Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹32.4 LAccepted-AOC | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹36.1 L+₹2.1 L (6.25%)Rejected-Finance 21 KAWARDHA COLLECTORATE ROAD KAWARDHA KABIRDHAM CHHATTISGARH 491995 | KABIRDHAM | CHHATTISGARH | 491995 | L2 | Rejected-Finance Being L2 | |
| 3 | L3₹37.0 L+₹3.0 L (8.86%)Rejected-Finance 10 2 NARAYAN BAG INDORE M P | L3 | Rejected-Finance Being L3 | |
| 4 | L4₹39.0 L+₹5.0 L (14.8%)Rejected-Finance | L4 | Rejected-Finance Being L4 | |
| 5 | L5₹40.7 L+₹6.7 L (19.9%)Rejected-Finance | L5 | Rejected-Finance Being L5 |
Tender Value
₹44.0 L
EMD Value
₹88,000
Closing Date
15 Mar 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE (MIS) MHOW
GE (MIS) MHOW
MAINTENANCE SERVICING OF SUMMER APPLIANCES AND OTHER CONNECTED WORK AND REPAIR MAINTENANCE OF LT DISTRIBUTION SYSTEM OF AMU NODE SARAGRAHI PW DIVI SW DIV AND OTHER AREAS UNDER GE MIS MHOW
2023_MES_581232_1
8542/GE (MIS)/Mhow
Open Tender
Civil Works
Item Rate
180 days
GE (MIS) MHOW
As per tender documents
8 documents required · 8 mandatory
₹500
GE (MIS) Mhow
₹88,000
1 May 2023
15 Feb 2023
17 Mar 2023
15 Feb 2023
15 Mar 2023
1 Mar 2023
Amount
M&L for removing the burnt/defective sealed compressor unit of any make from Window type air conditioner of capacity 1.5Ton by cutting of suction and discharge lines and un-screwing the foundation nuts, supply and fixing of new sealed compressor unit of Make: - Tecumseh Kirloskar, Model RNB 5522 of rotary compressor by tightening the foundation nuts with new fittings and connecting suction and discharge lines with gas welding work complete all as specified and directed.
All as per item No 1 above but Air conditioner of 2 ton capacity and sealed compressor unit Make - Tecumseh Kirloskar, Model RNB 5529 complete all as specified and directed.
M&L for removing the burnt/defective sealed compressor unit of Split type air conditioner of capacity 1.5Ton by cutting of suction and discharge lines and un-screwing the foundation nuts, supply and fixing of new sealed compressor unit Make - Kirloskar, Model AE 5522E or CR 22K 6 M /AW 1500 by tightening the foundation nuts with new fittings and connecting suction and discharge lines with gas welding work complete all as specified and directed.
All as per item No 3 above but split type Air conditioner of 2 ton capacity and sealed compressor unit Make - Tecumseh, Model AW-2000 all as specified and directed.
M&L for repairing, testing leakage in Air conditioner of 1.5 ton capacity by injecting nitrogen gas upto 300 PSI and repairing leaking spots/joints with gas welding including supply & fixing of filter pencil type copper (in replacement), cleaning & flushing out complete system with gas, making the system leak proof, vaccumising the system and supply & charging refrigerant gas F-22 (approx 1.90 Kg) complete.
All as per item No 5 above but Air conditioner of 2 ton capacity and supply and charging refrigrerant gas F-22 (approx 2.30 Kg) complete.
S&F in replacement of electric blower motor of capacity 1/7 HP SP 230V, 50Hz, 930/875/825/775 RPM for window type Air conditioner including testing etc complete all as specified and directed Make : Gulmarg/GE Motor/Crompton Greaves
S&F in replacement of electric blower motor capacity 1/8 HP SP 230V, 50Hz, 1350 RPM for 2 Ton capacity split type Air conditioner including testing etc complete Make : Gulmarg/GE Motor/Crompton Greaves complete all as specified and directed at site.
S&F in replacement of electric blower motor of capacity 1/13or 1/10 HP SP 230V, 50Hz, 1450 RPM for Split type Air conditioner including testing etc complete all as specified and directed. Make : Gulmarg/GE Motor/Crompton Greaves.
S&F in replacement of electric blower motor of capacity 1/5 HP SP 230V, 50Hz, 930 RPM for window type Air conditioner including testing etc complete all as specified and directed Make : Gulmarg/GE Motor/Crompton Greaves.
S & F in replacement of thermostat for window type AC, working on SP, 230V,AC complete all as specified Make : Indfos/ Ranutro
S & F in replacement of PCB circuit with remote control for air conditioner of any Make and capacity complete all as specified and directed. Make : Voltas/Carrier/Ranutrol/LG/Blue star
S & F in replacement of air filter for split type Air conditioner (set of three Nos) Make-Marcon or other equivalent approved by GE complete all as specified and directed.
S & F in replacement of air filter washable of Nilon mesh suitable for window type air conditioner complete all as specified and directed Make : Marcon or other equivalent as approved by GE.
S & F in replacement of starting capacitor 150 to 200 MFD, 440 volts AC ( Suitable for 2 TR split AC) complete all as specified and directed. Make : Asian/Empire
S & F in replacement of starting capacitor 100 to 120 MFD, 440 volts AC ( Suitable for 1.5 TR window type AC) complete all as specified and directed. Make : Asian/Empire
S & F in replacement of running capacitor 36/45 MFD, 440 volts AC ( Suitable for 1.5 TR window AC) complete all as specified and directed. Make : Asian /Empire
S & F in replacement of capacitor 6 MFD, 440 volts AC ( Suitable for fan motor) complete all as specified and directed. Make : Asian /Empire
S & F in replacement of relay box type model-KCH 5230004 Make : Usha/Arvind/Voltas
S & F copper filter pencil type of any make and capacity for Air conditioner complete all as specified and directed. Make : Vaishali Metal or other equivalent as approved by GE.
S&F in repair front PVC grill of window type AC of any make complete all as specified and directed at site.
S & F relay over load protector complete set suitable for AC complete all as specified and directed.
S & F in replacement of relay box type model-AC85004 /AC 85001 operating on SP 230 Volt, AC, Make : Usha/Arvind/Voltas
S&F in repair indoor unit suitable for 1.5 TR split AC Make : voltas/LG / Samsung with complete blower, remote senser with remote, conrtolling unit, swinging arrangement and air filter complete all as specified and directed.
S&F in repair outdoor unit of split AC 1.5 Ton Make : voltas/LG/ Samsung with complete sealed compressor unit capacity 1.5 Ton and blower ,condenser connecting suction and discharge lines initially filled with refrigerating gas complete all as directed.
S&F in repair indoor unit suitable for 2.0 TR split AC Make : voltas / LG / Samsung with complete blower, remote senser with remote, conrtolling unit, swinging arrangement and air filter complete all as specified and directed.
S&F in repair outdoor unit of split AC 2.0 Ton Make : voltas/LG/ Samsung with complete sealed compressor unit capacity 2.0 Ton and blower ,condenser connecting suction and discharge lines initially filled with refrigerating gas complete all as directed.
SHIFTING OF AC'S:
M&L for taking down and removing carefully split type AC complete with connected electric wires, copper tubing, insulation sleeves, outdoor unit fitting bracket etc from exiting place and fixing the same at new location including necessary transpration, find leakage in system by injecting nitrogen gas upto 300 PSi, repairing leaking spots/joints with gas welding including required copper tubing up to 2 running meter cleaning & flushing out complete system and, making the system leak proof, vaccumising the system supply & charging refrigerant gas F-22 (approx 2 Kg) in air conditioner 1.5 Ton to 2.0 ton including necessary making holes into wall for insertion of copper pipe etc and making good the disturbed surface as per existing and testing after installation complete all as directed by Engineer-in Charge
M&L for attending compliaints by checking the window type/split type AC of any capacity, Desert cooler etc of any make, size and capacity, and making the same functionable by tightening the connection, checking power point /socket point and replacement of screws, small pieces of wire, etc complete Note:- Petty stores such as insulation tape, screws, small pieces of wires, etc shall be provided by the Contractor without and extra cost.
S&F in repairs Copper tubing of following size complete:-
Supply and charging of gas R 134a in AC plant of any capacity complete all as specified and directed by Engineer-in-charge. Note:- Gas shall be supplied in sealed and tested cylinder .
M&L for repairing existing operating pannels of air conditioner (Cold store) of capacity 1.50/2 TR and making workable of incoming and outgoing connections complete all as specified and directed by Engneer-in-charge.
M&L for profile insulation of outdoor unit complete all as specified and directed.
S&F AC contactor three phase 415-660 volts 32 Amps coil voltages 230 Volt as per existing complete all as specified and directed.
S&F following parts complete all as specified and directed.
Hand shut valve of size 5/8" Make- Synergn
Pressure gauge (0-500 PSI)
Valve 3 way
Flair nut 3/4" brass
Dead plug (brass)
Union
S&F MCCB four pole 63 Amp 16 KA 415 volts complete all as specified and directed.
S&F in repairs Sheet metal enclosure with earth plug and socket single pole and neutral with single pole MCB 20 Amps 240 volts complete all as directed.
S&F in repairs Metal clad plug, 2 pole with earth terminal capacity 20 Amp fixed in existing single pole and neutral enclosure complete.
S&F in repairs Metal clad socket, 2 pole with earth terminal capacity 20 Amp, fixed in existing single pole and neutral enclosure complete.
S&F in repairs MCB SP, 240 volts, 5 to 32 Amps, 10KA breaking capacity, 'C' type including connection with suitable size aluminium /copper lugs complete all as directed
M&L for Plug top, 3 pin, 15 Amp, SP, 230V, fixed in repairs complete.
M&L for Switch socket combination piano type 5/15 Amp, 230 volts AC, fixed in repairs complete.
DESERT COOLERS :
S & F in replacement fan motor assembly of 1/7HP, 230V SP, AC complete clamps=04 Nos and water fan 18" sweep complete all as specified and directed. Make GE Motors/Auc/Crompton/ISI Mark
S & F in replacement vertical pump/Water mersed pump complete tube operated on SP 230V AC complete all as specified and directed. Make : Crompton/cool- Home/GE Motors/ISI Marked
S & F in replacement wood-wool pad complete heavy size (set of three pads) approximately 400 gm weight complete all as specified and directed.
S & F in replacement capacitor 6 MFD, 440V, complete all as specified and directed. Make - Empire/ EPCOS/ Capro/ Asian or ISI Mark
M&L for Scrapping down the complete existing paint of inside and out side of desert cooler cleaning the surface and applying two coats of synthetic enamel paint over a coat of red oxide primer with sprayer and writing SM/MES No with white black enamel paint complete all as specified and directed.
S&Fin repairs Desert cooler electric driven single phase having nominal air flow capacity of 5400 cum per hour (peak), Honycab cooling media, water storage tank capacity 95/100 liters, complete with air blower motor and water mersed pump with water level indicator complete all as specified and directed. Make: Bajaj model No. DMH 95 or other equivalent in Symphony / Blue star
WATER COOLERS :
Supply, fix & testing of blower motor for water cooler SP 230V 50 Hz AC 1/12 HP 930 RPM with fan of size 12.5" dia complete Make : GE Motor/AUE complete all as specified and directed
All as per item No 53 but 1/20 HP 1350 RPM with fan of 13" dia complete all as specified and directed.
All as per item No 53 but 1/35 HP, 1350 RPM with fan of 10" dia complete all as specified and directed
All as per item 53 above but 1/83 HP 1350 RPM and fan of 9" dia complete all as specified and directed.
S & F in replacement of starting capacitor 40 to 60 MFD, 275 volts complete all as specified and directed. Make- Sharda/Empire/Bhel.
All as per item No 57 above but of 60 to 80 MFD complete all as specified and directed.
S & F in repairs of running capacitor 10 MFD 440 volts AC complete all as specified and directed Make: EPCOS/ Capro /Asian .
All as per item No 59 above but of 15MFD complete all as specified and directed.
All as per item No 59 above but of 25/30 MFD complete all as specified and directed.
S & F in replacement of thermostat for water cooler up to 150 litres capacity. complete all as specified and directed Make : Ranutrol/Danfoss/Indfos.
S & F in replacement of push cock heavy duty brass Chromium plated 15mm bore (to match with existing defective push cock). complete all as specified and directed. Make: King or other equivalent ISI marked as approved by GE
S & F float valve 15mm bore of PVC rigid type with polythene ball complete all as directed Make : Prayag or other equivalent as approved by GE.
M&L for Scrapping down the existing water cooler painting completely of any capacity cleaning and preparing the surface with necessary putty work and painting the complete body of Water cooler including foundation frame of compressor, condenser etc with one coat of synthetic enamel paint over a coat of red oxide primer with spray painting and writing SM/MES No with white/black paint all as directed.
S & F starting Relay current type suitable for compressor model= AE 4440M, KCE 443 HAA, CAJ, 34, CAJ 2612M, AE451E, KCE 461 HAE , 513HAE complete, Make-Kirloskar/Tecumseh/ Usha / Arvind
S & F in repairs of over load protector for compressor of water cooler complete all as specified and directed.
S & F of copper filter pencil type to any make and capacity of water cooler etc complete all as specified and directed. Make : Vaishali Metal
S & F in replacement of capillary tubing having 0.050/0.055 bore complete all as specified and directed. Make : Vaishali Metal
S & F of stop cock 15mm brass heavy duty (minimum weight 360 gm) complete all as specified and directed. Make: Leader, GEM, Jaquar
S & F in replacement rubber hose pipe of 20mm size with clip for outlet tray of water cooler approx 1.5 meter long complete all as specified and directed
M&L for removing the burnt/defective sealed compressor unit of any make from water cooler of capacity 60 litres/hours by cutting of suction and discharge lines and un-screwing the foundation nuts supply and fix of new sealed compressor unit make : Kirloskar/Emmerson model : AE 444M or KCE 444 HAA/CAJ34 etc by tightening foundation nuts with new fittings and connecting suction and discharge line with gas welding work etc complete all as specified and directed by EIC.
All as per item No 72 above but water cooler of capacity 80 litres/hours and S&F compressor Make : Kirloskar/Emmerson Model : CAJ 2612M/AE451E/KCE 461 etc complete.
All as per item No 72 above but water cooler of capacity 150-150 litres/hours and S&F compressor Make : Kirloskar/Emmerson Model AHR-13/KCJ 513 complete all as specified and directed.
S & F in replacement PVC 3 core flexible heavy duty copper cable of size 2.5 Sqmm complete all as specified and directed Make : Plaza/Finolex or ISI Mark .
S & F in replacement PVC 4 core flexible heavy duty copper cable of size 2.5 Sqmm complete all as specified and directed Make : Plaza/Finolex or ISI Mark .
M & L for repairing, testing the leakage in system by charging of Nitrogen Gas up to 300 PSI and repairing of leakage spots/joints with gas welding work, cleaning and flushing the complete water cooler with gas, making the system leak proof, vacuuming the complete system, supply and charging of Freon-22 Gas approx 1.6 Kg complete for water cooler 40/60/120 litres capacity
M&L for dismantling of water cooler of any capacity and taking out complete internal assembly ie. inner tank, inlet and out let connection etc and descaling with chemical agent including cleaning and washing and reassembling with same position and making the tank leak proof by necessary brazing/welding work with gasket etc.complete all as specified and directed by EIC.
M&L for replacement of water cooler inner tank made of stainless steel as per existing with necessary gaskets complete set with drilling work fixing with nut,bolts & washer etc complete for water cooler of 80 litres capacity all as specified and directed.
All as per item No 79 but for water coolar of 150 litres capacity complete all as specified and direct ed at site.
M&L for replacement of glass wool in 40/60/80/120 litres capacity water coolers by taking out inner outer tank and reassembling in same position including testing complete all as specified and directed.
M&L for repairing of bottom base and legs of water cooler by providing suitable iron member, as per existing in pieces by necessasry welding work complete all as specified and directed.
DEEP FREEZER :
M&L for testing the leakage in system by charging Nitrogen Gas up to 300 PSI and repairing the leakage spots/joints with welding work including supply and replacement of filter pencil type copper and capillary tube of existing dia & length and making the system leakproof vacuuming the system and charging of Gas 134a approx 1.0 Kg and testing after completion all as specified and directed.
S & F in replacement of Relay current type and over load protector complete set suitable for compressor Model KCE 336 & KCE 345/2415 all as specified and directed.
S & F in replacement of thermostat Auto defrost type for Deep freezer (Refrigeration of any make & capacity) complete all as specified and direct ed at site. Make : Ranutrol/Indfos
M&L for removing burnt/defective sealed compressor unit from deep freezer of any make by cutting of suction and discharge lines and un-screwing of foundation nuts, Supply and replacing of new sealed compressor unit Make : Kirloskar Model :KCS 410 LAA/KCS 412 LAG/Tecumseh 2415 including necessary gas welding making the system leak proof, testing and tightening the foundation nuts with new grounts and connecting suction and discharge line with gas welding work etc complete.
All as per item No 87 above but of compressor Make-Tecumseh Model TSK-1350 complete all as specified and directed.
S & F relay current type and over load protector complete set suitable for compressor model No KCS 410 LAA or KCS 412 LAG fixed in repairs complete all as specified and directed.
S & F in replacement of drier filter complete set suitable for deep freezer 215 / 386 litres complete all as specified and directed.
S & F blower motor for Deep frizer SP 230V 20 watts complete with fan including testing complete all as specified and directed
REFRIGERATOR :
S&F in repairs relay current type and overload protector complete suitable for compressor model KCE336, KCE345 complete all as specified and directed Make : Ranutrol/ Voltas /LG
S&F in rpeair Thermostat auto defrost type for refrigerators any make & capacity 165/310 litres Rerfrigerator complete all as specified and directed. Make : Danfos/Ind foss/Ranutrol
S&F Vegitable tray as per existing and suitable for refrigerator of 300 litres capacity Make Godrej, Voltas or whirlpool , LG.
S&F in repairs evaporator suitable for Voltas/Godrej refrigerators capacity fixed in repairs 286/300 litres complete all as specified and directed.
M&L for removing burnt/defective sealed compressor unit of any make from any type/Capacity (165/286/300/310 Ltr) of refrigerator by cutting of suction and discharge lines and un-screwing of foundation nuts and supply & fixing new sealed compressor unit Make Tecumesh, Godrej, Voltas or whirlpool , LG, including necessary gas welding, making the system leak proof, including Repair to leakage system by charging of nitrogen gas upto 300PSI, in the refrigeration system, testing and tracing the leakage in system, arresting the leakage with gas welding etc and making the complete system leak proof, vaccumising the system and making refrigerator for smooth functioning and charging of refrigerent gas 134a including necessary testing complete all as specified and directed
Supply and charging / topping up of gas Freon- 22 complete all as specified and directed Note:- Gas shall be supplied in sealed and tested cylinder of capacity 10 Kg each.
M&L for checking of AC supply electrical/electronics circuitary of water purification system, finding fault and rectification the same with repair of step down transformer 230 volt to 12/24 volts, and replacement of resistance , small pieces of wires etc complete all as directed .
S&F in repair of water purifier installed in various building of Infantry school and MH area including replacement of candle 10'' filter set and cartrige, carbon filter and pri filter complete all as directed. Make- Aqua guard/ Beetek
S&F in repair of water purifier and replacement of solonoid valve, PF nozzle, EVA tube, boul set etc installed in various building of Infantry school and MH area and made functional complete all as directed. Make- Aqua guard/ Beetek
M&L for checking the unserviceable plant (such as water cooler, refrigerator, Deep frizer etc) of any make, size and capacity, making the same serviceable functionable by tightening the connection, checking power point including, replacement of screws, small pieces of wire, etc complete Note:- Petty stores such as insulation tape, screws, small pieces of wires, etc shall be provided by the Contractor without any extra cost.
M&L for removing the burnt/defective sealed compressor unit of Tower type make from any type of air conditioner capacity 4.0 Ton of 3 phase by cutting of suction and discharge lines and un-screwing the foundation nuts, supply and fix new sealed compressor unit make - Daikin Model JT160BCBY1L, Kirloskar or other equivalent as approved by GE by tightening the foundation nuts with new fittings and connecting suction and discharge lines with gas welding work complete all as directed.
S & F in replacement of PCB circuit with remote control for Tower AC air conditioner of capacity 4.0 Ton of any Make complete all as specified and directed . Make : Voltas/Lloyd/Blue star
M&L for repairing leakage in system of Air conditioner of 4.0 ton capacity by injecting nitrogen gas upto 300 PSi, repairing leaking spots/joints with gas welding including supply & fix filter pencil type copper cleaning & flushing out complete system with gas, making the system leak proof, vaccumising the system and supply & charging refrigerant gas F-22 (approx 7.6 Kg) complete all as specified and directed.
S&F in replacement of electric Condentioner motor ofcapacity 6 P SP 230V, 50Hz, 120 W for 4 Ton capacity Tower type Air conditioner of out door unit including testing complete complete all as specified and directed. Make : Gulmarg/GE Motor/Crompton Greaves
S&F in replacement of electric Blower motor of capacity of 8 P SP 230V, 50Hz, 120 W for 4 Ton capacity Tower type Air conditioner of Indoor unit including testing complete all as specified and directed. Make : Gulmarg/GE Motor/Crompton Greaves.
S&F in replacement of Fan Blade for condentioner motor of Out door unit dia 560X169 capacity for 4 Ton capacity Tower type Air conditioner including testing complete all as specified and directed Make : Gulmarg/GE Motor/Crompton Greaves complete .
S&F in replacement of Capacitor 10 MFD for Fan of condentioner motor of Out door unit dia 560X169 capacity for 4 Ton capacity Tower type Air conditioner including testing complete all as specified and directed Make : Renutral/ Epcos
VOLTAGE STABLIZER :
Taking out of deffective / burnt stablizer from various locations under GE (Maint) Infantry school Mhow of various capacity from 1 KVA to 5 KVA single phase and repair /replacement of the following defective parts and testing complete all as specified and directed. by Engineer-in-charge.
Terminal strip
Push button switch
Rocker switch
Circuit card from 3 to 5 KVA
Circuit card from 1 to 2 KVA
Relay 24 Volts 250 Ohms for 3 to 5 KVA
Volt meter 0-300 volts size as per sample
Indicator lamp (red/green)
Booster /stabliser transformer 230 volts AC for 3 to 5 KVA
Booster / stabliser transformer 230 volts AC for 1 to 2 KVA
REPAIR/MAINTENANCE OF LT DISTRIBUTION SYSTEM:
Excavation in trenches in any type of soil not exceeding 1.5m wide and not exceeding 1.5m in depth for foundation, etc or not exceeding 10 Sqm on plan for laying of cable, pipe, shafts, cesspits, manholes, pier holes, etc complete all as specified.
Returning, filling in excavated approved soil, including spreading, leveling, watering and well ramming in layers not exceeding 25cm each complete.
Removing excavated soil to a distance not exceeding 50m and depositing where directed at a level not exceeding 1.5m above the starting point complete.
M&L for Sand cushioning with fine dry unwashed sand in trenches for protection of cables complete. NOTE : Thickness shall be measured after panning down.
M&L for old size sub class ‘B’ bricks, laid in trenches as cable covers .
Supply and fixing Steel tubes, galvanised, light grade, ISI marked 40mm bore for protection of cable under floor, road and on wall complete.
S&F in repairs AC three phase keypad based, BIS marked pre-payment static Energy meter ,current rating 10-60 /20-100 A , 240 V (L-N) with bluetooth compatibility and mobile application. Make:- SECURE/L&T/HPL Note :- Old electric meter shall be handed over to AGE E/M store Yard.
S&F in repairs AC single phase keypad based,BIS marked pre-payment static Energy meter ,current rating 10-60 /20-100 A , 240 V (L-N) With bluetooth compatibility and mobile application Make:- SECURE/L&T/HPL Note :- Old electric meter shall be handed over to AGE E/M store Yard.
S&F in repairs AC Single phase two wire static watt hour meter (Electronic KWH Energy meter) of rating 5-30 A, class 1.0,240 V,50 Hz,LCD Display. Make:- HPL Cat part No SPPB1310000000OC00 or other equivalent in SECURE / L&T Note :- Old electric meter shall be handed over to AGE E/M store Yard.
S & F in replacement XLPE insulated and PVC armoured heavy duty electric cables with aluminum conductor, 1100 volt grade of size 2 core 10 sqmm in trenches / through pipes / ducts or on poles / walls jointing to O/H conductor, LT panels, main switch with suitable size aluminum lugs and testing complete all as specified and directed . Note : (a) Excavation shall be measured and paid seperately under respective items of Sch 'A' (b) All required lugs of suitable sizes according to size of cable shall deem to be included in the rate quoted.
All as per item No 122 above but for 16 Sqmm 4 core.
All as per item No 122 above but for 50 Sqmm 3.5 core.
All as per item No 122 above but for 95 Sqmm 3.5 core.
All as per item No 122 above but for 120 Sqmm 3.5 core.
S&F in repair MCCB 3 Pole, 415 V, fixed type, 25 to 100 Amps with breaking capacity 16 KA Make:- ABB/L&T/Schneider
S&F in repair MCCB 3 Pole, 415 V, fixed type, 125 Amps with breaking capacity 16 KA Make:- ABB/L&T/Schneider
S&F in repair MCCB 3 pole, 415 volts, adjustable type 160 Amps with breaking capacity 36 KA Make:- ABB/L&T/Schneider
S&F in repair MCCB 3 pole, 415 volts, adjustable type 200 Amps with breaking capacity 36 KA Make:- ABB/L&T/Schneider
S&F in repair MCCB 3 pole, 415 volts, adjustable type 250 Amps with breaking capacity 36 KA Make:- ABB/L&T/Schneider
S&F in repair MCCB 3 pole, 415 volts, adjustable type 350 Amps with breaking capacity 36 KA Make:- ABB/L&T/Schneider
S&F in repair MCCB 3 pole, 415 volts, adjustable type 400 Amps with breaking capacity 36 KA Make:- ABB/L&T/Schneider
S&F in repairs MCB TPN, 415V, 40 Amps, 'B' series Make:- ABB/L&T/Schneider
S&F in repairs MCB SPN, 240V, 40 Amps 'B' series Make:- ABB/L&T/Schneider
S&F in repairs three phase contactor 5kW of load capacity 20-25 Amps, incoming-Outgoing MCB (03 Nos each) rating 20-25 Amps complete all as specified and as directed . Make:- ABB/L&T/Schneider
M&L for Re-stretching tightening and fixing in position existing OH ACSR conductor LT line 3 phase with neutral and earth wire 440 V, 5/6 wire by loosing including taking down the existing binding wire from the insulator of any size and bring ACSR conductor to required sag including provision of new binding wire and tightening of cross arm on each pole including trimming of tree branches contacted with OH conductor complete all as specified and directed by Engineer-in-Charge. Note :- 1. Each line of wire shall measured and paid . 2. Quoted rate shall deemed to be include for cutting and trimming of tree branches contacted with ACSR conductor
M&L for trimming / pruning of tree branches touching to the LT over head line or near to the LT over head line as per direction of AGE E/M /JE in charge complete including removing the tree branches from site complete all as specified and directed . NOTE - (a) written shut down shall be obtained from concerned JE / AGE E/M before carrying out the trimming work in hand by contractor (b) span from one pole to next pole shall be 30m to 50m and shall be considered as a Each job (c) T & P such as ladder , rope, cutter , axes and other related material shall be provided by the contractor.
S&F in repair LED street light fitting 60 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete.
S&F in repair LED street light fitting 70 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete.
S&F in repair Energy saving, environmental friendly, long life, exclusive innovative die-cast aluminium IP 66 flood light(Area light) of 50 Watt, suitable for highlighting architectural façade and general purpose lighting. Make :-BAJAJ Cat Part No : BJLF 50W LED I or other equivalent in Havells /CG.
M&L for repairing street / security light of any type and flood lights / post top lanterns or any other external lights in its position fixed pole / building structure or by taking down to ground, if required and testing all the components / parts, wiring etc, identifying and replacing the defective components like choke (ballast), electronic driver (in case of LED Lights), ignitor, capacitor, lamp, lamp holder, connector, connection wires/ cable, MCB etc and refixing the fitting in its original position (if taken down), including repairing of street light control timer & junction box and makethe light fitting functionable in all respects complete all as directed by Engineer-in-charge.
Note:- (a) Spares such as choke (ballast), electronic driver, Ignitor, capacitor, lamp, lamp holder, connector, connection wire, MCB, timer spares etc shall be measured & paid separately under respective items. (b) The contractors / Representative shall report to concerned JE E/M at 09.00 hours daily to collect the details of complaints of defective street light fittings and shall submit the completion report of complaints of fitting on the same day before 17.30 hours to JE E/M. (c) The contractor shall rectify the defects / repair and make the street light functional within 24 hours from the time of handing over of complaint over by the concerned JE E/M. An amount of Rs 150/ day per complaint shall be recovered from contractor if street light shall not be repaired and functionable within 24 hours.
(d) Contractor shall arrange requisite and sufficient no of labours,ttransport and vehicle mounted hydraulic ladder etc at his own arrangement. (e) The contracor shall maintain proper record of repair/maint of light fittings in a binded register duly showing the details of spares replaced on each and every street light and get it authenticated from concerned JE E/M on daily basis. The contractor shall show the record register to Engineer-in-charge for inspection every Monday or as and when asked for. (f) The contractor shall be fully responsible for the safety of his men engaged for executing this work and provide all requisite safety equipment and clothings etc to Electrician & Helper. Contractor shall be fully responsible for any kind of mishappening /accident / injury etc if any to his employed labours.
(g) The contractor shall maintain sufficient stock of spares/material as required for repair/maint of street lights. (h) Contractor quoted rate shall be inclusive for screws, insulating tapes, internal wiring wire, gaskets and other minor items as required for repairing and making the street light fittings/security light fittings in serviceable condition.
Supply only following items/spares.
Supply only LED driver of capacity 60/70 watts rating 240 Volt, 50 Hz complete all as specified Make:- Philips, Bajaj, Havells
Supply only LED driver of capacity 30/36/45 watts rating 240 Volt, 50 Hz complete all as specified Make:- Philips, Bajaj, Havells
S&F in repair single core pvc insulated and sheathed cable with multistranded aluminium condutor of size 2.5 sqmm and drawing in to existing GI pipe bracket and connect to street light fittings
S&F in repair Digital Timer switch for 1x 24 Hrs for controlling street light timimng with 150 hrs back up fixed in repairs.
S&F 1100 volts grade heavy duty cable PVC insulated aluminium conductor, served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1 metre apart including 4mm suspension wire, one twin core cable flat or circular of size 10 sqmm.
M&L for attending external electric complaints by opening / disconnecting the electrical connection of defective / burnt out underground LT cable of any size & any core from LT O/H line / LT UG cable etc. and taking out the required length of cable from existing loop and remove cut the defective cable and replace the same with new cable as per existing size including providing necessary thimbles / connectors at cable end and reconnecting the cable in previous location with existing main switch / DB / Junction box / LT panel / OH line etc. and restore electric supply by making necessary electic connection and functionable in all repspects including testing on completion all as specified and directed by Engineer-in-charge.
All as per item No 147 above above but from switch gears /main switch board of any type and size including suitable size of aluminium cable lugs as required at site
Supply only DO fuse elements of following capacity
5 to 25 Amps suitable for 11 KV System
30 Amps suitable for 11 KV System
5 to 25 Amps suitable for 33 KV System
30 Amps suitable for 33 KV System
Supply ,fabrication, install and testing LT Panel out door type factory made CPRI Approved, water and vermin proof protection of size 750 mm x 750 mm x 500 mm (over all dimension) made out of 3.00 mm thick CRCA sheet dully supported with mild steel angle iron of size 50 x 50 x 6 mm vertical frame and legs with mild steel flat iron 25 x 5 mm in horizontal sides of the frame with front and back side openable ,single hinged door shutter with locking arrangement and powder coatedpainting finish at both internal and external steel surfaces including necessary preparation of steel surfaces including providing PCC (1:3:6) type C2 foundation of suitable size and connections of all outgoing / incomming cable inclusive of necessary excavation and earthwork as required including the following fitment accessories and removing old panel board of any description complete all as specified and as directed. . NOTE:- Quoted rate shall be inclusive for earthwork excavation,returning filling,removing soil , PCC work etc complete as required at site
Aluminium strip busbar of 350 Amps rated capaacity wrapped with PVC sleeves with maintained the colour code and provision of making holes with Copper nuts, bolts & washers for cable connections including hydrograpic insulators with nuts & bolts at both ends = 04 Nos
4 pole MCCB 200 Amps with rotary handle, adjustable thermal magnetic release type 415 Volts, Ics = 100% Icu, breaking capacity 35 KA including all fixing accessories with both ends spreader links - 01 No.Make:- L&T/ABB/Schneider
LED Neon indicator lamp (RYB) with holder and fuse holder 230/250 volts, AC -01 set (set of three) Make :- Legrand/L&T/Schneider.
4 Pole MCB 63 Amps with rotary handle, adjustable thermal magnetic release type, 4 poles, 415 Volts, Ics = 100% Icu, 16 KA breaking capacity including all fixing accessories with both ends spreader links -05 Nos Make:- L&T/ABB/Schneider
Enamelled iron danger notice plate of 1.60 mm thick mild steel sheet of size 200 mm x 150 mm , white with letters , figures and conventional skull and bones in signal red and fixed with nuts and bolts on door / shutter of JB .
sanjay traders
S.S. Engineers
ENVIRO TECH SERVICES
Ms Kailash Chandra Babulal
Vinayak Trading House
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .