| 1 | L 1₹9.4 LAccepted-AOC NO 1055 MAIN ROAD ODIAMPET VILLIANUR PUDUCHERRY 605110 | CUDDALORE | TAMIL NADU | 605110 | L 1 | Accepted-AOC As per the chart generated L1 is accepted and AOC issued to L 1 | |
| 2 | L 2₹10.4 L+₹1.1 L (11.3%)Rejected-Finance NO 7 VANIDASAN STREET KOSAPALAYAM PUDUCHERRY 605013 | PONDICHERRY | PUDUCHERRY | 605013 | L 2 | Rejected-Finance Second Least | |
| 3 | L 3₹10.5 L+₹1.1 L (11.3%)Rejected-Finance | L 3 | Rejected-Finance Third Least | |
| 4 | L 4₹11.3 L+₹1.9 L (19.9%)Rejected-Finance NO 3 IIND CROSS STREET PERUMALPURAM VILLIANUR PUDUCHERRY 605 110 | PONDICHERRY | PUDUCHERRY | 605110 | L 4 | Rejected-Finance Fourth Least |
Tender Value
₹13.2 L
EMD Value
₹26,490
Closing Date
18 Dec 2023, 4:00 pmClosed
The, Executive Engineer, SBDI, PWD, Puducherry.
Office of the EE,SBDI,PWD,Puducherry.
Attending electrical repair works, replacement of light and fan fittings at PAP administrative building, Gorimedu, Puducherry
2023_PWDC1_14458_1
33/SBDI/2023-24/2
Open Tender
Electrical Works
Item Rate
30 days
Puducherry
Please refer Tender documents.
2 documents required · 2 mandatory
₹525
₹26,490
29 Feb 2024
8 Dec 2023
19 Dec 2023
8 Dec 2023
18 Dec 2023
8 Dec 2023
Amount
Wiring for light point / fan point /exhaust fan point /call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed steel conduit, with piano type switch, phenolic laminated sheet, suitable size MS box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc.as required - GROUP C.
Wiring for circuit / submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required - 2 X 2.5 sq.mm + 1 x 2.5 sq.mm earth.
Wiring for circuit / submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required - 4 X 4 sq.mm + 2 x 4 sq.mm earth wire.
Wiring for circuit / submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required - 4 X 6 sq.mm + 2 x 6 sq.mm earth wire.
Supplying and fixing following modular switch / socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required - 5/6 A switch.
Supplying and fixing following modular switch / socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required - 15/16 A switch.
Supplying and fixing following modular switch / socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required - 3 pin 5/6 A socket outlet.
Supplying and fixing following modular switch / socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required - 6 pin 15/16 A socket outlet.
Supplying and fixing two module stepped type electronic fan requlator on the existing modular plate switch box including connections but excluding modular plate etc as required.
Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc.as required - 3 module.
Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc.as required - 4 module.
Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc.as required - 6 module.
Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc.as required - 12 module.
Supplying and fixing 3 pin , 5 A ceiling rose on the existing junction box / wooden block including connection etc as required.
Installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length (upto 30 cm) with 1.5 sq.mm FRLS PVC insulated, copper conductor, single core cable etc as required.
Installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required - Upto 450 mm sweep.
Supplying and fixing following way , single pole and neutral, sheet steel, MCB disribution board, 240 V, on surface / recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required (But without MCB / RCCB / Isolator) - 8 way (4+24), double door
Supplying and fixing of following ways surface / recess mounting, vertical type, 415 V, TPN MCB distribuition board of sherrt steel, dust protected, duly powder painted, inlusive of 200 A tinned copper bus bar, common netural link, earth bar, din bar for mounting MCB'S (but without MCB,S (but without MCB's and incomer ) as required. (note : Vertical type MCB TPDB is normally usd where 3 phase utlets are required) - 4 way (4 + 12), double door.
Supplying and fixing 5 A to 32 A rating , 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. - Single Pole.
Supplying and fixing 5 A to 32 A rating , 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc . as required. - Single Pole and neutral.
Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc .as required. - Triple Pole.
Supplying and fixing following rating , four pole ,(three phase and neutral), 415 V, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required - 63 A.
Earthing with G.I. earth pipe 4.5 meter long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal / coke and salt as required.
Providing and fixing 4.00 mm dia copper wire on surface or in recess for loop earthing as required.
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 kV grade of following size direct in ground including excavation , sand cushioning, protective covering and refilling the trench etc.as required - Upto 35 sq.mm.
Supplying and making outdoor end termination with cast resin compound including aluminium lugs and other jointing materials for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 kV grade as required - 4 X 25 sq.mm.
Fixing testing and commissioning of Sodium vapour / Mercury vapour / Metal halide street light fittings on existing poles as required.
Supply and fixing of wall mount bracket of 50 mm dia GI pipe suitable for SVL / MH fittings with clamp, bolts and nuts as required.
Supply of 48W LED Street Light Fitting(Philips / Havells).
Supplying and fixing 4 feet, 20-24W system wattage LED tube light fitting with aluminium extruded heat sink and high efficiency polyearbonate diffuser suitable for surface mounting with on site warranty for three years. Make: Philips/ Wipro/ Hawells/ Crompton.
Supplying and ceiling fan sweep 1200mm Fushion - 50 Energy saving fan five star. Make: Havells.
Supplying of 10" exhaust fan Make: Havells.
Supplying and fixing of following size of modular surface PVC box for including cutting the wall and making good the same as in required Make: Legrand. 2 module
Supplying and fixing of modular PVC box for 3 module including cutting the wall and making good the same as required (Make: Legrand).
Supplying and fixing of modular PVC box for 6 module including cutting the wall and making good the same as required (Make: Legrand).
Supplying and fixing of following size of modular surface PVC box for including cutting the wall and making good the same as in required Make: Legrand. 4 module
Supplying and fixing of following size of modular surface PVC box for including cutting the wall and making good the same as in required Make: Legrand. 12 module
Supply of ISI marked 4x25sqmm armoured aluminium PVC U.G. cable 1.1 KV grade. Make: Finolex/ Polycab/ Havells.
Supplying and fixing L angle for Arial Board clamp.
Supplying and laying of D-Link CAT 6 networking cable.
Supplying and fixing of CAT 6 RJ 45 computer jack 1 modules.
Supplying and fixing Power manager.
Supplying and fixing cable manager.
Supplying and fixing D-Link 15U rack.
Instalation charges for Networking system including testing and commissioning.
Supply of 2 KVA Single phase sine wave tranceformer based home UPS with 7 hours back up for full load and 2 years warranty protection features for over load/ short circuit and battery current control with intelligent charger. (Make: 024EXIDEP020. The rate is inclusive of all taxes.
Supply of 12V 150AH Battery 4 years warranty. (Make: 6EL150L/EXIDE TUBULAR BATTERY). The rate is inclusive of all taxes.
Fabrication, supply, erection, testing and commissioning of one no. of distribution power supply of over all size 1600mm x 1000mm x 250mm made out of 16SWG thick CPC MS sheet. The panel has to be erected with 50mm X 50mm X 6mm angle ion channel fixed suitable on the wall with the height of 30 cm. The distribution panel has to be fitted with 2 Nos. of 160A TPN Cubical type Switch without SS enclosure excluding fuse link DIN Type (Make – Standard / C&S), 4nos. 63A TPN cubical type switch without SS enclosure excluding fuse link DIN type (Make – Standard / C&S), 3nos. of 200/5/ 600/5A current tranformer (0.5% precision) (Make: Legrand - Lexie), 1 no. of Digital Ammeter range (0-1200A) (Make: Siemens/ Legrand-Lexie) 1 no. of Digitial Voltmeter (0-500V) (Make: Siemens/ Legrand-Lexie) 3 nos. of signal lamp in various colours (Make: Siemens/ C&S/ L&T/ Teknic) the few switch units are to be fixed in the 10mm thick hylem sheet horizontally within the allotted size. The panel should contain cable raising chamber, busbar, three-phase indicator, Voltmeter, Ammeter are fixed in the hylem sheet with necessary indicator including fuse with aluminium busbar arrangement. The busbar chamber has to be provided with aluminium bus bar (250A) of 10 Meter length of size 25 X 6mm for phase and neutral and should be provided with insulator coloured shrinkable sleeves mounted on DMC supports for fixing it in position Interior connection between the switch fuse units are to be done with 25 Meter length of 10.0 sqmm ISI marked, FR PVC insulated, single core copper conductor cable of respective phase and neutral (Make – Finolex / Polycab). The wire should be provided with crimping type sockets and bolted to busbar with 6mm GI bolts and nuts with plates and spring washers for phase and neutral. All the doors should be of flush type and shall be detachable for individual switcher with inter locking in one position and 2nos. of 200mm* X 150mm M.V.danger notice plate are fixed in the front side door of the panel board. The door for one busbar and one cable ducts should also flush and shall be provided with removable type gland plated to the bottom and with sufficient holes of required diameter. The entire panel board and all accessories should be painted with two coats of Zinc chromate and two coats of anti corrosive epoxy shade 631 Siemens grey paint after completion of de-rusting process. The cost should be inclusive of minor modification suitable for site condition as approved by the Engineer-in-charge.
Supplying of Green LED Square RC 140B LED 29S - 6500 PSE WH - 36W.
Supply and fixing of 20 - 24W slim type recess mounted square LED luminaire of size 1'x1' / 1.25'x1.25' Make:Wipro/ Jaquar/ Philips.
Supplying and fixing D-Link 1 mt. patch cable.
Supplying and fixing D-Link patch panel Cat 6 port.
Supplying and fixing D-Link 24port switch 10/100/1000.
Supplying and fixing 10 - 60 Amp 3 Phase Energy metre make: HPL.
Supplying of 3 star rated wall mountable Split type 2.00 ton capacity Air conditioner unit as per IS 1391 part 2 with following specification. Material for body for indoor unit ABS. Normal cooling capacity (K.cal./Hr): 5000 - 5500 power consumption max (watts): 1400 - 1500 watts, Min room discharge Air flow (CFM/Hr): 550 - 600. Air conditioner shall be suitable for 230V 50hz operation and capable of performing the function as cooling, air circulating and filtering and confirm to IS: 10617 part EMPERIA split A/C unit Model: NX series. The rate is inclusive of all taxes.
Supply and fixing stablizer 5 KVA voltage stabilizer Make: Everest (double booster) Everest 4 KVA stablizer. The rate is inclusive of all taxes.
Supplying of Extra copper tubing
Installation charges for split type Air conditioner
Civil and angle works for indoor and outdoor units (including materials and labour charges)
perumal electricals
D RAMESH ELECTRICALS
G.KRISHNARAJ & CO
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .