| 1 | L1₹14.1 LAccepted-AOC NAU PUKHRI ROAD MILLAN PALLY BYE LANE 2 NEAR GOYAL PALACE PO DISTT TINSUKIA ASSAM 786125 | TINSUKIA | ASSAM | 786125 | ₹14.1 L Quoted ₹15.0 L | L1 | Accepted-AOC DUE TO L1 |
| 2 | L2₹16.0 L+₹1.0 L (6.85%)Rejected-Finance 1389 RADHETENAMENT SOCIETY SARDAR ROAD SURENDRANAGAR SURENDRA NAGAR GUJARAT 363001 | SURENDRANAGAR | GUJARAT | 363001 | ₹16.0 L+₹1.0 L (6.85%) | L2 | Rejected-Finance OTHER THAN L1 |
| 3 | L3₹16.1 L+₹1.1 L (7.60%)Rejected-Finance | ₹16.1 L+₹1.1 L (7.60%) | L3 | Rejected-Finance OTHER THAN L1 |
| 4 | L4₹16.5 L+₹1.5 L (10.0%)Rejected-Finance | ₹16.5 L+₹1.5 L (10.0%) | L4 | Rejected-Finance OTHER THAN L1 |
| 5 | L5₹16.8 L+₹1.8 L (12.2%)Rejected-Finance NO 1 RANGAJAN VILLAGE PO BOKULONI CHARIALI MAUZA TIPLING SUB DIVISION TENGAKHAT DIST DIBRUGARH ASSAM 786191 | DIBRUGARH | ASSAM | 786191 | ₹16.8 L+₹1.8 L (12.2%) | L5 | Rejected-Finance OTHER THAN L1 |
Tender Value
₹14 L
EMD Value
₹28,000
Closing Date
2 Sept 2023, 6:00 pmClosed
GE LEKHAPANI
TINSUKIA, ASSAM
REPAIRS AND DAY TO DAY MAINT OF SECURITY LIGHTS, LIGHTNING CONDUCTOR, EARTHING ETC AT LEKHAPANI
2023_MES_612378_1
8753/E8
Open Tender
Miscellaneous Works
Item Rate
180 days
GE LEKHAPANI
Class E and category b (i)
9 documents required · 9 mandatory
₹500
GE LEKHAPANI
₹28,000
Yes
6 Oct 2023
5 Aug 2023
9 Sept 2023
5 Aug 2023
2 Sept 2023
19 Aug 2023
Amount
Disconnecting & Taking down unserviceable all type security light fitting of any type/specification complete from the PCC Pole/Steel tubular poles/High mast/building for repair and replacement of burnt/worn out accessories where required, including repairs to un serviceable wiring, connection, minor supplying of spares like nut & bolt, connectors, screws, washers etc and reconnecting/refixing the same and testing complete all as directed by Eng-in-charge. Notes:- (i) Vehicle, ladder, tools & plants as required at site for repair/repalcement of light fitting functional shall be provided by the contractor at his own cost & arrangement. (ii) Spare required will be measured and paid separately under relevant schedule of items and only minor spares like nut & bolt, connectors, screws, washers etc deemed to be included in the quoted rate. (iii) Contractor will deposit new material to Engr -in-charge for accepetance & then material will issued by JE E/M based on assesement of complaints.
All as per item No 1 in above but without taking down the light fitting from its position & tightening the fitting rigidly in postion after necessary repair/replacement of spares parts all as specified & directed by Engineer-in Charge.
All as per item No 1 in above but taking down the post top lantern/Garden light fitting of any type from Gates/GI poles etc. for repair and replacemnt of burnt/worn out accessories for carrying out of repair or removing from site all as directed.
Supply only to incorporate in item No.1, 2 & 3 above, electronic driver for LED street light upto 30/35 watt suitable complete all as directed. Note :- Suitable for street light of any type/make. Driver will be procured as per sample, as required on site compatable for existing light fittings.
Supply only to incorporate in item No.1, 2 & 3 above, electronic driver for LED street light 45/50 watt complete all as directed. Note :- Suitable for street light of any type/make. Driver will be procured as per sample, as required on site compatable for existing light fittings.
Supply only to incorporate in item No.1, 2 & 3 above, electronic driver for LED street/flood light 60 to 120 watt complete all as directed. Note :- Suitable for street/flood light of any type/make. Driver will be procured as per sample, as required on site compatable for existing light fittings.
Supply only to incorporate in item No.1, 2 & 3 above, electronic chip/PCB plate with optical lens, suitable for LED Street light upto 20/25/30 watt capacity, by replacing faulty electronics components to make the light fitting serviceable again complete all as specified and as directed.
Supply only to incorporate in item No.1, 2 & 3 above, electronic chip/PCB plate with optical lens, suitable for LED Street light upto 45/60/70 watt capacity, by replacing faulty electronics components to make the light fitting serviceable again complete all as specified and as directed.
S & F LED Street light fitting 1 X 45/48 Watt pressure die cast housing heat resistant toughened glass with frame, IP - 66 protection, uniform distribution connecting up complete with suitable size PVC insulated wire ISI marked, including taking out the existing fully rusted unserviceable complete all as specified and as directed.
S & F LED Street light fitting 1 X 60/70 Watt pressure die cast housing heat resistant toughened glass with frame, IP - 66 protection, uniform distribution connecting up complete with suitable size PVC insulated wire ISI marked, including taking out the existing fully rusted unserviceable complete all as specified and as directed.
S & F LED Street light fitting 1 X 90 Watt pressure die cast housing heat resistant toughened glass with frame, IP - 66 protection, uniform distribution connecting up complete with suitable size PVC insulated wire ISI marked, including taking out the existing fully rusted unserviceable complete all as specified and as directed.
S & F LED Flood light fitting 1 X 120 Watt pressure die cast housing heat resistant toughened glass with frame, IP - 66 protection, uniform distribution connecting up complete with suitable size PVC insulated wire ISI marked, including taking out the existing fully rusted unserviceable complete all as specified and as directed.
S&F Dacorative Post top lantern for indirect light fitting of 25W LED IP 65 Protection with fixing accessories and connection complete all as specified and directed.
S&F LED Bollard light fitting 10W, powder coated housing with PC diffuser, IP 65 protection, suitable for office entrance/garden including fitting and fixing accessories complete all as specified and directed.
S&F LED Bollard, Pyramid tripod type light fitting 10W, powder coated housing with PC diffuser, IP 65 protection, suitable for office entrance/garden including fitting and fixing accessories complete all as specified and directed.
S&F LED Blinker light fittings box type in RED colour of size 200mm dia, 220 volt AC supply including all fixing arangement as per site with suitable clamp, electrical connections etc including taking out the old unserviceable Blinker light fittings of any description complete all as specified and directed.
S&F Aviation obstruciton Red colour LED lights fitting of 10 Watt in yellow painted die cast aluminium housing and fixing arangement with accessories on water tank/high tower including taking down old unserviceable fitting any type, complete all as specified and directed.
S&F GI pipe (light grade) bracket of size 32mm dia, 1.2 m long bent to shape as required and fixed with suitable size of MS clamps, nut, bolt, washers etc to poles/walls including removing old unserviceable GI pipe bracket with clamps,etc complete all as specified and directed.
S&F Thermo plastic cable terminal box of size not less then 167x125x82mm including terminals with locking arrangments including necessary mounting arrangement of any steel tubular /RCC poles with suitable size of clamps nuts bolts washer etc. fixed with poles including one single pole MCB of capacity 6-32A and PVC connector for cable termination including removal of old unserviceable plastic cable terminal box complete all as specified and directed.
S&F Weather proof copper twin core cable of size 1.5 Sqmm drawn in and including UPVC conduit medium grade fixed to pole with suitable size clamps or fixing accessories including taking down old unserviceable cable complete all as specified and directed.
M&L Preparation of steel surfaces and applying two coats of aluminium paint over the exisiting steel tubular poles 7.5 - 9.20 mtrs above ground including cross arms/ bracings/clamps etc and 1.5 meter zebra lines with black & yellow colour paint bottom of the pole, after cleaning the existing poles and making good surface all surrounding and writing the pole numbers with white letters on black background all as specifeid and directed by the Engr-in-charge.
M&L Preparation of concrete surfaces and applying two coats of cement based paint on PSC poles of height 7.0 - 9.20 mtr above ground with 1.5 meter zebra lines with black & yellow colour paint bottom of the pole and making good surface all surrounding and writing the pole numbers with white letters on black background complete all as specifeid and directed by the Engr-in-charge.
M&L Preparation of steel surfaces of any description over 10 cm width or girth and painting of two coats of synthetic enamel paint over one coat of red oxide primer for metal surface of panels, cable duct cover, shutters, etc complete all as specifeid and directed by the Engr-in-charge.
Excavation in trenches not exceeding 1.5 mtr wide and not exceeding 1.5 mtr depth for taking out/for laying under ground cables/pipes etc and getting out in soft/loose soil complete all as specifeid and directed
Returning filling in including spreading, levelling, watering and well ramming in layers n-exc 25 cm complete all as specifeid and directed
Removing excavated soil to a distance n-exc 50 mtr and depositing where directed at a level n-exc 1.5 mtr above the starting point complete all as specifeid and directed
Supply and spreading fine river sand in trenches for cushioning of under ground cable/filling cable ducts complete all as specifeid and directed by Engr-in-Charge. Note : - Only punned thickness shall be measured for payment purpose
Supply and lay burnt brick sub class ‘B’ of standard size laid in trenches as protection to cables complete all as specifeid and directed.
M&L Boring of holes under road, pavement, hard standing by using trenchless technology technique for 40-80 mm dia pipe complete all as specifeid and directed.
S&F GI pipe of size 40 mm dia (light grade) for cable protection , laid in trenches or fixed on pole/wall for passing LT cables including taking out old rusted pipe complete all as specified and directed.
Supply, laying and testing of LT UG cable XLPE insulated heavy duty electric cable with aluminium stranded conductor, 1100 volts grade, cross sectional area 10 sq mm 2 core including taking out old unserviceable cable complete all as specified and directed.
All as per item No 31 above but size 16 sq mm 4 core complete all as specified and directed.
All as per item No 31 above but 25 Sq mm 4 core complete all as specified and directed.
M&L for steel tubular swaged poles complete with cast iron base plate, final taper plug, bolts, nuts and screws as specified type 410 SP-22, 8.5 metres long including erection, painting with two coat of synthetic enamel paint over a coat of red oxide or primer complete including taking down old unserviceable PCC/Steel Pole complete all as specified and directed. (Note Excavation earth work and PCC paid and measured seperately)
M&L for steel tubular swaged poles type 410 SP-03, 7.0 metres long including dacorative type single arm bracket for street light fixing on top of the pole size not less then 1.0 Mtr as per sample complete, with cast iron base plate, final taper plug, bolts, nuts and screws as specified, including erection, painting with two coat of synthetic enamel paint over a coat of red oxide or primer complete including taking down old unserviceable PCC/Steel Pole complete all as specified and directed. (Note Excavation earth work and PCC paid and measured seperately)
M&L PCC (1:4:8) type D2 (using 40 mm graded stone aggregate) for making good surfaces in road cutting, pole foundation, stay concrete etc complete all as specified and directed.
M&L PCC(1:3:6) type C1 (using 20 mm graded stone aggregate) as in coping including necessary form work and finishing exposed surface/white washing,etc complete all as specified and directed.
S&F Timer distribution board/street light panel of capacity 32/40A, 230 volt 3 pole with astronomical/digital time switch, contactor, MCBs and out going terminal with necessary mounting arrangement as per sample including taking down un serviceable panel complete all as specified and directed by Engineer-in-Charge.
S&F Astronomical/digital timer switch 110 - 240 VAC 3 Phase - 4 Wire 3 Channel 3 N/O including all necessary electrical connection in LT panel including taking down un serviceable timer switch all as specified and directed by Engr in charge.
S&F Triple pole contactor of capacity 40A of coil voltage of 415V AC with auxillary contact arrangement of having 2 NO (Normally open) + 2 NC (Normally closed) including taking down U/S contactor complete all as specified and directed by Engineer-in-Charge.
S&F 3 pole MCB of capacity 40A with breaking capacity of 10KA including taking down U/S MCB complete all as specified and directed by Engineer-in-Charge.
S&F Single pointed Air Termination aluminium rod 12mm dia and 300mm long including necessary fixing arrangement complete all as directed by Eng-in-charge.
S&F Aluminium Strip 25 x 3.00 mm complete with saddle and fixing screw, epoxy insulators for roof or down conductor or fixed to pole or any other indicated situation for loop earthing etc, as required including making test point and testing complete all as directed.
M&L for Test point terminal block made of gun metal or phosphorus bronze size 75mm x 75mm x 25mm, drilled and screwed including 03 Nos 8 mm dia 25 mm long hexagonal head screws with suitable enclosure made out of 3 mm thick CRCA sheet box all as specified and as directed.
M&L Earthing complete with galvanised steel earth plate electrode 60cmx60cmx6.0mm thick, buried directly in ground (earth pit not less than 2.25 mtrs deep below ground level) with top edge of the plate not less than 1.5 mtrs below normal ground level, connected to galvanised iron strip 32×6mm as earthing lead by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No 3 in SSR Part -I (2009) connected to earting test point all as specified complete with excavation & earth work, PCC pit with 50mm thick RCC cover (grade M-15) having suitable handle (10mm MS Rod) 20mm dia GI pipe medium grade ISI marked watering pipe with GI funned with wire mesh 40mm bore GI pipe medium grade ISI marked for protection of earth lead conductor and testing on completion,etc.complete all as specified and as directed by Eng-in-charge.
M/S S. P. ENTERPRISE
M/S. MATA VAISHNO DEVI ENTERPRISE
RC CONSTRUCTION
M/S SINGH TRADERS
M/s PRABIR ENTERPRISE
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .