking down unsv street light and refxing the same complete all as specified and directed.
M & L in replacement for driver unit suitable for LED flood light of upto 60 to 200 watts including testing and taking down unsv street light and refxing the same complete all as specified and directed.
S & F in replacement thermoplastic/polycarbonate enclosure bus bar chmaber, shockproof, vermin and dust proof complete with terminals for upto 3 phase cable of size 35 sqmm 3.5 core and 01 no MCB SP 6 amps including non metallic clamps and GI nut bolts and washers of suitable size and fixed on pole/wall complete all as specified and directed.
S & F in replacement sheet metal enclosure of minimum 3 mm sheet of suitable size consisting four aluminium bus bar of 200 amps at fixed suitable gapping in enclosure outdoor type with fixing capabilty on MS angle iron on walls/ground/poles complete all as specified and directed.
Material & Labour for 1.1 KV heat shrinkable jointing kits, Indoor/outdoor end termination suitable for underground XLPE cable of following size including taking out old/unserviceable joints and testing etc. complete all as directed. Make: DENSON/Raychem/Birla 3M
16 to 35 Sqmm 3 ½ core
M&L for heat shrinkable 1.1 KV XLPE straight through joint suitable for under ground cable of following sizes complete all as specified and directed.
16 to 35 Sqmm 3 ½ core
50 to 120 Sqmm 3 ½ core
S & F for MCCB 4 pole upto 63 Amps rating 16 KA with suitable size of flat bars for connection any type of housing as required at site complete all as specified and directed.
S & F for MCCB 4 pole upto 100 Amps rating 16 KA with suitable size of flat bars for connection any type of housing as required at site complete all as specified and directed.
S & F for MCCB 4 pole upto 125 Amps rating 16 KA with suitable size of flat bars for connection any type of housing as required at site complete all as specified and directed.
Supply and fixing MCB SP rating 240V, 10KA 'C' of capacity 5 to 32 amps complete with connection complete all as specified and directed.
Supply and fixing MCB DP rating 240V, 10KA 'C' of capacity 32 to 63 amps complete with connection complete all as specified and directed.
Supply and fixing 415V 10KA 'C' curve miniature circuit breaker (MCB) of following poles and current carrying capacity in the DB complete with connection testing and commissioning of following sizes:-
TPN 16 To 32 Amp
TPN 40 To 100 Amp
M&L for earthing complete with galvanized steel earth plate electrode 600x600x6 mm thick buried directly in ground (earth not less than 2.25m deep below ground level) with top edge of the plate not less than 1.5 mtr below normal ground level connected to galvanized earth strip of size 25x4 mm by means of nuts and washer of GI or steel complete as shown in electrical plate No. 3 all earth test point including pit chamber 300x300x300 mm and cover of PCC 1:2:4 and watering pipe medium grade 20 mm and 40 mm protection pipe light grade and wire mesh funnel and welding to pole/panels of size upto 15 cm taking down existing unserviceable all as specified, including excavation and other items complete all as specified and directed.
Material & Labour for cleaning, preparing the surface of steel tubular poles LT 9.0 mtrs long including removing of rust particles and painting with two coat of aluminium paint including cross arms, bracing, supports, clamps, eye hook etc., and providing Blue & White strips alternatively 30cm each from coping to 1.5 mtr height starting with blue strip using synthetic enamel paints complete all as directed.
M/s AHMED ENGINEERING
ARTI ENTERPRISES
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .