Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.4 CrAccepted-AOC SCF 15 HUDA COMPLEX 184 NEW IDC 124001 | ROHTAK | HARYANA | 124001 | ₹1.4 Cr | L1 | Accepted-AOC L1 |
| 2 | L2₹1.5 Cr+₹9.1 L (6.68%)Rejected-Finance | ₹1.5 Cr+₹9.1 L (6.68%) | L2 | Rejected-Finance L2 |
| 3 | Rejected-Technical 164 A 11 GALI NO 3 RISHI NAGAR KAITHAL 136027 | KAITHAL | HARYANA | 136027 | - | - | Rejected-Technical Undertaking for Profit and loss not attached |
Tender Value
₹1.1 Cr
EMD Value
₹2.1 L
Closing Date
21 Feb 2022, 5:00 pmClosed
R.Nagender Singh
XEN(E)
Upgradation of 100 to 200 Bedded Hospital at Narnaul in Distt. Mohindergarh (Pdg. 1000 and 630 KVA CSS only)
2022_HRY_205660_1
PWD/HRY/JAN-007
Open Tender
Electrical Works
Works
90 days
XEN(E)
Refer DNIT
2 documents required · 2 mandatory
₹15,000
₹2.1 L
6 Jan 2023
29 Jan 2022
22 Feb 2022
29 Jan 2022
21 Feb 2022
29 Jan 2022
Amount
Supply and erection of Medium Voltage caution notice plate of size 200*150 mm in three languages
Supply and erection of High Tension Voltage caution notice plate of size 250*200 mm in three languages.
Supply and erection of shock restoration chart in glass frame
Supply & Erection of mild steel bucket stand suitable for 6 Nos. fire buckets,(but without bucket) including the cost of welding and painting of complete stand will one coat of red oxide and 2 coats of approved paint of red colour with all labour and material required to complete the job in all respect up to the entire Satisfaction engineer in charge of the work (size 6'x4' made of GI pipe 32mm dia).
EARTHING AND LIGHTENING ARRESTOR Earthing with G.I. earth plate 600 mmx 600 mm x 6 mm thick including accessories and providing masonry enclosures with cover plate having locking arrangement and watering pipe etc. (but without charcoal or coke and salt) complete as required.
Earthing with tinned copper earth plate 600mmx600mmx3mm thick including accessories and providing masonry enclosures with cover plate having locking arrangement and watering pipe etc. (but without charcoal or coke and salt) etc. complete as required
Extra for charcoal or coke and salt for G. I. plate or copper plate earth electrode.
Supplying and laying 25mm x 3 mm G.I. strip in 40 mm dia,GI pipe as/from earth electrode including soldering etc. as required
Providing and fixing 25 mm x 3mm G.I. strip on surface or in recess for connections etc. as required with all labour and material
Providing and fixing 25 mm x5 mm copper strip in 40 mm dia G.I. pipe from earth electrode as required
Providing and fixing 25 mm x 5mm copper strip on surface or in recess for connections etc. as required with all labour and material.
LT CABLE Supply and erection of suitable compression type brass cable glands for underground Cable :- 70 sqmm to 95 sqmm Cable 3 to 3½ Core
240 sqmm to Cable 3 to 32 Core
300 sqmm to 400 sqmm Cable 3 to 3½ Core
Supply and erection of aluminium lugs heavy duty including crimping etc. up to the entire satisfaction of the Engineer-in-charge of the work 95 sqmm
MISCELLANEOUS ITEMS S/E mark double walled corrugated (DWC) HDPE, pipe 10 Kg/Cm2 ,laid 0.75 Metre below ground level including digging and refilling of earth including cost of suitable size socket/coupler for HOPE pipe including the cost of labour and material required to complete the job in all respect up to the entire satisfaction of Engineer in charge of the work DWC/HDPE pipe 63/50 mm outer dialinner dia
DWC/HDPE pipe 145/123 mm outer dial inner dia
The 11kV Outdoor Package Sub-Station shall be consisting of following , HT SWITCHGEAR 11kV 630Amps indoor type SF6 RMU 3way 21KA/3 sec. Non-Extensible Ring Main Unit Compact switchgear consisting of Two Number manual Load break Switches and One number Manual Vacuum Circuit Breaker in SF6 insulated stainless steel enclosure with series trip, self powered microprocessor based numerical over current and earth fault relay protection. Interconnection between HT Switchgear and primary of transformer shall be done through 1C x 3R x 120 sq.mm Aluminium Unarmoured XLPE cable (Make: ABB India Limited / Schneider Electric / Siemens/ C&S)Relay shall be of Ashida make of Model No: ADR 241S with communication port 1 No.Manometer 1 No.Fault passage indicator for incoming Load break switch only 1 No.Incoming and Outgoing Load break Switches suitable for Termination of 3C x 300 sq.mm AL cable only, Incoming Cable termination kits shall be in purchaser scope of supply only.TRANSFORMER 1000 KVA 11KV/433V Dyn11 Copper Wounded Cast Resin Dry Type Transformer with Off circuit /load tap links of +5% to -5% @2.5% with WTI scanner. Class of Insulation: H, Temperature rise limits 90 deg.C over an ambient of 40 degrees. Total Losses (Subject to IS Tol.) @100% -12KW and Total Losses (Subject to IS Tol.) @50% -4.50KW and Impedance of 5%(Subject to IS Tol.) with WTI scanner.(Make-Kirlosker / ABB) 1 No.Winding Temperature Indicator with 1 alarm and trip contact 1 No.Surge arrestor in the HV side 1 setLVS PANEL 1600AMPS Copper BUSBAR (100% FOR PHASES AND 50% FOR NEUTRAL) - CURRENT DENSITY OF Copper 1.4 A/sq.mm, LT panel made up of 1.5/2 mm thick CRCA sheet LT FROM TRANSFORMER1600 Amps 433V 4P 50Hz 50KA Fixed Manual Type Air Circuit Breaker (ACB) with Microprocessor based release for Overload , Shortcircuit and Earth Fault protection (Make: ABB/ C&S/ L&T) 1 No.RYB, ON/OFF Trip Indication 1 Set.Multifunction meter of class 1 accuracy (Make: Rishabh/Conserve/EL measure) 1 No.OUTDOOR ENCLOSURE Outdoor type enclosure having construction of Galvanised Sheet Steel having 2mm thickness for Load bearing member and 1.5mm thickness for Non Load bearing members with 4 mm base frame. The Enclosure shall have IP54 degree of protection for HT & LT switchgear compartment & IP23 degree of protection for Transformer compartment. The enclosure exterior shall be Powder Coated (colour Light Gray & D.A.Gray ). Each compartment will be provided with the door and pad locking arrangement. The Compartment illumination lamp with door operated switch shall be provided for MV & LV compartment. Enclosure Class shall be K10. CSS shall be a type tested design for Internal arc classification of IAC-AB of 21kA for 1 sec as per IEC 62271-202 1 Set INTERCONNECTION AND EARTHING Interconnection Between HT switchgear & Transformer using 1Cx3Rx 120Sq.mm XLPE Single core cable & Interconnection between Transformer & LT switchgear using Copper Busbars. Internal earthing connections including transformer neutral by using 50x6 mm GI Strips. 1 Set
The 11kV Outdoor Package Sub-Station shall be consisting of following , HT SWITCHGEAR 11kV 630Amps indoor type SF6 RMU 3way 21KA/3 sec. Non-Extensible Ring Main Unit Compact switchgear consisting of Two Number manual Load break Switches and One number Manual Vacuum Circuit Breaker in SF6 insulated stainless steel enclosure with series trip, self powered microprocessor based numerical over current and earth fault relay protection. Interconnection between HT Switchgear and primary of transformer shall be done through 1C x 3R x 120 sq.mm Aluminium Unarmoured XLPE cable (Make: ABB India Limited / Schneider Electric / Siemens/ C&S) Relay shall be of Ashida make of Model No: ADR 241S with communication port 1 No. Manometer 1 No.Fault passage indicator for incoming Load break switch only 1 No.Incoming and Outgoing Load break Switches suitable for Termination of 3C x 300 sq.mm AL cable only, Incoming Cable termination kits shall be in purchaser scope of supply only.TRANSFORMER630KVA 11KV/433V Dyn11 Copper Wounded Cast Resin Dry Type Transformer with Off circuit /load tap links of +5% to -5% @2.5% with WTI scanner. Class of Insulation: H, Temperature rise limits 90 deg.C over an ambient of 40 degrees. Total Losses (Subject to IS Tol.) @100% -8.82KW and Total Losses (Subject to IS Tol.) @50% -3.34KW and Impedance of 4.5%(Subject to IS Tol.) with WTI scanner.(Make-Kirlosker / ABB) 1 No.Winding Temperature Indicator with 1 alarm and trip contact 1 No.Surge arrestor in the HV side 1 setLVS PANEL 1000AMPS Copper BUSBAR (100% FOR PHASES AND 50% FOR NEUTRAL) - CURRENT DENSITY OF Copper 1.4 A/sq.mm, LT panel made up of 1.5/2 mm thick CRCA sheetLT FROM TRANSFORMER1000 Amps 433V 4P 50Hz 50KA Fixed Manual Type Air Circuit Breaker (ACB) with Microprocessor based release for Overload , Shortcircuit and Earth Fault protection (Make: ABB/ C&S/ L&T) 1 No.RYB, ON/OFF Trip Indication 1 Set.Multifunction meter of class 1 accuracy (Make: Rishabh/Conserve/EL measure) 1 No.OUTDOOR ENCLOSUREOutdoor type enclosure having construction of Galvanised Sheet Steel having 2mm thickness for Load bearing member and 1.5mm thickness for Non Load bearing members with 4 mm base frame. The Enclosure shall have IP54 degree of protection for HT & LT switchgear compartment & IP23 degree of protection for Transformer compartment. The enclosure exterior shall be Powder Coated (colour Light Gray & D.A.Gray ). Each compartment will be provided with the door and pad locking arrangement. The Compartment illumination lamp with door operated switch shall be provided for MV & LV compartment. Enclosure Class shall be K10. CSS shall be a type tested design for Internal arc classification of IAC-AB of 21kA for 1 sec as per IEC 62271-202 1 SetINTERCONNECTION AND EARTHINGInterconnection Between HT switchgear & Transformer using 1Cx3Rx 185Sq.mm XLPE Single core cable & Interconnection between Transformer & LT switchgear using Copper Busbars. Internal earthing connections including transformer neutral by using 50x6 mm GI Strips. 1 Set
Supply Erection testing & Commissioning of 11 KV indoor HT metering panel complete with C.Ts P. Ts. Cubical and electronic meter with accurancy class as per requirment/approved by DHBVN at he time of installation, consisting of the following. Cubical panel free standing floor mounting type made out of sheet steel 14 SWG CRCA sheet with chanel iron base frame spray painted with strong synthetic light grey enamel paint as per size and design approved by the DHBVN 3 Nos. 11 KV CTS of ratio as approved by DHBVN for indoor installation of appd. Make of 1 Nos. 11 KV PTs 11000/110 Volts Oil filled suitable for indoor installation of approved make of DHBVN. Digital Electronic Meter 3 phase 4 wires recording in KWH and rating and accuracy as by DHBVN with push button display operating system of different kind of readings. The cubical panel will be complete in all respect including intter connection, internal wiring with PVC copper cable, its testing and approval of all item by DHBVN including cost of all testing/ approval charges of all items of DHBVN including cost of all labour and material required to complete the job in all respect upto the entire satisfaction of the engineer in charge of the work.
Supply and erection of LT under ground cable, loose in existing pipe or trenches complete with necessary connections . 95 Sq. mm 3.5 Core Ard. Cable .
240 Sq. mm 3.5 Core Ard. Cable .
300 Sq. mm 3.5 Core Ard. Cable .
Supply and erection of HT 11KV XLPE under ground cable, loose in existing pipe or trenches complete with necessary connections . 120 Sq. mm 3 Core Ard. Cable .
Supply and erection of Outdoor type end termination jointing box heat shirnkable type suitable for 120 sqmm 3 core 11 K.H.V.T. XLPE cable with epoxy cast bushing including making necessary connection with all labour and material required to complete the job in all respect upto the entire satisfaction of the Engineer-in-charge of the work. Sutaible for 120 sqmm. 3 core XLPE cable
Supply and erection of Indoor type end termination jointing box heat shirnkable type suitable for 120 sqmm 3 core 11 K.H.V.T. XLPE cable with epoxy cast bushing including making necessary connection with all labour and material required to complete the job in all respect upto the entire satisfaction of the Engineer-in-charge of the work. Sutaible for 120 sqmm. 3 core XLPE cable
Supply and erection of fire bucket of G.I. sheet of 24 gauge write with " FIRE" as per fire specification.
Supply and erection of Rubber Mat 1mx2mmx 3mm thick suitable for 11/33 KVA as per IS No. 15652C/M/L 3017739 as per approved by Chief Electrical inspector, Govt. of Haryana.
Supply of Fire Extinguisher Make:Minimax Safex ABC Dry Powder Extinguisher 6kg Cap
Water/C2 Type extinguisher 9Ltr Cap
Supply & Erection of 11 meter pole complete the job in all respect upto the entire satisfaction of Engineer-in-Charge.
Supply & Erection of G.I. Half Clamps Wt. 1.47 kg. HVPN Drg. No. 2380 complete the job in all respect upto the entire satisfaction of Engineer-in-Charge.
Supply & Erection of G.I. Full Clamps Wt. 2.325 kg. HVPN Drg. No. 2349 complete the job in all respect upto the entire satisfaction of Engineer-in-Charge.
Supply & Erection of 11 KV pin insulator with pin complete the job in all respect upto the entire satisfaction of Engineer-in-Charge.
Supply & Erection of G.I. Channel 100x50x6mm 2200mm for H pole, wt. 21.100 kg complete the job in all respect upto the entire satisfaction of Engineer-in-Charge.
Supply & Erection of G.I. Angle iron 50x50x6mm 2400mm for earth wire, wt. 10.80 kg complete the job in all respect upto the entire satisfaction of Engineer-in-Charge.
Supply & Erection of 11 KV GO switch complete with handle, pipe & supporting channel complete the job in all respect upto the entire satisfaction of Engineer-in-Charge.
Supply & Erection of ACSR conductor 50mm2 (Rabbit) complete the job in all respect upto the entire satisfaction of Engineer-in-Charge.
Supply & Erection of G.I. nut & bolt off sizes complete the job in all respect upto the entire satisfaction of Engineer-in-Charge.
Supply & Erection of Lightning arrestor 11KV complete the job in all respect upto the entire satisfaction of Engineer-in-Charge.
Sh. Shyam Lal Contractor
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .