Subwork-1: Provision of Electronic Interlocking System including outdoor signalling works and Telecom arrangements in connection with the commissioning of additional loop lines and yard remodelling suitable for doubling at Haliyuru (HLV), Ballenahalli (BAHI), and Talaku (THKU), Chikjajur (JRU), Chikjajur Bypass (JRU BYPS) and development of freight terminal at Haliyuru (HLV) in the JRU-BAY section of South Western Railway. Subwork-2: Provision of Electronic Interlocking System including outdoor signalling works and Telecom arrangements in connection with the commissioning of additional loop lines at Harpanahalli (HPHI) station and Amaravathi colony (AVC) reconnecting berthing (FBWP Siding) line in existing yard in AVC-VC section of South Western Railway.
HLV-BAHI-THKU-HPHI-EI-01
HLV-BAHI-THKU-HPHI-EI-01
Open
18 Months
Mysuru, Karnataka
₹0
₹1.4 Cr
11 Jun 2026
11 Jun 2026
22 Jun 2026
Item Breakup - A-SWR SOR 2025
97.00 Lighting Unit Red with current regulator, as per RDSO specification No. RDSO/SPN/199/2010 revision 1.1 or latest.
112.00 Lighting Unit Yellow with current regulator, as per RDSO specification No. RDSO/SPN/199/2010 revision 1.1 or latest.
54.00 Lighting Unit Green with current regulator, as per RDSO specification No. RDSO/SPN/199/2010 revision 1.1 or latest.
155.00 Signal Lighting Unit with current regulator, as per RDSO specification No. RDSO/SPN/153/2011 Rev 4.1 or latest.
50.00 LED Signal Lighting Unit with current regulator, as per RDSO specification No. RDSO/SPN/153/2011 Rev 4.1 or latest.
115.00 Signal Lighting Unit with current regulator, as per RDSO specification No. RDSO/SPN/153/2011 Rev 4.1 or latest.
7.00 Route indicator (LED Single digit) from 1 to 9 & G with white LED (with housing) as per the latest specification.
53.00 140mm dia, 4.6m tall as per latest specification IRS:S 6-81 Rev.3 or latest.
63.00 140mm dia, 3.6m tall as per latest specification IRS:S 6-81 Rev.3 or latest
53.00 and Shoes to suit CLS pole 4.6m, as per latest specification.
63.00 and Shoes to suit CLS pole 3.6m, as per latest specification.
116.00 Signal Pole 140mm dia as per latest specification.
15.00 made of cast iron with necessary inspection as per latest specification.
22.00 made of cast iron with necessary inspection as per latest specification. SWR-CONST-UBL-S AND T/SOUTH WESTERN RLY
67.00 unit assembly as per RDSO Spec. No. RDSO/SPN/194/2006 Rev .2.0 or latest (Terminal box, mounting socket, hood, side flange and fixing bolt & nut, eye bolt, M12 bolt-3 Nos. and Fixing bolt 08 Nos)
49.00 unit assembly as per RDSO Spec. No. RDSO/SPN/ 194/2006 Rev.2.0 or latest (Terminal box, mounting socket, hood, side flange and fixing bolt & nut, eye bolt, M12 bolt-3 Nos. and Fixing bolt 12 Nos)
8.00 unit assembly as per RDSO Spec. No. RDSO/SPN/194/2006 Rev .2.0 or latest (Terminal box, mounting socket, hood, side flange and fixing bolt & nut, eye bolt, M12 bolt-3 Nos. and Fixing bolt 12 Nos)
116.00 foundation as per Drg.No.SG/SWR/052 using metallic templates, for erection of colour light signals up to 4 aspects. [Foundation bolts, cement, river sand, stone jelly of size 20/25mm dia and all other miscellaneous materials required for the work shall be supplied by the Contractor].
116.00 pole, mounting of colour light signal up to 4 aspects complete on Signal pole/ Off-set bracket, (for LED/ filament bulbs) with lenses, triple pole lamp holder, filament switching units, CLS transformer, current regulators (whichever is applicable), fixing of ladder with platform complete and concreting of ladder shoe, fixing of number plates, marker board, lens guard, fixing of speed limit board wherever necessary,termination of tail cables, wiring of signal unit with PVC wire 3/0.75mm copper, provision of EWS locks, and painting of one coat of red oxide and two coats of aluminium/ enamel paints. When the aspect is fixed on Offset bracket using 'U' bolts and nuts, a through bolt shall be provided by drilling a hole in the signal pole to prevent the offset bracket from sliding down. ['U' bolts and nuts, through bolts and nuts, cement, stone jelly 20/25mm dia, river sand, Signal Collar-rings, wire PVC 3/0.75mm copper, lens-guard, all fixing bolts and nuts, lead wool, paints PVC/Nylon sleeves, enameled number plates. enameled marker boards, EWS locks, and all other miscellaneous materials for the work shall be supplied by the Contractor].
74.00 complete as per latest specification. SWR-CONST-UBL-S AND T/SOUTH WESTERN RLY
70.00 bolts and nuts, erection of Calling On Signals/ 'A' marker lights, termination of tail cables and wiring using wire PVC 3/0.75mm copper, provision of EWS lock, number plates/ marker boards and painting. The work also includes drilling suitable holes on the CLS post and provision of a through bolt with nut to prevent the Offset bracket from slipping down. (Supply of Calling On Signal/ 'A' marker light, LED aspects/holders & bulbs and Off set brackets is not covered in this item). ['U' bolts and nuts, through bolts with nut, wire PVC 3/0.75mm copper, EWS lock, Enameled number plates, wire mesh, PVC/Nylon sleeves, paints and all other miscellaneous materials shall be supplied by the contractor].
23.00 complete with hood etc., as per latest specification.
23.00 bolts and nuts, erection of Post type shunt Signal, termination of tail cables and wiring using wire PVC 3/0.75mm copper, provision of EWS lock and painting of one coat of red oxide and two coats of aluminium/ enameled paint. The work also includes drilling suitable holes on the CLS post and provision of a through bolt with nut to prevent the Off-set bracket from slipping down. (Supply of Post type Shunt Signals, LED aspects and Off set brackets is not covered in this item). ['U' bolts and nuts, through bolts with nut, wire PVC 3/0.75mm copper, EWS lock, Enameled number plates, wire mesh, PVC/Nylon sleeves, paints and all other miscellaneous materials shall be supplied by the contractor].
31.00 - complete with surface base, signal pole, hood etc., as per latest specification.
31.00 concrete foundation as per Drg, No.SG/SWR/053 using metallic templates, for erection of Ground type colour light Shunt Signal. [Foundation bolts and nuts, cement, river sand, stone jelly of size 20/25mm and all other miscellaneous materials for the work shall be supplied by the Contractor]. SWR-CONST-UBL-S AND T/SOUTH WESTERN RLY
31.00 signal complete including surface base, signal pole, LED aspects/ lenses, bulbs with holders (whichever is applicable), fixing of lens guards, number plate, termination of tail cables, wiring of signal unit with PVC wire 3/0.75mm copper, provision of EWS locks and painting of one coat of red oxide and two coats of Aluminium/ enamel paint. (Supply of Ground type shunt signal complete including surface base, signal pole, LED aspects, holder, bulbs, and lenses is not covered in this item). [Wire PVC 3/0.75mm copper, lens guards, EWS locks, Enameled number plates, bolts and nuts, lead wool, paints and all other miscellaneous materials shall be supplied by the Contractor].
6.00 indicator - 5 unit arm - 1 way with mounting sockets, as per latest specification.
3.00 indicator - 5 unit arm - 2 way with mounting sockets, as per latest specification.
4.00 indicator - 5 unit arm - 4 way with mounting sockets, as per latest specification.
6.00 Indicators - 1 way complete/ fixing of additional limb to the existing route indicators, termination of tail cables, wiring as per approved circuits diagram using wire PVC3/0.75mm copper, provision of required No of EWS locks, wire mesh, and painting. (Supply of junction type Route Indicators - complete and additional limb is not covered in this item). [3/0.75mm wire PVC, fixing bolts and nuts, EWS locks, wire mesh, PVC/Nylon sleeves, paints and all other miscellaneous materials shall be supplied by the Contractor].
2.00 Indicators - 2 way complete/ fixing of additional limb to the existing route indicators, termination of tail cables, wiring as per approved circuits diagram using wire PVC3/0.75mm copper, provision of required No of EWS locks, wire mesh, and painting. (Supply of junction type Route Indicators - complete and additional limb is not covered in this item). [3/0.75mm wire PVC, fixing bolts and nuts, EWS locks, wire mesh, PVC/Nylon sleeves, paints and all other miscellaneous materials shall be supplied by the Contractor]. SWR-CONST-UBL-S AND T/SOUTH WESTERN RLY
4.00 Indicators - 4 way complete/ fixing of additional limb to the existing route indicators, termination of tail cables, wiring as per approved circuits diagram using wire PVC3/0.75mm copper, provision of required No of EWS locks, wire mesh, and painting. (Supply of junction type Route Indicators - complete and additional limb is not covered in this item). [3/0.75mm wire PVC, fixing bolts and nuts, EWS locks, wire mesh, PVC/Nylon sleeves, paints and all other miscellaneous materials shall be supplied by the Contractor].
10.00 to existing route indicator.
55.00 arrangement for Signals in RE area as per standard practice. The work comprises of providing MS angle frame and wire mesh in order to avoid close proximity of OHE wires. The work also includes provision of earthing wire using 4 SWG GI wires from the screening arrangement up to surface base as per the instructions of Railway representative at site. [All materials required for this work shall be supplied by the Contractor].
8.00 type Goods Warning Board as per practice & SEM (Angle/Rail is to be supplied by Railway).
75.00 type Calling- On/STOP/BSLB/Legend boards as per practice & SEM (Angle/Rail is to be supplied by Railway).
5.00 per required lengths for Various Boards like Goods warning/Calling on/Axle counter & etc (1 PER UNIT= 1 PER TON)
28.00 and fixing of markers of G/P/C/A/IB Markers/Number plates as per IRSEM DRG.No 19-D10 on MS sheet of thickness 3mm. Miscellaneous materials required for fixing is to be supplied by contractor. SWR-CONST-UBL-S AND T/SOUTH WESTERN RLY
13.00 drawal of new tail cables for colour light signals up to 4 aspects with or without route indicator, post type shunt signal and Calling on signals, termination of new tail cables and wiring using wire PVC3/0.75mm copper. This work includes drawal of new tail cables into the signal post duly releasing the existing tail cables from the relevant signals and re-surfacing the earth excavated as instructed by Railway representative at site. [Wire PVC3/0.75mm copper, paints and all other miscellaneous materials shall be supplied by the Contractor]. {Per Unit: Per Cable}
and Existing Colour light Signals complete (upto 4 aspects) with or without Route Indicators, calling on signals, shunt signals etc., carefully without any damage to the gadgets, accounting and stacking them neatly at a place as instructed by Railway representative at site. The work includes breaking the concrete foundation, closing the resultant pit and resurfacing it by ramming and levelling.
10.00 shunt signals along with surface base, signal post etc carefully without any damage, accounting and stacking them neatly at a place as instructed by Railway representative at site. The work also includes breaking and removal of concrete foundation and refilling of the resultant pit by ramming and levelling.
22.00 of STOP board/Warning board/ LEGEND boards along with rails, accounting and stacking them neatly at a place as instructed by Railway representative at site. Also, the resultant pits shall be resurfaced and consolidating by ramming and levelling.
25.00 Signals as per standard practice. The work involves scraping of old paint, applying one coat of Red oxide and two coats of Aluminium/ enamel paint on the Signals - complete as instructed by Railway representative at site. [Aluminium paint, red-oxide and all other miscellaneous materials required for the work shall be supplied by the Contractor]. SWR-CONST-UBL-S AND T/SOUTH WESTERN RLY
4.00 complete, termination of tail cables, wiring as per approved circuit diagram using wire PVC 3/0.75mm & 16/0.2mm copper, provision of EWS - required No's., and painting. (Supply of route indicators is not covered in this item) [Fixing bolts and nuts, EWS locks wires PVC 3/0.75mm & 16/0.2mm copper, wire mesh, PVC/Nylon sleeves, paints and all other miscellaneous materials shall be supplied by the Contractor].
10.00 erection and painting of boards with LEGEND such as "Draw close if signal is at on" at the required places as per the Signalling plan. The work involves concreting of rail post to a size of 600mm x 600mm x 900mm, and fixing the board to the rail using MS clamps, bolts and nuts. (Supply of boards is not covered in this item. Rails of different lengths will be supplied by Railways and the Contractor has to cut them to the required lengths) [Stone jelly of size 20/25mm dia, river sand, cement, M.S.Flats, fixing bolts and nuts, paint and all other miscellaneous materials required for the work shall be supplied by the Contractor]. Total 19078544.00 Item- 2 Chapter-2 Location Box & Associated Items S No. Item No Description of Item Unit Qty Rate Amount
336.00 as per latest specification/drawing.
129.00 as per latest specification/ drawing.
12200.00 25 mm Centre, made up of PBT as per RDSO Specification No. IRS.S.75/2006 (Rev.2) or latest.
1820.00 centre as per RDSO Specification No. IRS.S.75/2006 (Rev.2) or latest.
870.00 blocks as per RDSO Specification No. IRS.S.75/2006 (Rev.2) or latest. SWR-CONST-UBL-S AND T/SOUTH WESTERN RLY
336.00 foundation and erection of Apparatus Case Full size as per Drg. No. SG/SWR/055 and fixing of 2 nos of "E" type locks, one for the front door and another for the back door, fixing of one hard wood shelf plank 37mm thick and painting the apparatus case inside and outside with one coat of red oxide and two coats of aluminium paints, along with painting of termination and equipment particulars on the doors of apparatus cases as per instructions of railway representative at site. (Supply of apparatus case is not included in this item). [ Foundation bolts & nuts, 'E' type locks, cement, river sand, stone jelly of size 20/25mm, hardwood plank of 37mm thick, paints, varnish, fixing bolts & nuts and all other miscellaneous materials required for the work shall be supplied by the contractor].
129.00 foundation and erection of Apparatus Case Half size as per Drg, No.SG/SWR/056, fixing one 'E' type lock for the front door and latching arrangement for the back door, and fixing of one hardwood shelf plank 37mm thick and painting the apparatus case inside and outside with one coat of red- oxide and two coats of aluminium paints. (Supply of apparatus case is not included in this item). [Foundation bolts and nuts, cement, 'E' type locks, river sand, stone jelly of size 20/25mm, 37mm hard wood planks, latching arrangements, paints, varnish, fixing bolts & nuts and all other miscellaneous materials required for the work shall be supplied by the Contractor]
40.00 existing Full location boxes very carefully without damaging the working cables and Shifting and turning the Full location boxes (Apparatus Cases) to clear of the infringement as instructed by the Railway representative at site. The work includes ensuring the safety of the signaling system, releasing the cable coils to give access for shifting/turning the location boxes. Necessary masonry work and earth work in and around the location boxes to the required level shall be done as instructed by the Railway representative at site. If the existing earth connections to the location boxes are disturbed, the earth wires shall be properly re- connected. [All materials required for the work shall be supplied by the Contractor]. SWR-CONST-UBL-S AND T/SOUTH WESTERN RLY
30.00 existing Half location boxes very carefully without damaging the working cables and Shifting and turning the Half location boxes (Apparatus Cases) to clear of the infringement as instructed by the Railway representative at site. The work includes ensuring the safety of the signaling system, releasing the cable coils to give access for shifting/turning the location boxes. Necessary masonry work and earth work in and around the location boxes to the required level shall be done as instructed by the Railway representative at site. If the existing earth connections to the location boxes are disturbed, the earth wires shall be properly re- connected. [All materials required for the work shall be supplied by the Contractor]. SWR-CONST-UBL-S AND T/SOUTH WESTERN RLY
52600.00 and power cables on25/60mm PBT terminals on phenolic sheet and internal wiring on terminal in new apparatus cases, cable termination boxes and in gate lodges excluding cable termination rack at relay room. The work includes fixing of all new cables by teakwood clamp on teakwood base plank, fixing of phenolic synthetic industrial fiber base fine waves cotton fiber board 6mm thick for terminal board to suit each apparatus case, varnishing all teakwood items, fixing of terminals/ fuse blocks on the terminal board, drilling of necessary holes, termination of cables, wiring, identification of cables using aluminium tags with letters punched neatly, as per approved circuit diagram and cable plan painting of particulars on sleeves and also on the inner side of the doors of apparatus case. After terminations are over, the side openings of apparatus case foundation shall be closed with brick work, cement plastered, the inter space filled with sand up to base level and the bottom surface shall be sealed with sealing compound. (Supply of PBT terminals and fuse blocks is not covered in this item). { cement, teakwood cable clamp 50mmX 50mm, base planks 100mm x 25mm, phenolic synthetic industrial fiber base fine weave cotton fiber sheet - 6mm thick to IS specification 2036 -1995 - type F5, PVC / Nylon sleeves , varnish, paints, bolts, nuts, and washers, non-deteriorating type of fuses of various capacities, Aluminium cable tags, sealing compound, country bricks 220mm X 100mm X 60mm, copper bus bars, brass screw, river sand, wire PVC 3/0.75mm copper and other miscellaneous materials shall be supplied by the contractor) SWR-CONST-UBL-S AND T/SOUTH WESTERN RLY
860.00 and power cables on PBT fuse block on phenolic sheet and internal wiring on fuse blocks in new apparatus cases, cable termination boxes and in gate lodges excluding cable termination rack at relay room. The work includes fixing of all new cables by teakwood clamp on teakwood base plank, fixing of phenolic synthetic industrial fiber base fine waves cotton fiber board 6mm thick for terminal board to suit each apparatus case, varnishing all teakwood items, fixing of terminals/ fuse blocks on the terminal board, drilling of necessary holes, termination of cables, wiring, identification of cables using aluminium tags with letters punched neatly, as per approved circuit diagram and cable plan painting of particulars on sleeves and also on the inner side of the doors of apparatus case. After terminations are over, the side openings of apparatus case foundation shall be closed with brick work, cement plastered, the inter space filled with sand up to base level and the bottom surface shall be sealed with sealing compound. (Supply of PBT terminals and fuse blocks is not covered in this item). ( cement, teakwood cable clamp 50mmX 50mm, base planks 100mm x 25mm, phenolic synthetic industrial fiber base fine weave cotton fiber sheet - 6mm thick to IS specification 2036 -1995 - type F5, PVC / Nylon sleeves , varnish, paints, bolts, nuts, and washers, non-deteriorating type of fuses of various capacities, Aluminium cable tags, sealing compound, country bricks 220mm X 100mm X 60mm, copper bus bars, brass screw, sand, wire PVC 3/0.75mm copper and other miscellaneous materials shall be supplied by the contractor) SWR-CONST-UBL-S AND T/SOUTH WESTERN RLY
2150.00 and power cables of Cables on 25/60mm PBT terminals and internal wiring by fixing additional terminals on the Existing terminal boards of apparatus cases, cable termination boxes etc. The work includes fixing of all new cables by teakwood clamp on teakwood base plank, varnishing all teakwood items, fixing of terminals/ fuse blocks, on the existing terminal boards, drilling of necessary holes, termination of cables, wiring, identification of cables using aluminium tags with letters punched neatly, as per approved circuit diagram and cable plan, painting of particulars on sleeves and also on the inner side of the doors of apparatus cases. After terminations are over, the side openings of apparatus case foundation shall be closed with brick work, cement plastered, the inter-space filled with sand up to base level and the bottom surface shall be sealed with sealing compound. (Supply of PBT terminals and Fuse blocks is not covered in this item). [Cement, teakwood cable clamp 50mm x 50mm, base planks 100mm x 25mm, PVC/Nylon sleeves, varnish, paints, bolts, nuts and washers, Non-deteriorating type of fuses of various capacities, Aluminium cable tags, sealing compound, country bricks 220mm x 100mm x 60mm, copper bus bars, brass screw, sand, wire PVC3/0.75mm copper and other miscellaneous materials shall be supplied by the Contractor]. SWR-CONST-UBL-S AND T/SOUTH WESTERN RLY
500.00 and power cables of Cables on PBT fuse block and internal wiring by fixing additional fuse blocks on the Existing terminal boards of apparatus cases, cable termination boxes etc. The work includes fixing of all new cables by teakwood clamp on teakwood base plank, varnishing all teakwood items, fixing of terminals/ fuse blocks, on the existing terminal boards, drilling of necessary holes, termination of cables, wiring, identification of cables using aluminium tags with letters punched neatly, as per approved circuit diagram and cable plan, painting of particulars on sleeves and also on the inner side of the doors of apparatus cases. After terminations are over, the side openings of apparatus case foundation shall be closed with brick work, cement plastered, the inter-space filled with sand up to base level and the bottom surface shall be sealed with sealing compound. (Supply of PBT terminals and Fuse blocks is not covered in this item). [Cement, teakwood cable clamp 50mm x 50mm, base planks 100mm x 25mm, PVC/Nylon sleeves, varnish, paints, bolts, nuts and washers, Non-deteriorating type of fuses of various capacities, Aluminium cable tags, sealing compound, country bricks 220mm x 100mm x 60mm, copper bus bars, brass screw, sand, wire PVC3/0.75mm copper and other miscellaneous materials shall be supplied by the Contractor].
1700.00 on the existing terminals/ fuse blocks in apparatus cases/ battery boxes/ CT boxes/ cable termination racks as per approved circuit diagram. The terminal particulars to be repainted /corrected on the doors of apparatus cases/ battery boxes/ cable termination boxes and FTOT index board as instructed by Railway representative at site. This work includes closing the opening created for entry of new cables in the apparatus cases with masonry brick work and sealing the bottom of the apparatus cases/ cable termination racks with cable compound. [Paints, wire PVC 3/0.75mm and 16/0.2mm copper, sealing compound, bricks, cement, sand and all other required miscellaneous materials shall be supplied by the contractor]. SWR-CONST-UBL-S AND T/SOUTH WESTERN RLY
89.00 Relay Frames of suitable size to Hold up to 4 relays /plug in type HMU as required by Railways and fixing them in apparatus cases for all types of signal control circuits, LC gate control circuit and Point control circuits, fixing of plug boards, relays, resistors and electrolytic condensers on phenolic synthetic industrial fibre base fine weave cotton fibre sheet - 6mm thick to IS specification 2036 - 1995 - Type F5, wiring and termination as per approved circuit diagram and painting the particulars. (Supply of all types of relays, plug boards, connectors, retaining clips and plug in type HMU is not covered in this item). [Wire PVC copper, 3/0.75mm and 16/0.2mm copper, phenolic synthetic industrial fibre base fine weave cotton fibre sheet - 6mm thick to IS specification 2036 - 1995 - Type F5, for fixing resistors and condensers, MS flats 25mm x 6mm brass bolts and nuts, paints, soldering materials, resistors, condensers and all other miscellaneous materials required for the work shall be supplied by the contractor].
33.00 Relay Frames of suitable size to Hold up to 8 relays /plug in type HMU as required by Railways and fixing them in apparatus cases for all types of signal control circuits, LC gate control circuit and Point control circuits, fixing of plug boards, relays, resistors and electrolytic condensers on phenolic synthetic industrial fibre base fine weave cotton fibre sheet - 6mm thick to IS specification 2036-1995 - Type F5, wiring and termination as per approved circuit diagram and painting the particulars. (Supply of all types of relays, plug boards, connectors, retaining clips and plug in type HMU is not covered in this item ). [Wire PVC copper, 3/0.75mm and 16/0.2mm copper, phenolic synthetic industrial fibre base fine weave cotton fibre sheet - 6mm thick to IS specification 2036 - 1995 - Type F5, for fixing resistors and condensers, MS flats 25mm x 6mm brass bolts and nuts, paints, soldering materials, resistors, condensers and all other miscellaneous materials required for the work shall be supplied by the contractor]. SWR-CONST-UBL-S AND T/SOUTH WESTERN RLY
32.00 Relay Frames of suitable size to Hold up to 12 relays /plug in type HMU as required by Railways and fixing them in apparatus cases for all types of signal control circuits, LC gate control circuit and Point control circuits, fixing of plug boards, relays, resistors and electrolytic condensers on phenolic synthetic industrial fibre base fine weave cotton fibre sheet - 6mm thick to IS specification 2036 - 1995 - Type F5, wiring and termination as per approved circuit diagram and painting the particulars. (Supply of all types of relays, plug boards, connectors, retaining clips and plug in type HMU is not covered in this item). [Wire PVC copper, 3/0.75mm and 16/0.2mm copper, phenolic synthetic industrial fibre base fine weave cotton fibre sheet - 6mm thick to IS specification 2036 - 1995 - Type F5, for fixing resistors and condensers, MS flats 25mm x 6mm brass bolts and nuts, paints, soldering materials, resistors, condensers and all other miscellaneous materials required for the work shall be supplied by the contractor].
2.00 Relay Frames of suitable size to Hold up to 20 relays /plug in type HMU as required by Railways and fixing them in apparatus cases for all types of signal control circuits, LC gate control circuit and Point control circuits, fixing of plug boards, relays, resistors and electrolytic condensers on phenolic synthetic industrial fibre base fine weave cotton fibre sheet - 6mm thick to IS specification 2036 - 1995 - Type F5, wiring and termination as per approved circuit diagram and painting the particulars. (Supply of all types of relays, plug boards, connectors, retaining clips and plug in type HMU is not covered in this item ). [Wire PVC copper, 3/0.75mm and 16/0.2mm copper, phenolic synthetic industrial fibre base fine weave cotton fibre sheet - 6mm thick to IS specification 2036 - 1995 - Type F5, for fixing resistors and condensers, MS flats 25mm x 6mm brass bolts and nuts, paints, soldering materials, resistors, condensers and all other miscellaneous materials required for the work shall be supplied by the contractor]. SWR-CONST-UBL-S AND T/SOUTH WESTERN RLY
60.00 - Full size without disturbing the terminations and equipments inside. The work involves scraping of old paint, applying one coat of Red oxide and two coats of Aluminium paint on the inside and outside the apparatus cases, and painting of termination and equipment particulars on the doors of the apparatus cases, as instructed by Railway representative at site. [Aluminium paint, red-oxide and all other miscellaneous materials required for the work shall be supplied by the Contractor].
50.00 - Half size without disturbing the terminations and equipments inside. The work involves scraping of old paint, applying one coat of Red oxide and two coats of Aluminium paint on the inside and outside the apparatus cases, and painting of termination and equipment particulars on the doors of the apparatus cases, as instructed by Railway representative at site. [Aluminium paint, red-oxide and all other miscellaneous materials required for the work shall be supplied by the Contractor].
30.00 the existing Cable termination boxes, after releasing the base plank, Terminal blocks, Fuse Blocks, Terminal Boards, cut rails, pipes, etc., closing the resultant pits and consolidating it by ramming and levelling. The released materials shall be accounted and stacked neatly at a place as instructed by Railway representative at site.
210.00 Signals, Full/Half location boxes, by carrying out the earth work around the foundation, ramming of the earth, caring out masonry work from bottom of earth work using country stones and cement masonry to prevent the earth from slipping down the bank.
55.00 wiring particulars of functions in the Existing apparatus cases-Full Size, cable termination boxes, etc., on the PVC/ nylon sleeves and painting of new nomenclature on the existing signaling gadgets. This work includes carrying out alterations of particulars on the inner side of the doors of apparatus cases, re-numbering of apparatus cases and cable termination boxes. [Paints and all other miscellaneous materials required for the work shall be supplied by the Contractor]. SWR-CONST-UBL-S AND T/SOUTH WESTERN RLY
50.00 wiring particulars of functions in the Existing apparatus cases- Half Size, cable termination boxes, etc., on the PVC/ nylon sleeves and painting of new nomenclature on the existing signaling gadgets. This work includes carrying out alterations of particulars on the inner side of the doors of apparatus cases, re-numbering of apparatus cases and cable termination boxes. [Paints and all other miscellaneous materials required for the work shall be supplied by the Contractor].
180.00 cases (Full/ Half/ Quartersize) without damage after releasing the shelf planks, Terminal blocks, Fuse Blocks, Terminal Boards, Relays of all types EKTs, Secondary Cells, power equipment's, 'E' type locks, etc., and breaking the concrete foundation. After releasing, the resultant pits are to be closed and consolidated by ramming and levelling. The released materials shall be accounted and stacked at a place as instructed by Railway representative at site.
170.00 providing foundation (a pit of size 400mm x 400mm x 1000mm is to be dig and cement concrete foundation in the pit in the ratio 1:3:6 to be casted) and fixing the frames/doors and E- type lock to the fencing with supplied material. The rail post/angular is to be erected up right in the foundation. All materials are to be arranged and used by the contractor (Rail post / angular /frames /Fencing/ E type locks will be supplied by railway). Cutting of rail post / angular / fencing to the required length, transportation to the site is to be done by the contractor.
earth boxes/signal foundations for a width of 0.5m on all sides, up to a level 150mm below the foundation top. This work includes consolidation of earth by watering and ramming. The earth shall be taken from Railway premises as instructed by Railway representative at site. Total 48589770.00 Item- 3 Chapter-3 Point machines S No. Item No Description of Item Unit Qty Rate Amount SWR-CONST-UBL-S AND T/SOUTH WESTERN RLY
96.00 IRS type 220 mm throw with Lock and detector Slides, Cable termination box and clamp lock arrangement with Ground connection, Insulation's etc. for thick web switch ,confirming to RDSO Specification no IRS:S24- 2025 Revision 3.0 or latest.
17.00 IRS type 143 mm throw with Lock and detector Slides, Cable termination box with suitable ground connections, Insulation's etc. confirming to RDSO Specification no IRS:S24-2025 Revision 3.0 or latest
16.00 type 143 mm and connecting all ground connections including wiring and termination in point machine and inter connections between point machine and CT box through PVC hose pipe with 3/0.75mm and 7/1.40mm copper wire and painting. This work includes provision of insulation to stretcher bars, throw bar lug and "D" bracket wherever required, cutting of notches on the point machines covers to suit crank handle configuration. (Combined type point machine with ground connection, uninsulated stretcher bar, throw bar lug and 'D' brackets will be supplied by Railways. [All types of insulations connected to point work, all type of bolts and nuts, washers spring/flat wire PVC 7/1.4mm copper, PVC hope pipe, paints, PVC/nylon sleeves and all other miscellaneous materials required for the work shall be supplied by the Contractor].
94.00 termination box, wiring, testing and commissioning of IRS High Thrust point Machine 220mm.This includes fixing of point machine on MS plate fixed on sleepers complete with fixing of anti-theft covers, MS termination boxes, ground connections, required insulation, crank handle ward (wherever required) etc. This also include necessary adjustment and smithy work, drilling of holes on tongue rails, supply of all miscellaneous material such as flat, angle, bolt, nuts, pins etc.
and existing Point machines (all types) including ground connections and other accessories available complete without any damage to the gadgets, accounting and stacking them neatly at a place as instructed by Railway representative at site. SWR-CONST-UBL-S AND T/SOUTH WESTERN RLY
117.00 termination box for point machine of size 45cm x 23cm x 12 cm, the termination box to be fabricated out of GI sheet 10SWG. The termination box to be provided with 2 nos. of M.S. angle of size 50x50x6mm of length 1000mm each and GI pipe of 40 mm dia and length of 450mm. The termination box is also provided with teak wood plank of size 25 mm thicknesses for fixing of terminals. Necessary bolts, nuts and screws are to be provided for fabrication of termination box. The termination box is to be painted double coat with approved quality of paint black enamel on to the outside and to be painted with white enamel in to inside of the box (All materials are to be procured by the contractor).
111.00 termination boxes on rails/L-angle and concreting as per RDSO Drawing , drilling of suitable holes in the box, fixing of 2 Nos. of GI pipes 32mm dia and 300mmlong at the bottom with clamp nuts - 12 mm thick, one at the inner side and another at the outer side for each pipe for cable entry and one GI pipe 150mm long 32mm dia for drawal of jumper wires for Point machines etc., fixing of hardwood plank 37mm thick on the bottom, provision of one EWS lock, and painting the boxes inside and outside with one coat of red-oxide and two coats of aluminium paints. (Supply of CT boxes is not covered in this item. Rails of different length shall be supplied by Railways. The contractor shall cut lengthy rails wherever required.) [Cement, iver sand, stone jelly of size20/25mm, paint, varnish, GI Pipes 32mm dia - 300mm long - 2Nos and 150mm long - 1 No., clamp nuts - 12mm thick - 2 Nos. for each pipe, fixing bolts and nuts with washers, EWS locks, paints and all other miscellaneous materials shall be supplied by the Contractor].
22.00 the Existing cable termination boxes, after releasing the base plank, Terminal blocks, Fuse Blocks, Terminal Boards, cut rails, pipes, etc., closing the resultant pits and consolidating it by ramming and levelling. The released materials shall be accounted and stacked neatly at a place as instructed by Railway representative at site. Total 21152790.00 Item- 4 Chapter-4 Track circuits S No. Item No Description of Item Unit Qty Rate Amount SWR-CONST-UBL-S AND T/SOUTH WESTERN RLY
215.00 charger, 110V AC as per latest specification No. IRS :S-89-2013 ver 1.0 or latest. Charger shall be of 10Amp output capacity suitable for charging 80AH battery and No. of Lead acid cells, 2/3/4.
355.00 to RDSO specification No.IRS:S 65:83 version 1.0 or latest specification.
205.00 resistance disk type 0 to 30 ohms as per Drg.No.SA.20161/06/M or latest.
980.00 FRP type with 4 terminals and stumps with necessary inspection as per latest specification/drawing.
600.00 complies to UL Thermistor standard 1434 with rating -2 Amps. SWR-CONST-UBL-S AND T/SOUTH WESTERN RLY
88.00 track circuiting Point zone to suit RE/Non-RE areas as per approved signaling plan using Plug-in type track relays. This work includes provision of double bonding, and parallel jumpers, provision of bond wire clips, provision of track lead connections using 2c X 2.5 sq.mm cable, provision of TLJB boxes 2 Nos. at Relay end, 2 Nos. at Feed end and 2 Nos for parallel jumpers as necessary to suit layouts, for each Track Circuit, and termination of jumpers and tail cables in track lead junction boxes, installation of relays, track feed battery chargers to charge up to 4 cells, track feed resistance, B type choke and secondary cells - 80 AH capacity in apparatus cases and wiring with wire PVC 3/0.75mm copper. The work also includes painting of track Circuit No. with Feed end/ Relay end details on the TLJB boxes. The work also includes provision of insulations for gauge tie plates and nose crossing plates wherever required. (Provision of rail joint insulation is not covered in this item) (Uninsulated gauge type plate and nose crossing plate will be supplied by Railways. Supply of track feed battery charger, B type choke, track relays, uncharged secondary cells (2V - 80AH), TLJB boxes with stumps, 2cX2.5 sq.mm cable, is not covered in this item). [track feed resistance, Gauge tie plate and nose crossing plate insulations, PVC/Nylon bushes for TLJB boxes, PVC sleeves, all types of fixing bolts and nuts with spring and flat washers, teakwood stand for fixing track feed resistance, GI bond wire 8 SWG, Channel bond pins, bond wire clips, paints and all other miscellaneous materials shall be supplied by the contractor. Secondary cells-80 AH capacity shall be charged by the contractor through reputed charging agencies]. SWR-CONST-UBL-S AND T/SOUTH WESTERN RLY
106.00 track circuit in Other than Point zone to suit RE/Non-RE areas as per approved signaling plan using Plug- in type track relays. This work includes provision of double bonding, and parallel jumpers, provision of bond wire clips, provision of track lead connections using 2c X 2.5 sq.mm cable, provision of TLJB boxes 2 Nos. at Relay end, 2 Nos. at Feed end and 2 Nos for parallel jumpers as necessary to suit layouts, for each Track Circuit, and termination of jumpers and tail cables in track lead junction boxes, installation of relays, track feed battery chargers to charge up to 4 cells, track feed resistance, B type choke and secondary cells - 80 AH capacity in apparatus cases and wiring with wire PVC 3/0.75mm copper. The work also includes painting of track Circuit No. with Feed end/ Relay end details on the TLJB boxes. The work also includes provision of insulations for gauge tie plates and nose crossing plates wherever required. (Provision of rail joint insulation is not covered in this item.) (Uninsulated gauge type plate and nose crossing plate will be supplied by Railways. Supply of track feed battery charger, B type choke, track relays, uncharged secondary cells (2V - 80AH), TLJB boxes with stumps, 2cX2.5 sq.mm cable, is not covered in this item). [track feed resistance, Gauge tie plate and nose crossing plate insulations, PVC/Nylon bushes for TLJB boxes, PVC sleeves, all types of fixing bolts and nuts with spring and flat washers, teakwood stand for fixing track feed resistance, GI bond wire 8 SWG, Channel bond pins, bond wire clips, paints and all other miscellaneous materials shall be supplied by the contractor. Secondary cells-80 AH capacity shall be charged by the contractor through reputed charging agencies]. SWR-CONST-UBL-S AND T/SOUTH WESTERN RLY
12.00 at Feed end to suit RE/Non-RE standard as per approved signalling plan. This work includes provision of double bonding and parallel jumpers, provision of bond wire clips, wherever required, shifting of relay end and feed end equipments and re-wiring them, provision of track lead connections wherever necessary using 2c x 2.5 sqmm cable, provision of TLJB boxes and termination of jumpers and tail cables in track lead junction boxes, shifting of Track feed/Track relay set wherever required and wiring with PVC 3/0.75mm copper wire. (Supply of TLJB boxes, 2c x 2.5 sq.mm cable and TLJB boxes with stumps is not covered in the item. Existing Track relays, Track Feed Resistance, Track feed battery chargers, B type Chokes and Charged secondary Cells shall use for this work). [Wire PVC 3/0.75mm, PVC/ Nylon bushes for TLJB boxes, PVC sleeves, all types of bolts and nuts with spring and flat washers, teakwood stand for fixing track feed resistance, GI bond wire 8 SWG, Channel bond pins, bond wire clips, paints and all other miscellaneous materials shall be supplied by the Contractor].
7.00 at Relay end to suit RE/Non-RE standard as per approved signalling plan. This work includes provision of double bonding and parallel jumpers, provision of bond wire clips, wherever required, shifting of relay end and feed end equipments and re-wiring them, provision of track lead connections wherever necessary using 2c x 2.5 sqmm cable, provision of TLJB boxes and termination of jumpers and tail cables in track lead junction boxes, shifting of Track feed/Track relay set wherever required and wiring with PVC 3/0.75mm copper wire. (Supply of TLJB boxes, 2c x 2.5 sq.mm cable and TLJB boxes with stumps is not covered in the item. Existing Track relays, Track Feed Resistance, Track feed battery chargers, B type Chokes and Charged secondary Cells shall use for this work). [Wire PVC 3/0.75mm, PVC/ Nylon bushes for TLJB boxes, PVC sleeves, all types of bolts and nuts with spring and flat washers, teakwood stand for fixing track feed resistance, GI bond wire 8 SWG, Channel bond pins, bond wire clips, paints and all other miscellaneous materials shall be supplied by the Contractor]. SWR-CONST-UBL-S AND T/SOUTH WESTERN RLY
160.00 with stumps and terminals after releasing all the bond wires. The released materials shall be accounted and stacked neatly at a place as instructed by Railway representative at site. Total 6342760.00 Item- 5 Chapter-5 LC Gates and Accessories S No. Item No Description of Item Unit Qty Rate Amount
Transportation, Electrically operated Lifting Barrier set with Hand generator with operating voltage of 110V AC/DC. Each set consisting of 2 Nos. of Lifting Barrier Pedestals, each with 8 contact circuit controllers with top roller type Limit Switches (as per Design given in specification & approved by RDSO) Hand Crank, Electric Motor 110V AC/DC. 2 GI sheet Booms of 32 ft length (4 section of 8 Ft long each) with new octagonal shape as per RDSO drg. No. RDSO/S 11600. - Version 2.0 or latest, without fringes, with 2 stop boards in Trilingual i.e Hindi, English & Regional language and MS Counter weights and 02 nos. of boom supports with Motorized / Solenoid boom locking along with 01 no. of hand Generator cum Control panel to operate 2 barriers of a set with 1 selector switch, 3 buttons and 5 indication lamps, contacts, MCB's and relays
2.00 900mmX 900mmX900mm for pedestal, 400mmX400mmX 600mm for meeting post, fixing of lifting barrier boom, contact makers, termination of cables, wiring and painting as per the instructions of Railway representative at site. (Supply of pedestals, meeting posts, contact maker, electric lifting barriers, rail posts, cranks and 'A' type foundation is not covered in this item). [Concreting materials, bolts and nuts, wire PVC 3/0.75mm copper and all other miscellaneous materials required for the work shall be supplied by the Contractor]. (Unit = Per Boom)
1.00 commissioning of electrical/mechanical lifting barrier as per requirement.
4.00 Rotary type of required ward Nos. with keys, as per specification/ No. IRS S.21/2001 Rev.1.0 or latest. SWR-CONST-UBL-S AND T/SOUTH WESTERN RLY
2.00 Handle Box/Emergency Key Box at Interlocked LC Gates, made of Teak wood with Glass fronted door as per specification. Polishing on all exposed surface and for with EKT inside the box. Micro push switch of suitable make with 2NO+2NC contacts and veeder counter non- reset type and wire them as per the approved circuit diagram. The box should have hinges and pad locking arrangements with one Lock with duplicate keys and key chain with label. (All materials except EKT are to be supplied by the contractors.)
2.00 without crank handle or on suitable fixtures at station/apparatus case, provision of economiser push switch with locking facility, wiring with wire PVC 16/0.2mm copper, provision of teakwood terminal box covered with decolum along with locking facility and painting. (Supply of electric key transmitter and crank handles is not covered in this item). [wire PVC 16/0.2mm copper, wire wound resistance, decolum covered terminal box with locking facility by using 25mm thick teakwood, bolts and nuts, paints, push switches, padlocks and other miscellaneous materials required for this work shall be supplied by the contractor].
2.00 Telephone system with Voice Logger facility as per RDSO Spec No.RDSO/SPN/TC/51/2021 (Rev 1.0) or latest. consist of one master Telephone, 06 slave Telephone with modified surge protection & Line connecting unit and 24 Volt DC power supply unit with MF battery compatible with existing electronic LC Gate Telephone system.
of telephone (master telephone) for LC gate telephone system with Voice Logger facility as per RDSO Spec No.RDSO/SPN/TC/51/2021 (Rev 1.0) or latest
2.00 telephone (slave telephone) for LC Gate telephone System as per RDSO Spec No.RDSO/SPN/TC/51/2021 (Rev 1.0) or latest.
2.00 as per E.Rly/Signal Workshop /HWH's Drg. No. BSA/29/730, BSA/29/731, BSA/29/737. This includes supply of 5 nos 'E' type Lock with Key as per IRS Spec. No. IRS:S-30/64 with Latest Amdt and as per Drg. No. SA-3376/M with latest admt. Ward No. to be decided by the site engineer. 'E' type lock to be fixed on MS Plate as per Site requirement (Gate = LC Gate) SWR-CONST-UBL-S AND T/SOUTH WESTERN RLY
in commissioning of Sliding Barrier Boom Set (one set will consist of two sliding barrier booms, one for either side of track) this include carry out civil masonary work at site like digging of pits for foundations, casting of RCC foundation and fixing of foundation bolts (12 nos. in each site of size 18"x18"x36"). This also include loading, unloading and leading of all the material to site of work from the store of Concerned SSE/Sig/ Incharge (One set at each location) This include complete sliding gate in working order as per instruction of Railway Engineer at site and painting of sliding boom type barrier of LC gate with metallic paint, similar to Asian paint or better .All materials except sliding boom gate & 'E' type lock with key to be supplied by the contractor. (Gate = LC Gate)
2.00 LC gates like SM slide instruments, illuminated diagram board, block counter, termination box, telephones, emergency key box, dismantling of ground lever frame along with all connected lever locks, 'E' type locks, HP locks, breaking and removal of concrete foundation, lock rods with rod roller trestles, complete assembly, cranks, compensators, 'A' type concrete foundation on the rod run, transmission wires single wire/double wire accounting and stocking them neatly at a place as instructed by Railway representative at site. After releasing any holes on the walls/ floor are to be filled with cement mortar and plastered. Total 1510182.00 Item- 6 Chapter-6 Trenching & Cable laying S No. Item No Description of Item Unit Qty Rate Amount
48500.00 kinds of soil except hard rocky areas including clearing of roots of trees, rocks, bushes etc. to a depth of 1.0 Mtrs and to a width of 0.3 Mtrs. (Laying of cables is not included in this item).
2000.00 with 0.3 Mtrs wide base in all types of soil (Normal soil, Hard soil & Black cotton soil) and backfilling after laying of HDPE pipe / OFC cable and 6 quad/PIJF cable etc. at 1200mm & 1000 mm depth respectively as per DrgNo.CORE/S&T/ALD/SK/571/04. Ramming and consolidation of soil in trenches as well as disposal of the soil if any. SWR-CONST-UBL-S AND T/SOUTH WESTERN RLY
15000.00 kinds of soil except hard rocky areas including clearing of roots of trees, rocks, bushes etc. to a depth of 1.0 Mtrs and to a width of 0.5 Mtrs. (Laying of cables is not included in this item).
22200.00 Capping (RCC Duct) of size 700mm Length X 500mm Width X 260mm height & Suitable cover plate of 40mm thickness as per Drg.No.SDO/Cable laying/ 007 (Annexure-10) as detailed in document No. RDSO/SI/G/2010 Ver.1.1 or latest on 'Guidelines on signalling cable laying'.
2200.00 Cable channel of size, Width 240/340 mm, Height 155/230 internal/external, length 1 m produced of polyolefin with Fire protection class k-1 in accordance with DIN-53438 Part II for laying Signalling/Telecom cables, channel attachable to each other with male- female swallow tail connectors and having suitable detachable cover
74.00 Tape colour Orange, width of 250mm (10") by printing with black letters 'Indian Railway Signal/Telecom/OF Cable' on both sides
48500.00 by 0.3m width throughout, with earth after laying of cables, and consolidating the trench by ramming and levelling
16000.00 by 0.5m width throughout, with earth after laying of cables, and consolidating the trench by ramming and levelling
of Polyethylene Pipes (HDPE) of 110 mm Outer Dia, 10 mm Wall Thickness, along with one coupler for every 6 Meters as per latest specification No. IS 4984: 2016 with latest amendments and Material Grade: PE 80.
3700.00 Dia, 10mm thickness along with collars in trenches at places of platform cutting etc and wherever required as per the instruction of site engineer.
1200.00 of not less than 30CMs in rocky terrain, concreting the trench with 150mm thick concrete with 1 cement, 2 sand, 4 grade stone 20mm nominal size. (All the materials are to be supplied by the contractor). SWR-CONST-UBL-S AND T/SOUTH WESTERN RLY
750.00 trench or GI pipe/DWC/HDPE pipe in which cable is already laid to a size of 300x300mm with 1:3:6 mortar. (All the materials required for the work should be supplied by the contractor).
of Metre Signaling/Power/Telecommunication cables as per cable plan in cable trenches, masonry ducts, RCC Pipes, DWC pipes, GI Pipes etc. (Supply of cables is not included in this item).
1100.00 and capping/PVC pipe of minimum 25 mm size or higher as per requirement at site on the wall/floor etc., using bends, coupler and T joints and flexible pipe wherever necessary with fixture in the OFC room from equipment rack to common termination and from OFC room to SM room/ Reservation office / Data logger/FOIS room etc. (All required material for fixing to be arranged by the contractor)
100.00 3.65mm thick as per latest specification.
1150.00 4.5mm thick as per latest specification.
13700.00 of 120/103 mm dia, 2 meter long in already dug cable trenches. The unit of RMT means two split pipes of 1 Mtr each Material shall be supplied as per latest specification RDSO/SPN/204/2011 Ver.1.1 or latest.
of (50/100/150mm dia) for cable laying with offset at both ends and with couplings over RCC Bridges/ Drainage/ Culverts with concrete masonry supports of size 300mm x 300 mm x 300 mm at an interval of 2m. The ends of the pipes shall be closed with brick masonry abutments work so that no cable is exposed, the work shall be carried out as per the instructions of Railway representative at site. (Supply of GI pipes with couplings and laying of cables is not included in this item). [Stone jelly of size 20/25mm, bricks, sand, cement and all other miscellaneous materials required for the work shall be supplied by the Contractor]. SWR-CONST-UBL-S AND T/SOUTH WESTERN RLY
of (50/100/150mm dia) for cable laying with offset at both ends and with couplings over Girder bridges by fixing on suitable MS Clamps at an interval of 2 Mtrs. The ends of the pipes shall be closed with brick masonry abutments work so that no cable is exposed, The work shall be carried out as per the instructions of Railway representative at site. (Supply of GI pipes with couplings and laying of cables is not included in this item). [MS angles, flats, bolts and nuts for manufacturing fixing clamps, bricks, sand, cement and all other miscellaneous required for the work shall be supplied by the Contractor].
of (50/100/150mm dia) for cable laying in Hard rocky area with off sets at both ends duly supported by concrete blocks of size 300mm x 300 mm x 300 mm at an interval of 2m. The ends of the pipes shall be closed with brick masonry abutments work so that no cable is exposed, The work shall be carried out as per the instructions of Railway representative at site. (Supply of GI pipes with couplings and laying of cables is not included in this item). [Stone jelly of size 20/25mm, bricks, sand, cement and all other miscellaneous materials required for the work shall be supplied by the Contractor].
66.00 High Density Polyethylene Duct (PLB-HDPE), 40/33 mm Dia, along with End Cap, End Plug, Cable Sealing Plug and Couplers, as per RDSO/SPN/TC/45/2013 Rev.2 with Amd 3.0 or latest
66.00 mm Dia, in the trenches and in the protective works already provided including in HDD portion and supply pulling of Nylone rope through it at different places as per direction of engineer incharge or site engineer
66.00 Duct, 40/33 mm Dia, as per latest specification.
67.00 PLB HDPE Duct, 40/33mm Dia, by using Blowing machine, providing the sufficient loops in loop/joint chambers and other associated works. SWR-CONST-UBL-S AND T/SOUTH WESTERN RLY
11700.00 without damage of surface road/track using Auger Machine (HDD machine). The bore shall be upto 200 mm dia& shall be done at the depth of minimum 1200 mm from the ground level. The ground level shall be considered ignoring the bank height of the bank of the road. The length of the bore shall be minimum 4 Mtrs long. This includes insertion of different dia DWC-HDPE pipe/GI pipes coupling etc. as per direction of Engineer Incharge. Note:- Pipe Supply is not covered under this item. Contactor shall provide all material required for boring and adequate nos. of labours for proper laying of cables into the bore. Cable shall be laid cautiously so that it should not get damage due to rough handling & pressure on cable.
1550.00 Mtr. for track crossing of cables, laying of DWC/HDPE/RCC pipes with collar/coupling, refilling of trench by ramming and consolidating it as per the instructions of Railway representative at site. During excavation of trench, it has to be ensured that the excavated soil does not mix with the ballast available. The depth of 1m trench shall be from the bottom of sleepers for track crossings. Laying of cables is not included in this item. (Supply of DWC/HDPE/RCC pipes with couplers/ collars is not included in this item).
400.00 Mtr. for road crossing of cables, laying of DWC/HDPE/RCC pipes with collar/ coupling, refilling of trench by ramming and consolidating it and resurfacing it to the original position. Laying of cables is not included in this item. (Supply of DWC/HDPE/RCC pipes with couplers/ collars is not included in this item).
450.00 in parallel at a separation of 8 cms each to a depth of 150 mm and width will be as per site requirement in the platform surfaced/tiled floor for laying cable
880.00 Electronic Cable Route Marker to detect S & T underground Cables with programmable memory for saving the user specific data inside the RFID electronic marker locator during locating the cable up to 5 feet depth. Make:3M, Stanley or similar. SWR-CONST-UBL-S AND T/SOUTH WESTERN RLY
1210.00 DRG.No.SG/SWR/067 or latest guidelines. The lettering on the Cable marker shall be "SIG" / "TELE" / "OFC" as per the instructions of Railway representative at site.
1210.00 of size 300mmX300mm, casting of Concrete foundation of size 300mmX500mmX300mm and Placing of RCC cable markers on top of the foundation and refilling the pit and consolidating it by ramming. The cable markers shall be provided at an interval of 20 Mtrs. within station limits and 50 Mtrs. outside station limits throughout the cable route, diversions and also at every track/road crossing.
205.00 of 1.5mx1.5m and depth as instructed by Railway representative at site, for coiling the cables in rear of relay rooms/ AFTC huts, apparatus cases etc. The work includes coiling the underground cables, and placing closely one layer of country bricks of size approx. 220mm x 100mm x 60mm breadth wise above the cables to cover all the cables in the cable pit, closing and consolidating the pit by ramming and levelling. [Country bricks of size 220mmx100mmx60mm (approximately) shall be supplied by the Contractor].
850.00 depth of 1M or as per site requirement, for identifying the existing cable path without damaging the working cables.
50.00 slabs on the Passenger Platform, trenching to a depth of 0.6m to accommodate the additional cables, replacing the slabs removed after the cables are laid and replastering with cement mortar, refilling the trench by ramming and consolidating it as per the instructions of Railway Representatives at site. (Laying of cables is not included in this item). [Cement, sand and all other miscellaneous materials required for the work shall be supplied by the Contractor].
of Metre Existing/Already laid Signalling/Telecom cables to facilitate engineering construction works.
68.00 using minimum 720P and above HD camera and submit one copy in New removable hard disks (With capacity as per requirement); Two copies in DVD-R. SWR-CONST-UBL-S AND T/SOUTH WESTERN RLY
11.00 Radio detection make Advanced Cable & Pipe Locator equipment with GPS co-ordinates logging facility) - Equipment model or better to be used for the Cable route tracing service RD8100 PDLG or RD8200G - Report in the form of CSV/KML file (soft copy) to be submitted to Customer within 15 days from the date of work completion at site.
1600.00 rocky area/ hard soil including clearing of roots of tree, rocks, bushes etc. to a depth 0.6 m and to a width of 0.5 m and refilling of cable trench of 0.6 m depth by 0.5m width throughout, with earth after laying of cables, and consolidating the trench by ramming and levelling. Laying of cable is not included in this item.
38.00 proposed cable route plan (Quad / OFC cable) and submission for approval of Railway. The details instruction / guide lines regarding joint survey and preparation of cable route plan are given in Tender document. Contractor will submit two copies of prints with soft copy to checking by Railways. If alterations are suggested by Railways, then again two copies of prints will be provided for advance approval after carrying out all the alterations as suggested / proposed by Railways. Tracing will be provided to approval by Railway. All drawings will be prepared in AUTOCAD. It also includes preparation and submission of final cable route plan on 75-micron standard polyester film which includes details of entire section in which quad / OFC cables are laid. Once Railway has approved and signed tracings for cable route plan then contractor will submit 6 (six) sets of photocopies for cable route plan in proper binding form. Total 115949095.00 Item- 7 Chapter-7 Cables S No. Item No Description of Item Unit Qty Rate Amount
600.00 insulated flexible 3-core multi strand 2.5 sqmm as per latest specification No.IS:694:1990
4000.00 outdoor armoured optical fiber cable as per latest specification
1220.00 latest specification.
800.00 Screened Cable, cotton braided or reputed make, suitable for Speakers Total 223960.00 SWR-CONST-UBL-S AND T/SOUTH WESTERN RLY Item- 8 Chapter-8 Relay Room & Associated items S No. Item No Description of Item Unit Qty Rate Amount
38.00 size 880mm x 2 Meters made out of 50mmx50mmx6mm thick MS angle with stainless steel nuts and bolts for fixing of the rack with POWDER COATED and drilling suitable holes to suit hylam sheet and relay frames complete as per standard practice with tripod bases and reel insulators (for K rack, P rack and power rack) and with cable ladder of width 400mm and length of 2 Mtr. The thickness of angle to be 5mm. two angles of 40mmX40mmX5mm to be supplied at both ends and supporting flats of 25mm X5mm.
38.00 suitably concreting tri-pod bases and reel insulators with "J" bolts and nuts. Tripod and other supporting are to be painted in 2 coats with enamel.
1300.00 of not less than 6mm thick and with an insulation to with stand 650V AC, on the floor of relay room etc at places as indicated by railway representative at site.
7.00 glass fronted box of size 300mm x 600mm x 75mm with hooks to keep various keys with description engraved on the tags. [TW Glass fronted box of size 300mmx600mmx 75mm with built in lock, hooks, engraved tags and all other miscellaneous materials required for the work shall be supplied by the Contractor]. SWR-CONST-UBL-S AND T/SOUTH WESTERN RLY
16500.00 and power cables and internal wiring on terminal/ fuse blocks in cable termination Rack at relay room. The work includes fixing of all new cables by teakwood clamp on teakwood base plank, fixing of Hylam sheet 10 mm thick for terminal board, varnishing all teakwood items, fixing of terminals/ fuse blocks on the terminal board, drilling of necessary holes, termination of cables, wiring, identification of cables using aluminium tags with letters punched neatly, as per approved circuit diagram and cable plan, painting of particulars on sleeves. After terminations are over, cable entry at the bottom shall be closed with, cement plastered, the inter- space filled with sand up to base level and the bottom surface shall be sealed with sealing compound. Cable armour to be soldered to earth. (Supply of cable termination racks is not included in this item). [All bolts and nuts with washers, Hylam Sheet 10 mm Thick, cement, sand, stone jelly, Teak wood base, paints and all other miscellaneous materials required for the work shall be supplied by Contractor
25.00 Cable termination racks along with all the terminals, fuse blocks, relays, with jacks, holding clips etc., 50-way boards, terminals, connecting wires, cables etc., carefully without causing any damage, accounting and stacking them neatly at a place as instructed by Railway representative at site. After releasing, the floor shall be levelled and cement plastered.
5.00 panel including base plank, and other gadgets connected very carefully without causing any damage to the panel, accounting and stacking them neatly at a place as instructed by Railway representative at site. The resultant pit in the flooring shall be removed of all cable bits, levelled and cement plastered. SWR-CONST-UBL-S AND T/SOUTH WESTERN RLY
3.00 stations (up to 5 roads) the entire signalling installations jointly with the Railway representative at site at the stations covered under various schedules of the Contract, and ensuring that all the signalling gears are installed and adjusted as per the existing rules. The work also involves supply of required number of bound registers with good quality papers with all updated details of cable meggering, relays, batteries, block joints, route cancellation, relay room key entries, block instrument key, earth resistance etc., and handing over to Railways. (Supply of 'As mades' is not covered in this item).
3.00 stations (with more than 5 roads) the entire signalling installations jointly with the Railway representative at site at the stations covered under various schedules of the Contract, and ensuring that all the signalling gears are installed and adjusted as per the existing rules. The work also involves supply of required number of bound registers with good quality papers with all updated details of cable meggering, relays, batteries, block joints, route cancellation, relay room key entries, block instrument key, earth resistance etc., and handing over to Railways. (Supply of 'As mades' is not covered in this item).
4.00 during non-interlocked working of Signals and Points, such as erection and wiring of temporary relay racks and wiring of relays, SM's slide instruments, wiring alterations in the cable termination rack, apparatus cases, signals, Control panel etc, as per the instructions of Railway representative at site. (Supply of relay rack, relays, and SM slide instrument is not included in this item). [All other miscellaneous materials required for the work shall be supplied by the Contractor].
1270.00 Sun boards of various sizes of various drawings of Power diagram, Relay index chart, Station Rule Diagram, FTOT Particulars, yard layout diagram board etc, with different colours as per instructions of Site In-Charge/Railway Representative. SWR-CONST-UBL-S AND T/SOUTH WESTERN RLY
60.00 tray of thickness 1.5 mm, including top cover for closing, with all required miscellaneous materials for installation. Installation to be carried out as per the instructions of site engineer. MS cable tray including cover should be powder coated with Siemens gray color. -MS cable Tray - 400 * 300.
50.00 Tray of thickness 1.5 mm, including top cover for closing, with all required miscellaneous materials for installation. Installation to be carried out as per the instructions of site engineer. MS Cable Tray including Cover should be powder coated with Siemens Gray Color. - MS Cable Tray - 400 * 150.
20.00 Tray of thickness 1.5 mm, including top cover for closing, with all required miscellaneous materials for installation. Installation to be carried out as per the instructions of site engineer. MS Cable Tray including Cover should be powder coated with Siemens Gray Color. - MS Cable Tray - 250 * 100.
20.00 Tray of thickness 1.5 mm, including top cover for closing, with all required miscellaneous materials for installation. Installation to be carried out as per the instructions of site engineer. MS Cable Tray including Cover should be powder coated with Siemens Gray Color. - MS Cable Tray - 100 * 100.
4.00 Crank Handle Cum Key Lock Relay Box (of MS Sheet) along with LEDs, with approved type push buttons, Wago or similar Disconnecting type Terminal Blocks including DIN rail etc., as per approved drawing. Installation, fixing and wiring of boxes for Key Lock Relays to be carried by Contractor's wiring and fixing material. The work shall be carried as per the instructions of site engineer.
49000.00 conductor disconnecting terminal block for 2.5 sqmm wire termination make: wago/elmex or similar with accessories & taxes. Total 10315483.00 Item- 9 Chapter-9 Electronic Interlocking S No. Item No Description of Item Unit Qty Rate Amount SWR-CONST-UBL-S AND T/SOUTH WESTERN RLY
6.00 10036207.00 Interlocking System (Centralized/Distributed) excluding Panel Processor (Hot Standby) with Signalling functions up to 125 functions as per function table enclosed along with 10% spares for the cards/modules/PCB, connectors/couplers, fuses, all relays, crimp contact, convertors etc. used, tools, manuals and Instruments as per RDSO specification RDSO/SPN /192/2019 ver. 2.0 or RDSO/SPN/ 203/2011 ver. 1.0 or latest. This includes supply of Maintenance VDU 55" 4K Resolution and Maintenance PC (embedded PC) and all types of indoor relays along with point contactor relays (QBCA1) required for points/other indoor purposes. Note: Payment will be made for only vital bit as per function table attached by Railways, no payment will be made for non-Vital bits such as Counter bits, SM key Bits, Read back bits and any potential free contact bits of DC-DC converter or Modem of El.
1375.00 functions in El SYSTEM over and above 125 functions under item No 09_001 along with spares for the cards/modules/PCB, connectors/couplers, fuses, all relays, crimp contact, convertors etc. to the extent of 10% of item no. 090100& 090200.
7.00 Items for end location (Goomty) for Goomty/IBH/ station/IBH/Auto Hut for distributed Auto Hut Architecture in connection with item No. 1 as per Function table enclosed along with 5% Spares, tools, manuals & instruments as per technical specification. (Per Unit= Per Goomty/IBH/ Auto Hut)
6.00 application logic and interface circuit as per the SIP & Table of Control supplied by railway for the station. This includes internal FAT testing prior to submission for approval of circuits.
6.00 commissioning of EI equipments supplied for the station, duly carrying out the required FAT & SAT, including transportation from consignee depot to site at station. This also includes splicing & termination of OFC cable supplied by railways for communication equipment of EI.
of Interlocking system. SWR-CONST-UBL-S AND T/SOUTH WESTERN RLY
of operator VDU of size 55" 4K resolution, with backlit LED, with HDMI/DVI port, Inbuilt Speaker, required HDMI/DVI cables for connectivity and other miscellaneous item required for installation.
12.00 industrial grade computer (Similar to Moxa V2406A or better) with all accessories such as key board, mouse, antivirus etc. of industrial grade as per approved Specification as recommended by RDSO (TAN No. STS/TAN/3007 Version 1.0 or latest).
of construct Maintenance Free Earth as per RDSO Spec No. RDSO/ SPN/197/2016 ver 1.0 or latest and as per technical specification.
13.00 Earth Pit for Ring Earth as per RDSO specification No.RDSO/ SPN/197/ 2016 ver 1.0 or latest as per details given in technical specification.
6.00 fixing of panel operator consol with arrangement to fix 55" VDU's - Reset boxes, and other S&T gadgets. This shall be made of not less than 18mm thick plywood or better materials with storage facility of approved colours with contractors' materials, lead, lift and manpower as per the instructions of engineer in charge and as per the enclosed drawing.
160.00 installation, commissioning, testing, trouble shooting and in diagnosing faults using diagnostic tools/flow charts including supply of necessary documents
110.00 designing, change in the logics and converting it suitable for system and loading the programme into the working system for alteration of SIP/TOC. The training should be comprehensive with complete document.
4.00 Acceptance test for any station having Centralized EI configuration.
2.00 Acceptance test for any station having Distributed EI configuration
of arrangement for Operator/Maintenance VDU and Embedded PC. This consists of a) 110V DC/110V AC, 500VA Inverter - 2 Nos b) 110V DC/24V DC, 10A - 2 Nos. Make: Similar to Gallant, Wago, Phoenix or better. Total 223754977.00 Item- 10 Chapter-10 Relays SWR-CONST-UBL-S AND T/SOUTH WESTERN RLY S No. Item No Description of Item Unit Qty Rate Amount
30.00 Relays, Plug-In-Type, style QN1, 8F/8B Contacts, DC Neutral line Relay, working voltage 24V DC, metal to carbon, with plug board, retaining clip and connectors as per RDSO Specification No BRS:930, IRS: S: 34 & IRS: S: 23, STR: SIQ 0420 Ver.1 or latest. The Interlocking code for this relay shall be ABCDF
380.00 Plug-In-Type style QNA1, 8F/8B Contact, DC Neutral line Relay, working voltage 24V DC, metal to carbon with plug board, retaining clip and connectors as per RDSO Specification No BRS:931A, IRS: S@58<44@ IRS:S:34 & IRS:S:23, STR: SIQ 0420 Ver.1 or latest. The Interlocking code for this relay shall be ABDGH
135.00 type, Style QTA2 - 9 Ohm, 2F-1B Contacts, metal to carbon with plug boards, connectors and retaining clips as per RDSO specification No. BRS:939A & 966(Appx F2) & IRS:S 23-88 Amdt.1, S34 & 60, STR: SIQ 0420 Ver.1 or latest. The interlocking code for this relay shall be FGHKX.
55.00 Plug-in-type, style QBAT -9 Ohms, DC based track Relay, 2F/2B - contacts, Metal to carbon complete with plug board, retaining clip & connectors as per RDSO Specification No. RDSO/SPN/84-88, IRS:S:34 & IRS:S:23. The interlocking code for this unit shall be ABEJX.
10.00 plug in type style QBCA-1, 2HF/4B contacts, DC Biased contractor Relay, Tractive armature, working voltage 24V DC with Heavy duty front contact, Metal to carbon complete with plug board, retaining clips and connectors as per RDSO specification No. BRS 943, IRS. S@46"44@ IRS.S.23
69.00 (KLCR) working on24V DC, AC Immunized with different ward combinations and contact configuration 4F/4Bwith 2 extra ward plates and with case, RDSO spec no. RDSO/SPN/219/2016 ver 1.0 with amendment or latest, confirming to IRS S-23, S-34 & S@45<44@ IRS S:46. Total 4257427.00 Item- 11 Chapter-11 Data Logger &remote Terminal Unit S No. Item No Description of Item Unit Qty Rate Amount SWR-CONST-UBL-S AND T/SOUTH WESTERN RLY
10.00 and commissioning of Datalogger as per RDSO IRS/99/2006 or latest with Power supply arrangement for data logger consists of 12V,42AH VRLA batteries-4 Nos and 10A charger 1 No, EI interface card (Digital interface cards)/ protocol converter, for 1024 digital inputs and 32 analog inputs. This includes supply of all miscellaneous items and software for commissioning of datalogger with E1 networking. (including PC/laptop, printer, mounting table and revolving chair of reputed make)
3.00 and commissioning of Datalogger as per RDSO IRS/99/2006 or latest with Power supply arrangement for data logger consists of 12V,42AH VRLA batteries-4 Nos and 10A charger 1 No, EI interface card (Digital interface cards)/ protocol converter, for 512 digital inputs and 32 analog inputs. This includes supply of all miscellaneous items and software for commissioning of datalogger with E1 networking. (including PC/laptop, printer, mounting table and revolving chair of reputed make).
Validation modification at site (Station)
Validation modification at central place. (Test Room). Total 9630108.00 Item- 12 Chapter-12 Power supply & Associated Items S No. Item No Description of Item Unit Qty Rate Amount SWR-CONST-UBL-S AND T/SOUTH WESTERN RLY
8.00 1520000.00 commissioning of SMPS based Integrated Power Supply (IPS) up to 4 Lines in RE area confirming to RDSO Specification No. RDSO/SPN/ 165/2023 (Ver. 4.0) or latest along with B & C Class SPDs,63 Amps fuse, status monitoring panel. IPS should be supplied with (55+5@61<41@ Nos. of uncharged LMLA Secondary Cells 2V- 200AH/2V-300AH(For RE section 2V/200AH for non RE section 2V/300AH) as one set for one IPS confirming to QA IRS:S-88/2004 Low Maintenance Lead Acid Stationary Secondary Cells For S&T Installations along with 16/25 Sqmm cable for each IPS set is (50 Mtrs Red + 50 Mtrs Black + 50 Mtrs Green) = 150 Mtrs. SPECIAL CONDITIONS:1.Including supply of all the accessories required for installation. The supplier shall take up installation, wiring, testing and commissioning with minimum one- month prior notice period from Railways. 2.All the required cables/ Miscellaneous items like wooden plank, ladder etc. for installation and commissioning shall be supplied as part of the work. 3.Supply, installation, testing and commissioning of SPDs (class B&C) are covered in scope of this work. 4. Contractor should make the power supply arrangements if any required for charging the supplied cells at site. contractor should arrange the industrial grade diluted H2SO4 for the charging of cells. The cells should be charged as per latest specification. SWR-CONST-UBL-S AND T/SOUTH WESTERN RLY
5.00 1604529.00 commissioning of SMPS based Integrated Power Supply (IPS) up to 6 Lines in RE area confirming to RDSO Specification No. RDSO/SPN/ 165/2023 (Ver. 4.0) or latest along with B & C Class SPDs,63 Amps fuse, status monitoring panel. IPS should be supplied with (55+5@61<41@ Nos. of uncharged LMLA Secondary Cells 2V- 200AH/2V-300AH(For RE section 2V/200AH for non RE section 2V/300AH) as one set for one IPS confirming to QA IRS:S-88/2004 Low Maintenance Lead Acid Stationary Secondary Cells For S&T Installations along with 16/25 Sqmm cable for each IPS set is (50 Mtrs Red + 50 Mtrs Black + 50 Mtrs Green) = 150 Mtrs. SPECIAL CONDITIONS:1.Including supply of all the accessories required for installation. The supplier shall take up installation, wiring, testing and commissioning with minimum one- month prior notice period from Railways. 2.All the required cables/ Miscellaneous items like wooden plank, ladder etc. for installation and commissioning shall be supplied as part of the work. 3.Supply, installation, testing and commissioning of SPDs (class B&C) are covered in scope of this work. 4. Contractor should make the power supply arrangements if any required for charging the supplied cells at site. contractor should arrange the industrial grade diluted H2SO4 for the charging of cells. The cells should be charged as per latest specification.
13.00 Distribution Panel for IPS using Hylam sheet 10 mm as per site requirement and erecting it using MS angle clamp 65mm X 65mm X 8mm, HRC fuse block, Mains control switch, ammeter by-pass switch, voltmeter, ammeter, PBT terminals 60mm and wiring the same using wire PVC 7/1.40mm as per approved power diagram. This also includes termination of power cables using teakwood clamp of size 25mm X 60mm X 150mm on a base plank of 25mm thick 150mm width. (MS angles 65mm X 65mm X 8mm, Hylam sheet of 10 mm Thickness, as per site requirement, bolt and nuts required for manufacture of power panel, HRC fuses, box and carriers, teak wood clamp, wire 7/1.40mm, PVC casing and capping and all other miscellaneous materials will be supplied by the contractor, Supply of PBT terminals 60mm is not included in the item). SWR-CONST-UBL-S AND T/SOUTH WESTERN RLY
13.00 of IPS to power distribution panel. This includes transportation of IPS batteries from stores to the site, Erection of IPS panels on teakwood planks, interconnection between panels and wiring the IPS to power distribution panel using 10 sqmm multi-strand copper cable. The wiring should be done neatly using Aluminium ladder with phenolic sheet (Aluminium ladder, phenolic sheet of thickness 6 mm, teak wood plank of width 150 mm and thickness 25mm, 10 sqmm multi- strand copper cable and all other miscellaneous materials to be supplied by the contractor).
13.00 Supply Change over arrangement at SM room. CLS panel of size 800x500x275mm powder coated of MS sheet thickness 1.6mm as per RDSO specification: TI/SPC/PSI/CLS/0025 or latest
1.00 set, including all lifts and leads (Lift arid lead shall be done using suitable hydraulic crane/Fork Lift. The contractor will be responsible for the safe transshipment of the DG set without causing any damages during transportation). The transportation of the DG set over a distance of 80 to 150kms.
1.00 foundations as per Drg No.SG/Proj/SK/DG/01/08 for installation of DG set as per the direction of Site In-charge Railway Representative and Carry out 1st service of the DG set as per the Manufacturer's instructions
1.00 battery stands available in the battery room along with connecting strips, wires and terminal boxes carefully without causing any damage to the batteries, accounting and stacking them neatly at a place as instructed by Railway representative at site. After releasing any holes in the walls/ flooring shall be filled with cement mortar and plastered.
of stationary secondary cells 2V-80AH capacity as per IRS: S 88/2004 Version 1.0 or latest.
3.00 capacity input voltage 160V AC - 280 V AC, output voltage 230V AC, Operating Freq 47-63 Hz with back up time 30 minutes (APC, Emerson or similar make).
250.00 Fuse holders 20 Amps for Railway signalling, voltage 240 AC/DC to Specn. No. IRS S.78/2006. SWR-CONST-UBL-S AND T/SOUTH WESTERN RLY
120.00 Fuse links 20 Amps for Railway signalling, voltage 240 AC/DC to Specn. No. IRS S.78/2006.
70.00 Fuse links 16 Amps for Railway signalling, voltage 240 AC/DC to Specn. No. IRS S.78/2006.
70.00 Fuse links 10 Amps for Railway signalling, voltage 240 AC/DC to Specn. No. IRS S.78/2006.
340.00 Fuse links 6 Amps for Railway signalling, voltage 240 AC/DC to Specn. No. IRS S.78/2006.
420.00 fuse links 2 Amps for Railway signalling, voltage 240 AC/DC to Specn. No. IRS S.78/2006.
5.00 plant (Aqua-Ion Model No. ACAMB 4 Bed Type). Total 25741209.00 Item- 13 Chapter-14 Block Instruments S No. Item No Description of Item Unit Qty Rate Amount
5.00 1486809.00 Interface (UFSBI) complete and Block panel for Single line operation as per RDSO Spec. No. IRS:S- 105/2012 or latest (Per Unit=Set Per Block Section)
2.00 1486673.00 Interface (UFSBI) complete and Block panel for Double line operation as per RDSO Spec. No. IRS:S-105/2012 (Per Unit=Set Per Block Section)
testing commissioning of UFSBI complete and Block panel for Single line/Double line operation as per RDSO Spec. No. IRS:S-105/2012. [All misc items required for commissioning shall be supplied by contractor] (Per Unit=Set Per Block Section)
of changeover of modems working on redundant channels for data transmission on OFC/Quad.
testing commissioning of Automatic Media changeover and modems working on redundant channels for data transmission on OFC/Quad. This included installation & configuration of Industrial grade modem, wrapping of E1 connections etc.
7.00 existing UFSBI system (for use with secondary/backup media i.e. 4-wire OFC VF Channel form station Primary mux or UFSBI E1 modem)
6.00 with UFSBI (as per IRS:S-104/2012)
6.00 with UFSBI (as perIRS:S-104/2012) SWR-CONST-UBL-S AND T/SOUTH WESTERN RLY
6.00 work with UFSBI (as per IRS:S- 104/2012)
6.00 UFSBI (as per-IRS:S-104/2012)
6.00 Converter type Power Supply to work with UFSBI (as per IRS:S- 104/2012)
13.00 Block Counter of Size 550 mm (L) X 350 mm (W) X 850 mm (H) made of Powder Coated MS Sheet of 1.6 mm thickness and two doors fitted with double lock arrangement on front and back side including necessary cable entry arrangements on top and bottom as per the tentative drawing enclosed. Installation to be carried out using Teak Wood Base and necessary grouting as per the instructions of site engineer.
1.00 1232824.00 NO. IRS: S-104/2012 with latest amendment suitable to work on OFC/1 Quad cable for IB signalling, including 68 No.s QN1 relays required for system commissioning.
testing commissioning of Universal Fail- Safe Block Interface as per RDSO Spec No. IRS:S-104/2012 or latest suitable to work OFC/E1/Quad media for IB Signalling [All misc items required for commissioning shall be supplied by contractor]
of Instruments (all types), Block counters, batteries, block filter, block bell equipment etc., carefully without any damage, accounting and stacking them neatly at a place as instructed by Railway representative at site.
9.00 height, 19" rack mountable, 4*E1 uplink, with 4 slots and supporting 8*EM (2W/4W), FXO/FXS and Ethernet card and one slot free for future expansion. Management supporting Telnet as well as NMS. Potential Free contact support. Uplink E1 supporting 4 direction paths as well as 1+1 protection. Unit supports DC (18-72VDC) as well as AC power. Make: MROTEK /CISCO/ MAPLE or similar.
2.00 channels Suitable to be accommodated in Integrated Multiplexer 1U height of MROTEK make or similar.
2.00 channels Suitable to be accommodated in Integrated Multiplexer 1U height of MROTEK make or similar. Total 15930336.00 SWR-CONST-UBL-S AND T/SOUTH WESTERN RLY Item- 14 Chapter-15 ELD,Earthing & Lighting protection System S No. Item No Description of Item Unit Qty Rate Amount
210.00 RDSO Drawing No.SG/SWR/057 and Earthing of metallic sheath and armour of all cables in all apparatus cases, relay room, equipment room, ASM room for block and control, and earthing of all equipment's in apparatus cases, power room, relay rack, cable termination rack, control panel, signals, lever frames with MS of flat 35mm X 6mm or 19c cable (MS flat for closer by areas and MS flat/19c cable combination for farther areas) as per the instructions of Railway representative at site. The work includes painting of earth resistance value on the earth pit. (Supply of 19C cable is not covered in the scope of this schedule). [MS flat for earthing 35mm X 6mm, cement, GI earth electrodes, common salt, charcoal, country bricks, river sand, soldering materials and all other miscellaneous materials required for the work shall be supplied by the Contractor].
210.00 Commissioning of Copper Plate Earthing System complete as per Drg.No.SG/SWR/058 with provision of (i) Copper plate 300 mm X 300mm X 3 mm, (ii) Earth Pit 6 ft depth filled up with charcoal 10 kg & salt 25 kg in alternate layers up to 2 ft from bottom, (iii) Water funnel on Perforated GI pipe of length 4.5 ft., (iv) Cast Iron top plate 12 x 12 (v) Drawing of copper - earth from earth to location with 25 mm x 3 mm copper strip for termination (All miscellaneous materials to be supplied by the contractor).
of construct Unit maintenance free earth as per RDSO spec. No. RDSO/SPN/197 Ver.1.0 or latest. consisting of a) copper bonded steel electrode of 3.0m long, 17.0 mm dia with copper bonding thickness mini 250 micron and UL listed and marked--1 no. b) Earth enhancement compound of RDSO approved brand supplied in sealed bags of min 10 Kgs-03 No. c) Copper strip of 150X25x6mm to terminate earth rod-1 No. d) Copper strip of 300X25x6mm (MEEB)-1 No. e) Copper strip of 150X25x6mm (SEEB)-1 nos
54.00 Free Earth Pit as per RDSO specification No.RDSO/SPN/197 Ver.1.0 or latest and as per Technical Specification SWR-CONST-UBL-S AND T/SOUTH WESTERN RLY
of construct a Maintenance Free Ring Earth with Four Pits (For Interlocked Station, LC Gates/IB Signalling Application) for achieving less than one Ohm as per as per RDSO Spec No. RDSO/SPN/197 Ver.1.0 or latest consisting of a) copper bonded steel electrode of 3.0m long, 17.0 mm dia with copper bonding thickness mini 250 micron and UL listed and marked--4 no. b)Earth enhancement compound of RDSO approved brand supplied in sealed bags of min 10 Kgs-12 No. c) Copper strip of 150X25x6mm to terminate earth rod-4 No. d) Copper strip of 300X25x6mm (MEEB)-4 No. e) Copper strip of 150X25x6mm (SEEB)-4 no's
5.00 Ring Earth with Four Pits (For Interlocked LC Gates/IB Signalling Application) as per RDSO specification No. RDSO/SPN/197 Ver.1.0 or latest and as per Technical Specification.
1000.00 Single Core PVC insulated Copper Cable as per IS: 694 for connecting Main Earth Electrode to MEEB in equipment room. Color: Green.
500.00 Single Core PVC insulated Copper Cable as per IS: 694 for connecting MEEB to SEEB and SPDs to MEEB. Color: Green.
1100.00 Single Core PVC insulated Copper Cable as per IS: 694 for connecting SEEB to all equipment's. Color: Green.
550.00 Cu cable for connecting main earth electrode to equipment room (routing through GI pipe/DWC/HDPE/PVC conduit pipe of suitable size as per site requirement
400.00 sqmm Cu cable between BRC and racks. The work includes mechanical connection by providing two Cu lugs and two steel screws, drilling to two holes and removal of powder coating on rack body, thimbles ties, etc. and routing the same as per site requirements.
490.00 X 3mm for down conductor with all supporting accessories.
490.00 conductor strip 25X3 mm from top of the building to ground level duly securing the same to the building.
300.00 interconnecting earth electrodes. SWR-CONST-UBL-S AND T/SOUTH WESTERN RLY
300.00 interconnecting earth electrodes.
26.00 protection system consisting of Franklin rod of 16mm dia, single prong spike made of copper of length 600mm. Appropriate reducer/coupler for connecting Franklin rod and GI mast, GI mast approximately 1.5-inch dia, 6 mtr length with flanges for installation of franklin rod with all supporting accessories, such as guy rope, U- bolt, thimble, adjustable clamp, D- shakle, hook etc.
of lightening protection system consisting of Franklin rod, appropriate reducer/coupler, flanges and GI mast with all supporting accessories such as guy rope (6 mm GI wire), U-bolt, thimble, adjustable clamp, D-shakle hook, etc.
5.00 arrester of class B and C suitable for single phase supply in TT network as per RDSO spec.no. RDSO/Spn/165/2023 ver 4.0 amd.1 or latest.
5.00 Class B and C arresters as supplied. These din rail mountable devices along with 63 amps HRC input fuse and fuse base shall be fixed in a wall mountable cabinet of size 450 x 250x150 mm made as MS steel of 20 gauge or better with IP31 protection and power coating. All the internal power wiring shall be made by using 10sq.mm cu cable. the PF contract of the class C arrestor shall also be wired using cable thickness of 2,5 sq.mm and terminated on a suitable terminal block.
13.00 12 channel (4 Channels110V AC, 2 Channels- 110V DC, 6 Channels- 24V DC) as per RDSO Spec./256/2002 or latest with 6- digit counter.
8.00 of Earth Leakage Detector 8/12/16 channel. SWR-CONST-UBL-S AND T/SOUTH WESTERN RLY
6.00 location boxes and all signals available at stations (Conventional/MF earthing. (Contractor has to supply/hire the good digital earth tester for recording the measurement. All wire materials/Electrodes required for earth value shall be supplied/made available by contractor). After taking readings contractor has to submit same in three (3) hard copies along with soft copy in excel file). earth values and date of measurement shall be painted on location box/earth pits by the contractor as advised by railway representative.
150.00 various conductors as per requirement.
150.00 weld or similar). Total 15969224.00 Item- 15 Chapter-16 Fire Alarm & Suppression system S No. Item No Description of Item Unit Qty Rate Amount
78.00 commissioning of Heat and smoke multi sensor as per RDSO/SPN/217/2025 ver-3.1 or latest. along with its base, back-box and all accessories incompliance with IS:2175 and IS:11360 standard sand Under writers Laboratory (UL) listed.
78.00 commissioning Fault isolator as per RDSO/SPN/217/2025 ver-3.1 or latest with backbox and all other accessories
1750.00 commissioning of Analogue linear heat sensing (LHS) cable as per RDSO/SPN/217/2025 ver-3.1 or latest
13.00 commissioning of linear heat sensing interface Module as per RDSO/SPN/217/2025 ver-3.1 or latest in compliance with IS standards and Underwriters Laboratory (UL) listed.
904.00 sq.mm unarmoured as per RDSO/SPN/217/2025 ver-3.1 or latest SWR-CONST-UBL-S AND T/SOUTH WESTERN RLY
13.00 commissioning of Networkable single loop addressable Fire alarm Control panel expandable upto 4 loops with GSM interface as per RDSO/SPN/217/2025 ver-3.1 or latest. This work involves supply, fixing, installation and testing of control panel. The control panel shall be networkable to Zonal /Divisional headquarters preferably over TCP/lP and shall have clock synchronization facility. This includes Networking module (TCP/IP) for control panel along with power supply unit and battery set of required capacity for 24 hours backup as per RDSO specification. The panel should support degrade mode operation in compliance with IS: 2189, EN54 standards and Underwriters Laboratory (UL) listed.
13.00 commissioning of Manual call point (resettable) with backbox and all other accessories as per RDSO/SPN/217/2025ver-3.1 or latest
14.00 commissioning of Relay module with backbox and all other accessories as per RDSO/SPN/217/2025 ver-3.1 or latest
14.00 commissioning of Hooter and Visual strobe alarm units with backbox and all other accessories as per RDSO/SPN/217/2025 ver-.3.1 or latest along with its power supply unit.
13.00 commissioning of Control module with backbox and all other accessories as per RDSO/SPN/217/2025 ver-3.1 or latest
13.00 commissioning of EOL as per RDSO/SPN/217/2025 ver-3.1 or latest as directed by the site engineers
13.00 commissioning of Monitor module for 3rd party with backbox and all other accessories as per RDSO/SPN/217/2025 ver-3.1 or latest
1700.00 cables on PVC pipe / capping casing, or cable trays, ladder, shelter etc. as instructed by Railway engineer at site. (Indoor cables to be drawn through pipe, outdoor cables if required to be clamped on wall /floor etc. SWR-CONST-UBL-S AND T/SOUTH WESTERN RLY
26.00 installation, testing and commissioning of CO2 fire extinguisher 6.5 kg capacity conforming to IS15683 with ISI mark provided with all fittings and accessories.
1050.00 sq.mm armoured as per RDSO/SPN/217/2025 ver-3.1 or latest.
13.00 detector. Highly sensitive smoke aspiration system for monitoring of rooms and equipment for earliest possible fire detection For Relay rooms as per RDSO spec No.RDSO/SPN/217/2025 ver3.1or latest.
Programming, Numbers Installation, Testing and Commissioning of Aspiration Smoke detection Supplied.
23.00 Extinguishing of Medium size - the weight of the agent is not less than 1.0 kg but less than 1.8 kg. Total 18087050.00 Item- 16 Chapter-17 Axle counters S No. Item No Description of Item Unit Qty Rate Amount
302.00 (MSDAC): Supply, Design, Detection Installation, Testing and Point (DP) Commissioning of Multi Section Digital Axle Counter (MSDAC) complete system as per RDSO Specification No. RDSO/SPN/176/2013 version.3 with latest amendments STR No. SIQ 0001 Ver.2.0 or latest. MSDAC Reset procedure shall be as per SWR MSDAC Reset policy. Tenderer shall design the scheme for provision of required number of evaluators, reset equipment's, trackside junction boxes, detection points and track clearance relays etc and shall be submitted along with the offer. Remote Diagnostic System shall be provided at station. Length of the cable required for each DP and Rail Type will be specified at the time of issuing call Letter. [This also includes supply of 10% all types of spare cards, LV Boxes, Wheel sensors and other essential modules as specified in RDSO Spec, it shall be rounded to nearest integer subjected minimum of one item. One set of Specialized Tool and Measuring equipment's as per RDSO specifications shall be supplied. (Per Detection Point = DP)
6.00 and maintenance of MSDAC consisting of torque wrench, ratchet, testing plate, measuring tape, screw driver, and gloves and multi meter fluke115 SWR-CONST-UBL-S AND T/SOUTH WESTERN RLY
3.00 field equipment (transmitters coils 2 No. receiver coils 2 No.) on the rails at the entry/exit track circuits without causing any damage. Excavating the under the track for removing track devices, connecting cables and duly covering the cable duct. Disconnecting and removing of Amplifier (electronic junction box and other associated equipment from the location box and transporting to a central location for accountal. Total 117809379.00 Item- 17 Chapter-18 Design & Documents of Signalling Plan S No. Item No Description of Item Unit Qty Rate Amount Design of SIP in Auto Cad. Initially, contractor shall submit 3 copies for approval of Railways. One set will be returned duly approved for making a fair copy or for re- submission for approval after incorporating the changes as required by Railways. After carrying out changes, three Hard copies to be submitted for Railway Approval. After approval, Auto Cad copies to be submitted in USB pen drive along with approved copy in Tracing film and six copies of final approved drawing (Ammonia Print or print as approved by Railway) in properly bound booklet along with its scanned copy.
Set Design of SWRD in Auto Cad. Initially, contractor shall submit 3 copies for approval of Railways. One set will be returned duly approved for making a fair copy or for re-submission for approval after incorporating the changes as required by Railways. After carrying out changes, three Hard copies to be submitted for Railway Approval. After approval, Auto Cad copies to be submitted in USB pen drive along with approved copy in Tracing film and six copies of final approved drawing (Ammonia Print or print as approved by Railway) in properly bound booklet along with its scanned copy.
Set SWR-CONST-UBL-S AND T/SOUTH WESTERN RLY
590.00 based on SIP issued in Auto Cad in A3 size. Initially, contractor shall submit 2 sets of documents for approval of Railways. One set will be returned duly approved for making a fair copy or for re- submission for approval after incorporating the changes as required by Railways. After carrying out changes, two sets of Hard copies to be submitted for Railway Approval. After approval, Auto Cad copies to be submitted in USB pen drive along with approved copy in Tracing film and two sets of final approved drawing in properly bound booklet along its scanned copy.
540.00 based on the approved Signalling Plan as per RDSO Sig DATE Format. AutoCAD in A3 size. Initially, Contractor shall submit 2 set of documents complete for approval of Railways. One set is returned either duly approved for making a fair copy or for re-submission for approval after incorporating the changes as required by railways. The TOC & Preliminary Check and Certification to be done by the IRSE or IRSTE (license holder). After carrying out necessary changes, two set of 'Hardcopies' are submitted for administrative approval. The final corrected drawings shall be supplied to Railways on 80/90 GSM Tracing film and 2 copies of blue print properly bonded booklets and the soft copy in USB Pen drive.
6.00 & approval of Interface Circuits by IRSE/IRSTELO License holders for stations having up-to 25 routes.
6.00 & approval of Logic Circuits of stations of up-to 25 routes by IRSE/ IRSTELO License holders.
365.00 verifying and approval of Interface Circuits / Logic circuits having more than 25 routes by IRSE/ IRSTELO License holders. (Per Unit = Per Route Per Station ) SWR-CONST-UBL-S AND T/SOUTH WESTERN RLY
7.00 Cable Core Plan, Cable Termination Rack Particulars, Location Box Particulars, Power Supply Diagram, Track Circuit Bonding Diagram and/or any other drawing on Auto- CAD in A2/A3/ A4, etc. size (as per instructions of Engineer in-charge). Initially Contractor shall submit 2 sets of 'AS PLANNED' documents complete for approval of Railways. One set is returned either duly approved for making a fair copy or fore-submission for approval after incorporating the changes as required by railways. After preliminary approval, execution of work shall be carried out at site. After Completion of work, 2 sets of AS MADE Check Prints are submitted for administrative approval. Railways will return one set to the contractor duly approved with alterations/corrections if any. The contractor shall incorporate Railways alterations/corrections in the tracings without any deviation and submit all tracings complete in all respect along with its soft copies in USB Pen Drive and 6 sets of final completion drawings in properly bound booklets. [For Centralized Electronic Interlocking Stations/Small Stations]
1250.00 AUTOCAD 2000 or latest (including contact numbers on the circuit) and submission of negatives in 80/90 gsm tracing paper in 'A3' size along with 2 copies and also the soft copy in compact disks induplicate. First, 2 sets of prints shall be supplied to Railways for checking. One set will be returned by Railways to the contractor for making corrections in AUTOCAD. The final corrected drawings shall be supplied to Railways on 80/90 gsm tracing paper and 2 copies of blue prints and the soft copy in 2 CDs. (Approved Signalling plan will be supplied by Railways for preparing table of control. Approved table of control will be supplied by Railways for preparing circuits diagrams). SWR-CONST-UBL-S AND T/SOUTH WESTERN RLY
1350.00 'Asmades' of circuit diagrams, contact analysis charts, termination particulars of apparatus cases and cable termination rack, power supply arrangements, relay index board, cable plans, cable route plans, red boundary plans and all other particulars covered under various schedules. All 'As mades' shall be prepared by the Contractor in AUTOCAD 2000 or latest and submitted in CDs. One copy of the 'As mades' check print shall be submitted before Testing the circuits. The final negatives shall be made in tracing sheet (80 to 90 gsm). All 'As mades' except cable plan, cable route plan, bonding diagram & power supply diagram shall be prepared in A3 size. On approval the contractor shall submit along with the negatives, 8 copies in each, duly making booklet neatly bound. Out of 8 sets, 2 sets of drawings and other plans shall be kept in transparent plastic cover (2 sheets back-to-back in one plastic cover) and handed over to Railways. Also, the contractor has to supply one set of As made in 'Reproduction Film'. The approved circuit diagram will be issued by Railways in soft copy as well as two sets of hard copies. Wherever alterations to existing circuits are involved, the existing as-made circuit diagrams will be supplied by Railways either in CDs or RP film. The Contractor shall incorporate the details of all the new wirings and alterations in the CD/ RP film and submit them to Railways. On approval 8 copies shall be made for As- made circuit diagrams also as mentioned above. SWR-CONST-UBL-S AND T/SOUTH WESTERN RLY
700.00 following Registers with latest proforma given by in-charge officer each register of 100 pages. Station Asset Register/Deficiencies Book/Officer Inspection book/ Work site orientation classes note book /Station Message book/Infringement measure book fog signal gears/Route cancellation register/Relay room Key register/Cable testing summary/Signal maintenance record register/Power Systems Battery maintenance Register/Mechanical Signalling Register/Axle Counter Maintenance Register/Block instrument Maintenance Register/Track circuit maintenance Register/Lifting barriers maintenance Register/Electrically operated point maintenance Register/Electronic interlocking Maintenance Register/Location box maintenance Register/Earth Testing record Register/Relay room register/Joint Inspection of Points and Crossings register/Block Proving Axle Counter Register/Diesel generator /SoIar panel Register (Per Unit = Per Register) Total 7996755.00 Item- 18 Chapter-19 Tools and Measuring Instruments S No. Item No Description of Item Unit Qty Rate Amount
4.00 Held) Brand: RISHABH 18S or similar.
3.00 meter Current measurement upto 200A AC/DC True RMS measurement for AC voltage & current. (Large jaw of size of 18mm) Model: FLUKE 362/Rishabh or higher as per specification.
3.00 measurement set (TMS) suit to RDSO spec IRS:TC:43/87 or latest.
of measuring set to RDSO spec. IRS:TC 45/88 or latest. Make Anuvidyut or better.
4.00 selection of 500V, 100V. Make RISHABH or similar.
4.00 with metal carrying box and auxiliary earthing net Make Wago or better.
4.00 specification. Make: Stanley or similar
4.00 as per specification- Make Stanley or better.
4.00 Recorder) as per latest specification. Make Bosch Model No: 1011662 or better. SWR-CONST-UBL-S AND T/SOUTH WESTERN RLY
5.00 machine with suitable horizontal stand with attachments to drill holes of various sizes up to 7mm to 13mm Make Ralliwolf Model WD 34 C or similar.
of consisting of 1. 3/8" sq Dr Socket 6mm, 2. 1/2"sq Dr Socket 8mm 3. 1/2"sq Dr Socket 18mm, 4. 1/2"sq Dr Socket 19mm 5. 1/2"sq Dr Socket 20mm, 6. 1/2"sq Dr Socket 22mm 7. SP Spanners 10mm, 8. SP Spanners 12mm 9. adjustable Wrench 8" 10. adjustable Wrench 12" 11. 3/8" Sq Dr Ratchet handle 12. 1/2" Sq Dr Ratchet handle 13. T handle 1/2" 14. Short Extension Rod 1/2" 15. Stanley make Water-Proof Medium Nylon Tool Bag 16. Electricians TRMS digital multimeter FLUKE-117 17. MECO Clamp meter 3690 AC/DC 600A 18. Dummy Wheel-1 No Best Indian make electrical hand gloves suitable for 1000V. Make: Friedrich Germany, INSULA or similar.
2.00 type Total 3960939.00 Item- 19 Chapter-20 Provision of Man Power S No. Item No Description of Item Unit Qty Rate Amount
6.00 unskilled staff round the clock to attend to teething trouble of the installation along with SSE/JE(Sig) after the installation has been brought into commissioning. The work includes routine maintenance, failure restoration as per the direction of the SSE/JE(Sig).
150.00 oriented Technical manpower to carryout works like drawing, computation, write up etc., using computer, using software like AUTOCAD, MS Office etc., between 08.00 Hrs and 20.00 Hrs of the day with all expenses of transportation, accommodation, food, consumables etc., with all ascents, descents, taxes, octroi, cess, fees, duties with contractors cost etc., as per special conditional/specifications/ regulations and as directed by Engineer-in-charge. Note: The person engaged for providing the services shall be convergent with computer working knowledge in above software's." SWR-CONST-UBL-S AND T/SOUTH WESTERN RLY
150.00 man power to carry out miscellaneous/sundry works in the office/field between 08.00 hrs and 20.00 hrs of the day and accompanying Railway staff with all expenses of transportation, accommodation, food, consumables etc., with all ascents/descents, taxes, octroi, cess, fess, duties, with contractors tools and plants, materials, consumables, labour, crew, machineries with all lead and lift etc., complete as per special conditions, specification, regulation and as directed by Railway Engineer-in-charge.
180.00 Stores for loading/ unloading/stacking of departmental materials.
280.00 the clock in 12 hours shift beat from Up Home Signal to Down Home Signal to avoid theft of signalling assets. {Per Unit- Per 12 Hours shift} Total 1041284.00 Item- 20 Chapter-21 Quad & OFC Communications Accessories S No. Item No Description of Item Unit Qty Rate Amount
1.00 panel with WAGO/ Pheonix/Elmex make or similar disconnecting Terminals blocks of size1500mm x 500mm x 200mm thickness 1.6mm (16 SWG) 150 numbers of disconnecting terminal block with accessories. (The box should be divided in to two compartments 500 mm from TOP with door arrangement including locking, and bottom 1000mm closed fully with screws WAGO/Pheonix/Elmex terminals suitable for cable dimensions maximum of 2.5 sq.mm. Provision of easy and ensuring aesthetics.
1.00 Panel' and termination of cables on Wago/krone connectors as per the instructions of the site Engineer.
28.00 Disconnecting terminals of Wago/Pheonix/Elmex make or similar.
28.00 disconnecting terminals of Wago/Phoenix//Elmex make or similar
60.00 conforming to RDSO specification No.IRS-TC 77/2012 Rev 3.0 or latest for quad cable. SWR-CONST-UBL-S AND T/SOUTH WESTERN RLY
40.00 Shrinkable type complete for 6 quad cables. After the jointing the through cable has to be tested for insulation resistance and loop resistance in presents of Railway Engineer and in case of any defects the jointing has to be done at free of cost by the contractor. [Heat Shrinkable jointing kit conforming to RDSO specification No.IRS-TC 77/2012 Rev 3.0 covered in the supply portion has to be used for this purpose.] The Contractor should supply all other small items free of cost which are required for making a joint. Only gas blower to be used for blowing
52.00 damaging the fiber and provision of joint chamber of 1.2 mtr dia, 60 Cm height and 50 mm thickness with two-piece top cover and bottom cover. with holes for drainage and cable entry (The reinforcement drawing enclosed). This includes backfilling and ramming of the trench after placing the joint closure and cable loop in the chamber without causing any damage to the same and consolidation of soil as well as disposal of soil as per plan and as advised by RailTel Representative.
52.00 RCC joint chambers with dry sand mixed with ant termite chemical as required in specification up to 400mm height and the cover is refixed in position.
& Section/Derivation OFC Joint enclosure including Splicing (24 Fibre) inside already prepared jointing pit. This does not include provision of Joint chamber, top plate & back filling. The joint Enclosure shall be as recommended in the technical specification
4.00 cable inside service building by providing large G.I. Band at Bottom & vertical G.I Pipe of 75 mm dia. The vertical pipe shall be 75mm above the floor level & the mouth of the pipe shall be covered by Plastic Cap. The floor shall be restored to the original condition.
29.00 470:1120 ohms or 470:600 ohms or 470:470 ohms as per RDSO spec No. IRS-TC-76-2021 or latest. SWR-CONST-UBL-S AND T/SOUTH WESTERN RLY
4.00 accessories, surge protection arrangement, FDF, racks, DDF, runway ladder etc. this includes connecting all pig tails and optical patch cards etc. to SDH and primary mux equipment with all interface cards to 48V bus including supply of wires and connectors, terminations of all E1s on DDF, termination of VF interface circuits to krone type MDF at both ends including taking PVC cable over runway or a wall, krone type DP with all surge and lighting protection complete for all the circuits derived from PD mux. This work includes wiring and connection of telephones in SM's room and extension of generator supply equipment. All miscellaneous materials like power wires conduit and accessories etc. shall be supplied by the contractor. Suitable link panel should be provided on this rack for testing and isolation of fault.
5.00 charger 230V AC 50Hz input and 48V DC/25 Amps output in (2+1 configuration) suitable for VRLA battery as per RDSO specs: RDSO/SPN/TL/23/99 ver.4 or latest.
and 48V,200AH VRLA battery bank as per latest specification No.IRS- S93/96A [One set battery bank contains 24 nos of 2v/200AH cells].
12.00 Rack complete with fittings for housing LER, LSR, SDH equipment, FDMS, DDF and other equipment like cable managers, completely wired using krone module and other equipment's like runaway ladders etc., as per technical specification below. It should be able to lock all the equipment with only order wire telephone outside the rack, the rack should of APW President/ Rittal make etc., The components of the rack are specified below. this includes transportation and installation of rack in prefab/building at specified stations. a. Rack S33 42U 600WX600D -1 no. b. fixed side panels 42U x 600 D - 2nos. c. Front glass door plain 2U/600W -1 no. d. Rear MS door plain 42 U/600W-1 no. e. Caster with brakes- 2nos. f. Fans directly mounted on the top 48v Dc 90CFM - 2NOS. g. Krone mounting bracket -01 No. h. MCB mounting panel with MCBS a)32 Amps MCBs (DP) - 2 nos. b) 6 Amps MCBs (DP) - 6 nos. i. Earth continuity kit -o1 nos j. Equipment trays-5 nos. k. channel with cable loops 42U-2 Nos SWR-CONST-UBL-S AND T/SOUTH WESTERN RLY
7.00 testing of Rack/Wall mountable FDMS and termination IN and OUT 24 fiber OFC cables (with all connecting materials) routing/dressing fiber as per direction of engineer/In charge. this work includes termination/splicing of fibers and testing of fibers in the section/block and report of fiber to be submitted in hard and soft copy.
50.00 testing of Rack/Wall mountable FDMS and termination IN and OUT 48 fiber OFC cables (with all connecting materials) routing/dressing fiber asper direction of engineer/In charge. This work includes termination/splicing of fibers and testing of fibers in the section/block and report of fiber to be submitted in hard and softcopy.
340.00 for STP/UTP cable
2.00 control telephone (4Wire/2Wire) as per RDSO specification IRS: TC- 78/2020 Ver. 1.1 or latest.
4.00 Way station equipment DTMF and control telephones. The work involves fixing the released way station equipment on the wall at an appropriate place in consultation with Railway representative at site, wiring and interconnecting the same with test panel, control telephones and batteries. (Supply of way station equipment, control telephones and batteries is not included in this item). [Wire PVC 3/0.75mm & 16/0.2mm copper, MS clamps for fixing arrangements, PVC tubes 25mm dia for interconnections and all other miscellaneous items required for the work shall be supplied by the Contractor].
20.00 of FRP type, conforming to specification RDSO/SPN/TC/44/2002 Ver. 3.0 or latest.
20.00 RDSO Spec. No. IRS/TC/42/20 Ver. 1.0 with latest SWR-CONST-UBL-S AND T/SOUTH WESTERN RLY
of communication along the railway track. Fabrication of emergency post as per RDSO Drawing No. UBL/SG/CON/6/2004 and fixing of emergency socket post and burying the post to a depth of 1m after entry of cable. The post to be painted with red oxide before installation. This includes termination of derivation cables on termination strip inside the emergency socket, painting of emergency socket post with alternate black and white strips of 6'' width. The paint used should be of standard quality and two coats of paints should be applied. The EMC post should be painted with red oxide base before painting. (rails will be supplied by railways for the fabrication of emergency post)
1000.00 cable through PVC pipe/ Casing capping fixed on the walls, as directed by site InCharge. This work includes termination of cables in the krone connector and fixing of IPM and extending earthing to krone box
5.00 25 Watts synthesized configuration VM-04 of bandwidth 136-174 MHz with DTMF microphone, of Motorola make model GM338/XiRM- 3688 or kenwood TK7360 as per latest specification
testing commissioning of 25 Watt VHF set with GP antenna and antenna cable of length 30 M, power supply and battery of 12V 65AH. This includes supply and fixing of GI pipe of suitable dia to the required height as per the guidance of the field engineer, wiring of antenna cable through PVC conduit. All the materials required for installation to be supplied by the contractor. VHF equipment, SMPS power supply, Antenna &antenna cable will be supplied by the Railways.
Jim Numbers antenna for 25-Watt VHF set
5.00 RG 217U with silver tipped connectors on both ends, 30 meters length
5.00 Boost mode Power supply unit of 12V/15Amps. for HF/VHF/UHF Transceiver.
5.00 Battery 12v/100ah Similar to Amar Raja make or better. SWR-CONST-UBL-S AND T/SOUTH WESTERN RLY
5.00 office clock with GPS synchronization (stand-alone mode) as per RDSOSpec.No. RDSO/SPN/TC@47>47@2008 Rev 4.1 or latest with RED LED with complete installation including all necessary accessories as directed by Railway Site Engineer.
5.00 Sided Clock with GPS synchronization as per RDSO Specification No RDSO/SPN/TC / 62 /2008 Rev 4.1 or latest. Including all the accessories required for the installations.
1.00 core i713th Gen with windows 11 pro (16GB) Make: Dell or equivalent as per latest technical specification
130.00 cards 5 Mtrs length as per site requirements. (LS-SC, SC-SC, LC-LC, FC-FC patch cards as per site requirement) Total 6698681.00 Item- 21 Chapter-22 Logistics and Site Support Arrangements S No. Item No Description of Item Unit Qty Rate Amount
of materials by road as per the instructions of Railway representative at site. The work also includes loading and unloading of the materials. Transportation more than 100 Kms.
6.00 (Model: Godrej Store well/slimline 4S)
of Numbers Office/executive/computer support Revolving Chairs (Bravo high back and Cushioned) of Godrej or reputed firm for seating arrangement
21.00 plank with thickness of 18mm, teakwood beading with three draws of size 4' X 2' with heavy duty S type chair with hand rest. The above is of Godrej or similar make
34.00 or better with 2 keys.
8.00 made of BATHLA make or better of App 5 feet height
9.00 Aluminium ladder of size 25 X 25 X 5mm, 200mm width, arrangements for drawing various wires in the battery, equipment and relay rooms. SWR-CONST-UBL-S AND T/SOUTH WESTERN RLY
60.00 telephone handle type and supply and wiring of Ni-cad power pack 4V- 2.2AH with charger to work on 110VAC, at the station house, LC Gate and top points. [Magneto telephone handle type with Ni-cad power pack 4V-2.2AH with charger to work on 110VAC, wire PVC 16/0.2mm copper, and all other miscellaneous materials shall be supplied by the Contractor.]
12.00 wood tool box of size 1000X750X100mm made of 25mm thick teakwood per splex sheet fronted 6mm (Colourless) fixed on the wall at a convenient location as instructed by Railway representative at site. The board should have provision of pad lock and locking arrangements and shall be equipped with the following tools[reputed make]: Digital Multimeter similar to Model No.Rish Multi 15S with suitable carrying case and test probes. Multimeter similar to Model No.HM 102 BZ Hungchung with test probes with suitable carrying case.- 1 No. Centre zero ammeter 30-0-30 Amps - 1 No. Screw drivers of different types and sizes with common handle - 1 set Spanner double ended 33mm - 1 No. Spanners double ended 3/8x1/2" - 1 No. Spanners double ended 5/8x3/4" - 1 No. Spanners double ended 7/8x1" - 1 No. Hammer 1 1/2 lbs ball pane - 1 No. Hacksaw frame - 1 No. Adjustable screw spanner 12" - 1 No. Insulated cutting pliers- 1 No. Insulated nose plier- 1 No. Electric soldering iron 230V 60W Soldron/Philips make - 1 No. o. Electric soldering iron 110V 35W Soldron/ Philips make - 1 No. p. Megger 500V/ 500Mohms. with Probe - 1 No. The above tools shall be purchased from Reputed manufacturers only in consultation with the Railway representative at site. [Teak wood tool box made of 25mm teakwood plank, per spex sheet, all the tools mentioned above, padlock and other miscellaneous items shall be supplied by the Contractor]. Total 3613831.00
C-FOIS (NON SOR)
D-IPMPLS (NON SOR)
E-VSS (NON SOR)
F-PA SYSTEM (NON SOR)
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
HTML
nit.pdf
NIT
SpecialConditionsofContractSCC.pdf Special Conditions of Contract
ATTACHMENT
RegulationtoTenderers.pdf
ATTACHMENT
InclusionofVehicle.pdf
ATTACHMENT
GCCAPRIL2022uptoACS10.pdf
ATTACHMENT
JPOforOFC-QC-CUT-DAMAGE.pdf
ATTACHMENT
RlyBdcomplianceGSTAct2017.pdf
ATTACHMENT
TechnicalforOFClaying.pdf
ATTACHMENT
SIPYardPlans.pdf
ATTACHMENT
TelecomTechnicalSpecifications.pdf Telecom Technical Specifications
ATTACHMENT
IRSGCCAPRIL2022ACS-11.pdf
ATTACHMENT
TechnicalSpecifications-1.pdf
ATTACHMENT
RlyBdLetterforLocalContent.pdf
ATTACHMENT
OFCDrawingIndicatorRLYOFC.pdf
ATTACHMENT
Splattentiontobidder.pdf
ATTACHMENT
ProformaJune2026.pdf
ATTACHMENT
SpecialConditionsofContractSCC.pdf
ATTACHMENT
TelecomTechnicalSpecifications.pdf
ATTACHMENT
Download all tender documents and submit your bid