Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹19.9 CrAccepted-AOC WZ 487 2 MS BLOCK HARI NAGAR NEW DELHI 110064 | NEW DELHI | NEW DELHI | DELHI | 110064 | ₹19.9 Cr | L1 | Accepted-AOC Lowest Bidder |
| 2 | L2₹23.0 CrRejected-AOC 00 00 NAPASAR ROAD NENO KA BASS BIKANER RAJASTHAN BIKANER RAJASTHAN 334022 UDYAM RJ 08 0001676 | BIKANER | RAJASTHAN | 334022 | ₹23.0 Cr | L2 | Rejected-AOC Other than Lowest Bidder |
| 3 | L3₹24.0 CrRejected-AOC | ₹24.0 Cr | L3 | Rejected-AOC Other than Lowest Bidder |
| 4 | L4₹24.5 CrRejected-AOC NATIONAL TOWER 5TH FLOOR SCO 89 DSC RANJIT AVENUE AMRITSAR 143001 PUNJAB | AMRITSAR | AMRITSAR | PUNJAB | 143001 | ₹24.5 Cr | L4 | Rejected-AOC Other than Lowest Bidder |
| 5 | L5₹26.1 CrRejected-AOC | ₹26.1 Cr | L5 | Rejected-AOC Other than Lowest Bidder |
Tender Value
₹17 Cr
EMD Value
₹11.8 L
Closing Date
1 Sept 2022, 6:00 pmClosed
CE Chandigarh Zone
HQ CE Chandigarh Zone N Area, Airport Road Chandigarh-160003
CA NO CE CHZ/PAT/T-03/2022-23 PROVN OF AUDITORIUM CUM CINEMA HALL (SITTING CAPACITY 1200) AT PATIALA
2022_MES_520857_2
CE CHZ/PAT/T-03/2022-23
Open Tender
Civil Works
750 days
PATIALA
Please refer Tender Documents
10 documents required · 10 mandatory
₹3,000
GE (SOUTH) PATIALA
₹11.8 L
Yes
17 Feb 2023
26 Jul 2022
3 Sept 2022
26 Jul 2022
1 Sept 2022
20 Aug 2022
26 Jul 2022 - 5 Aug 2022
Amount
Total amount of Sch 'A' Sec-I ( BUILDING WORKS ) Lump sum price worked out by the contractor for " BUILDING WORKS " as listed in schedule 'A' Part-I
Total amount of Sch 'A' Sec II (SITE CLEARANCE, SITE DEVELOPEMENT & MISC. EARTH WORKS) Lump sum price worked out by the contractor for " SITE CLEARANCE & Earth Works " as listed in schedule 'A' Part-II
Total amount of Sch 'A' Sec III ( INTERNAL WATER SUPPLY WORKS ) Lump sum price worked out by the contractor for " BUILDING WORKS " as listed in schedule 'A' Part-III
Total amount of Sch 'A' Sec IV (INTERNAL ELECTRIFICATION WORKS) Lump sum price worked out by the contractor for " INTERNAL WATER SUPPLY WORKS " as listed in schedule 'A' Part-IV
Total amount of Sch 'A' Sec V (SEWAGE DISPOSAL WORKS) Lump sum price worked out by the contractor for " SEWAGE DISPOSAL WORKS " as listed in schedule 'A' Part-V
Total amount of Sch 'A' Sec VI (AREA DRAINAGE WORKS) Lump sum price worked out by the contractor for " AREA DRAINAGE WORKS " as listed in schedule 'A' Part-VI
Total amount of Sch 'A' Sec VII (SECURITY WALL, FENCING & GATE WORKS) Lump sum price worked out by the contractor for " SECURITY WALL/FENCING WORKS " as listed in schedule 'A' Part-VII
Total amount of Sch 'A' Sec VIII (ROAD, PATH, CULVERTS AND HARDSTANDING WORKS) Lump sum price worked out by the contractor for " ROAD/PATH/CULVERT WORKS " as listed in schedule 'A' Part-VIII
Total amount of Sch 'A' Sec IX (EXTERNAL WATER SUPPLY WORKS) Lump sum price worked out by the contractor for " EXTERNAL WATER SUPPLY WORKS " as listed in schedule 'A' Part-IX.
Total amount of Sch 'A' Sec X (EXT ELECTRIC SUPPLY & LIGHTENING PROTECTION WORKS) Lump sum price worked out by the contractor for " EXTERNAL ELECTRIFICATION WORKS " as listed in schedule 'A' Part-X.
Total amount of Sch 'A' Sec XI (FIRE ALARM AND FIRE FIGHTING SYSTEM ) Lump sum price worked out by the contractor for " SFIRE ALARM AND FIRE FIGHTING SYSTEM " as listed in schedule 'A' Part-XI.
Total amount of Sch 'A' Sec XII (DEMOLITION WORKS) Lump sum price worked out by the contractor for " DEMOLITION WORKS " as listed in schedule 'A' Part-XII.
Schedule 'A'Section-XIV (Misc Items of Works) Note : This schedule is not pre-priced by MES and the pre-priced rate indicated as "Rs 0.00" under Col. 5 siginifies this fact only.
INTERNAL ELECTRICAL SUPPLY WORKS Supply and fixing modular metal flush box of 8 module complete all as specified and directed.
Supply and fixing modular dummy plate complete all as specified.
Supply and fixing RCCB Four Pole module, AC 25 Amp 415V 50 Hz breaking capacity 10 kA with short circuit protection device, sensitivity rating 30mA consisting of T button for checking as per IS : 12640-1 & IEC/EN 61008-1 complete all as specified.
Supply and fixing RCCB Four Pole module, AC 63 Amp 415V 50 Hz breaking capacity 10 kA with short circuit protection device, sensitivity rating 30mA consisting of T button for checking as per IS : 12640-1 & IEC/EN 61008-1 complete all as specified
Supply and fixing MCB DP 6 to 32 Amps, 240 volts, B-curve, rupturing capacity 10KA conforming to IEC-60898, Part-I complete, all as specified & directed.
Supply and fixing MCB SP 6 to 32 Amps, 240 volts, B-curve, rupturing capacity 10KA conforming to IEC-60898, Part-I complete, all as specified & directed.
Supply and fixing lamp holder, brass with back plate and metal ring suitable for modular fittings including LED lamp 6 W 220-240 V 50Hz complete all as specified.
Supply and fixing Ceiling fan energy efficient, minimum service value (m3/minute/Watt)>= 4.5, including modular type electronic step type fan regulator flush type fixed on cover sheet, 230 V, 50 Hz, 1200 mm sweep confirming to IS 374-2019, with all standard accessories as per manufacturer's recommendations ,with provision of PVC insulated flexible cable FRLSH grade 3 core 0.5mm copper conductor 1100 volts grade from porcelain connector /ceiling rose to ceiling fan,complete all as specified and directed.
S & F exhaust fan of 300mm sweep,metal body, heavy duty, double ball bearing, 1400 RPM, 85 watt, 4 blades, air delivery 1710 m3/h, suitable for SP 230/250 Volts, 50 Hz AC supply complete with louver shutter including fixing/ grouting of frame & louvers in wall using bolts of suitable size & connecting with and including PVC flexible copper cable of size 23/00.0076 three core from ceiling rose to fan complete all as directed.
S & F exhaust fan of 380mm sweep,metal body, heavy duty, double ball bearing, 1400 RPM, 160 watt, 4 blades, air delivery 3250 m3/h, suitable for SP 230/250 Volts, 50 Hz AC supply complete with louver shutter including fixing/ grouting of frame & louvers in wall using bolts of bolts of suitable size & connecting with and including PVC flexible copper cable of size 23/00.0076 three core from ceiling rose to fan complete all as directed. Note for item Nos. 22.00 to 23.00 : Cost of opening in wall and grouting of mild steel work shall be deemed include in the lump sum cost of the building.
Supply and fixing energy efficient LED, environment friendly single tube light fittings surfaces/pendent mounted complete with white powder coated slim box type batten of formed CRCA with snap on installer suitable for 1200mm long 20W LED tube rod batten or LED tube light base complete with 1200m long LED rod 1x20 watt, 6500K for white illumination including all accessories and connection from ceiling rose to connector complete all as specified.
Supply and fixing surface mounted opal polycarbonate diffused 1 x 1 feet aesthetically designed LED luminaire flat panel soft light and glare free symmetrical illumination or rating 15W 240V 50 Hz and making electrical connection complete in all respect and as specified.
Supply and fixing LED EXIT light fitting 1 x 3 W, 220-240V, 50 Hz with red sign “EXIT” with indbuilt battery backup for 2 hours and making electrical connection complete complete all as specified and directed.
Supply and fixing energy efficient LED environment friendly security light B-1 class made up of pressure die cast aluminium housing with high power LED as lighting source and lense embedded for area/path illumiunation as per National lighting Code (SP 72:2010) by using security light of 25 watt (total input power), CCT-5000-5500K CRI > 67, PF > 0.95, rated output lumens 2100Im, operating performance temp – 10 degree centigrade to + 45 Degree centigrade LED module life span 50000 buming hrs, with toughened glass cover, external surge and over voltage protection device up to 440V alongwith connection 3 core copper flexible cable of size 0.75 Sqmm to be provided with weather proof connector, LED module & driver protection class IP-66 rated duly ISI marked IS:16013 part (1 &2) 2012: efficiency 85% constant current Vtd < 10% ithd< 15% complete with 40mm dia GI pipe light grade 1.5 mtr long bracket and Fl 40 x 6 mm clamp 2 Nos with nut bolts etc including painting of clamps with two coats of aluminium paint over a coat a of primer (for bldg security lights) complete all as specified.
Supply and fixing energy efficient LED, environment friendly, linear and compact 9 watt mirror light with decorative end caps, polycarbonate body and ribbed opal diffuser LED rod 1 x 9W, CCT 6000K, 220-240V, 50Hz for white illiumination including all accessories and connection from ceiling rose to connector complete all as specified.
Supply and fixing energy efficient, environment friendly, long life die cast aluninium IP 65 powerful LED luminaire with high power LED as light source with lumen efficacy> 100lm/W, CCT>5700K, operating temperature-10 to +50 degree centigrade, 220-240V, 50 Hz 240 watt and surge protection 5 KV, pf>0.95 complete all as specified and directed.
Supply and fixing halogen light/stage filler light 1000W, 220-240V, 50 Hz, complete as all specified.
Supply and fixing LED Fresnel spot light fitting 200 watts 220-240V, 50 Hz complete all as specified.
Supply and fixing LED profile spot light for sharp focusing, 300 watts 220-240V, 50 Hz complete all as specified and directed.
Supply and fixing porch light energy efficient LED, environment friendly, aestheritically designed, moulded body, ceiling light LED fixture IP 54 with diffuser to give glare free light with lamp LED 1 x 8/9W 6000K, 220-240V 50 Hz complete as all specified and directed.
Supply, install, testing and commissioning, factory made and tested (incl CPRI type test certified), LT panel of appropriate dimensions (as per Indian Electricity rules) to accommodate following components, indoor type, platform/floor mounted, suitable for 415 volts 3 phase 4 wire, 50 Hz AC supply system. The panel shall be dust and vermin proof, IP 54 class protection and made of 2.0mm thick CRCA MS sheet and 40x40x6mm thick angle iron frame work, extendible at both ends with aluminum bus bar, fully compartmentalized, powder coated finish over one coat of red oxide primer outside and two coats of red oxide primer on inside, front & rear opening type, with aprons for cable entry, with removable door shutter and locking arrangement (including provn of 65mm Godrej (Freedom) lock with 2 keys, internal wiring with PVC insulated, multistranded copper conductor, FRLS cables, IS-694 marked of adequate size but not less than 4 sqmm. The scope of work includes the following:- COMPONENTS INCOMING (a) Aluminium bus bar of rating 400 Amps for four pole including PVC heat shrink sleeves (RYB & N ) : 01 Set (b) MCCB four pole 160 Amp confirming to IEC 60947-2 & IS – 13947-3 thermal magnetic release and adjustable over load setting 0.8 – 1.0 x In and adjustable short circuit setting 6 – 10 x In and rupturing capacity 35 KA at 415 V AC , 50 Hz complete - 01 No. OUTGOING (A) MCCB four pole 40 Amp confirming to IEC 60947-2 & IS – 13947-3 thermal magnetic release and adjustable over load setting 0.8 – 1.0 x In and adjustable short circuit setting 6 – 10 x In and rupturing capacity 25 KA at 415 V AC , 50 Hz complete - 01 No. (B) MCCB four pole 63 Amp confirming to IEC 60947-2 & IS – 13947-3 thermal magnetic release and adjustable over load setting 0.8 – 1.0 x In and adjustable short circuit setting 6 – 10 x In and rupturing capacity 25 KA at 415 V AC , 50 Hz complete - 02 Nos. (c) MCB TPN 32 Amp and rupturing capacity 10 KA at 415 V AC , 50 Hz complete - 02 Nos.
Supply and installing single sided LED signage (Gents Toilet) with 3W LED of red/green colour including built in battery backup for 2 hours complete all as specified and directed.
Supply and installing single sided LED signage (Ladies Toilet) with 3W LED of red/green colour including built in battery backup for 2 hours complete all as specified and directed.
M&L for installing LED row light fitting 2W fixed in recess of chair including painting of alphabets & numbers as directed by Engineer-in-Charge.
Supply and installation of electronic inverter of 3 KW capacity complete including 12V maintenance free battery of 180AH (One No.) suitable for inverter, including trolley for mounting inverter and battery, PVC multisranded copper connection wire of appropriate size etc complete all as specified and directed.
Supply and installing single sided LED signage (Entry) with 3W LED of red/green colour including built in battery backup for 2 hours complete all as specified and directed.
S&F of pedestal fans, 450mm sweep, 230V single phase oscillating type 230V, AC 50 Hz complete all as specified and directed.
S&F of wall mounted cabin fans, 450mm sweep, 230V single phase oscillating type 230V, AC 50 Hz including fixing accessories complete all as specified and directed.
Supply and fixing voltage stabilize electronic type for automatic operation, single phase naturally air cooled indoor type and designed for input variation between 170 volts to 270 volts with output voltage stabilized at 230V with accuracy of ± 2.5% and of capacity 3.8/4 KVA complete all as specified.
Supply and fixing SICT of commercial air curtain unit for prevention of dust and conditioned air losses, single phase 230 V 50 Hz, made out of MS/CRCA sheet min thickness 18 gauge finished with two coat of red oxide primer and final coat of synthetic enamel paint (over backed) with MS-CRC 18 gauge square perforated suction grills, aluminium alloys fans and single phase electrics motor, nozzles etc, complete with fittings and accessories so as to produce 1-1.5mm/sec air velocity at floor level for door opening of size 64”x90” complete all as specified and as directed.
S&F step light luminaire powder coated die cast aluminium housing IP 65 protection 3/4W, 220-240V 50 Hz and making electrical connection complete all as specified and directed.
M&L for remote control transmitter with 42-channel for the control of 6 zones and 4 zones and 4 light scenes with dim UP/DOWN and OFF function complete all as specified and directed.
M&L for fabricating and installing of MS pipe ladders to be provided on sides of the stage to be fixed on the GI pipe top grid, make of 50mm x 25mm MS pipe complete all as specified and directed.
Supply, fixing & testing of perforated powder coated MS cable trays 40 x 100, 2mm thick including horizontal and vertical bends, reducers, tees, cross members and other accessories as required and duly suspended from the ceiling with MS suspenders etc complete all as specified and directed.
ROAD, PATH, CULVERTS AND HARDSTANDING WORKS Providing, Laying, compaction of granular sub-base by providing close graded material conforming to specifications i.e Grading II, conforming to Clause 401 of MORT&H Specifications for Road and Bridge Works (Fifth Revision), mixing in a mechanical mix plant at OMC, carriage of mixed material by tippers to work site, for all leads & lifts, spreading in uniform layers of specified thickness with motor grader on prepared surface and compacting with vibratory power roller of capacity 8 to 12 tonne to achieve the desired density, 150 mm thick compacted thickness, complete all as specified and directed by Engr-in-Charge.
Providing, Laying, compaction of Wet Mix Macadam conforming to Clause 406 of MORT&H Specifications for Road and Bridge Works (Fifth Revision) , 250 mm thick (compacted thickness,125 mm thick in two separate layers) with mechanically crushed graded stone aggregates and granular material (size range 53 mm to 0.075 mm ), grading of aggregates as per Table 400-13 of MORT&H Specifications for Road and Bridge Works (Fifth Revision) ,including premixing the material with water at OMC in for all leads & lifts, laying in uniform layers with mechanical paverfinisher in sub- base / base course on well prepared surface and compacting with vibratory roller of 8 to 12 tonne capacity to achieve the desired density , required gradient and camber etc., complete all as specified and directed by Engineer-in-Charge. NOTES: 1. The WMM shall be laid in two layers i.e each layer of 125 mm thick (compacted thickness). 2. For payment purpose,both layers shall be considered as one unit.
Preparation of un-surfaced Wet Mix macadam (WMM) surfaces by brushing with wire brushes for re-moving caked mud ,dust, loose material, foreign material etc., sweeping with power brooms and finally fanning the cleaned surface with air compressors to remove all loose dirt etc. and applying evenly a priming coat on un-surfaced wet mix macadam surfaces conforming to Clause 502 of MORT&H Specifications for Road and Bridge Works (Fifth Revision), with cationic bituminous emulsion SS1 grade,confirming to IS 8887(latest edition) @ 7.5 kg per 10 sq metres using primer distributor which shall be self-propelled or towed bitumen pressure sprayer complete all as specified and directed by Engineer-in-Charge.
Providing, laying & compaction of Bituminous Macadam (BM) 50 mm Compacted thickness conforming to Clause 504 of MORT&H Specifications for Road and Bridge Works (Fifth Revision), using mechanically crushed stone aggregates and granual material etc. of grading II as per Table 500-7 of MORT&H Specifications for Road and Bridge Works (Fifth Revision), premixed with bituminous binder, Bitumen grade VG-30 @ 3.50% (percentage by weight of total mix) prepared in Batch Type Hot Mix Plant of 100-120 TPH capacity transported to site by tippers, laid over a previously prepared surface with paver finisher equiped with electronic sensor to the required grade, level and alignment and rolling with smooth wheeled, vibratory and tandem rollers as per specifications to achieve the desired compaction and density complete all as specified and directed by Engineer-in-Charge. Notes : (i) The contractor shall quote the rate against Item considering 3.5% VG-30 bitumen content. Job mix formula as per MoRT&H specifications for road and bridge work (Fifth Revision) for bituminous concrete shall be got designed from NIT/ CTL/ Govt Engg College and shall be got approved from GE in writing well before commencement of work without any financial effect to the department. Also the bitumen content shall not be less 3.4% by weight of total mix as per clause 504.2.4 of MoRT&H specifications (Fifth Revision). (ii) If qty of binder contents is less than the qty as specified in respective items of BOQ, it shall be adjusted at supply only rates of paving bitumen @ Rs 45.00 Per Kg and if qty of binder contents is more than the qty as specified in respective items of BOQ no adjustment shall be made.
Preparation of surfaces and applying evenly a Tack coat conforming to Clause 503 of MORT&H Specifications for Road and Bridge Works (Fifth Revision), with cationic bituminous emulsion RS1 grade,confirming to IS 8887(latest edition) @ 2.5 kg per 10 sq metres using using primer distributor which shall be self-propelled or towed bitumen pressure sprayer complete all as specified and directed by Engineer-in-Charge.
Providing and laying 30 mm thick (consolidated thickness) Bituminous Concrete (BC) layer conforming to clause 507 of MoRT&H specifications for road and bridge work (Fifth Revision) including cost of coarse aggregates, fine aggregates, filler, 5.5% binder (paving Bitumen grade VG-30) content by weight of total mix and crushed aggregates of grading 2, Anti Stripping Agent, Warm Mix Additives (quantity, quality and grade as per the approved Job Mix Formula) etc, cleaning and pre-heating of the mineral aggregate, filler & bitumen to the specific temperature, thoroughly mixing with binder of specified bitumen content, Anti Stripping Agent, Warm Mix Additives as per mix design in Hot Mix Plant of 100-120 TPH capacity, carrying the hot mixed materials by means of tipper, trucks, or any other approved and suitable arrangements, laying the hot premixed materials over the prepared surface by means of paver finisher including manual operation as and when required for proper grade, level and camber thorough rolling with power roller 8 to 12 tonnes smooth wheeled, vibratory and tandem roller with necessary hand packing and pinning to give an even surface, including running expense of all plants and machineries, inclusive of proper traffic control during laying to the satisfaction of Engineer-in-Charge, required quality control tests at required interval etc complete in all respects complete all as specified and directed by Engr-in-Charge.
M & L for precast (factory casted) cement Concrete kerb stone casted in PCC (1:2:4) type B-1 using 20mm graded stone aggregate with plain or interlocking joints (as directed), making groove in existing road of desired dimension, placing in erect position Kerb stone in edging and set and jointed in cement mortar 1:4, making good distrubed surface of ground complete all as specified and directed.
EXTERNAL WATER SUPPLY M & L Cutting existing 150mm bore cast iron water mains at-least at two places in position for inserting new tee and inserting cast iron tee of size 150mm x 150mm x 80mm including provision of connecting pieces and other fittings as required including run lead/ flanged joints etc complete all as specified and directed.
Supply, laying, jointing and testing ductile iron pipe having nominal diameter DN 80mm with socket and spigot ends class K-7 including rubber tyton ring joints suitable for ductile iron pipe complete all as specified and directed.
M & L for ductile iron pipe fittings ISI marked like bends, tapers, tail pieces, tee, branch pieces (single/double) any type and angle/radius and straight connecting pieces complete all as specified and directed.
M & L for construction of brick masonary valve pit of size 900 mm x 900mm x 900 mm (Internal size) thickness of walls shall be 23cm in brick work in cement mortar 1:6 internally plastered in cement mortar (1:6) and externally plastered in cement mortar (1:4) over 15cm thick PCC 1:4:8 type D-2 in foundation having 15cm offset around, including 4 cm thick coping in PCC 1:2:4 type B-1 on the top of the brick wall and 3mm thick mild steel sheet cover and angle iron frame of size 40 mm x 40mm x 6mm including provn of suitable hold fasts to hold the frame, locking arrangement and lifting handle, duly painted with two coats of synthetic enamel paint, over a coat of red oxide primer, complete all as specified and as directed.
EXTERNAL ELECTRIFICATION Supply, installing, testing and commissioning of Air-break, gang operated, triple pole switch with drop out fuses, outdoor, horizontal mounting type (ISI marked), mechanically operated, mounted on 12 Nos insulators for current rating upto 200 Amps complete with operating mechanism fabricated from 25mm bore GI pipe with steel frame worked from ground level, with locking arrnagments including Godrej pattern 65mm pad locks with two keys, complete suitable for HT 11 KV, 50 Hz AC supply and making necessary electric connections, complete all as directed.
Supply and fixing in truly verticle position, steel tubular swaged pole, type 410 SP-22 (8.5 metre long) complete finial taper plug, bolts, nuts, scerws as specified, CI base plate including drilling holes and painting with two coats of black bituminous paint externally and internally, providing 30cm wide alternate strips with yellow and black synthetic enamal paint upto 1.2m height from ground level and numbering the pole (with black and white paint), undergruound part of the pole shall be painted with black bituminous paint complete all as specified and as directed. Note: Excavation, earthwork, PCC foundation shall be measured and paid separately.
Supply and erecting vertical prestressed concrete pole 11.0 metres long, 152mm x 152mm at top and 152mm x 260mm at bottom class 9 complete including two coats of paint over a coat of primer above ground level, painting the pole with alternate black and yellow paint strip band 30cm long, 5 Nos with synthetic enamel paint etc omplete all as specified and directed. NOTE:- (i) Earthwork and PCC shall be measured and paid separately. (ii) Cross arms shall be measured and paid seperately.
S & F decorative LED post top fitting powder coated aluminium die cast and and spun with clear diffuser of capacity 25 Watts complete all as directed. Model & Make : Model No. PCGLPT 01 25C of Make Polycab or equivalent model of makes listed in List of makes.
S & F energy efficent LED street light with lens IP 66 with PDC aluminium body and clear glass LED LENS for wide beam distribution Efficacy>100Lm/W fitting 25 watts complete all as specified and directed Model & Make : Model No. PCGLS T1 25L of Make Polycab or equivalent model of makes listed in List of makes.
S & F Junction box of size 250x200x150 mm, made out of 1.6 mm thick MS sheet , having alluminium bus bar strip 4 Nos mounted on insulatars and 1 Nos outgoing MCB 6 Amps SP 240 Volts, the juction box should front openable and lockable hinged shutter with self closing arrangement, outdoor type weather and vermin proof including fixing lamp, provision of entry for incoming and outgoing cables complete duly painted with two coats of silver paint over a coat of red oxide primer complete all as specified and directed
Test point terminal block made of gun metal or phosphorous bronze 75x75x25mm drilled and screwed including 04 Nos 8mm dia 25mm long hexagonal head brass screws including box of size 90x90x90mm made of 1.6mm CRCA sheet painted with two coats of synthetic enamel paint over a coat of red oxide primer, and screwed to wall for protection of test point complete incl covered with 3mm thick laminated sheet complete all as specified and as directed.
Supplying, laying, jointing, testing and commissioning 120 Sqmm, 3 core, XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cable (heavy duty) with aluminum conductors, 11 KV grade of , IS 7098 marked, suitable for HT 11 KV(E) system, laid in trenches / ducts / encased in GI pipe / fixed to pole complete all as specified and directed. (Note :- Excavation & earth work, GI pipe for laying of cable, sand cushioning, cable protection cover shall be measured and paid for seprately under respective items of the schedule.)
Supply/Laying / fixing, jointing, testing and commissioning, LT under ground cable 1100 volts grade XLPE insulated & PVC sheathed cable heavy duty armoured, with multistranded aluminium conductor laid in trenches/ ducts/ pipes/fixed on walls/poles complete all as specified and directed of following sizes:-
2 Core 10 Sqmm
4 Core 25 Sqmm
3.5 Core 50 Sqmm
3.5 Core 70 Sqmm
3.5 Core 95 Sqmm
3.5 Core 185 Sqmm
1 (Single) Core 630 Sqmm (Note :- Excavation & earth work, GI pipe for laying of cable, sand cushioning, cable protection cover shall be measured and paid for seprately under respective items of the schedule.)
M & L for outdoor type heat shrinkable cable end termination jointing kit for HT 11000 Volts(Earthed) grade cable of 3 core 70 to 120 sqmm size complete with jointing material and accessories complete all as directed.
M & L for indoor type heat shrinkable cable end termination jointing kit for HT 11000 Volts(Earthed) grade cable of 3 core 70 to 120 sqmm size complete with jointing material and accessories complete all as directed.
Unreinforced precast concrete cable cover, class HV, type-1, flat, of size 300mm x 180mm x 40mm for protection of HT cable complete all as specified and directed.
Unreinforced precast concrete cable cover, class LV, type-1, flat, of size 250mm x 150mm x 40mm for protection of LT cable complete all as specified and directed.
M & L for dry sand cushioning to PVC under ground cable with screened and washed sand and punning to provide a required cover complete all as specified and directed. Note :- Thickness after punning shall be considered for payment.
Supply, install, commissioning testing of transformer, energy efficient as per IS-1180 Part-1: 2014 and BEE certified Level-2, step down 11KV/433V outdoor type copper wound 500 KVA Cap with necessary, standard fittings of capacity 500 KVA 3 Phase, 4 wire, 50 cycles vetor group Dyn-11 having primary (HT) voltage of 11 KV and secondary (LT) voltage of 433 V off load tap changing gear to provide volts with tapping on primary side having steps of + 2.5% from (+) 5% to (-) 7.5% in equal steps of 2.5% each so as to vary voltage on secondary side including first fill of transformer oil, the transformer shall be delta connected on 11KV side & star connected on secondary side with neutral brought out including provn of HT busing on HV (delta connection) side & LT cable box on LV (star connection) side complete all as specified and directed
Supply insrtall testing and commissioning HT 11 KV 3 phase 50 Hz Outdoor type totally enclosed metal clad switch gear complete with vaccum circuit breaker having rupturing capacity upto 350 MVA overload and earth fault protection, ammeter, voltmeter and of rating upto 630 Amps complete all as specified.
Supply and fix UPS for 25-30 min back up 3 phase AC input 300 to 450 V and output 415 volt of capacity 40 KVA with battery bank consisting of 12V/65 AH- 32 Nos batteries alongwith 125 Amp 3 P DC breaker along with UV coil, control cable, DC breaker to UPS , MS open battery rack and interlinks connector complete solid state designed to provide regulated and corditioned sinusoidal power to linear and non-linear loads, the UPS battery shall be sealed maintenance free battery with protection for fuse , run time 25-30 min complete all as specified and directed Make:Schneider Model No E3SUPS40KHKVA or equivalent.
FIRE ALARM, FIRE FIGHTING SYSTEM AND FIRE HYDRANT SYSTEM : Supplying, installing, testing and commissioning of Electrical driven fire pump (Main Fire Pump and sprinkler pump) suitable for automatic/ manual operation consisting of the following:- (a) Horizontal mounted End Suction type fire pump having cast iron body, bronze impeller, stainless steel shaft & capable of delivering 2850 LPM against a total head of 70 M while running at 2900 RPM complete in all respect. (b) Squirrel cage, induction motor TEFC type suitable for 415 + 10%V, 3 phase, 50 Hz, AC supply, of suitable HP rating for the above pump with synchronous speed of 2900 RPM with flexible coupling and coupling guard. (c) Common bed plate for mounting pump and motor fabricated of mild steel channel as per manufacturer's recommendation with 4 Nos heavy duty Anti Vibration pads. (d) Coupling and coupling guard for direct coupling of pump and motor.
Supplying, installing, testing & commissioning of Diesel Engine driven fire pump suitable for automatic/manual operations consisting of the following:- (a) Horizontal mounted end suction type fire pump having cast iron body, bronze impeller, stainless steel shaft & capable of delivering 2850 LPM against a total head of 70 metre while running at 1800 RPM. (b) Radiator cooled diesel engine of suitable BHP at 1800 RPM for the above pump with standard accessories and suitable cooling system as described in specifications. (c) Common base plate for mounting pump & engine of requisite strength manufactured out of M.S. channels as per manufacturers recommendation with 6 Nos. heavy duty Anti Vibration pads. (Cushy foot). (d) Coupling & coupling guard for direct coupling of engine & pump. (e) 200 liters capacity day oil storage tank fabricated from 16 SWG thick M.S. plates. Tank shall be provided with inlet, outlet, overflow, vent, drain connections, filling connection & level indicator. Tank shall be mounted on a suitable steel structure (Painted with 2 coats of red oxide paint). Tank shall be provided with epoxy coat from inside & two or more coats of synthetic enamel paint outside over two coats of red oxide primer. (f) 24 volts 180 AH lead acid battery (12 volts - 2 Nos) with boost/Trickle charger for starting the engine automatically complete as required. (g) Provision for starting of Engine automatically in case of power failure at the time of fire.
Supplying, installing, testing & commissioning of electrically driven Jockey pump suitable for automatic/manual operation consisting of the following:- (a) Horizontal mounted end suction jockey pump having cast iron body, volute bronze impeller, stainless shaft capable of delivering 180 LPM against total head of 70 M while running at 2900 RPM complete in all respect for testing of working of the pumping set as required. (b) Squirrel cage induction motor TEFC type suitable for 415 + 10%V, 3 phase, 50 Hz, AC supply of suitable HP rating for the above pump with synchronous speed of 2900 RPM connected to pump with flexible coupling and coupling guard . (c) Common bed plate for mounting pump and motor fabricated of mild steel channel as per manufacturer's recommendation with 4 Nos.heavy duty anti Vibration pads.(Cushy foot).
Supply, installation, testing and commissioning Terrace pump of 900 LPM capacity at 36 mtrs head pressure not less than 3.5 kg/sq cm at the top most hydrant suitable for fire fighting and conformiong to IS- 12469-1988 complete with totally enclosed drip proof squirrel cage indcation motor with bronz impellers, pressure guage, pressure switch complete to operate on 3 phase, 415 volts, 50 Hz complete including PCC fondation block and making connection with tail / tapper pieces to connect supply and delivery pipes, including pipes and also including fabricated MS common base plate of suitable size coupling guard air vent for casting pessure guages on delivery side and pipe etc.
Supply, installation, testing and commissioning of Pressure switch of approved make for Hydrant pump, jockey pump and Diesel Engine Driven pump including cut off valve and necessary wiring and up to central panel & other material as described in specifications.
Suppy and fix Air cushioning tank (Air vessel ) 250mm dia x 1000mm high with dished top, made of minimum 6mm thick MS Pipe /Plate complete with 20mm dia brass air valve (Ball type), 20mm dia stop valve, pressure gauge with brass stop cock, nipples, tees, elbows and all accessories complete.
Providing, fixing, testing and commissioning of heavy grade MS pipe, IS : 1239 marked with all necessary fittings like tees, elbows, flanges, reducers, gaskets, nuts and bolts etc. welded or screwed joints as required, fixing the pipe with necessary structural supports including preparing exposed mild steel surfaces and applying two coats of synthetic enamel paint (colour code as per fire fighting norms) over a coat of red oxide zinc chrome primer complete all as specified and directed for following bore pipes:- (Location: Plant room).
25 mm dia (Nominal Bore)
32 mm dia (Nominal Bore)
40 mm dia (Nominal Bore)
50 mm dia (Nominal Bore)
65 mm dia (Nominal Bore)
80 mm dia (Nominal Bore)
100 mm dia (Nominal Bore)
150 mm dia (Nominal Bore)
Providing, fixing, testing & commissioning of 200mm bore, 6.35mm wall thickness heavy class MS pipe, IS : 3589 marked with all necessary fittings like tees, elbows, flanges, reducers, gaskets, nuts and bolts etc. welded or screwed joints as required including fixing the pipe with necessary structural supports (for delivery/suction manifold relating to the pumps) including painting of two coats of synthetic enamel paint over one coat of red oxide zinc chrome primer complete all as specified and directed. [Location : Plant room].
Providing, fixing, testing & commissioning of 150 mm dia 6.35 mm wall thickness flanged end gasket 300mm height of Y-type strainer made from MS body with bottom and top removable flanges with nuts, bolts etc having filteration area at least 6 times the cross sectional area of the pipe.
Supply, install, connecting and testing butterfly valve, flanged ended (Wafer Type) IS-13095 marked with stainless steel disc & stem, lever operated, class PN 16 including all jointing materials such as leather gasket, bolts nuts washers etc complete all as specified and directed for following dia pipes :-
150 mm dia
100 mm dia
80 mm dia
65 mm dia
50 mm dia
Supply, install, connecting and testing of cast iron body non return valve, ISI marked (IS 5312), with gun metal working parts, heavy duty, double flanged, including jointing materials i.e rubber gaskets, nuts, bolts etc complete all as specified and directed for following bore pipes:-
150 mm bore
100 mm bore
80 mm bore
65 mm bore
50 mm bore
Providing, fixing, testing & commissioning of 100 mm dia Burden type, Stainless Steel dial type pressure gauge (in Pump Room) including brass isolation valve and pipe having caliberation of 0-15 Kg/cm2.
Providing, fixing, testing & commissioning of 100 mm dia Burden type, Stainless Steel dial type pressure gauge (in Pump Room) including brass isolation valve and pipe having caliberation of 0-10 Kg/cm2.
Providing and fixing exhaust for Diesel engine driven pump fabricated from M. S. pipe class 'C' 150 mm dia including fitting like flanges, bends, reducers, etc. including 50 mm thick fibre wool insulation with aluminium cladding, 21 gauge fixing of silencer connections at engine exhaust, necessary supports, back filling, cutting and making good, bird proof and weather proof flap complete in all respect as directed.
Providing and fixing M.S. structural work fabricated from standard sections, ( ISI Mark MS rounds, angles, channels etc.) including cutting to size, drilling, welding including cost of fasteners, clamps in R.C.C. structural members as directed, including two or more coats of synthetic enamel paints over one coat of red oxide zinc chrome primer after surface preparation including cutting and making good walls.
Supply/Laying / fixing, jointing, testing and commissioning, LT under ground cable 1100 volts grade XLPE insulated & PVC sheathed cable heavy duty armoured, with multistranded aluminium conductor laid in trenches/ ducts/ pipes/fixed on walls/poles complete all as specified and directed of following sizes:-.
3 Core 35 Sqmm
3 Core 95 Sqmm (Note :- Excavation & earth work, GI pipe for laying of cable, sand cushioning, cable protection cover shall be measured and paid for seprately under respective items of the schedule.)
Supply, installation, testing and commissioning of following fire fighting panel suitable for 415 V, 3 phase, 4 wires, 50 Hz power distribution system. The panel shall be free standing, floor mounting, sheet metal enclosed, dust and vermin proof conforming to IP-52, compartmentalized design, fabricated out of 14 SWG sheet steel, painting, earth numbering, danger plate as per specifications and drawings, flush front with Aluminium busbars, separate earth bus bars to be provided throughout the length of the panel. The incoming and outgoing feeder breakers, fuses, indicating lamps etc shall be accommodated in a modular multitier arrangement. The painting shall be done as per relevant IS codes/as specified in the specifications. Adequate size cable alley shall be provided all round the panel and in the back for each cable bending and termination. The panel shall be fabricated by CPRI/TAC/Fire authority approved vendor. The outgoing feeders inside the panel shall be connected through solid bus bars. Flexible cable links shall not be acceptable. Bus bars shall be provided with heat shrinkable sleeves and shall be colour coded. The panels shall be suitable for cable entry from top. The minimum fault rupturing of all incoming and outgoing switches/breakers shall be 35 KA. The panels shall be fabricated after the approval of fabrication drawings.
Supply and Fix 4 core 1.5sqmm, Copper conductor, PVC insulated and round wire armoured control cable with suitable size saddles complete all as specified and directed.
Supply & making end termination with brass double compression glands for the following PVC insulated, PVC sheathed & armoured 1100 V grade Aluminium cable including cost of crimping lugs/ferrules, compression glands, solder, cable sockets, insulation tape etc complete as required for following size cables :-
3 Core 95 Sq.mm.
3 Core 35 Sqmm
Control Cable 4 Core 1.5 Sqmm
M & L for Earth continuity conductor of 25x6mm galvanised iron earth strip fixed to various equipments/ motors/ switchgears supplied by the bidder as per IS:3043 and as required including provision for connection of earthing strip to main earthing pits etc, on wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation, complete all as directed.
FIRE HYDRANT SYSTEM Providing and applying two coat of 4 mm thick 'PYPKOTE' antirust protection including primer and lap of 25 mm on M.S. pipe 150mm bore in trenches or complete including surface preparation coating and wrapping shall be confirm to ISI 10221 including conducting Holiday Test. ( Make :- IWL / STP / Tikitar )
Supplying, Installation, Testing and Commissioning of Water flow switch i/c connection, controls wiring complete as required .
Providing & Fixing S.S. single headed ISI marked oblique pattern hydrant landing valves with 80mm dia flanged inlet & 63 mm dia female outlet complete with gun metal cap and GI chain twist release type plug and all accessories as per IS : 5290-1983 Type A (For internal + external hydrant) complete all as specified and directed.
Providing & Fixing of 63 mm dia 15 m long non-percolating flexible hose (RRL- type A) as per IS : 636. Type A with S.S. male & female instantaneous type coupling (IS 903) (For internal hydrant system) complete all as specified and directed.
Supply and fix 63 mm dia Gun Metal branch pipe with 12.5 mm nozzle confirming to IS 903 complete all as specified and directed.
Providing & Fixing of wall mounting swinging type first aid fire hose reel with drum, hanging bracket, 36.5 Mtr. length x 20 mm dia high pressure hose reel tubing as per IS: 444 with gun metal (GM) shut off nozzle having 5 mm dia orifice. The hose reel shall be conforming to IS : 884-1985. Rate shall include for 25 mm dia M.S. pipe connection from Riser to hose reel, sockets, nipples, elbows and ball valve (25 mm dia). Drum shall be fixed on adjoining wall through anchor fasteners / cement concrete block as and when required (For internal hydrant system) (basement+Gr.fl.) complete all as specified and directed. ( Make :- MEC/NEWAGE/ATASEE/VICTOR)
Providing & Fixing of weather proof standard fire hose cabinet (750 mm x 600 mm x 300 mm deep) for yard hydrants made of 16 SWG powder coated M.S. sheet having single or double opening glazed (4.0 mm thick glass) shutter including necessary locking arrangement by allan key, stove enamelled Fire red finish with " Fire Hose" marked on front, suitable for housing 2 nos. Hose pipe, 1 No. branch pipe & nozzle spanner. (For external hydrant system) complete all as specified and directed. ( Make :- MEC/NEWAGE/ATASEE/VICTOR)
Providing & fixing air release valve of 25 mm dia and 25 mm dia gun metal gate valve with fittings etc. to be installed at risers complete all as specified and directed. (Make :- Kartar / Zoloto/ Beer/
Providing and laying light duty non pressure 300mm dia class NP-3 RCC pipe spigot and socketed, jointed with stiff mixture in the proportion 1:2, for protection of underground hydrant pipe at road crossings including collar pieces and filling inside of pipe with sand complete as required. (Note :- Excavation & earth work shall be measured and paid for seprately under respective items of the schedule.)
Providing and making drainage provision for the wet riser with 50mm dia MS heavy duty pipe, ball valve, fittings etc. as required for maximum length of pipe 2 mtr complete all as specified and directed.
Supplying, Installation, Testing and Commissioning of Pendent Through Type Sprinkler heads UL listed and FM approved complete with fusible glass capsule of 5mm dia suitable for horizontal/pendent type sprinkler's head of 68 degree with powder coated conforming to relevant IS ammended upto date complete etc. as reqd.
Supply, erection, testing and commissioning of fire brigade draw off connection confirming to IS 4038-1986 with 150 mm Non return valve/ strainer incluiding necessary fittings and writing the word by paint FIRE BRIGADE DRAW OFF on the box complete all as specified and directed.
Supply and fix MS Cabinet(Apporx 750mm x 600mm x 450 mm ) to enclose fire brigade inlet connection fabricated from 16 gauge sheet with full front glass door and locking arrangement duly painted and mounted on masonry platform complete all as specified and directed.
Supply, erection, testing and commissioning of THREE WAY fire brigade inlet connection to wet riser system comprising of 3 Nos. 63 mm dia Gun metal Non Return Valve, 1 No. powder coated weather proof standard hose box suitable for accommodating the above components fabricated out of 16 SWG MS sheet with central opening, glazed front incluiding necessary fittings and writing the word by paint FIRE BRIGADE DRAW OFF on the box complete all as specified and directed.
Supply, erection, testing and commissioning of TWO WAY fire brigade inlet connection to wet riser system comprising of 2 No. 63 mm dia Gun metal Non Return Valve, 1 No. powder coated weather proof standard hose box suitable for accommodating the above components fabricated out of 16 SWG MS sheet with central opening, glazed front incluiding necessary fittings and writing the word by paint FIRE BRIGADE DRAW OFF on the box complete all as specified and directed.
Supply and fixing of Stainless Steel flexible Pipe 25mm dia, UL Listed / FM Approved tested up to 10-16 kg /cm2 pressure of length 1000 mm to 1500mm as required and specified.
Supply, installation, testing & commissioning of certified to EN-54 Projected Beam Detector Complete set with required module (100mtrs)• Should be Microprocessor based • Signal strength LED's • Should Provide linear protection • Automatic compensation for signal drift or dirty lens • Minimum Three field adjustable sensitivity settings • Form A alarm and Form B trouble contacts • Calibrated filters shall be vailable to verify sensitivity • Emitter and Receiver type.
Supply, installation, testing & commissioning of certified to EN-54 Addressable Manual Pull Station Addressable integrated design • All metal construction • Single action • Bi-colored status LED indicates Standby and Alarm conditions • Address should be programmable in EEPROM • Address can be programmed when installed.
Supply, installation, testing & commissioning of certified to EN-54 Isolator Base/ Module fully monitored for short circuit Ability to detect short circuit conditions • Design should be for use with analog sensor. • Should have Built-in LED indication upon short circuit condition • Must contain a security locking tab for tamper protectioncertified.
Supply, installation, testing & commissioning of Fire Alarm certified to EN-54 HOOTER red colour, 90 dBA at 10 feet with power supply arrangement complete as required and suitable for wall/ceiling mounting.and as per specifications.
Supply, installation, testing & commissioning of of Addressable Contact Monitor Module certified to EN-54 • Single input contact monitor • Should be programmed to monitor Normally Open (NO) or Normally Closed (NC) contacts • Should operate on Class A or Class B SLC loop complete as required.and as per specifications.
Supply, installation, testing & commissioning of The Supervised addressable Dual relay output / control module shall be certified to EN-54 2A @ 2 4 VDC Power Limited and must be must be addressed from 1 – 127 prior to installation on the SLC loop. Modules using binary jumper or dip switch setting are not acceptable. The device address shall be electrically programmable and stored in EEPROM. A bi-colored LED shall indicate device status. Operation parameters are maintained by the module, and individual communication with the control system during emergency conditions is not requiredcomplete as requiredas per specifications.
Supply, Installation Testing & Commissioning of Active Repeater Panel to be integrated with Fire Alarm Control Panel,larger display Full colour 800 x 480 LCD with resistive touch screen and automatic back-light dimming and the status of any Fire/Fault of Integrated Fire Alarm Panels, Panel should compliant with EN54-2, EN54-4 and Approved by LPCB.
Supply, Installation Testing & Commissioning of microprocessor based Networkable Analogue Addressable Fire Alarm Control Panel. The Panel shall be compliant with EN54-2, EN54-4 and approved by LPCB. The Fire Alarm Control Panel shall have expandable capacity up to 16 loops. The Panel must have Full colour 800 x 480 LCD with resistive touch screen and automatic backlight dimming. The Panel must also have the capability to take Addressable Intelligent Wired and Wireless Devices on same loop. Each loop shall have a capacity of 127 analogue Addressable devices and 127 Base sounders/Base Sounder Beacons. The panel shall have an event log of minimum 10,000 events @ 1 second resolution, Filterable and Printable. The Panel shall have Three access levels. Panel shall support upto 5000 Cause & Effects entries, with upto 20,000 inputs controlling & 20,000 Controlling outputs across the network. The Panel shall have capability for Peer to Peer networking through RS485 network card. The Panel must have 4 inbuilt programmable sounder circuits, each circuit rated at 2.5A.The Panel must have inbuilt 3 programmable inputs and 5 inbuilt programmable relay outputs. The Panel shall have up to sub-addressable 512 programmable Inputs/Outputs via optional RS485 COMMS serially connected expansion cards. The Panel shall have 240 V AC power supply along with automatic Battery Charger. The Panel shall be fully expandable via common plug in loop driver boards. The user shall have a choice of using the panel with 5.25 Amp or 10.25 Amp power supply unit which is inbuilt in the FACP and should be approved to EN54-4. The Panel shall have configurable via USB port to PC or memory stick. The Panel shall have dedicated RS232 serial port for optional printer.
Supply, laying, testing and commissioning of cable for fire detection and alarm sysrem with 1.5 Sq.mm 2 core annealed tinned multi strand copper conductor PVC Insulated flexible FRLS wire in MS conduit as required. Note : MS conduit shall be measured and paid separately under respective item of BOQ.
Providing and fixing of 16 Gauge MS Conduit in size 20mm dia including the cost of junction box bends, elbow, sockets, Tee and GI flexible conduit to connect from ceiling to false ceiling etc, laying in slab including preparing exposed mild steel surfaces and applying two coats of synthetic enamel paint (colour code as per fire fighting norms) over a coat of red oxide zinc chrome primer, cutting chasses and making good or surfaces mounting including all fixing hardware.
FIRE EXTINGUISHERS Providing & fixing of ISI marked (IS: 2878) portable Co2 fire extinguisher of capacity 4.5 kg flat base including valve discharge hose of not less than 10mm dia. meter complete in all respect including initial fill with Co2 gas confirming to IS 307-1966 and filled to filling ratio of not more than 0.367 complete all as specified and directed.
Providing & fixing of ISI marked (IS: 15683) portable AFFF foam type fire extinguisher, Capacity 9 liter complete in all respect complete all as specified and directed.
Providing & fixing of ISI marked (IS: 15683) portable ABC multipurpose mono monioum phosphate powder, nitrogen pressurised type fire extinguisher, Capacity 9 kg complete in all respect complete all as specified and directed.
Providing & fixing of ISI marked (IS: 13886) trolley mounted fire extinguisher, AFFF Mechnical foam type (gas pressurized) Capacity 50 liter complete in all respect complete all as specified and directed.
Providing & fixing of ISI marked (IS: 2878) portable Co2 fire extinguisher of capacity 22.5 kg flat base including valve discharge hose of not less than 10mm dia. meter complete in all respect including initial fill with Co2 gas confirming to IS 307-1966 and filled to filling ratio of not more than 0.367 complete all as specified and directed. ( Make :-Victor/Envos/MEC/Kanex)
PANEL PROTECTION Supply, installation, testing and Commissioning of 4 kg capacity FM 200, DHP Assembly with automatic valve CE & pie approved, push in connector for tube, mounting bracket, end of line adopter and low pressure switch for monitoring system activation complete all as specified and directed.
Supply,Installation,Testing and Commissioning of 6 kg capacity FM 200 , DHP Assembly with automatic valve CE & pie approved, push in connector for tube, mounting bracket, End of Line adopter and low pressure switch for monitoring system activation complete all as specified and directed.
Supply,Installation,Testing and Commissioning of 9 kg capacity FM 200 , DHP Assembly with automatic valve CE & pie approved, push in connector for tube, mounting bracket, End of Line adopter and low pressure switch for monitoring system activation complete all as specified and directed.
Supply,Installation,Testing and Commissioning of Hooter with accessories complete all as specified and directed.
Supply,Installation,Testing and Commissioning of UL Listed Linear Pneumatic heat Detection Tube with all necessary fittings & supports.
EMERGENCY LIGHTING AND EXIT SIGN Emergency Lighting Control Panel (Approved as per BS EN 60598-2-2 by LIA laboratories ltd) with two lighting lines with maximum of 254 devices on both lines, up to 127 devices per line, luminare line length 500/1000 Metres. The System shall work on Extra Low Voltage and shall be Addressable complete all as specied and directed. MAKE : HOCHIKI/ NEPTOLUX/TAMLITE
ELS Panel Transformer 230 V with an output of 35 V AC and is placed between mains and EL2 Control panel. (Approved as per BS EN 60598-2-2 by LIA laboratories ltd) complete all as specied and directed. MAKE : HOCHIKI/NOPTOLUX/TAMLITE
Key pad with an LCD to control, read and configure the Main ELS Control Panel complete all as specied and directed. MAKE : HOCHIKI/NOPTOLUX/TAMLITE
Addressable Exit Signage visible from 20 mtrs (Approved as per BS EN 60598-2-2 by LIA laboratories ltd) with integral battery capacity of 3 hrs and bicoloured LED status indicator. Available in Left,Right,Down signs with Batteries incorporated into each luminaire shall be Polymer Lithium lon technology and incorporate over voltage, over current and deep discharge protection circuitry.Provides at least 3 hours luminaire operation when fully charged (Approved as per BS EN 60598-2-2 by LIA laboratories ltd) complete all as specied and directed. MAKE : HOCHOKI/ NEPTOLUX/ TAMLITE
Addressable Closed Area LED Down lighter (Approved as per BS EN 60598-2-2 with BS EN 60598-1:2008 +A11 by LIA laboratories ltd) with integral battery capacity of 3 hrs and bicoloured LED status indicator complete all as specied and directed. MAKE : HOCHIKI/ NEPTOLUX/ TAMLITE
Addressable Open Area LED Down lighter (Approved as per BS EN 60598-2-2 with BS EN 60598-1:2008 +A11 by LIA laboratories ltd) with integral battery capacity of 3 hrs and bicoloured LED status indicator complete all as specied and directed. MAKE : HOCHIKI/ NEPTOLUX/ TAMLITE
Suppy, fixing & testing of screened and twisted single pair with 1.5 Sq.mm 2 core annealed tinned multi strand copper conductor PVC Insulated flexible FRLS wire in MS conduit as required complete all as specied and directed. (Make :-Polycab / Havalls/Finolex/ RR kabel/ KEI)
AIR CONDITIONING WORKS Supply, installation, Testing and Commissioning of water cooled screw chiller package, having actual capacity not less than 230 TR (2 x 115 TR working + 1x115 TR Standby) at specified design condition. The package shall have single screw compressor to meet total AC requirements. The unit shall mainly comprise of Twin Rotary Screw Compressors, Hermetic/Semi-Hermetic type, Horizontal Screw, lsolation Valves for suction and discharge of compressor water cooled condenser, insulated flooded evaporator, integral refrigerant piping & wiring, accessories as required and called for suction Refrigernat cooled motor, starter panel with wye delta starter automatic and safety control mounted in central console microprocessor panel with BMS compatibility and chiller should have modubus RTU Communication Output compatibility & all mounted on a steel frame complete including chilled water and condenser water pumps and piping, induced draft cooling tower, AHUs, supply and return air ducting, electrical panels/cables and all accessories/items complete as per Annexure 'A' to BOQ, list of drawings and specifications and as per under mentioned notes:- NOTES (a) Minimum techinal parameters/requirement to achieve inside design conditions for room/areas of the auditorium bldg are enclosed as per Annexure 'A' to BOQ, particular specifications and drawings mentioned in list of drawings. (b) Contractor shall check the technical parameters keeping in view the inside design conditions as specified/as per building drawings and if these are found correct and acceptable to achieve the required inside conditions the confirmation to this affect shall be rendered in writing with proof check within 30 days form the acceptance of tender. (c) In case any deviation is observed while checking technical parameters w.r.t. capacity of plant, variation in quantity of items or change in specification to achieve the required specified inside condition, the contractor shall provide complete design data comprising of suitable matching equipments and accessories within 30 days from the date of acceptance of tender to GE in order to obtain approval of Accepting Officer prior to execution of work and these changes shall be implemented by the contractor without any financial effect and amount quoted by the contractor shall be final for the purpose of execution of work.
NOTES FOR CENTRAL AIR CONDITIONING PLANT 1. This is a turn-key job where the responsibility of the contractor will include Design, supply, installation, testing and commissioning of minimum 2 x 115TR, water cooled, scroll chilling machines fitted with hermetically/ semi-hermetically sealed compressors, multi/single circuit chiller, water cooled shell & Tube type condensers, microprocessor based control panel, suitable for R-134 a refrigerant, shell & tube insulated evaporator, expansion device, control mechanism with control cables of appropriate rating and length for interconnecting chiller unit control panel, AHU and Electric control panel suitable capacity for actual cooling capacity The design shall be as per design parameters given in the tender documents and shall include refrigeration unit comprising of compressor, condenser, expansion valve evaporator or chiller and interconnecting refrigerant piping. chilled water pump sets, condenser water pump ,under deck insulation , Air Handling Unit, cooling tower, piping for chilled water , valves, strainers, gauges, ducting arrangement , cables for connection, trays, rubber mat, LT panel, earthing and other connected items required for smooth functioning of plant. 2. The tenderers/bidders shall note that the work of Air Conditioning Plant shall be executed through specialist firm as approved by GE. The following requirements shall also be ensured during execution of the work:- (a) Submission of all documents required according to the contract. (b) Preparation of the design and drawings for all the work within one month of acceptance of tender. The contractors shall be fully responsible for the smooth functioning of the Plant. These designs and drawings, shall be approved by the Accepting Officer. (c) Details of drawings, detailed plant layout with all mechanical and electrical equipments to be installed at various/ different levels at second stage within 10 days from the date of placement of work order. (d) Where specifications for any item of work are not given in MES schedule or particular specifications, specifications as given in relevant Indian Standard or code of practice shall be followed.
NOTES FOR CENTRAL AIR CONDITIONING PLANT (e) Tenderers intention is invited to relevant clauses of particular specification. If any provision not covered under Sch ‘A’, Special conditions, particular specifications but mentioned in relevant clause of SSR Part I (2009) and is required for completion of work then same shall be taken into consideration and no extra cost shall be paid to the contractor on this account and in such event decision of Accepting Officer shall be final and binding. (f) Any damage caused to the installation or any part thereof except for the accepted risks as per condition 48 of IAFW-2249 shall be made good by the contractor under his own arrangement as per the specifications given in the contract without any extra cost to the Government. (g) Accepting officer at his discretion may depute an expert for checking the performance of the Air Conditioning Plant. The contractor shall provide all major repairs/ overhauling etc as per the recommendation of expert and the same shall be notified to the GE immediately on occurrence and no extra shall be paid on this account. (h) The contractor shall ensure that the work is maintained in accordance with the manufacturer’s instructions, procedures and relevant safety codes. (i) The tenderer and the MES as the case may be shall consult with each other and jointly decide on the scheme for protection of the interconnection line(s) and of the facilities at both the ends. All air conditioning equipments installed shall be consistent with the orders of IEM detailed by Accepting Officer. (j) Notwithstanding the provisions of this agreement, the MES will not be responsible for any damage that may occur to the tenderer with the MES system. (k) Charges shall be borne by the contractor for commissioning, testing as well as routine checking. Notwithstanding such checking/ verification in any event, the MES shall not be responsible for any damage caused to the tenderer on account of any mistake in such checking/ verification. (l) All safety measures as per IS provisions and as per laid down procedure of entire Central Air Conditioning Plant shall be the responsibility of the contractor.
NOTES FOR CENTRAL AIR CONDITIONING PLANT (m) The yard sticks to regulate RARs payment against Air Conditioning Plant shall be got approved from CWE by the GE after technical check and following procedure shall be adopted :- (i) Stage wise yardstick %age for the Air Conditioning Plant shall be approved by CWE during currency of work. (ii) Contractor shall submit yard stick for Air Conditioning Plant in duplicate to GE within one month of acceptance of tender, including percentage payment to be made for each stage of theAir Conditioning Plant alongwith supporting details i.e detailed estimate, stage wise abstracts etc. (iii) There may be certain changes in yard stick percentages as submitted by the contractor while approving the yardstick for saidAir Conditioning Plant due to market rates of various materials & due to policy of department of with-holding sufficient amount for later stages of the work in Air Conditioning Plant. Contractor shall not have any claim on this account and percentage payment to be made for each stage as approved by the CWE shall be final & binding on the contractor. (n) Warranty: All the air conditioning equipments shall be warranted against any manufacturing/ design/ installation defects for a minimum period of 5 years from certified date of completion. (o) The consolidated rate for Srl No. 148.00, 148.10, 148.20 & 148.30 shall be quoted against Srl No. 148.00 of BOQ.
SUMMER APPLIANCES Supply and install water cooler electric driven operatable at 230 Volts, single phase, 50 HZ AC electric supply having nominal storage capacity of 120 litres and nominal cooling capacity of 60 litres per hour.
S& F Voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 170 V to 290 V with output voltage stablilized at 230 V with accuracy of + 2.5% and of capacity 3 KVA
AMF PANEL CONROL Supply, installation, testing and commissioning of Plc / logical Controller based amf indoor type lt Panel board suitable for 500 KVA DG set 415 Volts, 3 Phase 4 Wire, 50 Hz AC Supply System confirming to IS:8623/93, Floor mounting along with factory made type panel vermin proof, fully ventilated as per Ip45. The panel shall be front operated - front and rear openable along with all panel accessories hings, rubber gasket, locks with common earth bus at bottom inside panel board with two earth terminal out side panel board ,cable gland plates with independent plate at bottom . The fornt facia shall duly compartmented for each switchgear & control gear, including internally and externally the entire steel surfaces chemically cleaned with Powder coating colour simens grey RAL-7032. All the cover shall be provided with suitable locking arrangements proper gasket. The panel mounted on frame grouted with PCC grounting in PCC 1:3:6, including accommodating the following controls gears , switchgear. complete all as specified and directed by Engineer-in-charge. The make of Panel :- tricolite/ adlec/ dvepl/ Schneider/ l&t. The specified firm can not authorised any other vendor to manufacture panel on their behalf & purchase vouchers from original manufacturer will only be accepted, complete all as specified and comprising the followings :- (a) ACB EF MP WITH UVT & RELEASE 800A FP 50KA- 02 No of L&T/ SCHNEIDER (b) AMF CONTROLLER DIGITAL -01 DEEPSEA/COMAP (c) CONTROL MCB 6A SP 10KA -09 No L&T/SCHNEIDER (d) CT'S 800/5A-03 No AE / L&T (e) INDICATING LAMPS PHASE -09 No RASS / L&T (f) MFM - VAF 415VAC -01 No L&T / SCHNEIDER (g) AUXLIARY RELAYS 2 CO- 06 No SCHNEIDER/SALZER (h) AUTO / MANUAL RELAY 2 CO-02 No RASS/SALZER (j) BATTERY CHARGER AUTOMATIC CHARGER - SMPS 24VDC 10A - 01 No DVEPL / MAHAMAI (k) DC VOLTMETER 0-30VDC - 01 No REP. DC AMPMETER 0-20A -01 REP.
FABRICATION (a) The panel shall be Indoor type and fabricated out of MS CRCA sheet of 1.6mm thick. The size of the front facia shell should not be less than 1800mm x 1400mm x 1000mm, mounted on base frame of angle iron 50 X 50 X 6 mm with 450 mm long legs. BUSBAR (b) The panel shall have Busbar Chamber wih Aluminium bus bar of rating 1200 Amps, three phase and one neutral four wire system fixed on insulator and bus bar insulated by coloured heat shrinkable sleeves. Notes :- (i) The engine and alternator shall be factory assembled in case of M/S Greaves Cotton. In case of M/S Mahindra & Mahindra engine division factory premises and in case of M/S Cummins India at the authorised GOEM for the northern region i.e M/S Sudhir Gen Sets. (ii) Net cut out should be 500KVA after considering due derating factor. (iii) DHPP 'N' will be provided by the contractor for testing of DG Set for 08 Hours continuous testing on full load. (iv) The consolidated rate for Srl No. 151.00, 151.10, 151.20 & 151.30 shall be quoted against Srl No. 151.00 of BOQ.
OPERATING MECHANISM FOR CURTAINS ETC AND STAGE LIGHTING Supply, installation, commissioning and testing motorized mechanism with lowering arrangement unit for rising and lowering curtains of auditorium stage (fornt, rear, central pairing and back pairing, MIC Bars, etc) consisting of gear system, operatable with 1 HP motor with flange arrangement fixed on the flying gallery with runners, pulleys, guide pulleys, bracket, 5mm dia GI wire rope, operation automatic triping systems, relay box with push buttons and indicators on panel board including fixing etc complete all as directed. Note:- Complete curtain set not part of above item and will be provided by under separate arrangement.
Supply, installation, commissioning and testing motorized mechanism with lowering arrangement unit for rising and lowering of curtain, Cinema screen and lighting bars, etc consiting of gear system operatable with 2.0 HP motor with flange arrangement fixed on the flying gallery with runners, pulleys, guide pulleys, bracket, 5mm GI wire rope, operation automatic triping systems, relay box with push buttons and indicators on panel board including fixing etc complete all as directed. Note:- Complete curtain set not part of above item and will be provided by under separate arrangement.
Suppy and fix SITC of 1000W PAR Cans with Lamp, 240 Volt, PAR Sealed Beam light with CRC Sheet metal and aluminium die casting, matt black powder coat finish,color yoke and clamp complete all as directed.
Suppy and fix SITC of profile halogen spotlight with 150mm diameter piano convex lens, 1000W bi-pin halogen lamp, 240V, aluminium ellipsoidal anodized spherical relector, CRC sheet metal body with matt black powder coat finish complete with lamp, GI Hook clamp suitable for 50mm bar, 1m long 2.0 sq.mm 3 core copper flexible cable with 3 pin 15 Amp plug top as required complete all as directed.
Suppy and fix SITC of 1000W PC Lights:- Halogen Plano convex spot light complete with 1000 W Halogen Bi-pin T-11 lamp, spherical anodized reflector, fine proof socket, 150 mm dia imported fresenel lens, bottom sliding knob, yoke, colour frame and suitable clamps complete all as directed.
Suppy and fix SITC of 1000W Fresenel lights with Lamp:- Halogen Fresnel light consisting of 1000 W Halogen Bipin T- 11 lamp,150 mm dia imported fresenel lens, fire proof socket, bottom sliding knob, yoke, colour frame and suitable clamps complete all as directed.
Suppy and fix SITC of halogen Floodlight with 1000W tubular halogen lamp, 240V Aluminum anodized relector, CRC sheet metal body with matt black powder coat finish complete with lamp, GI Hook clamp suitable for 50mm bar, 1m long 2.0 sq.mm 3 core copper flexible cable with 3 pin 15 Amp plug top as required complete all as directed.
Suppy and fix SITC of halogen Floodlight with 500W/1000W tubular halogen lamp, 240V, Aluminum anodized relector, CRC sheet metal body with matt black powder coat finish complete with lamp, GI Hook clamp suitable for 50mm bar, 1m long 2.0 sq.mm 3 core copper flexible cable with 3 pin 15 Amp plug top as required complete all as directed. .
Suppy and fix SITC wall mounted dimmer panel with petch panel capacity of 18 channel, 4 KW each channel total capacity of 72 KW totally compact DMX control and MCBs for each channel input of rated capacity protection with 3 phase and neutral bus bar, each channel indication lamps complete as required. DMX 512 complete all as directed.
Suppy and fix SITC of Mini Pearl 1024 Channels DMX Controller for Professionals DMX 512 Console for Stage Moving Head DJ Lighting, W/Flight Case IMRELAX,1024 DMX channels, 96 fixture, supporting FAT32 USB Memory, 10 scenes and 5 built- in shapes are able to output simultaneously, sliders can be used to output scenes and adjust the intensity of the dimmer channels in the scenes, compatible with the library in Avolite Pearl R20 format and features built-in shape effects of pan/tilt circle, RGB rainbow, beam dimming wave, etc. Including necessary wiring for providing electric connection complete all as directed.
Suppy and fix SITC of LED PAR Light RGBW 162W using 54 Nos. of 3W LEDs, smooth Dimming from 0-100% ; Beam angle die cast PRO- PAR housing, Powercon Mains IN & OUT complete all as directed.
Suppy and fix SITC OF DMX Spliter Voltage: AC 110 to 120 V, 60Hz, 220/230/240 V to 50 Hz. Product features: Group: 1 group 8 DMX signal change. Function signal amplification shaping capabilities extend signal transmission distance. The number of devices to enhance the ability of the data bus access complete all as directed.
OTHER MISC ITEMS S & F Sign boards complete all as specified and as shown on drawing No. TD-182(C) complete all as specified and directed..
S & F chromium plated towel rail 600mm long complete all as specified and directed. (Product Code & Make :- Cat Part No.F 5004103 of make Cera or equivalent model of other makes listed in list of makes).
S & F Brass, Chromium plated connection 15mm size with CP brass nuts on both ends of length 450mm complete all as specified and directed. (Product Code & Make :- Cat Part No.F8070402 of make Cera or equivalent model of other makes listed in list of makes).
S & F Brass, chromium plated 32mm size bottle trap (with internal partition) with 300mm & 190mm long wall connection pipes & wall flange complete all as specified and directed. (Product Code & Make :- Cat Part No.F 8060403 of make Cera or equivalent model of other makes listed in list of makes).
S & F 15mm bore stop valve cast copper alloy chromium plated, fancy type, extra heavy duty, screwed down high pressure long shank and cup concealed type with crutch or butterfly handle screwed both ends for iron pipe or for union complete all as specified and directed. (Product Code & Make :- Cat Part No.F 3002361 of make Cera or equivalent model of other makes listed in list of makes).
S & F cast copper alloy chromium plated, shower arm 20mm dia and 300mm long round complete all as specified and directed (Product Code & Make :- Cat Part No.F 7040104 of make Cera or equivalent model of other makes listed in list of makes).
S & F cast copper alloy chromium plated, overhead shower 125mm dia round shape complete all as specified and directed (Product Code & Make :- Cat Part No.F 7020306 of make Cera or equivalent model of other makes listed in list of makes).
S & F cast copper alloy chromium plated, long body bib cock with wall flange 15mm bore complete all as specified and directed (Product Code & Make :- Cat Part No.F 5004103 of make Cera or equivalent model of other makes listed in list of makes).
S & F Toilet paper roll holder with flap complete all as specified and directed (Product Code & Make :- Cat Part No.F 5002110 of make Cera or equivalent model of other makes listed in list of makes).
S & F Sensor hand drier complete all as specified and directed (Product Code & Make :- Cat Part No.F BSD-18 of make Prayag or equivalent model of other makes listed in list of makes).
S & F Soap niche complete all as specified and directed (Product Code & Make :- Cat Part No.F 5006106 of make Prayag or equivalent model of other makes listed in list of makes).
S & F 15mm bore central hole Basin mixture for mixing hot and cold water cast copper alloy chromium plated fancy type with with 450mm braided connection pipe complete all as specified and directed (Product Code & Make :- Cat Part No.F 2002461 of make Cera or equivalent model of other makes listed in list of makes).
Schedule 'A'Section-XV : MANNING AND OPERATION OF AIR CONDITIONING PLANT (PHASE-II)
The period of completion of this Phase is 11 (Eleven) months and date of commencement of work under this phase shall be immediately after certified date of completon of work under Phase-I.
Schedule 'A'Section-XVI : MANNING AND OPERATION OF AIR CONDITIONING PLANT (PHASE-III)
The period of completion of this Phase is 11 (Eleven) months and date of commencement of work under this phase shall be immediately after certified date of completon of work under Phase-II.
Note: For the purpose of arriving at lumpsum amount, the amount of credit sch for buildings and other services i.e Sch 'A' section XIII (i.e Rs 49,600.00 shall be deducted from the total amount arrived.
A S CONSTRUCTION COMPANY
Saru Enterprises Pvt Ltd
NAFREF ENGINEERS PVT LTD
Jeet Construction
HMS Buildcon P Ltd
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.05 MB
Download all tender documents and submit your bid