Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹71.7 LAccepted-AOC | 1 | Accepted-AOC Quoted Amount accepted being reasonable and L1 bidder | |
| 2 | 2₹75.7 L+₹3.8 L (5.29%)Rejected-Finance WZ 409 0 B 1ST FLOOR PLOT NO 12 JANAK PARK HARI NAGAR NEW DELHI 110064 | NEW DELHI | WEST DELHI | DELHI | 110064 | 2 | Rejected-Finance Morethan L1 | |
| 3 | 3₹79.3 L+₹7.4 L (10.3%)Rejected-Finance 10 1 GROUND FLOOR WEST GHOSH PARA JAGATDAL JAGATDAL JAGATDAL NORTH 24 PARGANAS WEST BENGAL 743125 | 24 PARAGANAS NORTH | WEST BENGAL | 743125 | 3 | Rejected-Finance Morethan L1 |
| Sl No | Description | Qty | Unit | RADHA ENTERPRISE L3 | Flint India L2 | BHAUMIK CONSTRUCTION L1 |
|---|---|---|---|---|---|---|
| 1.00Sch 'A' Part -I Earthwork, Site Clearance, Demoltion & Dismatling | ||||||
| 1.01 | Surface excavation not exceeding 30 cm deep and averaging 15 cm deep and getting out in soft/loose soil complete all as specified and directed. | 55.5 | Sqm | 100 ₹5,550 | 30 ₹1,665 Lowest | 50 ₹2,775 |
| 1.02 | Excavation in trenches not exc 1.5 mtr wide & not exc 1.5 mtr in depth for foundation , taking out / laying of under ground cable, pole or stayetc and getting out in soft/loose soil complete all as specified and directed. | 1,017 | Cum | 300 ₹3,05,100 | 190 ₹1,93,230 Lowest | 295 ₹3,00,015 |
| 1.03 | Returning filling in including spreading leveling watering and well ramming in layers not exceeding 25cms spread any type of soil complete all as directed by Engr-in-Charge | 580 | Cum | 100 ₹58,000 | 60 ₹34,800 | 50 ₹29,000 Lowest |
| 1.04 | Removing excavated materials not exceeding 50 mtr and depositing where directed at a level not exceeding 1.5 mtr above the starting point. | 442 | Cum | 100 ₹44,200 | 60 ₹26,520 | 50 ₹22,100 Lowest |
| 1.05 | Supply and spreading fine river sand in trenches for cushioning of under ground cable all as directed by engr-in-charge at site
Note:- Only puned thickness shall be measured for payment. | 300 | Cum | 800 ₹2,40,000 Lowest | 900 ₹2,70,000 | 850 ₹2,55,000 |
| 1.06 | M & L for Moorum/red bajri filling in floors or pavings, laid in layers n exc. 15 cm thick, spread, levelled and rammed including watering complete all as specified and directed | 3 | Cum | 2,200 ₹6,600 | 700 ₹2,100 Lowest | 1,000 ₹3,000 |
| 1.07 | M&L Hardcore of broken stones gauge not exceeding 63 mm, deposited, spread and levelled in layers not exceeding 15 cm thick, watered and rammed to a true surface complete all as specified and directed. | 2.6 | CUM | 2,400 ₹6,240 | 2,500 ₹6,500 | 2,000 ₹5,200 Lowest |
| 1.08 | M&L for sand filling under floors or in foundations including watering and consolidation complete all as specified and directed. | 1.8 | Cum | 1,500 ₹2,700 | 700 ₹1,260 Lowest | 800 ₹1,440 |
| 1.09 | M&L for Polythene film, black, 150micron laid in floors complete all as specified and directed. | 24 | Sqm | 15 ₹360 Lowest | 60 ₹1,440 | 800 ₹19,200 |
Tender Value
₹77.7 L
EMD Value
₹1.5 L
Closing Date
22 Jan 2026, 6:00 pmClosed
CWE AF Panagarh
HQ CWE AF PANAGARH MILITARY ENGINEER SERVICES AIR FORCE STATION ARJAN SINGH PO AIR FORCE PANAGARH DIST BURDWAN WEST BENGAL PIN 713155
PROVISION OF UNDERGROUND CABLE AT CERTAIN LOCATION AND STAND BY POWER SUPPLY AT OTES HALL AND ALLIED SERVICES AT AF STATION ARJAN SINGH UNDER GE AF PANAGARH
2025_MES_739346_2
83107/PAN/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE AF PANAGARH
Please refer Tender documents.
8 documents required · 8 mandatory
₹1,000
GE AF PANAGARH
₹1.5 L
Yes
12 Feb 2026
7 Jan 2026
24 Jan 2026
7 Jan 2026
22 Jan 2026
15 Jan 2026
Sch 'A' Part -I Earthwork, Site Clearance, Demoltion & Dismatling
Surface excavation not exceeding 30 cm deep and averaging 15 cm deep and getting out in soft/loose soil complete all as specified and directed.
Excavation in trenches not exc 1.5 mtr wide & not exc 1.5 mtr in depth for foundation , taking out / laying of under ground cable, pole or stayetc and getting out in soft/loose soil complete all as specified and directed.
Returning filling in including spreading leveling watering and well ramming in layers not exceeding 25cms spread any type of soil complete all as directed by Engr-in-Charge
Removing excavated materials not exceeding 50 mtr and depositing where directed at a level not exceeding 1.5 mtr above the starting point.
Supply and spreading fine river sand in trenches for cushioning of under ground cable all as directed by engr-in-charge at site Note:- Only puned thickness shall be measured for payment.
M & L for Moorum/red bajri filling in floors or pavings, laid in layers n exc. 15 cm thick, spread, levelled and rammed including watering complete all as specified and directed
M&L Hardcore of broken stones gauge not exceeding 63 mm, deposited, spread and levelled in layers not exceeding 15 cm thick, watered and rammed to a true surface complete all as specified and directed.
M&L for sand filling under floors or in foundations including watering and consolidation complete all as specified and directed.
M&L for Polythene film, black, 150micron laid in floors complete all as specified and directed.
Excavating post holes or similar holes, each not exceeding 0.5 Cum, getting out in Soft/ Loose soil, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm, watering, and removing surplus soil to a distance n.exc 50m & making good surface complete all as specified and directed.
Taking down Existing DG Set of capacity 200 KVA From PS-I and shifting it to TMQ Power house and DG Set capacity 62.5 KVA From TMQ power house and shifting it to OTES ,cleaning , including Lugs,Nut Bolt installation and testing fixed with existing Panel/Changeover complete all as specified and as directed by Engr in Charge Note: (a) The cost of necessary taking dow & carrying out installed DG set through transportation by any of mechnical method shall be deemed to be included in quoted rate. (b) All precautions shall be taken by the contractor to carryout the DG set, necessary other equipments as required shall be considered in quoted rate. Any damages to DG while transportation and installation shall be responsiblity of contractor and the same shall be repaired on his cost. (c) The quoted rate shall also be inclusive of instalation of DG set at new location.
Taking down Existing distribution transformer 11KV/433 V of capacity 250 KVA From TMQ Power house to Main power house and 11KV/433 V of capacity 315 KVA From HQ Bldg to TMQ power house ,cleaning , including installation and testing and fixed with existing VCB/four pole structure complete all as specified and as directed by Engr in Charge Note: (a) The cost of necessary taking dow & carrying out installed transformer through transportation by any of mechnical method shall be deemed to be included in quoted rate. (b) All precautions shall be taken by the contractor to carryout the transformer, necessary other equipments as required shall be considered in quoted rate. Any damages to DG while transportation and installation shall be responsiblity of contractor and the same shall be repaired on his cost. (c) The quoted rate shall also be inclusive of installation of transformer at new location.
Sch 'A' Part -II B/R Work
M & L for Brickwork with fly ash bricks of class 7.5 and above as per IS 12894:2002, straight or curved on plan exc 6m mean radius, build in CM (1:6) complete all as specified and as directed.
M&L for 15mm thick rendering on fair faces of brick/concrete/ Stone surfaces in cement mortar 1:6 and finished even and smooth without using extra cement complete all as specified
M&L for applying 2 coats of cement base paint over and including a coat of primer over new wall surface.
M & L for providing cement concrete 1:3:6 type C-2 (using 40 mm graded stone aggregate) as in subbase incl necessary formwork even and rough to receive the topping layer all as specified and directed.
M & L for providing 75 mm thick cement concrete 1:2:4 type B-1 (using 20 mm graded stone aggregate) as in path, hardstanding incl necessary formwork even and smooth without using extra cement all as specified and directed.
M&L for glass dividing strips, 3mm thick and 38mm wide inserted in position, conform to design complete all as specified and directed.
S&F structural steel work as in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to I. S.1161- 1979 grade St.-240 all as directed and specified.
S&F for Mild steel plates Fe-410-W (Gde-E-250) quality-B (plain or chequered) channels, square cut or notched (ordinary and counder sunk) forming holes, without any attachment complete all as specified and directed.
S&F Pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of any colour as approved by GE having tensile strength of 550 Mpa as in roof covering, cladding to wall, fixed with self tapping screws complete all as specified and directed.
S&F Pre- painted galvalume aluminum zinc coating GI based plain steel sheet 0.50mm thick of any colour as approved by GE having tensile strength of 550 Mpa as in roof covering, eaves board, ridges, hips,valley gutters, drip and straight flashing cladding to wall etc, fixed with self tapping screws complete all as specified and directed.
M&L steel work as in hand rails, wind ties for roof including securing bolts, posts and struts in fencing including cutting top to shape as directed drilling holes, notching for wire etc flat iron fillets for securing wire mesh etc including all necessary drilling bolting or riveting etc and similar work confirming to Fe-290 Gde E-165 complete all as specified and directed.
M&L preparation of new steel surfaces of any description over 10 cm width or girth not otherwise described and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed.
S & F Chequered cement concrete colour tiles 30 cmx 30 cmx 20-22 mm thick, with grey cement and pigments, set, jointed and pointed in neat cement slurry in floors, steps etc over and including 20 mm thick screed bed in CM 1 :4 complete all as specified and as directed.
M&L for PCC 1:2:4 type B1 using 20mm graded stone aggregate for padestal coping incl necessary formwork finished fair using extra cement.
M&L for PCC (1:4:8) type D-2 with 40mm graded stone aggregate as in foundation filling & mass concrete in column & wall foundation complete all as specified .
S&F TMT Mild steel bars of any size, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends, striuups, spacers etc and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips all as specified and as directed.
M & L for RCC 1:2:4 type B 1(using 20 mm graded stone aggregate) in Foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete complete all as specified.
Sch 'A' Part -III E/M Work
M&L for Varmin dust proof LT junction box outdoor type of suitable size(700mm x600mm x 400mm) made out of MS sheet 3.15 mm thick, , powder coated(Seven Tank Process) , rear and front operated door ,SS sliding Bolt with locking arrangement on both sides , suitable aluminium busbar 200 Amp ,Indicator Lamp(RYB),I/C MCCB (100A,16KA,4P) and fixed on angle iron base suitable for pedastal mounting of size 50x50x6 mm for connecting cable on both side at least 2 feet height from GL as specified and directed
M&L for Varmin dust proof LT junction box outdoor type of suitable size(700mm x600mm x 400mm) made out of MS sheet 3.15 mm thick, , powder coated(Seven Tank Process) , rear and front operated door ,SS sliding Bolt with locking arrangement on both sides , suitable aluminium busbar 200 Amp ,Indicator Lamp(RYB),I/C MCCB (63A,16KA,4P) and fixed on angle iron base suitable for pedastal mounting of size 50x50x6 mm for connecting cable on both side at least 2 feet height from GL as specified and directed
M&L for Varmin dust proof LT junction box outdoor type of suitable size(700mm x600mm x 400mm) made out of MS sheet 3.15 mm thick, powder coated(Seven Tank Process) , rear and front operated door ,SS sliding Bolt with locking arrangement on both sides , suitable aluminium busbar 200 Amp ,Indicator Lamp(RYB),I/C MCCB (40A,16KA,4P) and fixed on angle iron base suitable for pedastal mounting of size 50x50x6 mm for connecting cable on both side at least 2 feet height from GL as specified and directed Note for Item no. 1.32 to 1.34 (a) Cost of aluminium busbar 200 Amp ,Indicator Lamp(RYB), MCCB of specified capacity and angle iron base shall be inculded in quoted rate. (b) The quoted rate shall be inclusive of all materials listed in items as well as suitable Foundation etc complete
Design, Fabrication, Testing & Commissioning of Varmin dust proof LT Panel outdoor type of suitable of size (1000mm x 800mm x400mm) made out of MS sheet 3.15 mm thick, Type tested conforming to IEC 61439, powder coated(Seven Tank Process) , rear and front operated door with locking arrangement on both sides , suitable aluminium busbar (300 Amp) and fixed on angle iron base suitable for pedastal mounting of size 50x50x6 mm at least 2 feet above GL to accomodating the following :- INCOMING :- (a) MCCB 100 Amps, 4 pole, 25 KA - 01(in coming) OUTGOING :- (b) MCCB 63 Amps, 4 pole, 16KA - 01Nos (out going) (c)MCCB 40 Amps, 4 pole, 16KA - 01Nos (out going) (d) Change over switch 125A-01 Nos (e)Digital Multi-functional Meters for measuring current, voltage and frequency,Power including CTs of suitable rating and class Note : The rate also inclusive of all material mentioned incl sl no (a) to (e) and P.C.C foundation etc complete.
Design, Fabrication, Testing & Commissioning of Varmin dust proof LT Panel outdoor type of suitable of size (1200mm x 1000mm x400mm) made out of MS sheet 3.15 mm thick, Type tested conforming to IEC 61439, powder coated(Seven Tank Process) , rear and front operated door with locking arrangement on both sides, suitable aluminium busbar (800 Amp) and fixed on angle iron base suitable for pedastal mounting of size 50x50x6 mm at least 2 feet above GL to accomodating the following :- INCOMING :- (a) MCCB 400 Amps, 4 pole, 36 KA - 01(in coming) OUTGOING :- (b) MCCB 160 Amps, 4 pole, 16KA - 01Nos (out going) (c)MCCB 100 Amps, 4 pole, 16KA - 02Nos (out going) (d) MCCB 80 Amps, 4 pole, 16KA - 01Nos (out going) (e ) MCCB 25 Amps, 4 pole, 16KA - 01Nos (out going) (f) Change over 400Amp-01 Nos (g)Digital Multi-functional Meters for measuring current, voltage and frequency,Power including CTs of suitable rating and class Note : The rate also inclusive of all material mentioned incl sl no (a) to (g) and P.C.C foundation etc complete.
Design, Fabrication, Testing & Commissioning of Varmin dust proof LT Panel outdoor type (after taking down of U/s panel with all panel mounting) of suitable of size (1200mm x 1000mm x400mm) made out of MS sheet 3.15 mm thick, Type tested conforming to IEC 61439, powder coated(Seven Tank Process) , rear and front operated door with locking arrangement on both sides , suitable aluminium busbar (400 Amp) and fixed on angle iron base suitable for pedastal mounting of size 50x50x6 mm at least 2 feet above GL to accomodating the following :- INCOMING :- (a) MCCB 250 Amps, 4 pole, 25 KA - 01(in coming) OUTGOING :- (b) MCCB 100 Amps, 4 pole, 16KA - 03Nos (out going) (c)MCCB 40 Amps, 4 pole, 16KA - 01Nos (out going) (d)Digital Multi-functional Meters for measuring current, voltage and frequency,Power including CTs of suitable rating and class Note : (a)The rate also inclusive of all material mentioned incl sl no (a) to (d) and P.C.C foundation etc complete.
Design, Fabrication, Testing & Commissioning of Varmin dust proof LT Panel outdoor type of suitable of size (1200mm x 1000mm x400mm) made out of MS sheet 3.15 mm thick, Type tested conforming to IEC 61439, powder coated(Seven Tank Process) , rear and front operated door with locking arrangement on both sides , , suitable aluminium busbar (400 Amp) and fixed on angle iron base suitable for pedastal mounting of size 50x50x6 mm at least 2 feet above GL to accomodating the following :- INCOMING :- (a) MCCB 200 Amps, 4 pole, 25 KA - 01(in coming) OUTGOING :- (b) MCCB 63 Amps, 4 pole, 16KA - 03Nos (out going) (c)MCCB 40 Amps, 4 pole, 16KA - 03Nos (out going) (d)Digital Multi-functional Meters for measuring current, voltage and frequency,Power including CTs of suitable rating and class Note : The rate also inclusive of all material mentioned incl sl no (a) to (d) and P.C.C foundation etc complete.
Design, Fabrication, Testing & Commissioning of Varmin dust proof LT Feerder Pillar board outdoor type of suitable of size (500*500*400 mm) made out of MS sheet 3.15 mm thick, Type tested conforming to IEC 61439, powder coated(Seven Tank Process) , rear and front operated door with locking arrangement on both sides , suitable aluminium busbar (400 Amp) and fixed on angle iron base suitable for pedastal mounting of size 50x50x6 mm at least 2 feet above GL to accomodating the following :- INCOMING :- (a) MCCB 250 Amps, 4 pole, 25 KA - 01(in coming) (b)Indicator lamp (RYB) Note : The rate also inclusive of all material mentioned incl sl no (a) to (b) and P.C.C foundation etc complete.
Design, Fabrication, Testing & Commissioning of Varmin dust proof LT Feerder Pillar board outdoor type of suitable of size (500*500*400 mm) made out of MS sheet 3.15 mm thick, Type tested conforming to IEC 61439, powder coated(Seven Tank Process) , rear and front operated door with locking arrangement on both sides fixed on angle iron base suitable for pedastal mounting of size 50x50x6 mm at least 2 feet above GL to accomodating the following :- INCOMING :- (a) MCCB 200 Amps, 4 pole, 25 KA - 01(in coming) (b)Indicator lamp (RYB) Note :- (i) The rate also inclusive of all material mentioned incl sl no (a) to (b) and P.C.C foundation etc complete. (ii) Make of BOQ item No. 1.32 to 1.40 :- Lauritz Knudsen Electrical & Automation (L & T)/ Milestone/ Legrand/ Seimens/ C & S Electric Ltd/ Schneider/Shalabh (India) Ltd/ M/s Power System & Controls/Indian Transformers Gurgoan
M&L Earthing complete with galvanized steel earth plate electrode 60cm x 60cm x 6.3 mm thick buried directly in ground( earth pit not less than 2.25 mtrs deep below normal ground level )with the top edges of plate not less than 1.5 mtrs below normal ground level connected to GI wire 4mm by means of GI nuts, bolts check nuts and washers earth lead protected by 15mm dia GI pipe medium grade and connected to main distribution board/earthing test point all as shown in electrical plate No 3 of SSR part 1 and all as specified including testing on completion. Notes:-The unit rate also including for excavation, earth work in any type of strata, plain cement concrete 1:3:6 mix, Type C1 pit, 40mm thick RCC 1:2:4 mix , type B1 cover reinforced with 8mm dia TMT bars @150mm C/C both ways ,GI funnel with GI watering pipe 20mm dia med gde ,wire mesh, protection pipe 15mm dia GI pipe medium grade for earth lead upto 7.50m long complete .
M&L Earthing complete with galvanized steel earth plate electrode 60cm x 60cm x 6.3mm mm thick buried directly in ground( earth pit not less than 2.25 mtrs deep below normal ground level )with the top edges of plate not less than 1.5 mtrs below normal ground level connected to GI strip of size 32 x 6mm by means of GI nuts, bolts check nuts and washers earth lead protected by 40mm dia GI pipe medium grade and connected to main distribution board/earthing test point all as shown in electrical plate No 3 of SSR part 1 and all as specified including testing on completion. Notes:-The unit rate also including for excavation, earth work in any type of strata, plain cement concrete 1:3:6 mix, Type C1 pit, 40mm thick RCC 1:2:4 mix , type B1 cover reinforced with 8mm dia TMT bars @150mm C/C both ways ,GI funnel with GI watering pipe 20mm dia med grade ,wire mesh, protection pipe 40mm dia GI pipe medium gde for earth lead upto 7.50m long complete .
Materials and labour for Earthing complete with Copper earth Plate electrode 600 mm x 600 mm x 3.15 mm thick, burried directly and preferably vertically in ground, earth pit not less than 2.25 Mtr deep below ground level with top edge of the plate not less than 1.5 m below ground level connetced with 20x3 mm copper strip by means of nuts, bolts, check nuts and washers made of galvanised iron to be protected by galvanised iron pipe 40 mm bore (medium grade) and other end connected to earthing test point including providing funnel and watering pipe 20mm bore galvanised iron pipe (medium grade), wire mesh, charcoal or coke and common salt in alternate layer of 15cm (compacted thickness) all round the earth electrode, concrete earth pit in PCC (1:3:6) type C-1 (with 20mm graded stone aggregate), 50mm thick precast RCC (1:2:4) cover slab (re-inforced with 8mm dia TMT bar @ 15 cm C/C bothways and suitable handle made of 10mm dia) including necessary earth work, excavation, returning filling and removal of surplus earth upto a distance not exceeding 50 m etc all as shown on electrical plate No. 3 of MES Schedule Part-I(2009) complete test and testing on completion all as specified and as directed.
S&F including testing and commissioning of LT under ground cable XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric cable (heavy duty) with multistranded aluminium conductor,1100 Volts grade in trenches/on wall/poles laid in ducts/inside protection pipe of the following cross sectional area including cable glands,lugs and suitable size of MS saddle clips (where ever cable laid in ceilings / walls without cable duct) complete all as directed by the Engr-in-Charge.
300 Sqmm x 3.5 core
185 Sqmm x 3.5 core
120 Sqmm x 3.5 core
16 Sqmm x 4 core
70 Sqmm x 3.5 core
50 Sqmm x 3.5 core
35 Sqmm x 3.5 core
25 Sqmm x 3.5 core
6 Sqmm x 2 core
Supply,laying,testing & commissioning XLPE insulated, PVC bedded, galvanized steel strip or wire armoured electric power cables (heavy duty) with aluminium conductor, 11000 Volts, grade cross section area ,laid 95 Sq mm 3 core laid in trenches/ floor/ walls complete all as specified and directed.
Note for Item no. 1.44 to 1.54: (a) The contractor after sample approval shall take approval of authorised dealerr of make. The Cable shall be purchased from authorised dealer of Manufacturers. The Engr-in-Charge shall verify the authorised dealer from th company before accord of approval of authorised dealer. (b) The insitu test of all the cable received shall be carried out and the report shall be kept on record and shall attach with RAR/Final bill. The quoted rate shall be inclusive of the same. (c) The contractor shall submit the purchase voucher of the same and shall got verifie d by Engr-in-Charge before considering for payment. The non-submission may lead to non-payment of RAR/Final bill of above items.
Supply, jointing and testing cable jointing kit for 11KV (Earthed) grade cable for outdoor Heat shrink type joint complete with jointing materils and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 95 Sqmm. complete all as specified and directed.
Supply & fix HT 11 KV Gang operated air break switch outdoor type off load, disconnecting switch. Triple pole, each pole consist of galvanized steel base, HT insulators as per B.S.S./I.S. non ferrous knife and spring loaded contact, arcing horns of adequate section to break magnetizing current of the transformers horizontal GI pipe of adequate length for phase seperation, adequate length of GI pipes for operation from ground level and operating handle complete in both OFF and ON position. All ferrous parts hot dipped galavanized and non ferrous parta heavily tinned to withstand weather suitable for vertical mounting of capacity 200 Amps.
Supply and lay in trenches brick, common burnt in clay, building brick, sub class 'B' designation 75 for cable protection all as specified and directed .
Supply and fixing in replacement for GI protection pipe medium grade for cable protection incl all fittings laid in trenches or fixed on pole all as specified for 80 mm dia
Supply and fixing in replacement for GI protection pipe medium grade for cable protection incl all fittings laid in trenches or fixed on pole all as specified for 50 mm dia
M&L for boring of holes under road, pavement, hard standing by trenchless technology/manual excavation as necessary including machine ,tools etc as per site requirment.
Supply and fixing junction box IP 66 thermoplastic polycarbonate enclosure totally shock proof ,weather proof, rust proof, dust proof, water proof, halogen free, silica free having internally embedded gasket technology with glow wine test at 96 C of size 130 x 180 x 77 mm with epoxy terminal, MS clamp SP MCB 6 amps cable glands lock nut complete for street light poles all as directed and specified (Make-Sintex/Hensel / Havells)
Supply and fixing Integral LED street light luminaire 45 W comprising of power coated die cast aluminium housing, working as a heat sink and toughened glass, having an ideal batwing pattern suitable for mounting on poles / 50mm OD pipe ingress protection IP 66,,10 KV SPD with rotating arrangement complete all necessary connections including testing on completion all as specified and as directed by the Engineer-in-Charge.Make :Cromption/Havells equivalent as approved by the GE
Supply and fixing Integral LED street light luminaire 90 W comprising of power coated die cast aluminium housing, working as a heat sink and toughened glass, having an ideal batwing pattern suitable for mounting on poles / 50mm OD pipe ingress protection IP 66,10 KV SPD with rotating arrangement complete all necessary connections including testing on completion all as specified and as directed by the Engineer-in-Charge.Make :Cromption/Havells equivalent as approved by the GE
Supply and draw two run of PVC Insulated PVC sheathed cable electric control cable (Heavy duity) with stranded copper conductor of size 2.5 Sqmm and one run of 1.5 Sqmm cable drawn into steel pole for connection or security/street light fitting from junction box all as directed and specified
Supply & fix 20mm dia black steel conduit pipe medium grade incl all fixing accessories such as clamp,nut bolt, washer etc all as specified and as directed.
M & L for street light bracket made out of GI pipe light grade 40 mm dia 1.2 mtr length bent to shape and reduced to required size at top upto 1.5m length by cutting, welding and well finishing including MS clamp of flat iron of size 40 x 6 mm suitable length 2 Nos complete with drilling, hole, fixing with nuts bolts and washers including painted with two coats aluminium paint over a coat of red oxide primer.
M & L for street light pole made out of 50mm bore GI Tubing medium grade 1.5 mtr long,bend to shape as requaired , fixed with clampetc incl spary painting of pole and making holes for cable entry complete all as specified and directed.
BLANK
M & L Sub main wiring in PVC Casing caping with two single core cable PVC insulated cable with 4.0 Sqmm (Nominal area) multi stranded copper conductor FRLSH cable 1100 volts gde incl earth continuity conductor using PVC insulated cable of stranded copper conductor of size 4.0 Sqmm connected to common earth dolly and drawing into PVC Casing caping of 25 mm dia medium grade size, making good the disturbed surfaces complete. NOTE : (a) Two run of submain wiring cable alongwith one run of earth wire shall be measured as one length. (b) All materials shall be ISI Marked .
M&L for point wiring complete with 2 runs of 2.5 sqmm single core PVC insulated unsheathed FRLS cable 1100 volts grade ISI marked with multi stranded copper conductor drawn through and including PVC casing caping and accessories such as junction boxes , sockets,bends etc ISI marked medium grade concealed in wall/fixed to roof/ceiling etc and including provision of 2.5 sqmm PVC insulated multistranded unsheated copper conductor cable FRLSH ISI marked as earth continuity conductor as specified and as directed.- NOTE: (i)One run of PVC casing caping ,two runs of PVC wire and one run of earth wire will be measured as one length. (ii) All materials shall be ISI Marked
S & F sheet metal enclosure /DB, single door SPN, 2 ways without bus bar complete.
M&L MCBs suitable for operation of Acs , SPN 40 Amps,'C' curve, 10 kA.
Supply and fix DBOXx MCB Protected power unit with two pin and earth plug and socket , MCB's of capacity 20 amps, DP, 'C' curve, complete all as specified and directed.
Schedule of Credit
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.36 MB
Tend_doc.pdf
Tender Documents • 1.98 MB
BOQ_837029.xls
BOQ • 0.33 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .