Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹11.7 LAdmitted-Finance 81 MRIDULA BHAWAN CHATRIBARI GUWAHATI 700001 ASSAM | KOLKATA | WEST BENGAL | 700001 | ₹11.7 L | L1 | Admitted-Finance |
| 2 | L2₹12.2 L+₹51,000 (4.36%)Admitted-Finance | ₹12.2 L+₹51,000 (4.36%) | L2 | Admitted-Finance |
| 3 | L3₹12.4 L+₹68,000 (5.81%)Admitted-Finance | ₹12.4 L+₹68,000 (5.81%) | L3 | Admitted-Finance |
| Sl No | Description | Qty | Unit | Das Consultancy And Agency Services L1 | M/S B.K ASSOCIATES L2 | DIBAKAR PATHAK L3 |
|---|---|---|---|---|---|---|
| 1.00SL Subansiri | ||||||
| 1.01 | (i) Main deck plate near battery box has been found heavily corroded and damaged; the same has to be cropped and renewed with MS plates of thickness matching the existing structure.
(ii) Aft side PORT & STBD railing pipe was found damaged, Galley fresh water pipe found damage same needs to be renewed with an existing-size pipe.
(iii) Officer & Crew cabin and officer's dining area plyboard & chequered plate Supporting angle were found damage same has to be renewed with an existing-size angle as required as per the direction of EIC/Surveyor. | 250 | KG | 200 ₹50,000 Lowest | 550 ₹1,37,500 | 600 ₹1,50,000 |
| 2.00(i) 2 nos. Blowers in the crew cabin & officers' toilet were found non-functional, same have to service/repair include inspection of electrical connections, motor, impeller, bearings, wiring, switches, and all associated components. (ii) Main engine (PORT) electrical panel board was found non-functional; the same has to be checked. (iii) Complete inspection, testing, fault-finding, and rectification of the vessel's AC and DC electrical distribution system, including cables, switchboards, junction boxes, distribution panels, control pannel, earthing arrangements, lighting pannel, battery charging system, and all associated accessories, as required and make operational as per direction of EIC / Surveyor. | ||||||
| 2.01 | Labour+machining+consumable charges | 1 | Comp. Job | 45,000 ₹45,000 | 30,000 ₹30,000 Lowest | 30,000 ₹30,000 Lowest |
| 2.02Cost of spares/material (actual bill/invoice + 10%) | ||||||
| 3.00Heavy water leakage observed from the wheelhouse air-conditioning unit same has to be checked and rectified with Complete servicing, cleaning, and testing, of the Air Conditioning Unit, including cleaning of air filters, evaporator and condenser coils, checking refrigerant gas pressure, electrical connections, insulation, and all associated components as required as per direction of EIC/Surveyor. | ||||||
| 3.01 | Labour+machining+consumable charges | 1 | Comp. Job | 20,000 ₹20,000 Lowest | 20,000 ₹20,000 Lowest | 20,000 ₹20,000 Lowest |
| 3.02Cost of spares/material (actual bill/invoice + 10%) | ||||||
| 4.00(i) Rudder indicator on wheelhouse found non-functional; the same has to be repair/renewed as required, with complete line checking. (ii) The potentiometer installed in the Steering room shall be thoroughly inspected, tested, calibrated, and repaired/replaced if found defective (iii) All meter, indicator, navigation display, nautical instruments, operation/command devices and propulsion control to check then repair/renew; as required as per direction of EIC/Surveyor. | ||||||
| 4.01 | Labour+machining+consumable charges | 1 | Comp. Job | 60,000 ₹60,000 | 10,000 ₹10,000 Lowest | 10,000 ₹10,000 Lowest |
Tender Value
₹38.4 L
EMD Value
₹77,000
Closing Date
20 Jul 2026, 11:30 amClosed
Director
IWAI, Pandu Port Complex, Pandu, Guwahati-12
Annual Afloat Repair of SL Subansiri, SL Lohit and SL Kosi for the year 2026-27
2026_IWAI_915795_2
IWAI/GHY/SUBANSIRI/4(02)/26-27
Open Tender
Marine Works
Works
90 days
(NW-2)
As per tender document
2 documents required · 2 mandatory
₹5,900
Yes
IWAI FUND PLAN
₹77,000
Yes
30 Jul 2026
4 Jul 2026
21 Jul 2026
6 Jul 2026
20 Jul 2026
6 Jul 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1SL Subansiri | |||||
| 1.01 | (i) Main deck plate near battery box has been found heavily corroded and damaged; the same has to be cropped and renewed with MS plates of thickness matching the existing structure.
(ii) Aft side PORT & STBD railing pipe was found damaged, Galley fresh water pipe found damage same needs to be renewed with an existing-size pipe.
(iii) Officer & Crew cabin and officer's dining area plyboard & chequered plate Supporting angle were found damage same has to be renewed with an existing-size angle as required as per the direction of EIC/Surveyor. | 250 | KG | - | - |
| 2(i) 2 nos. Blowers in the crew cabin & officers' toilet were found non-functional, same have to service/repair include inspection of electrical connections, motor, impeller, bearings, wiring, switches, and all associated components. (ii) Main engine (PORT) electrical panel board was found non-functional; the same has to be checked. (iii) Complete inspection, testing, fault-finding, and rectification of the vessel's AC and DC electrical distribution system, including cables, switchboards, junction boxes, distribution panels, control pannel, earthing arrangements, lighting pannel, battery charging system, and all associated accessories, as required and make operational as per direction of EIC / Surveyor. | |||||
| 2.01 | Labour+machining+consumable charges | 1 | Comp. Job | - | - |
| 2.02 | Cost of spares/material (actual bill/invoice + 10%) | - | - | - | - |
| 3Heavy water leakage observed from the wheelhouse air-conditioning unit same has to be checked and rectified with Complete servicing, cleaning, and testing, of the Air Conditioning Unit, including cleaning of air filters, evaporator and condenser coils, checking refrigerant gas pressure, electrical connections, insulation, and all associated components as required as per direction of EIC/Surveyor. | |||||
| 3.01 | Labour+machining+consumable charges | 1 | Comp. Job | - | - |
| 3.02 | Cost of spares/material (actual bill/invoice + 10%) | - | - | - | - |
| 4(i) Rudder indicator on wheelhouse found non-functional; the same has to be repair/renewed as required, with complete line checking. (ii) The potentiometer installed in the Steering room shall be thoroughly inspected, tested, calibrated, and repaired/replaced if found defective (iii) All meter, indicator, navigation display, nautical instruments, operation/command devices and propulsion control to check then repair/renew; as required as per direction of EIC/Surveyor. | |||||
| 4.01 | Labour+machining+consumable charges | 1 | Comp. Job | - | - |
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.98 MB
BOQ_962597.xls
BOQ • 0.35 MB
Tenderdoc_Subansiri_Lohit_Kosi.pdf
Tender Documents • 4.10 MB
Corrigendum_LD.pdf
PDF • 0.35 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .