Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹23.6 CrAccepted-AOC NO 102 2ND FLOOR SHEIK DAWOOD STREET ERODE 638 001 | ERODE | TAMIL NADU | 638001 | ₹23.6 Cr Quoted ₹24.7 Cr | L1 | Accepted-AOC RATE QUOTED BY SAKTHI CONSTRUCTIONS IS LESS |
| 2 | L2₹25.7 CrRejected-Finance LIG 11 997 | ERODE | TAMIL NADU | 638001 | ₹25.7 Cr | L2 | Rejected-Finance lOWEST AMOUNT QUOTED BY SAKTI CONSTRUCTION . HENCE REJECTED |
| Sl No | Description | Qty | Unit | sakthi constructions L1 | SUSHMANITICONSTRUCTIONS L2 |
|---|---|---|---|---|---|
| 1.00CONSTRUCTION OF MULTI LEVEL CAR PARKING AT MRC PARKING IN UDHAGAMANDALAM MUNICIPALITY | |||||
| 1.01 | BORED PILE 500 mm Dia Boring. providing and installing Bored cast-in-situ reinforced cement Concrete Pile of specified diameter and length below the pile cap in cement concrete M 30 (1 cement, 0.75 Coarse sand & 1.5 graded stone aggregate of 20 mm nominal size) to carry a safe working load not less than specified, excluding the cost of steel reinforcement but including Bentonite solution machinery charges labour chargers etc., all complete. (Length of pile for payment shall be measured from bottom the Pile to bottom of the pile cap).Bored Pile 500mm Dia | 6,916 | Rm | 6,346.2 ₹4.4 Cr | 6,120 ₹4.2 Cr |
| 1.02 | Boring, Providing and installing Cast Double under Reamed piles of 300mm diametre and length below pile cap in cement concrete piles with mix M 30 concrete to carry a safe working load not less than than specified, excluding the cost of steel reinforcement but including the Bentonite solution,machinary and labour charges etc., all complete. (Length of pile for payment shall be measured from bottom of pile to the bottom of pile cap).Under Reamed Pile 300mm Dia | 573 | Rm | 2,050 ₹11.7 L | 2,017.16 ₹11.6 L |
| 1.03 | Earth work excavation for foundation in Hard stiff clay, stiff black cotton, hard red earth, shales murram, gravel,stoney earth and earth mixed with small size boulders SS.20B and Sand, silt or other loose soil, wet sand,or silt not under water, light black cotton soil, sandy loam ordinary soil and to full depth as may be directed except in hardrock requiring blasting inclusive of shoring shuttering and baling out water and cleaning and levelling the site etc.,complete 10 cum First Depth (0m to 2m) | 492 | Cum | 175 ₹1.3 L | 168 ₹1.2 L |
| 1.04 | Second Depth (2m to 3m) | 125 | Cum | 680 ₹2.5 L | 650 ₹2.4 L |
| 1.05 | Third Depth (3m to 4m) | 79 | Cum | 519 ₹8.7 L | 495 ₹8.3 L |
| 1.06 | Plinth Beam | 502 | Cum | 8,600 ₹36.5 L | 8,230 ₹35.0 L |
| 1.07 | Supplying and filling in foundation and basement with Well Gravel in layers of not more than 15cm thick well rammed watered and compacted etc., complete complying with standard specification. | 2,285 | Cum | 870 ₹19.6 L | 950 ₹21.4 L |
| 1.08 | Plain Cement Concrete 1:4:8 (one part of cement, four part of Crushed Stone Sand (M- Sand) and eight part of coarse aggregates) using 40mm size ISS HBG metal including cost and conveyance of all materials to site and including for the mixing, laying and labour charges and all incidential charges such as water providing etc., complete as per standard specification | 181 | Cum | 810 ₹15.5 L | 880 ₹16.8 L |
| 1.09 | Supplying and erecting centering for vertical plain/ RCC concrete walls of supply channel, retaining wall etc upto 90Cm height with necessary supports,all cross bracing with mild steel size of 90cm x60 cm and gauge BG 10 stiffened with welded mild steel sheet angles of size 25 mm x25 mm x3mm for bearing laid silver Oak/ Country wood joist of size 7.50 cm x5.0 cm spaced @ about 90 cm C/C and supported by Casurina props of 10 cm to 13 cm spaced @ 75 cm C/C etc,, complete complaying with standered specfications and as directed by the departmental officers. Pilecap and Plinth Beam | 2,325 | Sqm | 1,620 ₹24,300 | 1,765 ₹26,475 |
Updated dates
Tender Value
₹30 Cr
EMD Value
₹30 L
Closing Date
18 Feb 2026, 3:00 pmClosed
COMMISSIONER
UDHAGAMANDALAM MUNICIPALITY
Construction of Multi Level Car Parking at MRC Parking in Udhagamandalam Municipality.
2025_MAWS_633078_1
E2/2913-2025
Open Tender
Civil Works
90 days
UDHAGAMANDALAM MUNICIPALITY
Please refer Tender documents.
3 documents required · 3 mandatory
₹0
₹30 L
UDHAGAMANDALAM MUNICIPALITY
26 Mar 2026
17 Dec 2025
18 Feb 2026
17 Dec 2025
18 Feb 2026
17 Dec 2025
31 Dec 2025
BORED PILE 500 mm Dia Boring. providing and installing Bored cast-in-situ reinforced cement Concrete Pile of specified diameter and length below the pile cap in cement concrete M 30 (1 cement, 0.75 Coarse sand & 1.5 graded stone aggregate of 20 mm nominal size) to carry a safe working load not less than specified, excluding the cost of steel reinforcement but including Bentonite solution machinery charges labour chargers etc., all complete. (Length of pile for payment shall be measured from bottom the Pile to bottom of the pile cap).Bored Pile 500mm Dia
Boring, Providing and installing Cast Double under Reamed piles of 300mm diametre and length below pile cap in cement concrete piles with mix M 30 concrete to carry a safe working load not less than than specified, excluding the cost of steel reinforcement but including the Bentonite solution,machinary and labour charges etc., all complete. (Length of pile for payment shall be measured from bottom of pile to the bottom of pile cap).Under Reamed Pile 300mm Dia
Earth work excavation for foundation in Hard stiff clay, stiff black cotton, hard red earth, shales murram, gravel,stoney earth and earth mixed with small size boulders SS.20B and Sand, silt or other loose soil, wet sand,or silt not under water, light black cotton soil, sandy loam ordinary soil and to full depth as may be directed except in hardrock requiring blasting inclusive of shoring shuttering and baling out water and cleaning and levelling the site etc.,complete 10 cum First Depth (0m to 2m)
Second Depth (2m to 3m)
Third Depth (3m to 4m)
Plinth Beam
Supplying and filling in foundation and basement with Well Gravel in layers of not more than 15cm thick well rammed watered and compacted etc., complete complying with standard specification.
Plain Cement Concrete 1:4:8 (one part of cement, four part of Crushed Stone Sand (M- Sand) and eight part of coarse aggregates) using 40mm size ISS HBG metal including cost and conveyance of all materials to site and including for the mixing, laying and labour charges and all incidential charges such as water providing etc., complete as per standard specification
Supplying and erecting centering for vertical plain/ RCC concrete walls of supply channel, retaining wall etc upto 90Cm height with necessary supports,all cross bracing with mild steel size of 90cm x60 cm and gauge BG 10 stiffened with welded mild steel sheet angles of size 25 mm x25 mm x3mm for bearing laid silver Oak/ Country wood joist of size 7.50 cm x5.0 cm spaced @ about 90 cm C/C and supported by Casurina props of 10 cm to 13 cm spaced @ 75 cm C/C etc,, complete complaying with standered specfications and as directed by the departmental officers. Pilecap and Plinth Beam
Centering for soffits of RCC slabs of plane surface like lintels, beams ,etc.,including strutting 3m high using mild steel sheets of size 90cm X 60cm X and B.G 10 stiffened with M.S angles of size 25mm X 25mm X 3mm laid over silver Oak (C.W) joists of size 10cm X 6.5cm (spaced at about 90cm c/c )and supported dy casurina props of 10cm to 13cm dia (spaced of 75cm C/C) complying with standard specification and directed - 10 m 2 (P & D)Data 38 Footing Centering
Roof Beam and Roof Slab Centering
Column Centering
Circular Column Centering
Providing and laying in position Standardised Concrete Mix M-25 Grade in accordance with IS 456 - 2000 using 20mm and down graded hard broken granite stone jelly for all RCC items of works with minimum cement contenet of 350Kg/ cum and maximum water cement ratio of 0.55 including admixture (Plasticiser / super plasticiser) in recommended proportions as per IS 9103 to accelerate, related setting of concrete, improve workability without imparing strength and durability with about (5.0cum), 7730Kg of 20mm machine crushed stone jelly and with about (3.3 cum), 5156kg of 10 - 12mm machine crushed stone jelly and with about (4.79cum) 7670 kg of Crushed Stone sand (M- Sand) but excluding cost of reinforcement grill and fabricating charges centering and shuttering but including laying, vibrating with mechanical vibrators, finishing, curing, etc and providing fixtures like fan clamps in the RCC floor / roof slabs wherever necessary without claiming extra cost etc., complete complying with standard specification and as directed by the departmental officers - The Coarse and Fine aggregates to be used should comply with the requiremnents of IS standards. Foundation and Basement
Ground Floor
First Floor
Terrace Floor
Providing and laying in position Standardised Concrete Mix M-30 Grade in accordance with IS 456 - 2000 using 20mm and down graded hard broken granite stone jelly for all RCC items of works with minimum cement contenet of 400Kg/ cum and maximum water cement ratio of 0.45 including admixture (Plasticiser / super plasticiser) in recommended proportions as per IS 9103 to accelerate, related setting of concrete, improve workability without imparing strength and durability with about (5.0cum), 7730Kg of 20mm machine crushed stone jelly and with about (3.3 cum), 5156kg of 10 - 12mm machine crushed stone jelly and with about (4.79cum) 7670 kg of Crushed Stone sand (M- Sand) but excluding cost of reinforcement grill and fabricating charges centering and shuttering but including laying, vibrating with mechanical vibrators, finishing, curing, etc and providing fixtures like fan clamps in the RCC floor / roof slabs wherever necessary without claiming extra cost etc., complete complying with standard specification and as directed by the departmental officers - The Coarse and Fine aggregates to be used should comply with the requiremnents of IS standards. Foundation and Basement
Ground Floor
First Floor
Terrace Floor
Suppling and fabricating and placing in position MS (or) R.T.S. bar for reinforcement to all RCC works as per the design given including cost of steel and binding wire also in all floors.
Refilling with excavated earth other than sand with an initial head load of 100 mts. and depositing the earth as shown by the departmental officers in layers of not more than 15 cm thick well rammed, watered and consolidated etc. complete complying with standard specification
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.36 MB
Tendernotice_2.pdf
PDF • 0.86 MB
BOQ_757491.xls
BOQ • 0.51 MB
Download all tender documents and submit your bid