Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹26.8 LAccepted-AOC ROOM NO A 46 GALI NO 11 GANESH MURTHY NAGAR PART NO 3 CAPT PRAKASH PETHE MARG CUFFE PARADE COLABA MUMBAI 400005 | MUMBAI | MUMBAI | MAHARASHTRA | 400005 | ₹26.8 L Quoted ₹28.0 L | L1 | Accepted-AOC BEING LOWEST |
| 2 | L2₹31.5 LRejected-Finance | ₹31.5 L | L2 | Rejected-Finance BEING OTHER THAN LOWEST |
| 3 | L3₹33.9 LRejected-Finance 47 HUSENI LAKDA BAZAAR 242 BELLAIS ROAD MUMBAI 08 | MUMBAI | MUMBAI | MAHARASHTRA | 400008 | ₹33.9 L | L3 | Rejected-Finance BEING OTHER THAN LOWEST |
| 4 | L4₹34.2 LRejected-Finance B 134 GANESH MURTHI NAGAR PART III COLABA MUMBAI 400 005 | MUMBAI | MAHARASHTRA | 400005 | ₹34.2 L | L4 | Rejected-Finance BEING OTHER THAN LOWEST |
| 5 | L5₹37.0 LRejected-Finance SHOP NO 10 BMC SHOPPING CENTRE MITHA NAGAR GOREGAON WEST MUMBAI 400 104 | MUMBAI | MUMBAI SUBURBAN | MAHARASHTRA | 400104 | ₹37.0 L | L5 | Rejected-Finance BEING OTHER THAN LOWEST |
| Sl No | Description | Qty | Unit | SHRI SAI ENTERPRISES L4 | P LAXMI AND CO. L6 | Unity Enterprises L3 | jkconstruction L1 | Shree Ayyappa Engineering L5 | Accura Associates L2 | GANGAJAL L7 |
|---|---|---|---|---|---|---|---|---|---|---|
| 1.00 | Supply & fix in replacement of unserviceable PVC loft tank (HDPE) of capacity 275 ltrs with complete fitting including 03 Nos adopter with washer for inlet/outlet over flow as per manufactureres instructions complete all as specified and directed by Engineer-in-Charge | 150 | Each | 1,400 ₹2,10,000 Lowest | 1,800 ₹2,70,000 | 1,700 ₹2,55,000 | 1,800 ₹2,70,000 | 1,500 ₹2,25,000 | 1,700 ₹2,55,000 | 1,647 ₹2,47,050 |
| 2.00 | Supply and fixing replacement PVC profile suitable for 275 ltr loft tank including fixng of aluminium channel around the profile complete all as specified and directed by Engg-In- Charge. | 100 | Each | 300 ₹30,000 | 300 ₹30,000 | 300 ₹30,000 | 200 ₹20,000 Lowest | 600 ₹60,000 | 520 ₹52,000 | 310 ₹31,000 |
| 3.00 | M& L for Cleaning of loft tanks of capacity 170 to 275 ltrs in existing position by mechanised pressure, cleaning using PVC tank cleaning solution and draining out the water by wet vaccum pump, rinsing with clean drinking water complete all as specified.
Note : Any damage to pipe and PVC tank during cleaning shall be made good by the contractor at his own cost. | 200 | Each | 100 ₹20,000 | 50 ₹10,000 Lowest | 150 ₹30,000 | 60 ₹12,000 | 150 ₹30,000 | 77 ₹15,400 | 285 ₹57,000 |
| 4.00Cleaning of underground sump of any capacity cleaning the floors, wall and ceiling portion of sump etc by Mechnical high pressure spray and steel wire brush to remove Algae/dirt/foreign dirt completely and soaking out the water/dirt with a high pressure wet vaccum pump and removing spoils out side of MD land land distance exc 5 KMs & n.exc 10 KMs and applying spray of approved chemical etc. complete all as specified and as directed by Engineer-in-charge . Note :- 1. Rates deemed to be included for pumping out water left below foot valve. 2. Rate include the painting of two coats of enamal paint with visible colour on all sides and writing capacity of sump about date of cleaning and due date for cleaning complete all as specified. | ||||||||||
| 4.01 | Sump capacity of approximately 9,20,000 liters | 2 | Each | 14,000 ₹28,000 | 20,000 ₹40,000 | 25,000 ₹50,000 | 12,000 ₹24,000 Lowest | 16,000 ₹32,000 | 25,000 ₹50,000 | 37,000 ₹74,000 |
| 4.02 | Sump capacity of approximately 16,00,000 liters | 1 | Each | 18,000 ₹18,000 | 25,000 ₹25,000 | 30,000 ₹30,000 | 12,200 ₹12,200 Lowest | 20,000 ₹20,000 | 35,000 ₹35,000 | 55,555 ₹55,555 |
| 4.03 | Sump capacity of approximately 14,00,000 liters | 2 | Each | 16,000 ₹32,000 | 22,000 ₹44,000 | 28,000 ₹56,000 | 10,000 ₹20,000 Lowest | 15,000 ₹30,000 | 30,000 ₹60,000 | 47,000 ₹94,000 |
| 4.04 | Sump capacity of approximately 4,50,000 Liters | 1 | Each | 11,000 ₹11,000 | 9,000 ₹9,000 | 10,000 ₹10,000 | 7,000 ₹7,000 Lowest | 12,000 ₹12,000 | 8,000 ₹8,000 | 27,000 ₹27,000 |
| 4.05 | Sump capacity of approximately 3,20,000 Liters | 2 | Each | 9,000 ₹18,000 | 9,000 ₹18,000 | 8,500 ₹17,000 | 5,000 ₹10,000 Lowest | 12,000 ₹24,000 | 6,500 ₹13,000 | 17,865 ₹35,730 |
| 4.06 | Sump capacity of approximately 2,20,000 Liters | 2 | Each | 8,000 ₹16,000 | 8,000 ₹16,000 | 7,500 ₹15,000 | 5,000 ₹10,000 Lowest | 9,000 ₹18,000 | 5,000 ₹10,000 Lowest | 14,000 ₹28,000 |
Tender Value
₹49.0 L
EMD Value
₹98,000
Closing Date
7 Mar 2026, 6:00 pmClosed
GE (NW) NAVY NAGAR, COLABA, MUMBAI
GE (NW) NAVY NAGAR, COLABA, MUMBAI, DR HOMI BHABHA ROAD COLABA, MUMBAI
REPAIR/MAINTENANCE OF UNSERVICEABLE SMC PANEL TANK, PVC WATER STORAGE TANK OF VARIOUS CAPACITY, LOFT TANKS, CLEANING OF TANKS AND ALLIED WORKS AT OLD AND NEW NAVY NAGAR AREA UNDER GE (NW) NAVY NAGAR, COLABA, MUMBAI
2026_MES_752674_1
8628/E8
Open Tender
Civil Works - Water Works
Item Rate
270 days
GE (NW) NAVY NAGAR, COLABA
Class D and Category a(ii)
8 documents required · 8 mandatory
₹500
GE (NW) NAVY NAGAR
₹98,000
28 Mar 2026
13 Feb 2026
9 Mar 2026
13 Feb 2026
7 Mar 2026
28 Feb 2026
13 Feb 2026 - 7 Mar 2026
Supply & fix in replacement of unserviceable PVC loft tank (HDPE) of capacity 275 ltrs with complete fitting including 03 Nos adopter with washer for inlet/outlet over flow as per manufactureres instructions complete all as specified and directed by Engineer-in-Charge
Supply and fixing replacement PVC profile suitable for 275 ltr loft tank including fixng of aluminium channel around the profile complete all as specified and directed by Engg-In- Charge.
M& L for Cleaning of loft tanks of capacity 170 to 275 ltrs in existing position by mechanised pressure, cleaning using PVC tank cleaning solution and draining out the water by wet vaccum pump, rinsing with clean drinking water complete all as specified. Note : Any damage to pipe and PVC tank during cleaning shall be made good by the contractor at his own cost.
Cleaning of underground sump of any capacity cleaning the floors, wall and ceiling portion of sump etc by Mechnical high pressure spray and steel wire brush to remove Algae/dirt/foreign dirt completely and soaking out the water/dirt with a high pressure wet vaccum pump and removing spoils out side of MD land land distance exc 5 KMs & n.exc 10 KMs and applying spray of approved chemical etc. complete all as specified and as directed by Engineer-in-charge . Note :- 1. Rates deemed to be included for pumping out water left below foot valve. 2. Rate include the painting of two coats of enamal paint with visible colour on all sides and writing capacity of sump about date of cleaning and due date for cleaning complete all as specified.
Sump capacity of approximately 9,20,000 liters
Sump capacity of approximately 16,00,000 liters
Sump capacity of approximately 14,00,000 liters
Sump capacity of approximately 4,50,000 Liters
Sump capacity of approximately 3,20,000 Liters
Sump capacity of approximately 2,20,000 Liters
Sump capacity of approximately 2,40,000 Liters
Sump capacity of approximately 1,40,000 Liters
Cleaning of PVC and RCC water storage tank in low and high rising buildings(G+14) by mechanical high pressure spray and remove all foreign matter completly and soaking out the water/dirt with a high pressure wet vaccum pump and removing spoils out side of MD land and complete all as specified and as directed by Engineer-in-charge . Note: Rate include the painting of two coats of enamal paint with visible colour about date of cleaning and due date for cleaning complete all as specified.
OH Tank of capacity 2000 Litres
OH Tank of capacity 5000 Litres
OH Tank of capacity 3000 Litres
OH Tank of capacity 10000 Litres
OH Tank of capacity 15000 Litres
S&F in replacement FRP lid cover for PVC water storage tank complete accessory for closing and locking arrangement suitable for various capacitys as approved by BMC
For capacity of 5000 litres
For capacity of 3000 litres
Cleaning the vegetation including grass, bushes small trees and all vegetation growth complete including uprooting of bushes and small trees around the installation/sump/OH reservoir, valve chamber etc. filling the rough holes with earth and levelling the surfaces by removing all debris to a distance n.exc.50m complete all as specified and directed.
Supply/Fixing in repair/replacement of internal steel water tubing with CPVC pipes SDR 11 & PlainCPVC SDR 11 fittings in wall and shafts including necessary saddling and and work to be done in high rise building up to 15 th floor short piece/length, including breaking the existing brick wall for replacement of corroded GI pipe in/on wall and making good the disturbed surfaces complete all as specified and directed by Engineer-in-charge of the following size :-
20 mm Nominal outside dia
25 mm Nominal outside dia
Supply & Fixing in repairs Compound girders and stanchions, lattice girders, aerial masts, staging for water tanks, ladders and the like including caps, bases, splices etc. built up from two or more beam or channel sections or angles with plates, including all lattice bars, stiffeners, gusset plates, etc with Fe 410 -W (Gde- E- 250) including making paint with two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed. Note:Contractor should survey each quarter in old and new navy nagar and highly rusted angle should be change accordingly.
Material and labour for bacteriological and chemical analysis of water sample at govt approved lab (Iso 9001:2008)including collecting sample from pumphouse using labed owned sample jar and testing every month all directed and specfied by Engineer-in-charge
Checking of over head tanks of any capacity , making arrangement of mosquito proofing of the tank from overflow side with new GI tank nipples, socket, barrel nipple , elbow, MS wire net, locking the existing tank cover to avoid entry of lizards, mosquitos inside the tank, tightening of all inlet and out let connections to make the tank no leaking of water complete including painting with white colour paint on base coat and writing the letters of black colour of the following details all as specified and directed :- (a) Date of cleaning (b) Date of Next due (c) Tank capacity
Supply, Installation Testing & Commissioning in repair of Motor Actuated Butterfly Valve (With manual operating wheel) consisiting of Quarter turn single phase Actuator and Wafer type butterfly valve of size 300 mm dia with appropriate bracket/mounting arrangement including two nos. limit switches for open and closed condition and splash proof enclosure. Specifications & Features Input Voltage: 230 V, A.C. , Designed line pressure: 16 kg/sq cm. Operating Angle: 90 degrees, Disc Material: CI with nylon coating Limit Switches : 02 Nos.For open and close status Mounting : Extended type with universal joint for installation 18-24 inches above the pipe level with angle mounting including raising of existing chamber as required at site. Note :-1. Rates also including of cutting, welding and any modifications in existing line with suitable DI/CI fittings with joints and its fixing are completely included in the item rate and no extra cost will be claimed by the contractor. Make :- Emtork/Hasel Hofener/Ritetork/Siemens/Honeywell Note :-2 Contractor's shall visit the site before quoting the rate of the item.
All as per item No. 12 above but capacity of motor actuated butterfly valve of size 200 mm dia complete all as specified and directed
All as per item No. 12 above but capacity of motor actuated butterfly valve of size 100 mm dia complete all as specified and directed
All as per item No. 12 above but capacity of motor actuated butterfly valve of size 80 mm dia complete all as specified and directed
All as per item No. 12 above but capacity of motor actuated butterfly valve of size 50 mm dia complete all as specified and directed
Supply & fixing in repair on wall/ laying in trench 4C x 1.5 sq mm PVC sheathed and PVC insulated, armoured, FRLS, copper cable. (Make: POLYCAB/FINOLEX/Havells)
Supply & fixing in repiar wall/ laying in trench 6Cx 1.5 sq mm PVC sheathed and PVC insulated, armoured, FRLS, copper cable. (Make: POLYCAB/FINOLEX/Havells)
S&F in replacement PVC water storage Tank with cover 3 layer, ISI marked, pure anti microbail round type and making connections including replacement of new GI fittings i.e. tank nipple, washers, float valves and Gate valves and Pipes for connecting the existing Inlet/delivery lines, testing complete all as specified and directed for the following capacity :- Note :- Gate valves and GI pipe only shall be paid under relevant item of Schedule 'A' remaining items shall be deemed to be included in the item rate.
5000 Ltr capacity
3000 Ltr capacity
2000 Ltr capacity
1000 Ltr Capacity
Supply and fixing in replacement , Installation, Testing and Commissioning of Float type Point Level Sensor with the following specifications; Type: Magnetic Magnet: Ring type Switch: Reed Switch (Epoxy sealed) Connecting Cable: Teflon
Supply and fix in repairs in existing line, gun metal gate valve with iron wheel head screwed both ends for iron pipe including fittings i.e. union, socket etc complete all as specified of following sizes :-
40 mm bore
50 mm bore
80 mm bore
25 mm bore
Supply and fix in repair brass float valve (ISI marked) high pressure with polythelene float (flat) and fly nut complete screwed for GI pipe 15mm bore including necessary GI fittings such as elbow, reducer, nipple etc.
All as per item No 22.00 above but for GI pipe 25 mm bore
All as per item No 22.00 above but for GI pipe 40 mm bore
To make the system fully functional. all panels shall be consisting of the following :- (a) Rack mountable Web Smart Switch with 28 ports and POE for CPE hardware and following specifications:- (i) Number of Ports 24 10/100Base-TX Ethernet ports 2, 10/100/ 1000BASE-T 2 Combo 10/100/1000BASE-T/SFP. (ii) Port StandardSupply and fixing unctions • IEEE 802.3 10BASE-T Ethernet (twisted-pair copper) • IEEE 802.3ab 1000BASE-T Gigabit Ethernet (twisted-pair copper) • IEEE 802.3x Flow Control • IEEE 802.3u 100BASE-TX Fast Ethernet (twisted-pair copper) • IEEE 802.3z Gigabit Ethernet (fiber) ANSI/IEEE 802.3 • IEEE 802.3z Gigabit Ethernet (fiber) ANSI/IEEE 802.3 Switching Capacity • 12.8 Gbps Make : Siemens, Dlink, Ubiquiti, Cisco
(b) Hot pluggable 1310 nm multimode/Single mode SFP (mini-GBIC) transceiver, supporting full duplex, Gigabit speeds on multimode/Single mode fiber for distances of up to 550m/550m/10km on 62.5µm/50µm/ 9µm respectively in a metal housing to reduce EMI and to increase durability Make : Dlink, Ubiquiti, Cisco, Siemens, HP (c) Rack Mountable LIU with the following specifications:- (i) Rack Mountable 12 Port Unloaded LIU (ii) Aluminium Base Material (iii) Slim 1 U mounting height (iv) Metal Shelf Aluminium 1.2 mm thick (v) Splice tray Aluminium 0.6mm (vi) Winding Panel – Plastic (vii) Cable Plug – Rubber for minimum 2 cable entries (viii) Adaptor Panel Aluminium 1.5 mm thick (ix) 2 fiber spools built in for 900 um tight buffered fibre storing (x) Capable of storing upto 3 mts of 900 um tight buffered fibre per adaptor
(d) SC-LC Duplex SM Patch Cord 0.9 mm dia of suitable length (i) Size 0.9mm dia (ii) Insertion Loss <=0.2 db, max 0.3 db (iii) Return Loss PC>=45dB, UPC>=50dB, APC>=60dB (iv) Connector Ferrule Ceramic (v) Apex Offset <50um (vi) Fiber Height +-100nm (vii) End Face Radius of Curvature 7mm<R<25mm (viii) Repeatability <=0.2 dB 1,000 times mating cycles (ix) Working Temp -40deg C to +85 deg C Make : Dlink, Ubiquiti, Cisco (e) SC Simplex Coupler/Adaptor (i) Insertion Loss <=0.2 dB for Zirconia Sleeve (ii) Sleeve/Ferrule Withdrawl Force 2.0N to 5.9N Make : Dlink, Ubiquiti, Cisco (f) Adaptor Panel (i) 6 port adaptor Panel for SC Adaptors Make : Dlink, Ubiquiti, Cisco (g) SC-SM-Simplex Pigtail of suitable length (i) Insertion Loss <=0.2 db, max 0.3 db (ii) Return Loss PC>=45dB, UPC>=50dB, APC>=60dB (iii) Connector Ferrule Ceramic (iv) Apex Offset <50um (v) Fiber Height +-100nm (vi) End Face Radius of Curvature 7mm<R<25mm (vii) Repeatability <=0.2 dB 1,000 times mating cycles (viii) Working Temp -40deg C to +85 deg C
(h) CAT6 UTP 24 AWG Patch Cord of suitable length, Plug 30U snag less Make : Dlink, Finolex Seamless Integration of the above PLC Panels into the Existing SCADA System incorporating (a) Development: (i) SCADA Screens for new Updated Panel configuration (ii) Layout for App new Updated Panel configuration (iii) Report Format new Updated Panel configuration (b) On-site development: (i) Modifications in SCADA Screens (ii) Modifications in reporting format (iii) Modifications in App layout
The quoted cost shall deem to include the cost of communication for 12 months from the date of completion. Above All automation panel should connected to existing SCADA server and any other leftout devices and accessories require to commissioning should be consider and same should be include in quoted rates and department will not pay extra cost for the same. Make of Control Panel: Cimcon Software Pvt Ltd/ Reckronic Devices and Systems / Sombansi Schneider/Universal Switchgear. Note :- Cost for Synchronising of panel in to existing SCADA system is in contractors scope only and no extra payment shall be given to the contractor by the department.
Taking down cement plaster of any description etc. including raking out joints, hacking for key, scrubbing down with water, etc. Including removal of debris out side MD land complete all as specified and directed by Engr-in-charge.
Providing and applying fair finish 15mm thick plaster with ready mix prepacked proportioned dry mix mortar fair faces of brick wall or concrete surfaces, wall surfaces including transporting of material, mixing, curing, etc.complete as per direction of Engr-in-charge Note:- (i) Liquid water proofing compound will be measured and paid seperately as supply only
Supply only liquid water proofing compound.
Providing and applying fair finish 10mm thick plaster with readymix prepacked proportioned dry mix mortar fair faces of brick wall or concrete surfaces, on ceiling including transporting of material, mixing, curing, etc.complete as per direction of Engr-in-charge.
M& L for applying 1mm thick wall care putty on walls complete all as specified and directed by Engr-in-Charge
M & L for preparing new surfaces of wall and apply two coats of distemper oil emulsion white or tinted over and incl one coat primer on walls complete all as specified and directed by Engr-in-Charge.
M & L for preparation of old wall surface and applying one coat of distemper oil emulsion white or tinted complete all Sqr as specified and directed by Engr-in-Charge.
M & L for preparation of newly plastered surface of ceiling and applying two coats of distemper oil emulsion white or tinted over one coat primer complete all as specified and directed by Engr-in-Charge.
Providing & applying anti algal water-based Elastomeric exterior wall finish newly plastered surfaces including surface preparation, applying suitable wall Prime seal primer 8-10 Sqm per ltr coverage area and application of two coats (base coat 4.2-4.7 & top coat 6-6.5 sqm per ltr coverage area) of paint by roller etc. complete
Material and labour for applying two coats of oil emulsion distemper over a coat of primer including 1mm thick wall care putty on old decorated surfaces of wall. Complete all as specified and directed by Engineer-In-charge
Material & Labour for applying two coats of oil bound distemper on old decorated ceiling incl complete removal of existing treatment by washing, rubbing down and over 1mm thick putty in two layer complete all as specified and directed by Engineer-In-charge.
M&L cleaning the existing surfaces of chequered tiles/paver blocks and applying one coats of floor guard paint (1st Sqm quality as approved by GE) complete all as specified and directed by Engr-in-charge
Dismantling plain or corrugated steel sheeting, any gauge, thickness, including Nainital or similar pattern roof Coverings coverings.
ML pre-painted galvatume aluminum zinc coating Gl based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified including making grooves of minimum 50mm into brick walling and inserting the sheets into these grooves including working platform/scaffolding) Complete all as specified and as directed by Engr-in-Charge
S&F in replacement SMC PANEL TANK confirming to Panel must be ISI Marked and have ISI Logo with CML and Batch Number along with ISI Code.(ISI 14399 Part-1 & Part-11-2006) of the under mentioned size (3mt x 2mt x 1mt) and capacity (06 KL.) Made out of HOT PRESS MOULDED SHEET MOULDING COMPOUND (SMC) Panels of size 1005mm X 1005 mm. The flange should be perpendicular to the main surface. The shape should be Trunk Type for extra strength and 90 degree flanges predrilled for bolting. All the Flanges of the Panel should have maximum 13 Nos. holes for fastening/joining the panels to one another. Hot Pressed Moulded SMC Pre Drilled Corner Pieces with built-in ribs of the size 75mm X 75 mm should be provided for 90 degree joints of tank walls or wall to base or wall to roof joints complete Hot Dipped Galvanized (HDG) hardware nuts, bolts and washers. Special sealant having excellent UV Resistance as well as suitable for portable water, complete with Top Covered construction having Man-Hole with Cover of Dia 600mm and internal FRP Ladder. The tank after erection and assembled as per Manufacturer Specification's shall be filled with water upto overflow level, which will be placed near the roof of the tank and test for leakages rectified any leakage found during the testing should be rectified to make it 100% leak proof complete as per direction of Engineer-in-Charge. (ISI Logo & CML number must be printed on all Panels). NOTE: (i) Rate quoted shall deemed to be inclusive of internal and external ladder made out of FRP/ Pultruted Section. MS supporting channels and necessary PVC profile including FOUNDATION, GRILLAGE, UNLOADING, SHIFTING & OTHER CIVIL COMPONENT IN CLIENT SCOPE. Including demolition/dismantling of RCC Storage tank.
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.33 MB
Tenderdocuments.pdf
Tender Documents • 1.11 MB
BOQ_843042.xls
BOQ • 1.60 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at [email protected].