Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹34.7 LAccepted-Finance HN12 GALI NO 4 KUSHAK NO 2 KADIPUR DELHI 36 | 36 | ₹34.7 L | L1 | Accepted-Finance Accepted |
| 2 | L2₹37.0 LAccepted-Finance 975 E LOHIYA GALI NO 4 BABARPUR DELHI 110032 | SHAHDARA | DELHI | 110032 | ₹37.0 L | L2 | Accepted-Finance Accepted |
| 3 | L3₹41.1 LAccepted-Finance | ₹41.1 L | L3 | Accepted-Finance Accepted |
| 4 | L4₹41.3 LAccepted-Finance 1033 E FIRST FLOOR LOHIYA GALI NO 5 BABARPUR SHAHDARA DELHI 110032 | SHAHDARA | DELHI | 110032 | ₹41.3 L | L4 | Accepted-Finance Accepted |
| 5 | L5₹44.4 LAccepted-Finance | ₹44.4 L | L5 | Accepted-Finance Accepted |
Tender Value
₹59.2 L
EMD Value
₹1.2 L
Closing Date
5 Mar 2026, 3:00 pmClosed
Executive Engineer(E)
Judiciary Electrical Division-I, PWD, Yamuna Western Bank, Lok Nayak Setu, New Delhi-110002
(SH Comprehensive maintenance of Various type Air Conditioners and Air Washer, duct cleaning and laying of cable installed at various locations)
2026_PWD_287745_1
300/EE(E)/JED-1/PWD/2025-26
Open Tender
Electrical Works
365 days
Prison Complex Mandoli
Please refer Tender documents.
2 documents required · 2 mandatory
₹0
₹1.2 L
10 Mar 2026
25 Feb 2026
5 Mar 2026
25 Feb 2026
5 Mar 2026
25 Feb 2026
Comprehensive running maintenance and servicing of various WTAC/ STAC Air Conditioners of (1.5 to 2.0 TR) of different makes and models installed at Prison Complex, Mandoli including labour charge and replacement of all defective minor parts, i/c supplying and charging of R-410/R-22/R-32 refrigerant gas in the compressor in case of leakage (Except replacement of compressor) i/c checking the units oiling, greasing, chemical cleaning of condenser coil, cooling coil i/c replacement of defective parts, Air filter, running capacitor, starting capacitor, starting relay, overload realy thermostat switch, wiring kit, 15/20 Amp plug top/Industrial socket, flexible connection cable/ lead, drain pipe and tightening the loose connection, complete as required.
Summer Season 167 Nos. for 8 Months (with minimum staff 1 No. Technician and 1 No. Helper in 9 AM to 5 PM)
Dismantling and reinstallation of existing 1.5/2.0 TR STAC units including removing copper pipe connection, drain pipe i/c disconnection from electrical mains & repairing of wall with cement/POP etc. and then fiixng the ac unit at the desired location as per directions of Engineer in charge.
Supplying and replacement of following accessories in the existing split type AC units/WTAC units including connection, testing etc. complete as required.
Compressor 2.0 T.R. capacity
Compressor 1.5 T.R. capacity
Cooling Coil for 1.5/2.0 TR capacity AC
Condenser Coil for 1.5/2.0 TR capacity AC
PCB remote hand set
PCB kit for 1.5/2.0 TR capacity AC
Blower indoor unit
Providing, Replacement & Laying of refrigerant copper piping (5/8" & 3/8" dia) alongwith black rubber AC insulation pipe from indoor unit to outdoor unit of split type AC duly insulated along with 2.5 sq.mm 4 core PVC insulated PVC sheathed flexible copper conductor cable and 20mm size of cotton thread ribbed PVC flexible pipe from drip tray of AC units to drain pipe i/c gas charging of suitable refrigerant etc. as reqd
Supplying , Installation , testing and commissioning of 2.0 Tr Capacity Indoor AC unit , Copper Refrigerant , Compatible with all Eco Friendly Refrigerant gas capable for Cooling , dehumidifying , air circulating suitable for operation on 230V 50Hz Single Phase AC Supply etc including connection with outdoor AC Unit etc complete as reqd and as per directions of Engineer in charge.
Supplying , Installation , testing and commissioning of 2.0 Tr Capacity Outdoor Unit STAC of following Capacity suitable for operation on 230V , 50Hz Single phase AC Supply , Capable of performing cooling , complete with condenser coil , compressor , valve set fitting etc complete as reqd.
Supply & replacement of existing faulty (0.75KW) 1 HP self priming monoblock pump set i/c installation, testing, commissioning etc. complete as reqd at site.
Supply & replacement of V- Belt of pulley of various sizes (A38, A84, B116, B117, B142, B144, B168, B131, B159 etc. as per site requirement) i/c fixing, commissioning etc, complete as required at site as per direction of Engineer-in-charge)
Supply & fixing of ISI marked heavy duty cross corrugated evaporative type honeycomb cooling pads of 200 mm thickness made of cellulose paper, specially treated flute media capable of absorbing and retaining water to provide the maximum cooling, treated with anti-rot, anti corrosion coating & regidifying resin in existing air washer pad frames with steel screws, washers including cutting to required shape & size etc. complete as required at site.
Providing, laying, testing & commissioning of 'B' class medium duty G.I. pipe conforming to IS 1239 including welding, fittings like elbows, tees, flanges, tapers, nuts, bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required :
Providing and fixing of 25 mm nominal ball valve (SS) of approved quality, High or low pressure, with plastic floats complete.
Supplying and replacement of GI Wire mesh Air washer pre filter of following size suitable for exesting air washer i/c connection etc. complete as per site requirement.
610 mm. x 610 mm.
305 mm. x 610 mm.
Dismantling, servicing and painting of following capacity three phase blower motors , providing & replacement of motor seal, bearing, rusted nuts, bolts and greasing/ lubricating all necessary parts along with cartage/ loading/ unloading from site to workshop & back with reinstallation at site etc. complete as required.
Supplying & fixing of canvas connection made out of fire retardant cloth properly stitched & fixed in suitable size GI frame work having holes for nut bolts in Air washerunit complete etc. as reqd.
Supplying, installation, balancing and commissioning of fabricated at site GSS sheet metal rectangular/ round ducting complete with neoprene rubber gaskets, elbows, splitter dampers, vanes, hangers, supports, bends, transitions, reducers, end caps, collars etc as required complete in all respect in confirmation with IS : 655 and approved drawings and specifications of following sheet thickness complete as required.
Thickness 0.80 mm sheet
Supplying, installation, testing & commissioning 450 mm metal body 900 RPM heavy duty exhaust fan including supplying and fixing of gravity louvers & shutters in the existing opening, including making goodthe damage, connection, testing, commissioning etc. as reqd.
Supply & replacement of following faulty electrical accessories in the existing starter panels of air washers i/c testing, commissioning etc, complete as requied at site and as per direction of engineer in charge.
Contractor MNX 18
Contractor MNX 25
Contractor MNX 40
Motor Protection Relay (Range 8A-22A) 240 V AC MPR 300
Star Delta Electric Timer range 3-120 Sec., 240 V AC.
Single Phase Preventor 3 PH, 3 W, 2 Sec. (ON delay), 7 Sec. (OFF delay) 65 V AC Asymmetry , 415 V AC, 1 C/O.
Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, Ics=100% Icu and Operational Voltage 690V etc. as required.
250 A, 36 KA,FPMCCB
150 A, 16 KA,TPMCCB
400 A,50KA,FPMCCB
63A, FP MCB
Operation and routine maintenance of Air washer/Air scrubber mechanical ventilation axial fans installed in CJ No. 11 to 16 & Admin Block at Mandoli Prison Complex i/c. monitoring of the complaints i/c cleaning of chimney, air grills, tank, ducts etc. as per direction of Engineer-on-charge at site of work on all days of the week (including Sundays and Holidays) etc. complete as required at site. Minimum deputies staffs: a) Operator/ mechanic – 2 Nos. b) Helper/ Khallasi – 2 Nos.
Less of Account of buy back of item no. 1 to item no. 19 dismantled material
Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required
Above 95 sq. mm and upto 185 sq. mm (clamped with25/40x3mm MS flat clamp)
Above 185 sq. mm and upto 400 sq. mm (clamped with 40x3mm MS flat clamp)
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required.
Above 95 sq. mm and upto 185 sq. mm
Above 185 sq. mm and upto 400 sq. mm
Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/ submain wiring/ cable as required.
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 kV grade as required.
3½ X 120 sq. mm (45mm)
3½ X 150 sq. mm (50mm)
3½ X 300 sq. mm (70mm)
Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc. direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc. complete as required.
(a)90 mm dia (OD-90 mm & ID-76 mm nominal)
(b) 160 mm dia (OD-160 mm & ID-135 mm nominal)
Cutting of RCC slab for laying of cable i/c making good with cement concrete 1:3:6 (1 Cement:3 Coarse and 6: Grade stone) etc as required at site .
Core cutting of following size in the existing wall for entry of suitable size aluminium power cable i/c making good the same etc. complete as per required. (a) Dia 5”, Depth 18-28”
Providing and carrying out cleaning of air washer masonry ducts by complete removal of all debris, dust and loose materials from inside the ducts, complete in all respects. The work shall include inspection, documentation of all cleaned areas, use of approved mechanical and/or manual methods suitable for masonry ducts without causing damage to the duct structure, collection, transportation and safe disposal of all debris including white washing of internal walls of duct. The item includes compliance with all applicable safety regulations and directions of the Engineer-in-Charge.
Supplying & fixing of powder coated extruded aluminium Return Air Grills with louvers but without volume control dampers complete in confirmation to SMACNA/IS and as per specifications complete etc. as required.
Please Enable Macros to View BoQ information
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 2.41 MB
BOQ_381400.xls
BOQ • 0.41 MB
Download all tender documents and submit your bid