Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹2.8 LAccepted-AOC PRATAPBAGAN | L1 | Accepted-AOC Accepted | |
| 2 | L2₹2.8 L+₹248.91 (0.09%)Rejected-Finance RAMPUR HAZRA LANE BANKURA W B | BANKURA | BANKURA | WEST BENGAL | L2 | Rejected-Finance Rejected | |
| 3 | L3₹2.8 L+₹123.89 (0.04%)Rejected-Finance INDARAGORA BANKURA W B | BANKURA | BANKURA | WEST BENGAL | L3 | Rejected-Finance Rejected |
Tender Value
Refer Docs
EMD Value
₹6,000
Closing Date
22 Jul 2024, 6:00 pmClosed
Assistant Engineer
O/O AE, BMSD(W/S), PHE Dte, Ailakundi, Bankura
Rectification of illumination system and the existing transformer at pump house premises of Mejia W/S Scheme under BMD, PHE, Dte.
2024_PHED_709298_8
WBPHED/AE/BMSD/NIeT- 3 OF 2024-2025
Open Tender
MECHANICAL
Item Rate
15 days
Bankura
Please refer Tender documents.
5 documents required · 5 mandatory
₹6,000
Yes
19 Feb 2025
12 Jul 2024
25 Jul 2024
12 Jul 2024
22 Jul 2024
12 Jul 2024
Amount
6 sqmm 2 core 1100V grade XLPE insulated aluminium Armored cable ,cable As Per IS-7098 (Part 1) 2011 with Up To Date Amendments,
Laying of above cable through the under ground trench having depth 760mmX width 460mm and laying 8 nos brick for per mtr length of the cable for protection of the cable including sand filling ramming complete as per IE rules as per direction of the EIC.
Excavation of soil for installation of Earth Electrode and filling & ramming. For Soft Soil
Earthing with 50mm dia GI pipe 3.64 mm thick x 3.04 Mts. long and 1x4 SWG GI (hot dip ) wire (4 mts long) , 13 mm dia x 80 mm long GI bolts, double nuts, double washers incl S & F 15 mm dia GI Pipe protection ( 1 mtr long ) to be filled with bitumin purely under the ground level and partly above ground level driven to the average depth of 3.65 Mts. below the ground level as below: By ISI-Medium GI pipe
Extra for providing masonery enclosure on the top of the earth electrode of overall size 86.36 cm x 86.36 cm x 46 cm deep (below Ground level) complete with cemented brick work(1:6) of 25 cm width duly plastered with cement morter (inside) CI hinged inspection cover of size 36.56 cm x 35.56 cm with locking arrangement, GI reducer including drilling of 46 nos.12 mm dia holes on the GI pipe
Connecting the equipments body to earth busbar incl. S & F 25 mm x 6 mm Galvanized (Hot Dip) MS flat on wall/floor with GI saddle as required and connection to equipments with incl. drilling holes, bolts, nuts,washers etc.
Supplying and fixing compression type gland complete with brass gland, brass ring & rubber ring for dust & moisture-proof entry of XLPE/PVC armoured cables as below : For 4 core 6 sqmm cable
Finishing the end of following XLPE/PVC armoured cables by crimping method incl. supplying and fixing solderless socket (Dowels make), tapes, anticorrosive paste & jointing materials : i) 4 core 6 sqmm cable
Supplying and fixing 240/415 V MCB of Breaking capacity 10kA & C characteristics on din rail of existing DBs and necessary connection A) 16 A (SPN) Make-Havels
Supply and inter connection of power line from light fixture to jointing box by the 1.5 sq mm x 2 nos pvc insulated HRFR 1.1 kv grade copper flaxible cable
Supply delivery fitting fixing 20 Watt capacity LED Bulb Stellar Bright cacity 2000lm and 15K life hours Type -BN 021 LED12S 6500 PSU GR/ Equivalent (Make Havells/Philips)
Supply and fitting after dismantling the existing faulty LED light at the existing poles GreenLine V2 is an IP66 road lighting luminaire with Single Die ceramic base high power LED light source, PDC housing, Toughtened Glass cover and unique peanut lens to ensure uniform light distribution, higher spacing between poles and maintenance free system. (Model-BRP409 LED115 CW SLC FG PSU GR V2 or equivalant ) (Make- Philips)
Supply and fitting after dismantling the existing faulty LED light at the existing poles Flood lighting luminaire with Single Die ceramic base high power LED LED, PDC Housing & integrated flood optics to ensure uniform distribution maintenance free system, ideal for sports lighting, area lighting and high mast lighting. (Model- BVP483 LED235 CW SWB PSU GR or equivalnt ) (Make- Philips)
Supply delivery of the below items at site for the rectification of 160 KVA transformer
New transformer oil IS-335 (Make- Transol )
150 sq mm Heavy duty Al Socket (Make- Reputed)
Supply of all kind of gasket & oil seal HT , LT bushing , top cover , inspection cover , valves etc for 160 KVA 11KV/433 transformer
Supply of screened outdoor termination kit for xlpe/pvc 120-185 sq mm
LV/LT Heat Shrink Type Straight Through Joint (Splice) Kit upto 150 sq mm
Carring charges for oil filteration machine with Di- electric mchine from recommended workshop to work site of Bankura
Drain out of existing oil of 160 KVA trnsformer (240 lit approx)
Hairing charges drums for holding the above said oil
Transformer and Avr oil filteration charges
Charges for Di-Electric Strength test (BDV Test) of 1 nos Transformer oil
Attending the fault at Mejia W/S Scheme of Mejia Block of Bankura District with carrying different Testing servicing kit/machine like Insulating Resistance checking machine Blower , Multimeter, clamp meter , Different type of tools tackles , verious testing wires, MCBs , wires & Cables , HT insulation tapes, Gas can with nozzle, CRTWD-40, Lecta cleaner , Adesive non adesive PVC taps and itrms and complete servicing and testing the Transfoemers HT, LT cables increasing the IR value of the HT LT cable installation of the sl no 14 replacement of the HT LT kit (if needed) and all other parameter of the transformer as per direction of EIC . (Test report of the transformer to be submitted after the rectification)
Add: 18% GST
Add: 1% Cess
ABHIJIT MUKHERJEE
M/S NABIN GOPAL SENGUPTA
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .