Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹4.8 LAccepted-AOC 364 4 FIRDAUS SHABANA MARKET NEW SABZI MANDI JK COLONY ROAD KANPUR 07 | KANPUR NAGAR | UTTAR PRADESH | 208001 | L1 | Accepted-AOC Found reasonable for acceptance | |
| 2 | L2₹5.2 L+₹32,759 (6.76%)Rejected-Finance | L2 | Rejected-Finance L1 being accepted | |
| 3 | L3₹5.4 L+₹52,383 (10.8%)Rejected-Finance H NO 190 S 4 CHODANKAR RESIDENCY NEAR GANPATI TEMPLE CENTRAL HORTA AQUEM BAIXO NAVELIM SALCETE GOA 403707 | SOUTH GOA | GOA | 403707 | L3 | Rejected-Finance L1 being accepted | |
| 4 | L4₹7.1 L+₹2.3 L (47.1%)Rejected-Finance S NO 279 1 1A PLOT NO 113 KUTWAL COLONY SASTHE WASTI LOHEGAON PUNE 411 047 | PUNE | MAHARASHTRA | 411047 | L4 | Rejected-Finance L1 being accepted |
Tender Value
₹7.9 L
Closing Date
21 Jul 2021, 6:00 pmClosed
AGE (I) Mandovi
AGE (I) Mandovi Military Engineer Services INS Mandovi
As per tender documents
2021_MES_451875_1
8400/E8_AGE (I)_MANDOVI
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
Mandovi
As per tender documents
8 documents required · 8 mandatory
₹500
AGE (I) Mandovi
Exempted
4 Aug 2021
16 Jun 2021
23 Jul 2021
16 Jun 2021
21 Jul 2021
8 Jul 2021
16 Jun 2021 - 30 Jun 2021
Amount
Taking down copper/ aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc. and making good disturbed surfaces of walls, floors, etc to match existing surface complete all as specified and directed.
M & L for point wiring complete with 1.5 Sqmm 1100 volts grade single core PVC insulated unsheathed cable with multistranded copper conductor drawn through and including casing and caping of suitable size and including provn of 1.5 sqmm PVC insulated copper cable as earth continuity conductor connected to common earth dolly including suitable pressed steel terminal boxes concealed in wall with 3 mm thick hylem sheet or plastic masonite laminated sheet top cover fixed with brass screws to house switch/sockets/regulators etc for one light point or fan point controlled by one switch complete all as specified and directed.
All as per item No 2 here-in-before but for one 5 Amps switch socket combination on independent board complete all as specified and directed.
M & L for point wiring complete with 2.5 Sqmm 1100 volts grade single core PVC insulated unsheathed cable with multistranded copper conductor drawn through and including casing and caping of suitable size on surfaces and including provn of 2.5 sqmm PVC insulated copper cable as earth continuity conductor connected to common earth dolly including suitable pressed steel terminal boxes concealed in wall with 3 mm thick hylem sheet or plastic masonite laminated sheet top cover fixed with brass screws to house switch/regulators etc for one 6 pin 15 Amps socket outlet on independent/ metal plug and socket complete all as specified and directed.
S & F in repairs switch piano flush button single pole one way 5 Amps complete all as specified and directed.
S & F in repairs switch socket combination 2 in 1, 6 pin and 5 Amps, flush type complete all as specified and directed.
S & F in repairs switch socket combination 5 in 1, 6 pin and 15 Amps, flush type complete all as specified and directed.
S & F in repairs modular switch 1 way 6A, 1 module complete all as specified and directed.
S & F in repairs modular socket 6A, 2/3 pin 2 module complete all as specified and directed.
S & F in repairs modular socket 6/16A, 2/3 pin 2 module complete all as specified and directed.
S & F in repairs modular white cover plate with frame of following modules complete all as specified and directed.
2 module
3 module
6 module
8 module
S & F in repairs sheet metal enclosure for MCB's (D.B), double door, SPN 4 way with 200 Amps rated bus bar, 240 Volts, complete all as specified and directed.
S & F in repairs sheet metal enclosure for MCB's (D.B), double door, SPN 8 way with 200 Amps rated bus bar, 240 Volts, complete all as specified and directed.
S & F in repairs sheet metal enclosure for MCB's (D.B), double door, TPN 4 way, 415 Volts, complete all as specified and directed.
S & F in repairs MCCB distribution board (DB), vertical, double door, TPN 4 way, with 200 Amps rated bus bar including MCCB, 100-125 Amps, 4 pole 16 kA complete all as specified and directed.
S & F in repairs sheet metal enclosure earth plug and socket, single pole and neutral with two pin including one single pole MCB 20 Amps 240 Volts complete all as specified and directed.
S & F in repairs ceiling rose, surface bakelite, 65 x 50 mm, two to three terminals complete all as specified and directed.
M & L for earthing complete with steel earth plate electrode 60cm x 60cm x 6.3 mm thick buried directly in ground, vertically (earth pit not less than 2.25 mtr below ground level) with top edge of plate not less than 1.5 mtr below ground level connected to GI earth wire 4mm dia by means of bolts, nuts, check nuts and washers etc including 15mm dia protection pipe upto 7.5m length, connecting the earth lead to earth connection in the main distribution box with lugs and GI nuts, bolts etc as shown on electrical plate No 3 of SSR part 1 including neccessary excavation in disintergrated hard rock, filling earth upto 15 mm thick and providing earth pit, 20mm dia GI funel, PCC earth chamber, 100mm thick precast RCC cover with suitable precast RCC frame and earth test point and testing including taking out old earthing complete all as specified and directed.
S & F in repairs LED tube light fitting 1x 9 W, 2 feet baton, intergrated channel, integral sleek extruded polycarbonate LED channel with white acrylic cover including 01 no LED tube rod, cool white, prewired fixed over square block of PVC in any position and making necessary electrical connection and testing complete all as specified and directed.
S & F in repairs fan regulator, electronic step type on existing laminated sheet complete all as specified and directed.
M & L for submain wiring with two runs of 4 sqmm single core multistranded PVC insulated unsheathed cable 1100 Volts with copper conductor and one run of 4 sqmm single core PVC insulated unsheathed cable 1100 Volts with copper conductor as continuous earth wire drawn through and including 25mm/32mm wide PVC casing and caping with all accessories such as tees, elbows, junction boxes, reducers etc as required and connecting to existing main switch board/ distribution board and testing on completion including taking down old submain wiring complete all as specified and directed. Note: Two runs of 4 Sqmm cable, one run of 4 Sqmm earth wire and one run of PVC casing and caping shall be measured as unit run.
S & F call bell, ding dong, 240 volts complete all as specified and directed.
S & F bell push, flush type, 5 Amps complete all as specified and directed.
Taking down MCBs/ MCCBs of any size from Dbs complete all as specified and directed.
S & F MCB SP 6 to 32 Amps, 240 Volts, 'B' series, 6 to 10 kA breaking capacity complete all as specified and directed.
S & F MCB SPN 6 to 32 Amps, 240 Volts, 'B' series, 6 to 10 kA breaking capacity complete all as specified and directed.
S & F MCB, four pole 63 Amps, 415 Volts, 'B' series, 25kA breaking capacity complete all as specified and directed.
S & F MCCB 3 pole 125 Amps, 415 Volts for 3 phase 50 Hz, 16 kA breaking capacity complete all as specified and directed.
S & F in repairs LED downlights, 12 W, square shaped, low depth, powder coated, white finish, with drop down PC diffuser to deliver low glare ilumination with optimsed heat shrink for efficient heat dissipation and separate replaceable electronic dirver including cutting/ drilling in ceiling complete all as specified and directed. Make: Bajaj "Radiance" Cat No BPSLR 12 W WH SQ (White) or equivalent make as specified in List of Manufacturers
S & F in repairs lamp holder, PVC/ polycarbonate type with back plate suitable for batten fittings including 01 x 9 W LED lamp complete all as specified and directed.
Fixing only LED tube light fitting, batten type 1 x 18/ 20 watt, 22 V, AC of any type 4feet/ 2 feet on existing light point complete all as specified and directed. Note : LED light fitting shall be issued by the department under Schedule 'B' items and old retrieved fittings shall be deposited in the MES Store yard.
M/s.GOODWILL ELECTRICALS
Sagar Constructions
Shree Ram Enterprises
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .