| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1st₹41.8 LAccepted-AOC RH NO 06 KARMA KSHETRA HOUSING SOCIETY SECTOR 29 PRADHIKARAN RAVET POST DEHU ROAD 412 101 | NA | NA | 412101 | ₹41.8 L Quoted ₹43.2 L | 1st | Accepted-AOC The M/s Shri Sai Electricals is L1 bidder being accepted |
| 2 | 2nd₹44.3 LRejected-Finance | ₹44.3 L | 2nd | Rejected-Finance Not being L1 |
| 3 | 3rd₹45.8 LRejected-Finance 0001D ATM HOUSE AIR FORCE NEENA THAPA GORAKHPUR UTTAR PRADESH 273008 UDYAM UP 32 0054752 | GORAKHPUR | UTTAR PRADESH | 273008 | ₹45.8 L | 3rd | Rejected-Finance Not being L1 |
| 4 | 4th₹55.4 LRejected-Finance | ₹55.4 L | 4th | Rejected-Finance Not being L1 |
| 5 | 5th₹57.8 LRejected-Finance | ₹57.8 L | 5th | Rejected-Finance Not being L1 |
| Sl No | Description | Qty | Unit | Shri Sai Electricals L1 | Mahindra Electric Stores L4 | tulsani associates L2 | NATIONAL ENGINEERING CORPORATION L6 | SHREE VAIBHAV ELECTRICALS L5 | Om Sai Enterprises L3 |
|---|---|---|---|---|---|---|---|---|---|
| 1.00 | Taking down unserviceable any type of pole and Supply & erect in repair in position steel tubular pole swagged type as per IS 2713 complete with MS base plate finial tapper plug cap bolt, nut, screws etc all as specified for swaged pole of type 410 SP 31 , 09 mtrs long incl painting with two coats of aluminium paint over a coat of red oxide paint all as directed including removing existing pole.( Note :- Excavation and earth work and PCC in foundation shall be measured and paid separately) | 10 | Each | 11,000 ₹1.1 L | 18,000 ₹1.8 L | 12,009.7 ₹1.2 L | 22,000 ₹2.2 L | 18,525 ₹1.9 L | 11,000 ₹1.1 L |
| 2.00 | Taking down unserviceable any type of pole, supply & errection in repair in position steel tubular pole swagged type as per IS 2713 complete with MS base plate finial tapper plug cap bolt, nut, screws etc all as specified for swaged pole of type 410 SP 55 , 11 mtrs long incl painting with two coats of aluminium paint over a coat of red oxide paint all as directed including removing existing pole.( Note :- Excavation and earth work and PCC in foundation shall be measured and paid separately) | 10 | Each | 14,500 ₹1.4 L | 27,000 ₹2.7 L | 16,443 ₹1.6 L | 30,000 ₹3 L | 23,560 ₹2.4 L | 15,000 ₹1.5 L |
| 3.00 | M&L for painting of steel tubler LT pole any type any description including cross arm bracing with one coat of white sylver colour , including the marking of pole no all as directed. | 200 | Each | 100 ₹20,000 | 200 ₹40,000 | 140 ₹28,000 | 250 ₹50,000 | 250 ₹50,000 | 300 ₹60,000 |
| 4.00 | M&L for earthing complete with galvanized steel pipe electrode,40mmbore,medium grade,2.5 Mtrers length,buried directly and preferably vertically in ground with top edge not less than 1.25 meters below ground leavle cinnected with earthing lead of 4mm dia galvanised iron or steel wire all as shwn in Plate no-2 to the earthing test point all as specified and indicated including testing on completion. | 20 | Each | 3,000 ₹60,000 | 4,000 ₹80,000 | 6,000 ₹1.2 L | 9,000 ₹1.8 L | 4,750 ₹95,000 | 1,500 ₹30,000 |
| 5.00 | Earthing complete with galvanised steel earth plate electrode 60×60cm.× 6mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less'than 1.5 metres below normal ground level, connected to galvanised earth lead using galvanised iron strip 25×4mm as earthing lead by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 3 connected to earthing test point all as specified or indicated including testing on completion.(For all installation transformer) | 20 | Each | 2,000 ₹40,000 | 4,000 ₹80,000 | 4,109 ₹82,180 | 8,500 ₹1.7 L | 6,175 ₹1.2 L | 1,500 ₹30,000 |
| 6.00 | Taking out LT Cable of any size(10 sqmm 2/4 core to 240 sqmm 3.5 core) for reuse or under Schedule of credit to contractor.Note:- Excavation is not included in quoted rate and will be measured & paid separately. | 5,200 | RM | 1 ₹5,200 | 5 ₹26,000 | 5.2 ₹27,040 | 50 ₹2.6 L | 7 ₹36,400 | 1 ₹5,200 |
| 7.00 | Supply ,laying ,commossionong,testing in repair UG cable 70 Sq mm x 3.5 core ,XLPE insulated screened PVC bedded ,galvanized steel strip or wire armoured ,electric power cable heavy duty 1100 volts grade with stranded aluminum conducter all as directed Note ; Some place schedule of credit wil be ACSR conductor. | 700 | RM | 445 ₹3.1 L | 543 ₹3.8 L | 445 ₹3.1 L | 585 ₹4.1 L | 397 ₹2.8 L | 410 ₹2.9 L |
| 8.00 | All as per item-7 here in before but size of cable 6 Sqmm x 4 Core all as directed. | 400 | RM | 120 ₹48,000 | 222 ₹88,800 | 104 ₹41,600 | 160 ₹64,000 | 119 ₹47,600 | 95 ₹38,000 |
| 9.00 | All as per item-7 here in before but size of cable 10 Sqmm x 2 Core all as directed. | 300 | RM | 130 ₹39,000 | 222 ₹66,600 | 100 ₹30,000 | 170 ₹51,000 | 115 ₹34,500 | 95 ₹28,500 |
| 10.00 | All as per item-7 here in before but size of cable 10 Sqmm x 4 Core all as directed. | 800 | RM | 195 ₹1.6 L | 149 ₹1.2 L | 122 ₹97,600 | 220 ₹1.8 L | 163 ₹1.3 L | 135 ₹1.1 L |
Updated dates
Tender Value
₹62 L
EMD Value
₹1.2 L
Closing Date
11 Dec 2025, 6:00 pmClosed
Shri Vinay Kumar, IDSE, SE (SAG), CWE
HQ Commander Works Engineer (Army) Mumbai, 24 Assaye Building Colaba Mumbai-05
MAINT AND REPAIR OF LT DISTRIBUTION, UG CABLE, LOW TENSION OVERHEAD LINE AND UNDER GROUND CABLE, REPAIR AND MAINT OF EXTERNAL PANEL, FEEDER PILLAR BOX AND ALLIED WORKS UNDER GE DEHU ROAD
2025_MES_738848_1
85222/P/E8
Open Tender
Electrical and Maintenance Works
180 days
Dehu Road Pune
As per NIT and tender documents
8 documents required · 8 mandatory
₹1,000
Yes
GE DEHU ROAD PUNE
₹1.2 L
Yes
18 May 2026
7 Nov 2025
13 Dec 2025
7 Nov 2025
11 Dec 2025
28 Nov 2025
Amount
Taking down unserviceable any type of pole and Supply & erect in repair in position steel tubular pole swagged type as per IS 2713 complete with MS base plate finial tapper plug cap bolt, nut, screws etc all as specified for swaged pole of type 410 SP 31 , 09 mtrs long incl painting with two coats of aluminium paint over a coat of red oxide paint all as directed including removing existing pole.( Note :- Excavation and earth work and PCC in foundation shall be measured and paid separately)
Taking down unserviceable any type of pole, supply & errection in repair in position steel tubular pole swagged type as per IS 2713 complete with MS base plate finial tapper plug cap bolt, nut, screws etc all as specified for swaged pole of type 410 SP 55 , 11 mtrs long incl painting with two coats of aluminium paint over a coat of red oxide paint all as directed including removing existing pole.( Note :- Excavation and earth work and PCC in foundation shall be measured and paid separately)
M&L for painting of steel tubler LT pole any type any description including cross arm bracing with one coat of white sylver colour , including the marking of pole no all as directed.
M&L for earthing complete with galvanized steel pipe electrode,40mmbore,medium grade,2.5 Mtrers length,buried directly and preferably vertically in ground with top edge not less than 1.25 meters below ground leavle cinnected with earthing lead of 4mm dia galvanised iron or steel wire all as shwn in Plate no-2 to the earthing test point all as specified and indicated including testing on completion.
Earthing complete with galvanised steel earth plate electrode 60×60cm.× 6mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less'than 1.5 metres below normal ground level, connected to galvanised earth lead using galvanised iron strip 25×4mm as earthing lead by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 3 connected to earthing test point all as specified or indicated including testing on completion.(For all installation transformer)
Supply ,laying ,commossionong,testing in repair UG cable 70 Sq mm x 3.5 core ,XLPE insulated screened PVC bedded ,galvanized steel strip or wire armoured ,electric power cable heavy duty 1100 volts grade with stranded aluminum conducter all as directed Note ; Some place schedule of credit wil be ACSR conductor.
All as per item-7 here in before but size of cable 6 Sqmm x 4 Core all as directed.
All as per item-7 here in before but size of cable 10 Sqmm x 2 Core all as directed.
All as per item-7 here in before but size of cable 10 Sqmm x 4 Core all as directed.
All as per item-7 here in before but size of cable 16 Sqmm x 2 Core all as directed.
All as per item-7 here in before but size of cable 16 Sqmm x 4 Core all as directed.
All as per item-7 here in before but size of cable 25 Sqmm x 4 Core all as directed.
All as per item-7 here in before but size of cable 35 Sq mm x 3.5 core all as directed.
All as per item-7 here in before but size of cable 50 Sq mm x 3.5 core all as directed.
All as per item-7 here in before but size of cable 95 sqmm X 3.5 core all as directed.
All as per item-7 here in before but size of cable 120 sqmm X 3.5 core all as directed.
All as per item-7 here in before but size of cable 185 sqmm X 3.5 core all as directed.
Supply and laying GI tubing 50 mm dia light grade for cable protection all as directed..
Supply and laying GI tubing 80 mm dia light grade for cable protection all as directed.
Dismantling and taking down MS cross arms, bracing supports, clamps, back plates, hooks etc fabricated from structural steel section from dismantled/existing LT poles of any type or description complete all as specified and directed.
Fixing only MS cross arms, bracing supports, clamps, back plates, hooks etc fabricated from structural steel section from dismantled/existing LT poles of any type or description complete all as specified and directed.
M&L cross arms, bracing supports, clamps, back plates, hooks etc fabricated from structural steel section (MS channel, angle sections, flat, round or square bars ) for reqd sizes and shape including bolts nuts & washers welding bending cutting cold or hot drilling holes for inserting in any shape or size as indicated or directed complete incl painting ( one red oxide primer coat two coats of aluminium paint ) complete.
Supply and fix GI strip 25 x 3.15mm with saddles and fixing screws etc. for roof conductors and down conductors above ground all as directed.
Dismentling / Taking down old Aluminium conductor steel rainforced any type and size.
Supply, stringing, streaching and binding in replacement with insulator, ACSR conductor (Weasel /ferret/Mink) on HT/LT Poles including providing of necessary jumpers, connecting all existing incoming and out going connections etc all as specified & directed.
Re-Fixing/re-stringing Aluminium conductor steel rainforced of any type and size on existing steel tubular / PCC poles including winding, jumpering with alkathine pipe etc complete all as specified and as directed.
Dismantling and taking down insulators of any size from dismantled/existing LT poles of any type or description complete all as specified and directed.
M & L for LT insulator, PIN type 1100 volts as per IS 1445, grade of size 100mm height, 65mm dia, porcelain, vitreous, white or brown including one galvanised mild steel spindle, two galvanised iron washers and one galvanised iron nut including taking down existing unserviceable insulator all as directed.
Fixing only LT insulator, PIN type, 1100 volts grade of size 100mm height, 65mm dia, porcelain, vitreous, white or brown including one galvanised mild steel spindle, two galvanised iron washers and one galvanised iron nut including taking down existing unserviceable insulator all as directed.
Excavation in trenches Soft / loose soil not exceeding 1.5m wide and not exceeding 1.5 m in depth and getting out all as specified and directed.
Excavation in trenches for errection of poles etc.,n. exc 1.5m wide, exc 1.5m and n. exc 3.0m in depth and getting out in soft / loose soil complete all as specified and directed.
Returning, filling in soil, including spreading, leveling watering and well ramming in layers not exceeding 25 cm all as specified and directed.
Removing excavated material not exceeding 50m and depositing where directed at a level not exceeding 1.5 m above the starting point of any type of excavation all as specified and directed.
Demolition of PCC coping , base , etc any type any location all as directed.
M&L for provision of PCC 1:4:8, type D2 (using 40mm graded stone aggregate) as in foundation filling and mass concrete complete all as specified and as directed.
M & L for plain cement concrete 1:3:6 type C1 (using 20mm graded stone aggregate) as in plinth, platforms, pole coping etc., all as specified and as directed.
M & L for plain cement concrete 1:2:4 type B1 (using 20mm graded stone aggregate) as in plinth, platforms, pole coping etc., all as specified and as directed.
(viii) The panel shall provisioned compartments for fixing the following:- (a) MCCB 250/200 Amp TPN,( as in comming)- 01 No. (b) MCCB 160/100 Amp TPN, (outgoing) - 02 Nos). (c) MCCB 63 Amp TPN,(outgoing) - 02 Nos. (d) MCCB 40Amp TPN,(outgoing) - 02 Nos Note: (1) The Feeder pillar panel should be front & back openable and hinged door lock handle (2) The door should be tightened with rubber gasket (3) Each compartment have door, lock and Main bus bar and MCCB input & outgoing connection should be suitable size copper bus bar, nut & bolts etc (4) All incomming & out going cable connected through new suitable size copper gland and aluminium lugs, nut & bots etc. (5) This item include the cost of MCCBs & MCBs,
Supply ,Install,commissioning and testing totally enclosed LT cubicle panel board outdoor double door front and back sloped canopy (Hood) on top, incoming and out going feeders duly marked on revited plates etc complete factory made fabricated out of 3mm thick CRCA sheet duly treated through 7 tank pre treatment process and painted with epoxy powder coated mat finish of SIEMENS GREY structural RAL 7032 shade colour,built in industrial type locking arrangement on front and back ,and pre wired with PVC insulated multi stranded copper conductor of suitable size for controls and monitors, PVC sleeved aluminium strip for connecting MCCBs ,Panel mounted on Anlge iron frame of sutable size of 50mm x 50mm x 6mm thick MS angle, 45 CM above ground level & 30 CM below gland consisting of following;- Busbar Chamber: Electrically grade Bus bar aluminium of capacity equal to 1.5 times of rated incoming control switch gear including interconnection of all switch gears duly insulated with colour coded heat shrinkable sleeve and mounted on suitable size of 'F' class insulators made of non hygroscopic,non combustible,track resistant high strength FRP insulators for phases and neural set of 4 for RYB &N -01 set Incoming:- (a) MCCB 160 amps 4 pole 16 KA,DPX³ MCCB with Thermal Magnetic Protection Unit - 01 Nos.Make: Legrand,Schiender,Seimens (b) Advanced Multi functional meter 4420 series LCD meter C1 with RS481 MAKE :- CAT No WC442011OOOO of Make: Legrand,Schiender,Seimens (c) LED type indication lamp for RYB.
Outgoing: (a) MCCB 100 amps 4 pole 16 KA,DPX³ MCCB with Thermal Magnetic Protection Unit - 02 Nos. Make: Legrand,Schiender,Seimens (b) MCCB 63 amps 4 pole 16 KA,DPX³ MCCB with Thermal Magnetic Protection Unit - 01 Nos Make: Legrand,Schiender,Seimens NOTE ; (1) The Feeder pillar panel should be front & back openable and hinged door lock handle (2) The door should be tightened with rubber gasket (3) Each compartment have door, lock and Main bus bar and MCCB input & outgoing connection should be suitable size copper bus bar, nut & bolts etc (4) All incomming & out going cable connected through new suitable size copper gland and aluminium lugs, nut & bots etc. (5) This item include the cost of MCCBs & MCBs,
Supply and fixing MCCB 400 Amp, 4 pole, 415 V,with breaking capacity 25 KA ,as per Conforms to IS-13947-2 and IEC 60947-2.
Supply and fixing MCCB 250 Amp, 4 pole, 415 V,with breaking capacity 25 KA ,as per Conforms to IS-13947-2 and IEC 60947-2.
Supply and fixing MCCB 200 Amp, 4 pole, 415 V,with breaking capacity 25 KA ,as per Conforms to IS-13947-2 and IEC 60947-2.
Supply and fixing MCCB 160 Amp, 4 pole, 415 V,with breaking capacity 16 KA ,as per Conforms to IS-13947-2 and IEC 60947-2.
Supply and fixing MCCB 125 Amp, 4 pole, 415 V,with breaking capacity 16 KA ,as per Conforms to IS-13947-2 and IEC 60947-2.
Supply and fixing MCCB 100 Amp, 4 pole, 415 V,with breaking capacity 16 KA ,as per Conforms to IS-13947-2 and IEC 60947-2.
Supply and fixing MCCB 63 Amp, 4 pole, 415 V,with breaking capacity 10 .
Supply and fixing MCB 6 - 40 Amp, 2 pole, 220 V,with breaking capacity 10 KA .
M & L in repair HDPE DWC pipe 40 mm dia ISI Marked fixed on walls, ceilings or in floors, trenches etc. for cable protection all as directed.
M & L in repair HDPE DWC pipe 50 mm dia ISI Marked fixed on walls, ceilings or in floors, trenches etc. for cable protection all as directed.
M & L in repair HDPE DWC pipe 80 mm dia ISI Marked fixed on walls, ceilings or in floors, trenches etc. for cable protection all as directed.
Supply installation fabricated MS ring suitable for fixing six/five number flood light on top portion of MS pole.Note:- The rate including the fixing arrangement of light fitting complete all as directed.
Taking down the unserviceable light fitting any type, supply and fixing Flood light(SMD Type) 120 watt with high pressure die cast housing with IP66,surge protection light netural warm white, all as directed.
Supply and fix in replacement of fibre looping box with connector and MCB SP 2 to 6 Amps of size 250x200x100 mm including making connections all as specified and directed by Engineer –in –Charge.
S&F in repair Smart Integrated Solar All In One with 40 Watt power Rating, MPPT Charge Controller, Tiltable LED panel,Including Lithinim battery Adjustable AIO mounting angle, Mono Crystalline Solar Panel, PIR motion Sensor, easy to install all as per directed.
S&F in repair Smart Integrated Solar All In One with 60 Watt power Rating, MPPT Charge Controller, Tiltable LED panel,Including Lithinim battery Adjustable AIO mounting angle, Mono Crystalline Solar Panel, PIR motion Sensor, easy to install all as per directed.
Supply & fix cable jointing kit of cable 10 to 16 sqmm, 1100V XLPE grade cable for straight through Heat shrink type joint complete with jointing material and accessories suitable for 3.5/4 core XLPE armoured aluminium conductor cable complete all as specified and directed.
All as item no-59 here in before but size of cable 25 to 30 sqmm,3.5/4 core
All as item no-59 here in before but size of cable 70 to 95 sqmm,3.5/4 core
All as item no-59 here in before but size of cable 120 to 240 sqmm,3.5/4 core
Taking down unserviceable street light fitting and supply and fixing LED SMD Type street light fittings 60W 3000K with DPD energy saving & environmental friendly long life Versatile pressure die-cast aluminium IP66 roadway luminaire with necessary Bracket 50 mmGI Pipe with extended arm ,with Clamp ,nut& Bolts complet all as directe.
Taking down unserviceable street light fitting and supply and fixing LED SMD Type street light fittings 90W 3000K with DPD energy saving & environmental friendly long life Versatile pressure die-cast aluminium IP66 roadway luminaire with necessary Bracket 50 mmGI Pipe with extended arm ,with Clamp ,nut& Bolts complet all as directe.
Taking down unserviceable street light fitting and supply and fixing LED SMD Type street light fittings 120W 3000K with DPD energy saving & environmental friendly long life Versatile pressure die-cast aluminium IP66 roadway luminaire with necessary Bracket 50 mmGI Pipe with extended arm ,with Clamp ,nut& Bolts complet all as directe.
Supply only PVC insulated and unsheathed cable of size 1.5 Sqmm single core multistranded copper conductor FR cable 1100 V grade confirming to IS 694.
Taking down unserviceable Aluminium cable lug 120/95/240 sqmm and supply with fixing the same all as directed.
Taking down unserviceable Aluminium cable lug 50/70 sqmm and supply with fixing the same all as directed.
Taking down unserviceable Aluminium cable lug 25/35 sqmm and supply with fixing the same all as directed.
Taking down unserviceable Aluminium cable lug 16/10 sqmm and supply with fixing the same all as directed.
S&F in repair On load change over switch 415V,4 pole with current capacity 200 amp.
S&F in repair On load change over switch 415V,4 pole with current capacity 125/160 amp.
S&F in repair On load change over switch 415V,4 pole with current capacity 63/100 amp.
M & L to find out fault location in 11000 V /415 V UG Cable of any size by using cable fault locator directed by all as specified and directed by Eng in charge. Note:-Contractor must bring cable fault locator at site within 24 hours of intimation otherwise recovery @ Rs 1000/Hr will be charged after 24 hours.
Disconnecting the incomming and out going cable connection from unserviceable LT panel. Dismelting the all MCCB, and other control equiptment, Measuring instrutment, Bus bar and internal cable /copper strip connection. Cutting the worn out sheet/angle and fabricated the new MS sheet/angle with match the existing size and shape. Scrapping the existing paint and repainting painting of the panel board with one coat of red oxide paint as a primer with two coat of synthetic enamel paint to match the existing colour.Refxing the serviceable controll equiptments and connected all incomming/outgoing cables all as directed.Note: (a)The replacement of the unserviceable items and frame work will be measured and paid seperately in respective items.
tulsani associates (BID ID -3489374)
Om Sai Enterprises (BID ID -3489154)
Mahindra Electric Stores (BID ID -3488891)
SHREE VAIBHAV ELECTRICALS (BID ID -3494394)
NATIONAL ENGINEERING CORPORATION (BID ID -3489771)
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.94 MB
Tenderdocuents85222.pdf
Tender Documents • 0.93 MB
BOQ_827308.xls
BOQ • 0.31 MB
Download all tender documents and submit your bid