Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹4.0 CrAccepted-AOC CHAS ROAD JAINA MORE JARIDIH BOKARO JHARKHAND | BOKARO | JHARKHAND | 825102 | ₹4.0 Cr Quoted ₹4.1 Cr | L1 | Accepted-AOC ok |
| 2 | L2₹4.2 CrRejected-AOC BOKARO | BOKARO | JHARKHAND | 825102 | ₹4.2 Cr | L2 | Rejected-AOC ok |
| 3 | Rejected-Technical NEAR SEWADHAM DEOGHAR | DEOGHAR | JHARKHAND | 814112 | - | - | Rejected-Technical Not Qualified |
| 4 | Rejected-Technical BHULI NAGAR OLD B TYPE BHULI DHANBAD | - | - | Rejected-Technical Not Qualified |
| 5 | Rejected-Technical | - | - | Rejected-Technical Not Qualified |
Tender Value
₹3.9 Cr
EMD Value
₹7.9 L
Closing Date
11 Feb 2026, 5:00 pmClosed
Executive Engineer, R.D.Spl.Div. Bokaro
O/o Executive Engineer, R.D.Spl.Div. Bokaro 1st floor, working womens hostel, Camp-II, B.S. City, Bokaro-827001
Construction of Bridge across Garga river between Tetulia Mauja and NH-23 Bari Co-Operative more beside old Bridge in Chas Block of Bokaro district
2026_RDSPL_109865_1
RDD/SD/BOKARO/53/2024-25/4TH CALL
Open Tender
Civil Works - Bridges
540 days
Bari Co-Operative
Please refer Tender Documents
3 documents required · 3 mandatory
₹10,000
₹7.9 L
17 Jun 2026
28 Jan 2026
13 Feb 2026
28 Jan 2026
11 Feb 2026
28 Jan 2026
Laying and Jointing PVC Pipe. Heading
CONSTRUCTION OF BRIDGE Excavation for structures (Earth work in excavation of foundation of structures as per drawing and technical specification, including setting out, construction of shoring and bracing, removal of stumps and other deleterious matter, dressing of sides and bottom and backfilling with approved material.) i) Ordinary Soil (Excavation upto 3.0m depth)
ii) Ordinary Soil (Excavation 3m to 6m depth)
i) Ordinary rock (not requiring blasting)
PCC 1:3:6 in Foundation (Plain cement concrete 1:3:6 nominal mix in foundation with crushed stone aggregate 40 mm nominal size mechanically mixed, placed in foundation and compacted by vibration including curing for 14 days.)
Plain/Reinforced cement concrete (RCC Grade M30 using batching plant, transit mixer & Concrete Pump) in open foundation complete as per drawing and technical specifications
Filling Annular Space Around Footing in Rock. (Plain cement concrete 1:3:6 nominal mix in foundation with crushed stone aggregate 40 mm nominal size mechanically mixed, placed in foundation and compacted by vibration including curing for 14 days.)
Supplying, fiiting and placing un-coated HYSD bar reinforcement in foundation complete as per drawing and technical specifications.
Plain/Reinforced cement concrete (RCC Grade M30 using batching plant, transit mixer & concrete pump) in substructure complete as per drawing and technical specifications. (Height upto 5m)
Plain/Reinforced cement concrete (RCC Grade M30 using batching plant, transit mixer & concrete pump) in substructure complete as per drawing and technical specifications.(Height 5m to 10m)
Supplying, fiiting and placing HYSD bar reinforcement in sub-structure complete as per drawing and technical specification.
Providing weep holes in Brick masonry/Plain/Reinforced concrete abutment, wing wall/return wall with 100 mm dia AC pipe, extending through the full width of the structures with slope of 1V:20H towards drawing face. Complete as per drawing and Technical specifications.
Providing and laying of filter media with granular materials/tone crushed aggregates satisfying the requirements laid down in clause 2504.2.2 of MoRT&H specifications to a thickness of not less than 600mm with smaller size towards the soil and bigger size towards the wall and provided over the entire surface behind abutment, wing wall and return wall to the full height compacted to a firm condition complete as per drawing and technical specification.
Back filling behind abutment, wing wall and return wall (with Sandy Material) complete as per drawing and Technical specification
Furnishing and placing Reinforced/Prestressed cement concrete (RCC Grade M30) in super-structure (for solid slab) as per drawing and Technical Specification.
Supplying, fiiting and placing HYSD bar reinforcement in super-structure complete as per drawing and technical specification.
Providing and laying cement concrete wearing coat M-30 grade including reinforcement complete as per drawing and Techncial Specifications.
Construction of RCC railing of M30 Grade in-situ with 20 mm nominal size aggregate, true to line and grade, tolerance to vertical RCC post not to exceed 1 in 500, centre to centre spacing between vertical post not to exceed 2000 mm, leaving adequate space between vertical post for expansion, complete as per approved drawings and technical specifications.
Drainage Spouts complete as per Drawing and Technical Specification.
PCC M15 Grade leveling course below approach slab complete as per drawing and Technical Specification.
Reinforced cement concrete in approach slab including reinforcement and formwork complete as per drawing and Technical specification. (RCC M30)
Filler Joint Providing & fixing 2 mm thick corrugated copper plate in expansion joint complete as per drawing & Technical Specification.
Providing & fixing 20 mm thick compressible fibre board in expansion joint complete as per drawing & Technical Specification.
Providing and fixing in position 20 mm thick premoulded joint filler in expansion joint for fixed ends of simply supported spans not exceeding 10 m to cater for a horizontal movement upto 20 mm, covered with sealant complete as per drawing and technical specifications.
Providing and filling joint sealing compound as per drawings and technical specifications with coarse sand and 6% bitumen by weight
Excavation for structures (Earth work in excavation of foundation of structures as per drawing and technical specification, including setting out, construction of shoring and bracing, removal of stumps and other deleterious matter, dressing of sides and bottom and backfilling with approved material.)
Plain/Reinforced cement concrete (PCC Grade M15 using batching plant & Concrete pump) in open foundation complete as per drawing and technical specifications
Providing and laying Filer mateial underneath pitching in slopes complete as per drawing and technical specification
Providing and laying Pitching on slopes laid over prepared filter media including boulder apron laid dry in front of toe of embankment complete as per drawing and Technical specifications. (Stone/Boulder)
CONSTRUCTION OF APPROACH ROAD Excavation in Soil with Dozer with lead upto 100 metres (Excavation for road way in soil by mechanical means including cutting and pushing the earth to site of embankment upto a distance of 1000 metres (average lead 50 metres), including trimming bottom and side slopes in accordance with requirements of lines, grades and corss sections.)
Embankment Construction with Material Obtained from Borrow Pits (Construction of embankment with approved material obtained from borrow pits with all lifts and leads, transporting to site, spreading, grading to required slope and compacting to meet requirement of table 300-2)
Compacting original ground supporting embankment (Loosening of the ground upto a level of 500 mm below the subgrade level, watered, graded and compacted in layers to meet requirement of table 300-2 for subgrade construction.)
Granular Sub-Base with Graded Material (Shoulder) with Close Graded Material Gr-I (By Mix in Place Method) Construction of granular sub-base by providing close graded Material, mixing in a mechanical mix plant at OMC, carriage of mixed Material to work site, spreading in uniform layers with motor grader on prepared surface and compacting with vibratory power roller to achieve the desired density, complete as per clause 401.
Granular Sub-Base (Carriageway) with Coarse Graded Material Gr-I Construction of granular sub-base by providing close graded Material, mixing in a mechanical mix plant at OMC, carriage of mixed Material to work site, spreading in uniform layers with motor grader on prepared surface and compacting with vibratory power roller to achieve the desired density, complete as per clause 401.
Wet Mix Macadam (Plant Mix Method) Providing, laying, spreading and compacting graded stone aggregate to wet mix macadam specification including premixing the Material with water at OMC in mechanical mix plant carriage of mixed Material by tipper to site, laying in uniform layers with grader in sub- base / base course on well prepared surface and compacting with vibratory roller to achieve the desired density.
Prime coat over WMM/WBM (Providing and applying primer coat with bituminen emulsionon on the prepared surface of granular Base including clearing of road surface and spraying primer at the rate of 0.7kg/sqm using mechanical means)
Tack coat on Bituminus surfaces (Providing and applying tack coat with bitumen emulsion on pressure distributor at the rate of 0.2kg/sqm on the prepared surface of bituminous/granular Base cleaned with mechanical broom).
Open graded Premix surfacing (Providing, laying and rolling of open-graded pemix surfacing of 20mm thickness composed of 13.2mm to 5.6mm aggregates using viscosity grade bitumen to required line, grade and level to serve as wearing course on a previously prepared base, including mixing in a suitable hot mix plant of appropriate capcity not less than 200 tonnes/hour, laying and rolling with a smooth wheeled roller finished to required level and grades.)
Seal Coat (Providing and laying of premix sand seal coat with HMP of appropriate capacity not less than 200 tonnes/hours using crushed stone chipping 6.7mm size and penetration bitumen of suitable grade. (Case-II : Type B)
Reinforced cement concrete M15 grade boundary pillars of standard design as per IRC:25-1967, fixed in position including finishing and lettering but excluding painting. (2x2x25 Nos. = 100 Nos.)
CONSTRUCTION OF RCC RETAINING WALL Earth work in excavation of foundation ( Depth upto 3 m ) of structures as per drawing and technical specification, including setting out, construction of shoring and bracing, removal of stumps and other deleterious matter, dressing of sides and bottom and backfilling with approved material.
PCC 1:3:6 in Foundation (Plain cement concrete 1:3:6 nominal mix in foundation with crushed stone aggregate 40 mm nominal size mechanically mixed, placed in foundation and compacted by vibration including curing for 14 days.)
Reinforced cement concrete (RCC Grade M25 using batching plant transit mixture & concrete pump) in open foundation complete as per drawing and technical specifications.
Reinforced cement concrete (RCC Grade M25, height upto 5m) in substructure complete as per drawing and technical specifications. (Stem)
Supplying, fiiting and placing un-coated HYSD bar reinforcement in foundation complete as per drawing and technical specifications.
Supplying, fiiting and placing HYSD bar reinforcement in sub-structure complete as per drawing and technical specification.
Providing weep holes in Brick masonry/Plain/Reinforced concrete abutment, wing wall/return all with 100 mm dia AC pipe, extending through the full width of the structures with slope of 1V:20H towards drawing foce. Complete as per drawing and Technical specifications.
CONSTRUCTION OF GUARD WALL Earth work in excavation of foundation ( Depth upto 3 m ) of structures as per drawing and technical specification, including setting out, construction of shoring and bracing, removal of stumps and other deleterious matter, dressing of sides and bottom and backfilling with approved material.
PCC 1:3:6 in Foundation (Plain cement concrete 1:3:6 nominal mix in foundation with crushed stone aggregate 40 mm nominal size mechanically mixed, placed in foundation and compacted by vibration including curing for 14 days.).
Random rubble stone masonry work in cement mortar 1:3 in foundation complete as drawing and Technical Specification.
Random rubble stone masonry work in cement mortar 1:3 in substructure complete as drawing and Technical Specification.
Furnishing and Placing Reinforced/Prestressed cement concrete (PCC Grade M20) in super-structure (coping) as per drawing and Technical Specification
Pointing with cement mortar (1:3) on stone work as per Technical specifications.
Providing weep holes in Brick masonry/Plain/Reinforced concrete abutment, wing wall/return all with 100 mm dia AC pipe, extending through the full width of the structures with slope of 1V:20H towards drawing foce. Complete as per drawing and Technical specifications.
DISMANTLING Dismantling of Structures (Dismantling of existing structures like culverts, bridges, retaining walls and other structure comprising of masonry, cement concrete, wood work, steel work, including T&P and scaffoling wherever necessary, sorting the dismantled material, disposal of unserviceable material and stacking the serviceable material with all lifts of 1000 metres)
Dismantling Brick/ Tile work/ rubble masonary/pitching etc. (By Mechanical Means)
Removing all type of hume pipes and stacking within a lead of 1000 metres including earthwork and dismantling of masonry works. Above 600 mm to 900 mm dia
CARRIAGE OF MATERIALS Cement, Bokaro 10 Km.(P) + 0 Km (K) .
Steel, Bokaro 10 Km.(P) + 0 Km (K) .
Sand, Damodar 40 Km.(P) + 0 Km (K) .
Chips, Jaina More 15 Km.(P) + 0 Km (K) .
Boulder, Jaina More 15 Km.(P) + 0 Km (K) .
Aggregate, Jaina More 15 Km.(P) + 0 Km (K) .
Bitumen , Bokaro 13 Km.(P) + 0 Km (K) .
Add. 18% GST
Add. 1% Labour Cess
Please Enable Macros to View BoQ information
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.34 MB
SBD.pdf
Tender Documents • 1.55 MB
BOQ_148443.xls
BOQ • 0.30 MB
Download all tender documents and submit your bid