Loading…
Loading…
Tender Value
₹28.7 L
EMD Value
₹57,400
Closing Date
19 Aug 2026, 11:00 amClosed
No
No
Single Packet System
Normal Tender
No
Not Applicable
Lowest to Highest
60 days
Expenditure
Capital (Works)
Above/Below/Par
TENDER
13 conditions · 2 needing a document upload
No Financial credentials are required for tenders having advertised value up to Rs.50 lakhs.
No Technical credentials are required for tenders having advertised value up to Rs.50 lakhs.
26 conditions · 2 needing a document upload
Uploading of Scanned copy of Statement of Bank details, PAN & GST.
Compliance with Public Procurement (Preference to Make inIndia) Policy: This tender complies with Public Procurement(Preference to Make in India), Order 2017-Revision dated19.07.2024 of Department of Promotion of Industry and InternalTrade, Ministry of Commerce and Industry, Govt. of India (hereinreferred to as PP-PIM), circulated vide Ministry of Railways(Railway Board)'s letter No.2020/RS(G)/779/2/Pt.1 (E3322671)dated 20.08.2024, and all its amendments. Only Class-I localsuppliers (as defined in PP-PIM) shall be eligible to bid for list ofitems specified in Ministry of Railways (Railway Board)'s letterno.2025/RS(G)/779/3 (E3488356) dated 02.05.2025. For otheritems, only Class-I and Class-II local suppliers are eligible to bid.At the time of bidding, each bidder is required to indicatepercentage of local content (as defined in PP- PIM) and provideself-certification that the item offered meets the local contentrequirement for "Class-I local supplier"/"Class-II local supplier",as the case may be. If this self-certification is not submitted, thebid will be summarily rejected. For contracts above Rs.10 crores,the provisions of Para 9(c) of PP-PIM shall be additionallyapplicable. For the purposes of this NIT, the "local content" (asdefined in PP-PIM) requirement to categorize a supplier as"Class-I local supplier" is minimum 50% and for "Class-II localsupplier" is minimum 20%. Also, the Margin of PurchasePreference (as defined in PP-PIM) is 20%. The procedure forpreference to Make in India shall be as specified in PP-PIM.Uploading of self-certificate for meeting the local contentrequirement for "Class-I local supplier"/"Class-II local supplier",as the case may be (proforma attached). Non- submission of thiscertificate will lead to summary rejection of bid. ( Click here to download Format)
Please enter the percentage of local content in the material being offered. Please enter 0 for fully imported items, and 100 for fully indigenous items. The definition and calculation of local content shall be in accordance with the Make in India policy as incorporated in the tender conditions.
1) SKLR (SAKLESHPURA) - Re-construction of SSE/Bridge Office in lieu of existing AC shed office over existing SSE/Works Office. 2) Proposed construction of 20 bed Running room at SAKLESHPURA. 3) SKLR (SAKLESHPURA) - Augmentation and Upgradation of Crew Lobby at SAKLESHPUR.
Y-E-29-2026-27-62
Y-E-29-2026-27-62
Open
Works - General
120 Days
Dharwad, Karnataka
₹0
₹57,400
19 Aug 2026
29 Jul 2026
5 Aug 2026
203 items across 3 schedules
| # | Description | Unit | Qty | Rate | Amount |
|---|---|---|---|---|---|
| — | — | — | 4,93,351.72 | ||
| — | 20.00 | — | — | ||
| Platform surface / concrete / Road cutting for excavation of cable trench 300 mm wide x 300 deep, re-fitting of soil and re-plastering of excavated trench with cement on the PF's to bring original shape. | — | — | — | 14,959.8 | |
| — | 150.00 | — | — | ||
| Supply of LTUG Cable with Alu conductor, XLPE insulated and armoured, 4 x 25 sq mm as per IS-7098 part -1 or latest. | — | — | — | 24,750 | |
| — | 150.00 | — | — | ||
| Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of Upto 35 sq. mm size direct in ground including excavation and refilling the trench etc. as required, but excluding sand cushioning and protective covering. | — | — | — | 37,950 | |
| — | 100.00 | — | — | ||
| Supply of 50 mm Diameter PE 100, PN 6 HDPE Pipe for safety of cable. | — | — | — | 5,460 | |
| — | 100.00 | — | — | ||
| Laying of HDPE Pipe of dia 50 mm grade PE-100 with pressure of PN 6 for safety of cables and all the ends should be sealing with bituminous compound. | — | — | — | 1,500 | |
| — | 12.00 | — | — | ||
| Supply and Fixing of GI pipe 'B' class of dia 50 mm. for cable rising & protection including clamping, fixing arrangements and sealing with bituminous compound. | — | — | — | 9,696.12 | |
| — | 2.00 | — | — | ||
| Supply and fixing of LT cable terminal LILO box (Min size 300 x 230 x 120 mm) with Hinged door with 32 A strip connector. | — | — | — | 4,216.32 | |
| — | 1.00 | — | — | ||
| Supply and fixing of suitable box for Single phase energy meter (Meter shall be supplied by Railways). | — | — | — | 2,202 | |
| — | 40.00 | — | — | ||
| Wiring for circuit/ submain wiring along with earth wire with the 2 X 6 sq. mm + 1 X 6 sq. mm earth wire sizes of FRLSH / HFFR PVC insulated copper conductor, single core cable in surface / concealed medium class PVC conduit / cassing & capping as required at site. | — | — | — | 19,280 | |
| — | 150.00 | — | — | ||
| Wiring for circuit/ submain wiring along with earth wire with the 2 X 4 sq. mm + 1 X 4 sq. mm earth wire sizes of FRLSH / HFFR PVC insulated copper conductor, single core cable in surface / concealed medium class PVC conduit / cassing & capping as required at site. | — | — | — | 55,950 | |
| — | 300.00 | — | — | ||
| Wiring for circuit/ submain wiring along with earth wire with the 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire sizes of FRLSH / HFFR PVC insulated copper conductor, single core cable in surface / concealed medium class PVC conduit / cassing & capping as required at site. | — | — | — | 93,300 | |
| — | 28.00 | — | — | ||
| Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLSH / HFFR PVC insulated copper conductor single core cable in surface / Concealed medium class PVC conduit / Cassing & capping, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLSH / HFFR PVC insulated copper conductor single core cable etc. as required. (Group - A). | — | — | — | 33,292 | |
| — | 24.00 | — | — | ||
| Supplying and fixing suitable size GI box with modular plate and cover in front on surface / recess / concealed, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. / cassing & capping as per site requirement. | — | — | — | 13,080 | |
| — | 6.00 | — | — | ||
| Supplying and fixing suitable size GI box with modular plate and cover in front on surface / recess / concealed, including providing and fixing 6 pin 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. / cassing & capping as per site requirement. | — | — | — | 3,954 | |
| — | 1.00 | — | — | ||
| L.T. Earthing arrangements for hard soil using 50 mm C-Class GI Pipe- 2.7 Mtr length, soil treatment by spreading of 25 kgs each of salt and charcoal, duly painting earth pit with black paint and stenciling of earth resistance value with date, including supply and laying of 8 SWG G.I. wire and other hardware to connect equipment at site complete. | — | — | — | 5,783.9 | |
| — | 4.00 | — | — | ||
| Supply, erection, testing and commissioning of 45-Watt, 230 Volt AC, 50 Hz, IP 66 LED street light fitting along with lamp, driver with all connected materials for proper fixing and alignment conforming to specification No. SWR /LED LIGHT FITTING (Indoor /Outdoor)/011-2016 dt 18.04.16. | — | — | — | 10,489.64 | |
| — | 1.00 | — | — | ||
| Supplying and fixing 8-way, Double door, three pole and neutral (TPN), sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. | — | — | — | 3,010.44 | |
| — | 1.00 | — | — | ||
| Supplying and fixing 50 A to 63 A rating, 415 V, 10 kA, "C" curve, TPN miniature circuit breaker in the existing MCB DB complete with connections, testing and commissioning etc. as required. | — | — | — | 2,440.74 | |
| — | 5.00 | — | — | ||
| Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, "C" curve, Double pole miniature circuit breaker in the existing MCB DB complete with connections, testing and commissioning etc. as required. | — | — | — | 3,337.05 | |
| — | 6.00 | — | — | ||
| Supply and fixing of 5 star rated 1200 mm sweep BLDC ceiling fan with suitable remote, fan hooks with all necessary accessories as per specification. | — | — | — | 17,313.66 | |
| — | 4.00 | — | — | ||
| Supply assembly fixing and commissioning of 200 mm size BLDC Ventilating fan Including all other accessories complete. | — | — | — | 12,100 | |
| — | 8.00 | — | — | ||
| Supply, fixing, testing and commissioning of 22-watt 6500k batten 4 feet approx length LED lighting fixture as per specification SWR/LED LIGHT FITTING (Indoor /outdoor) /001-2016 effective from 18.04.2016 or latest. Including all other required accessories complete. | — | — | — | 1,855.6 | |
| — | 4.00 | — | — | ||
| Supply, fixing, testing and commissioning of 10 watt, 2 feet Approx length, 6500 k LED batten fixtures Including all other required accessories complete. | — | — | — | 712.96 | |
| — | 6.00 | — | — | ||
| — | 4.00 | — | — | ||
| — | 4.00 | — | — | ||
| — | 2.00 | — | — | ||
| — | 4.00 | — | — | ||
| — | 1.00 | — | — | ||
| — | 1.00 | — | — | ||
| — | 1.00 | — | — | ||
| — | 1.00 | — | — | ||
| — | 1.00 | — | — |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
HTML
nit.pdf
NIT
AdvanceCorrectionSlips1-11toGCC-2022.pdf
ATTACHMENT
GCCApril-2022.pdf
ATTACHMENT
JPOintenderdocumnets.pdf
ATTACHMENT
Tender booklet
ATTACHMENT
TB-Re-constructionofSSEBridgeOffice20BednewRRatSKLRandCrewlobbySKLR_2.pdf
ATTACHMENT
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .