Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹31.4 LAccepted-AOC BUILDING NO FLAT NO 19 6TH CROSS ROAD SANJEEVINI NAGAR MUDALAPALYA BANGALORE 560072 | BANGALORE | BANGALORE | KARNATAKA | 560072 | L1 | Accepted-AOC Being L1 Bidder | |
| 2 | L2₹33.2 L+₹1.8 L (5.86%)Rejected-AOC | L2 | Rejected-AOC Not L1 Bidder | |
| 3 | L3₹33.9 L+₹2.5 L (8.02%)Rejected-AOC NEAR LIC OFFICE KALAIGNAR ARIVALAYAM SHOP ROOM NO7 GROUND FLOOR OF BACK SIDE PHOENIX BAY SRI VIJAYA PURAM 744101 | SRI VIJAYA PURAM | SOUTH ANDAMAN | ANDAMAN AND NICOBAR ISLANDS | 744101 | L3 | Rejected-AOC Not L1 Bidder | |
| 4 | L4₹36.5 L+₹5.1 L (16.1%)Rejected-AOC | L4 | Rejected-AOC Not L1 Bidder | |
| 5 | L5₹37.9 L+₹6.5 L (20.6%)Rejected-AOC 1 225 5 6 SADAR BAZAR DELHI CANTT 110010 | NEW DELHI | DELHI | 110010 | L5 | Rejected-AOC Not L1 Bidder |
Tender Value
₹45 L
EMD Value
₹90,000
Closing Date
2 Jan 2024, 6:00 pmClosed
GE U WATER SUPPLY DELHI CANTT 10
GE U WATER SUPPLY DELHI CANTT 10
PETTY REPAIR FOR ATTENDING DAY TO DAY EM EXTERNAL WATER SUPPLY COMPLAINTS AT KABUL LINE TIGRIS ROAD SANYAT LINE SUMRAN LINE AND ADJOINING AREA IN THE AREA OF AGE U WS NO II UNDER GE U WATER SUPPLY DELHI CANTT 10
2023_MES_631237_1
GE/WS/IFA-93/Token-51 of 2023-24
Open Tender
Civil Works
Item Rate
330 days
GE U WATER SUPPLY DELHI CANTT 10
Please refer Tender documents.
5 documents required · 5 mandatory
₹500
GE U WATER SUPPLY DELHI CANTT 10
₹90,000
Yes
2 Feb 2024
5 Dec 2023
4 Jan 2024
5 Dec 2023
2 Jan 2024
19 Dec 2023
Amount
Labour only for attending day to day external water supply complaints of all nature i.e. leakage in water supply pipe lines, fittings/fixtures, over flow of overhead tank, no water supply including write down the complaints in complaint register and depute labour for attanding complaint complete all as specified and as directed. (Note 1 :- Any material required for attending complaints for rectification shall be measured and paid separately under respective item herein after) (Note 2 :- Quoted rates includes following other aspects as srl No. 3 (i) to 3 (x) below).
Attending external Electric supply complaints of day to day maintenance of existing LT panels including connecting electrical accessories/spares of water supply installations, electric fittings with lights, short circuits in pump house including write down the complaints in complaint register and depute labour for attanding complaint complete all as specified and as directed.. (Note 1 :- Any material required for attending complaints for rectification shall be measured and paid separately under respective item herein after) (Note 2 :- Quoted rates includes following other aspects as srl No. 3 (i) to 3 (x) below).
Notes for item No. 1.00 & 2.00 (i) The complaints shall be attended and the defects shall be rectified by a team of expert and experienced electrician/plumber as applicable assisted with adequate numbers of helpers complete all as specified and as directed. Minimum requirements of skilled and unskilled workers for whole contract period are as under:- (a) One plumber or fitter with one helper. (b) One Electrician or fitter with one helper. (ii) Requirement of additional workers if required for rectification of any complaint (occationally) will be provided by contractor on urgent requirement basis as directed by EIC without any extra cost.
(iii) The complaints shall be attended and defect shall be rectified within 04 hrs commencing from date and time of notifying the complaint failing which a penalty @ Rs 250/- per complaint per day (08 hrs) shall be levied upon/imposed on the contractor and recovery shall be made from contractor's dues. Contractor shall appoint suitable staff for receive and register of complaints received in person/through telephone/mobile and issue and control contractors stores and workers will required to available within time daily at 0800 hrs to 2000 Hrs to receive and notify each complaint. Attendence register of workers daily basis will provided by contractor duly signed by JE E/M & Eng-in-Charge.
(iv) In case, after checking and attending the defect, it is not possible to rectify the defects within 08 hrs the facts shall be brought to the notice of Engineer-in -charge by the contractor /his rep . If Engineer -in-charge is satisfied with contractors view, no recovery will be made.
(v) While attending the complaint of water supply /Electric supply if earth work is required then the same shall be measured and paid seperately under respective item of Sch 'A' . However no extra payments shall be made for dewatering.
(vi) Cutting of GI pipe in position and threading is also deemed to be included in the job rate (Fitting and fixtures will be measured and paid separetely under respective item of Sch A.
(vii) All T & P including safety gears required for attending the complaints shall be provided by the contracor.
(viii) The elecrician shall always be in possession of all Electrician tools , LT Megger, Earth tester , Multimeter , Crimping tool, insulation tape, Hand gloves etc required at site.
(ix) Old retrived materials, will be deposited by contractor to store yard of AGE (U) Water Supply No II and necessary RV attached with RAR / Final bill mentioning ledger number & page number. (x) All the fitting /fixtures as mention below item No 3 to 14 and 17 to 18.05, 25, 27 to 32 of BOQ shall be procured by contractor in one time and the same shall be kept with safe custory of Eng-in-charge store and issue RV to contractor. Piecmeal requirement of fixing of fittings as required at site will be issued by JE (E/M) through Baby indent. Proper register will maintained by contractor for consumption of materials at site with showing debit complaint wise. The same register will not signed by JE (E/M) & Eng-in-Charge and produced with RAR/Final bill. (xi) First RAR will be submitted by contractor for material lying at site only.
Supply only of the following items required to complete the complaint work :-
PTMT stop cock 15 mm dia
PTMT stop cock 20 mm dia
PTMT stop cock 25 mm dia
Tank nipple 20 mm dia
Tank nipple 25 mm dia
Supply only GI Socket 'Medium' grade ISI Marked complete all as specified and as directed of following sizes : -
15 mm bore
20 mm bore
25 mm bore
40 mm bore
50mm bore
Supply only GI Elbow 'Medium grade', ISI Marked complete all as specified and as directed of following sizes : -
15 mm bore
20 mm bore
25 mm bore
40 mm bore
50 mm bore
Supply only GI Union 'Medium Grade' ISI Marked complete all as specified and as directed of following sizes : -
15 mm bore
20 mm bore
25 mm bore
40mm bore
50mm bore
Supply only GI Nipple of different length as per requirement, both end screwed 'Medium Grade', ISI marked of following sizes:-
15 mm bore
20 mm bore
25 mm bore
40 mm bore
50 mm bore
Supply only GI Reducing socket 'Medium grade' ISI marked, complete all as specified and directed of the following sizes :-
25 mmx15mm bore
20mmx15mm bore
25 mm x 20 mm bore
25 mmx 32mm bore
40 mmx 32mm bore
50 mmx 40mm bore
40mmx 20mm bore
40 mm x25mm bore
50 mm x25mm bore
Supply only GI Tee 'Medium grade' ISI marked, complete all as specified and directed of the following sizes :-
15mm x15mm x15mm
20 mm x 20 mm x 15 mm
20 mm x 20 mm x 20 mm
25 mm x 25 mm x 25 mm
25 mm x 25 mm x 15 mm
25 mm x 25 mm x 20 mm
32mm x 32mm x 32mm
40 mm x 40 mm x 40 mm
40 mm x 40 mm x 20 mm
40 mm x 40 mm x 25 mm
50 mm x 50 mm x 50 mm
50 mm x 50 mm x 40 mm
50 mm x 50 mm x 25 mm
51 mm x 50 mm x 20 mm
Supply only GI solid plug heavy duty ISI marked complete all as specified and directed of following sizes :-
15mm bore
20 mm bore
25 mm bore
32 mm bore
40 mm bore
50 mm bore
Supply only Lead pig bar of best quality complete all as specified.
Supply only spun yarn of best quality complete all as specified.
Supply only Nuts, Bolts and Washers 25 to 150 mm long of 6 to 20 mm dia complete all as specified and directed.
Supply only 3mm thick rubber gasket best quality complete all as specified and directed.
Supply & Fixing in replacement rotational moulded Poly-ethylene ISI water storage tanks (cylindrical vertical with closed top) of cap 500 Ltrs three layered hoisted and fixed in position at pump house building top complete all as specified.
Supply & Fixing in replacement rotational moulded Poly-ethylene ISI water storage tanks (cylindrical vertical with closed top) of cap 1000 Ltrs three layered hoisted and fixed in position at pump house building top complete all as specified. (Note for Ser Item No 16 & 17 : Old U/s material obtained from demolition shall be taken on charge in demolition/salvage register and enter page number in demolition statement. Necessary RV of PVC Tank in (EACH) shall be taken into account and attach with RAR/F Bill)
Supply only PTMT float valve with epoxy coated aluminium rod and high density plastic ball for following size omplete all as specified and directed by Engineer-in-Charge:-
15mm bore
20 mm bore
25 mm bore
40 mm bore
50 mm bore
Supply only gun metal gate valve with iron wheel head screwed both ends for iron pipe, ISI marked, as per IS : 778 of following sizes complete all as specified and directed by Engineer-in-charge :-
15mm bore
20 mm bore
25 mm bore
40 mm bore
50 mm bore
Testing of drinking water collected from local source (bore wells /shallow wells in the area of AGE(U) W/S No.II) and submission of detailed test report to the office of Engineer-in-Charge. (i) Carrying out minimum essential testing of water as per IS 10500-2012 mandatory for chemical colour, odour, taste, turbidity, pH value, TDS total hardness, iron, chloride, fluoride and residual free chlorine and Bacteriological total coliform organisms per 100 ml (MPN) and E Coli in 100 ml) with specific recommendation regarding suitability of water for drinking purposes. (ii) Collection of water from different sources of water ie. UG Sump, bore wells & shallow well in a sterilized bottle and testing in NABL Approved laboratory as mentioned in specification. (iii) Contractor will required to produce 'Test report' duly passed by Eng-in-charge during payment in RAR. No payment will be made without production of passed test report of approved lab.
Note 1:- Rate Quoted shall also deemed to be included for the followings:- (i) Cost of sterilized bottle as required. (ii) To and FRO transportation charges for collection of samples from source (UG sump, bore & shallow wells) Note 2:- Test reports so collected will be submitted to the Engr-in-Charge every month and failing to which attaract a penality of ₹5000/- per report and will be recovered from his RARs/Bills
Excvation in trenches not exc. 1.5 mtr wide and not exc 1.5 mtr deep for pipe line in soft/loose soil, getting out and levelling of bottom surface to required complete all as specified and as directed by Engineer-in-charge.
Returning filling, including spreading, levelling, watering and well ramming in layers not exc 25 cm thick all as specified and as directed by the Engineer-in-charge.
Removing excavated material from site to a distance not exc 50 m away and depositing where directed not exc 1.5 meters above the starting point all as directed by Engineer-in-charge.
Boring holes under road pavement by bocky manually or mechanically in any type of soil upto 200 mm bore in depth as per site requirement and Complete all as specified and directed by Engineer-in-Charge.
Surface dressing of uneven surfaces of the natural ground, rough excavated surfaces and filled area where ordered shall be trimed to an even surface horizontal or slopping, by removing vegetation and by scrapping high patches and filling low patches with the scrapping soil to given an even and neat look to the site. depth of cutting not exceeding 15 cm. complete all as specified and directed by Engineer-in-Charge.
Supply only 15 mm bore Bib tap standard of PTMT any colour high pressure screwed for male/ female treaded, for UPVC pipe/GI pipe of size 15mm bore complete all as specified and directed
Labour work required for taking out suction pipe 80 mm to 200 mm bore from sump of any capacity, dismantling of foot valve screwed / flanged type, and relowering after refixing in position the same duly cleaned / minor repair if any required such as replacement of rubber gasket/ lifting bolts & nuts including making thread for the suction pipes off sizes etc complete all as required and as directed by Engineer-in-Charge.
Supply only 'stem' made out from SS (all as per sample) of sluice valve of size as under : -
80 mm bore
100 mm bore
150 mm bore
200 mm bore
Supply only 'stem nut' made out from stainless steel suitable to match with existing sluice valve of sizes as under : -
80 mm bore
100 mm bore
150 mm bore
200 mm bore
Supply only 'gland plate' made out CI, suitable to match with existing sluice valve of sizes as under : -
80 mm bore
100 mm bore
150 mm bore
200 mm bore
Taking up or down steel tubing with connection including cleaning for removal all as specified and as directed by Engineer-in-Charge of the follwing sizes :- (Note:- Old U/s material obtained from demolition shall be taken on charge in demolition/salvage register and enter page number in demolition statement. Necessary RV of weight in (KG) shall be taken into account and attach with RAR/F Bill)
15 mm dia
20 mm dia
25 mm dia
40 mm dia
50 mm dia
80 mm dia
Relaying/refixing only jointing and testing of old GI pipes with new fittings i.e. Tee, elbow, socket & bend etc complete including cleaning completely in trenches/walls/floors as directed for the following sizes :- (Note :- Old GI Pipe obtained from item No 31 above shall be reused under this item).
15 mm dia
20 mm dia
25 mm dia
40 mm dia
50 mm dia
80 mm dia
Supply & fixing of GI pipe 'Medium grade' ISI marked including all fittings in old/new position as in walls/trenches and ceilling all as directed of following sizes :-
15 mm dia
20 mm dia
25 mm dia
40 mm dia
50 mm dia
80 mm dia
Supply & fixing of DI fitting for flanged /spigot and socketed pipes such as bends, reducer, tee pieces, tail pieces, collar, cross, caps & plug upto 150mm bore complete all as specifie and directed.
Supply & fixing of CI fittings/specials such as Tees, bends (any type, radius and angle) tapers any type, collars, tail pieces, caps and plugs of upto 150 mm bore dia size confirming to IS: 1538-1993 complete all as specified and directed. (Note for ser Item No 34 & 35 :Old U/s material obtained from demolition shall be taken on charge in demolition/salvage register and enter page number in demolition statement. Necessary RV of weight in (KG) shall be taken into account and attach with RAR/F Bill).
Taking up CI or DI pipe water mains including all fitings with spigot and socket ends and lead joint including burning out joints and removing lead of following sizes complete all as specified and directed (Note :- (i) Excavation & earth work shall be measured and paid under respective items) (ii) Old U/s material obtained from demolition shall be taken on charge in demolition/salvage register and enter page number in demolition statement. Necessary RV of (RM) shall be taken into account and attach with RAR/F Bill).
80 mm bore
100 mm bore
150 mm bore
200 mm bore
Relaying/refixing of pipe CI / DI pipes after cleaning from inside with suitable chemical and rodding all as directed by Engineer -in-charge of following sizes:- (Note:- Serviceable CI/DI pipes obtained from taking down under item No 36 shall be used.)
80 mm bore
100 mm bore
150 mm bore
200 mm bore
Supplying, laying, jointing, testing and commissioning of DI pipe as per IS 8239 class K-7 with in side cement mortar lining with spigot and socketed end laid in trenches complete with including rubber gasket joint all as specified and as directed at site for the following sizes:- Note :- (i) Excavation and earth work shall be measured and paid seperately under respective items of Sch 'A'. (ii) Layout of pipe line to be laid at site shall be given by Engineer-in-Charge as per requirement in piece meal but contractor will required to procure full quantity of DI pipe in one time after approval of make by GE. 1st RAR will be paid for material 'lying at site' only/piece meal procurement of DI pipe will not be accepted by department. Contractor will required to produce manufacture's test certificate, original purchase voucher & e-way bill alongwith 1ST RAR for payment of DI pipe in material lying at site.
80 mm bore
100 mm bore
150 mm bore
200 mm bore
Supply & fixing, testing & Commissioning of CI sluice valves of following sizes class PN 1.0 ISI mark flanged ends drilled having stainless steel spindle with cast iron wheel at top complete with including nut and bolts washers and rubber gasket, taking down old unsv sluice valve complete all as specified and as directed. (Note : Old U/s material obtained from demolition shall be taken on charge in demolition/salvage register and enter page number in demolition statement. Necessary RV of weight in (KG) shall be taken into account and attach with RAR/F Bill).
50 mm bore
80 mm bore
100 mm bore
150 mm bore
200 mm bore
250 mm bore
300 mm bore
Material and labour PCC (1:3:6) type C-2 (using 40 mm graded crushed stone aggregate) as in foundation of brick pillar to support the pipe line including demolition of old PCC and removing the debris from site complete all as specified and as directed at site by the Engr-in-Charge.
Material and labour Brick work with sub class 'B' bricks straight or curved on plan exc. 6M mean radius built in CM (1:4) as in brick pillar of required size and shape to support the pipe line including demolition of old brickwork & removing from site all as specified and as directed at site by the Engr-in-Charge. (Note : Old U/s material obtained from demolition shall be taken on charge in demolition/salvage register and enter page number in demolition statement. Necessary RV of weight in (KG) shall be taken into account and attach with RAR/F Bill).
Supply and filling of Multipurpose Grease lubricant oil for Motors & Pumps
Supply, fixing, jointing & testing in replacement butterfly valve (wafer type) of sizes as under, ISI Marked, flanged ends drilled pressure rating PN-1.0, PD Short body, inserting new one complete all as specified and as directed at site by the Engr-in-Charge. (Note : Old U/s material obtained from demolition shall be taken on charge in demolition/salvage register and enter page number in demolition statement. Necessary RV of weight in (KG) shall be taken into account and attach with RAR/F Bill).
100mm bore
150 mm bore
200 mm bore
300 mm bore
Supply, installation and testing flanged ends strainer/dirt box of following sizes with stainless steel mesh suitable for cold water meter to avoid foreign material entering into meter and making good connection with flanged ends, with gasket rubber sheet and nut & bolts fixing in horizontal/inclind/ vertical position, including taking out unsv strainer/dirt box complete all as directed at site by the Engr-in-Charge. Note :- (ii) Flange joints including jointing materials shall deemed to be included in the unit rate of this item. (ii) Old U/s material obtained from demolition shall be taken on charge in demolition/salvage register and enter page number in demolition statement. Necessary RV of weight in (KG) shall be taken into account and attach with RAR/F Bill.
50mm bore
80 mm bore
100 mm bore
150 mm bore
Supply, installation and testing of flanged ends water meter ISI marked woltman type, Class 'B' of following sizes and making good connection with flanged ends, with gasket rubber sheet and nut & bolts fixing in horizontal/inclind/vertical position, including taking out unsv water meter complete all as specified and directed at site by the Engr-in-Charge. Note :- (i) Flange joints including jointing materials shall deemed to be included in the unit rate of this item. (ii) Old U/s material obtained from demolition shall be taken on charge in demolition/salvage register and enter page number in demolition statement. Necessary RV of weight in (KG) shall be taken into account and attach with RAR/F Bill.
50mm bore
80 mm bore
100 mm bore
150 mm bore
200 mm bore
Supply and fixing CI foot valve flanged ends, swing type opration with rubber sheet, as per IS:4038 including taking out unsv foot valve all as specified and directed by Engr-in-Charge. Note:- (i) Flanged joints complete with jointing material shall deemed to be included in the unit rate of this item. (ii) Old U/s material obtained from demolition shall be taken on charge in demolition/salvage register and enter page number in demolition statement. Necessary RV of weight in (KG) shall be taken into account and attach with RAR/F Bill.
100mm bore
150 mm bore
Supply, fixing, jointing and testing of Cast iron Non Return valve without by pass arrangement, swing type, confirming to IS 5312, flanged ends pressure rating PN 1.0 complete including taking out unsv NRVcomplete all as specified and as directed at site by the Engr-in-Charge. Note:- (i) Flanged joints complete with jointing material shall deemed to be included in the unit rate of this item. (ii) Old U/s material obtained from demolition shall be taken on charge in demolition/salvage register and enter page number in demolition statement. Necessary RV of weight in (KG) shall be taken into account and attach with RAR/F Bill.
50 mm bore
80 mm bore
100 mm bore
150 mm bore
200 mm bore
Supplying, laying, jointing, welding & testing MS Pipe (Heavy duty class 'C') 8mm thick laid in trenches or on floors for connections to centrifugal pump sets for suction, pump to header and to connect out going water main CI/DI pipe line including taking down old unsv MS Pipe all as directed by Engr-in-Charge. Note:- (i) MS Flanges and Flange joints complete with jointing materials shall be measured and paid separately. (Note :- Old U/s material obtained from demolition shall be taken on charge in demolition/salvage register and enter page number in demolition statement. Necessary RV in weight (KG) shall be taken into account and attach with RAR/Final bill).
80 mm bore
100 mm bore
150 mm bore
200mm bore
250mm bore
M&L 15mm thick cement plaster on fair faces of brick work or concrete surfaces in cement plaster 1:4 including two coat of cement base paint after preparation of newly plastered surface of wall complete all as specified and directed.
ENVIRO TECH SERVICES
RK TRADERS
SREE BABA TRADERS
M P TYAGI ENGINEERS AND CONTRACTORS
Haryana EngineerService
Deven Associates
DHAIRYAE ENTERPRISES
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .