Loading
Loading…
Loading…
Tender Value
Refer Docs
Closing Date
2 Dec 2021, 2:30 pmClosed
PR & CC
Public e bid in two bids system are invited for EV CHARGES and HCD NCZ as per terms of tender.The
21000077-HD-11120
21000077-HD-11120
Open Tender
Beed, Maharashtra
₹0
Exempted
2 Dec 2021
11 Nov 2021
2 Dec 2021
2 Dec 2021
11 Nov 2021 - 21 Nov 2021
| Item No | Item Title | Description | Qty | Unit |
|---|---|---|---|---|
| 1 | Supply-3KW EV charger | Supply-3KW EV charger — PART NAME:ELECTRICAL VEHICLE CHARGER; PART RATING:MINIMUM 3 KW; ADDITIONAL INFORMATION:NUMBER OF PHASE:1; AC INPUT:VOLTAGE RATING:1-PHASE, 200~240VAC (±15%), MAXIMUM INPUT CURRENT:16A, INPUT FREQUENCY:50 HZ ± 1.5HZ, USER AUTHENTICATION:RFID , QR-CODE SCAN, OCPP BASED MOBILE APP INTERFACE. BACKUP POWER:INPUT SUPPLY FAILURE BACKUP:BATTERY BACKUP FOR MINIMUM 1 HOUR FOR THE CONTROL SYSTEM AND BILLING UNIT. AC OUTPUT:NUMBER OF OUTPUT PORTS:1 NUMBER, OUTPUT CONNECTOR: IEC 60309, OUTPUT CURRENT:15 AMP, OUTPUT POWER:230VAC, 50 HZ, 3.3 KW. AC INPUT PROTECTION:AC VOLTAGE PROTECTION:AC OVER-VOLTAGE, AC UNDER-VOLTAGE, AC CURRENT PROTECTION:AC OVER CURRENT/SHORT CIRCUIT, AC SAFETY PROTECTIONS:RESIDUAL CURRENT/GROUND FAULT, EARTH PRESENCE/CONNECTION MONITORING, POLARITY REVERSE PROTECTION, SURGE PROTECTION 4 KV DM, OVER TEMPERATURE. ENERGY METERING:INDEPENDANT AC ENERGY METER FOR EACH OUTPUT:CLASS 1.0 ENERGY METER FOR EACH OUTPUT, OPERATING TEMPERATURE:-30 TO 55 DEG C. HUMIDITY:ENCLOSURE PROTECTION: <95% RELATIVE HUMIDITY, NON-CONDENSING, ENCLOSURE PROTECTION:IP55 OR BETTER, COOLING METHOD:NATURAL/FORCED:NATURAL/FAN COOLING, APPLICATION:TO CHARGE:E-AUTO, E-RIKSHAW, E-SCOOTERS, HAVING 1 OUTPUT | - | Each |
| 2 | Install&comm- 3KW EV charger | Install&comm- 3KW EV charger — INSTALLATION AND COMMISSIONING 3 KW EV CHARGER: INSTALLATION AND COMMISSIONING 1 PHASE MINIMUM 3 KW ELECTRIC VEHICLE CHARGER HAVING 1 OUTPUT. | - | Each |
| 3 | Supply-7KW EV charger | Supply-7KW EV charger — PART NAME:ELECTRICAL VEHICLE CHARGER; PART RATING:MINIMUM 7 KW; ADDITIONAL INFORMATION:NUMBER OF PHASE:1; AC INPUT:VOLTAGE RATING:1-PHASE, 200~240VAC (±15%), MAXIMUM INPUT CURRENT:32 A, INPUT FREQUENCY:50 HZ ± 1.5HZ, USER AUTHENTICATION:RFID, QR-CODE SCAN, OCPP BASED MOBILE APP INTERFACE. BACKUP POWER:INPUT SUPPLY FAILURE BACKUP:BATTERY BACKUP FOR MINIMUM 1 HOUR FOR THE CONTROL SYSTEM AND BILLING UNIT. AC OUTPUT:NUMBER OF OUTPUT PORTS:1 NUMBER, OUTPUT CONNECTOR:IEC 62196 TYPE-2 PLUG CABLE LENGTH-5 M MIN, OUTPUT CURRENT:32 AMP, OUTPUT POWER:230 VAC, 50 HZ, 7.2 KW. AC INPUT PROTECTION:AC VOLTAGE PROTECTION:AC OVER- VOLTAGE, AC UNDER-VOLTAGE, AC CURRENT PROTECTION:AC OVER CURRENT/SHORT CIRCUIT, AC SAFETY PROTECTIONS:RESIDUAL CURRENT/GROUND FAULT, EARTH PRESENCE/CONNECTION MONITORING, POLARITY REVERSE PROTECTION, SURGE PROTECTION 4 KV DM, OVER TEMPERATURE. ENERGY METERING:INDEPENDENT AC ENERGY METER FOR EACH OUTPUT:CLASS 1.0 ENERGY METER FOR EACH OUTPUT, OPERATING TEMPERATURE:-30 TO 55 DEG C. HUMIDITY:ENCLOSURE PROTECTION: <95% RELATIVE HUMIDITY, NON-CONDENSING, ENCLOSURE PROTECTION:IP55 OR BETTER, COOLING METHOD:NATURAL/FORCED:NATURAL/FAN COOLING, APPLICATION:TO CHARGE:LIGHT MOTOR VEHICLES, HAVING 1 OUTPUT | - | Each |
| 4 | Install&comm- 7KW EV charger | Install&comm- 7KW EV charger — INSTALLATION AND COMMISSIONING 7 KW EV CHARGER: INSTALLATION AND COMMISSIONING 1 PHASE MINIMUM 7 KW ELECTRIC VEHICLE CHARGER HAVING 1 OUTPUT. | - | Each |
| 5 | FIXED TYPE HYDROCARBON | FIXED TYPE HYDROCARBON — FIXED TYPE HYDROCARBON GAS DETECTOR SENSOR FOR HYDROGEN RANGE: 0-100% LEL | - | Each |
| 6 | INSTLN OF HYDROCARBON | INSTLN OF HYDROCARBON — INSTALLATION AND COMMISSIONING OF HYDROCARBON DETECTORS AT THE LOCATIONS SPECIFIED IN SCOPE OF JOB AND STC. | - | Each |
| 7 | Supply-3KW EV charger | Supply-3KW EV charger — PART NAME:ELECTRICAL VEHICLE CHARGER; PART RATING:MINIMUM 3 KW; ADDITIONAL INFORMATION:NUMBER OF PHASE:1; AC INPUT:VOLTAGE RATING:1-PHASE, 200~240VAC (±15%), MAXIMUM INPUT CURRENT:16A, INPUT FREQUENCY:50 HZ ± 1.5HZ, USER AUTHENTICATION:RFID , QR-CODE SCAN, OCPP BASED MOBILE APP INTERFACE. BACKUP POWER:INPUT SUPPLY FAILURE BACKUP:BATTERY BACKUP FOR MINIMUM 1 HOUR FOR THE CONTROL SYSTEM AND BILLING UNIT. AC OUTPUT:NUMBER OF OUTPUT PORTS:1 NUMBER, OUTPUT CONNECTOR: IEC 60309, OUTPUT CURRENT:15 AMP, OUTPUT POWER:230VAC, 50 HZ, 3.3 KW. AC INPUT PROTECTION:AC VOLTAGE PROTECTION:AC OVER-VOLTAGE, AC UNDER-VOLTAGE, AC CURRENT PROTECTION:AC OVER CURRENT/SHORT CIRCUIT, AC SAFETY PROTECTIONS:RESIDUAL CURRENT/GROUND FAULT, EARTH PRESENCE/CONNECTION MONITORING, POLARITY REVERSE PROTECTION, SURGE PROTECTION 4 KV DM, OVER TEMPERATURE. ENERGY METERING:INDEPENDANT AC ENERGY METER FOR EACH OUTPUT:CLASS 1.0 ENERGY METER FOR EACH OUTPUT, OPERATING TEMPERATURE:-30 TO 55 DEG C. HUMIDITY:ENCLOSURE PROTECTION: <95% RELATIVE HUMIDITY, NON-CONDENSING, ENCLOSURE PROTECTION:IP55 OR BETTER, COOLING METHOD:NATURAL/FORCED:NATURAL/FAN COOLING, APPLICATION:TO CHARGE:E-AUTO, E-RIKSHAW, E-SCOOTERS, HAVING 1 OUTPUT | - | Each |
| 8 | Install&comm- 3KW EV charger | Install&comm- 3KW EV charger — INSTALLATION AND COMMISSIONING 3 KW EV CHARGER: INSTALLATION AND COMMISSIONING 1 PHASE MINIMUM 3 KW ELECTRIC VEHICLE CHARGER HAVING 1 OUTPUT. | - | Each |
| 9 | Supply-7KW EV charger | Supply-7KW EV charger — PART NAME:ELECTRICAL VEHICLE CHARGER; PART RATING:MINIMUM 7 KW; ADDITIONAL INFORMATION:NUMBER OF PHASE:1; AC INPUT:VOLTAGE RATING:1-PHASE, 200~240VAC (±15%), MAXIMUM INPUT CURRENT:32 A, INPUT FREQUENCY:50 HZ ± 1.5HZ, USER AUTHENTICATION:RFID, QR-CODE SCAN, OCPP BASED MOBILE APP INTERFACE. BACKUP POWER:INPUT SUPPLY FAILURE BACKUP:BATTERY BACKUP FOR MINIMUM 1 HOUR FOR THE CONTROL SYSTEM AND BILLING UNIT. AC OUTPUT:NUMBER OF OUTPUT PORTS:1 NUMBER, OUTPUT CONNECTOR:IEC 62196 TYPE-2 PLUG CABLE LENGTH-5 M MIN, OUTPUT CURRENT:32 AMP, OUTPUT POWER:230 VAC, 50 HZ, 7.2 KW. AC INPUT PROTECTION:AC VOLTAGE PROTECTION:AC OVER- VOLTAGE, AC UNDER-VOLTAGE, AC CURRENT PROTECTION:AC OVER CURRENT/SHORT CIRCUIT, AC SAFETY PROTECTIONS:RESIDUAL CURRENT/GROUND FAULT, EARTH PRESENCE/CONNECTION MONITORING, POLARITY REVERSE PROTECTION, SURGE PROTECTION 4 KV DM, OVER TEMPERATURE. ENERGY METERING:INDEPENDENT AC ENERGY METER FOR EACH OUTPUT:CLASS 1.0 ENERGY METER FOR EACH OUTPUT, OPERATING TEMPERATURE:-30 TO 55 DEG C. HUMIDITY:ENCLOSURE PROTECTION: <95% RELATIVE HUMIDITY, NON-CONDENSING, ENCLOSURE PROTECTION:IP55 OR BETTER, COOLING METHOD:NATURAL/FORCED:NATURAL/FAN COOLING, APPLICATION:TO CHARGE:LIGHT MOTOR VEHICLES, HAVING 1 OUTPUT | - | Each |
| 10 | Install&comm- 7KW EV charger | Install&comm- 7KW EV charger — INSTALLATION AND COMMISSIONING 7 KW EV CHARGER: INSTALLATION AND COMMISSIONING 1 PHASE MINIMUM 7 KW ELECTRIC VEHICLE CHARGER HAVING 1 OUTPUT. | - | Each |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
RAW_HTML
21000077-HD-11120.pdf
TENDER_DOCUMENT • 11.86 MB
Download all tender documents and submit your bid