GE (AF) E/M CHAKERI KANPUR
GE(AF)EM Chakeri
Comprehensive Maint / repair of chloronome plant and other allied works including repair to storage water heater in domestic area at AFS Kanpur
2023_MES_619780_1
8669/E8
Open Tender
Civil Works
Item Rate
270 days
Area under GE(AF) EM Chakeri
As per tender documents
9 documents required · 9 mandatory
₹500
GE(AF) EM Chakeri
₹50,000
Yes
20 Nov 2023
21 Sept 2023
25 Oct 2023
21 Sept 2023
19 Oct 2023
6 Oct 2023
Amount
Taking down carefully geyser (storage type) of any make of capacity 25/35/50 Ltrs at any height disconnecting electrically and mechanically from all existing line opening complete including back plate, inner copper tank etc. de-scaling of copper tank , heating element and cleaning with Sulphuric Acid / de-scaling compound and reassembling and fixing in same position after necessary repair / replacement including replacement of old nuts & bolts and rubber gasket etc in side the geyser complete all as specified and directed. Note :- (i) Replacement of unserviceable spares shall be measured and paid separately under appropriate items of Schedule 'A' . (ii) Inspection of electric geyser any capacity, any type, any make for minor defect tightening of nut and bolts, connecting wire, pipe lines and rectifying the defects.
Supply only heating element 2000 watt capacity push / screw type with 'O' ring including making electrical connection complete all as specified and directed. Make:- Theeta/ Bajaj or any make approved by GE
Supply only thermostat switches ISI marked including making connections complete all as specified and directed. Make:- Theeta/ Bajaj/Racold
Supply only indicating lamp round/triangular red/green 220 volt AC as required at site including electrical connections complete all as specified and directed.
S&F in repair PVC connection 600 mm long with two nos nut adopter ISI marked for hot/cold water complete all as specified and directed. Make:- Paras/ Prayag or any make approved by GE
S&F in repair PVC connection 750 mm long with two nos nut adopter ISI marked for hot/cold water complete all as specified and directed. Make:- Paras/ Prayag or any make approved by GE
S&F in repair PVC connection 900 mm long with two nos nut adopter ISI marked for hot/cold water complete all as specified and directed. Make:- Paras/ Prayag or any make approved by GE
S&F in repair door assembly with element push type with 'O' ring and square ring for 25 ltrs capacities geysers complete all as specified and directed. Make:- Bajaj/Summer cool or any make approved by GE
M&L in repair for soldering/brazing of inner tank of geyser of any type & capacity as required to make its functional complete all as specified and direected
S&F in replacement of stop valve cast copper alloy screwed down high pressure with crutch or butterfly handle screwed both ends for GI pipe 15 mm dia bore complete all as specified and directed.
All as per serial item No. 10.00 above but cast copper alloy chromium plated complete all as specified.
M&L in repair 3 core PVC sheathed copper conductor flexible cable of size 2.5 sqmm complete all as specified and directed. Make:- Finolex/Paragaon/Havells
S&F inner steel tank of capacity 25 litre Geysers complete all as specified and directed. Make: - Bajaj/Summer cool or any make approved by GE
S&F in repair single pole and neutral enclosure 20 Amp with a two pin and earth plug and socket with one single pole MCB 20 Amp complete all as specified and directed. Make:- Legrand/L&T/Seimens
S&F in repair single pole MCB 16 Amp 10 KA, C curve complete all as specified and directed. Make:- Legrand/L&T/Seimens
S&F in repair pressure release valve of suitable size in geyser complete all as specified and directed.
S&F in repair fastener of suitable size complete all as specified and directed.
S&F in replacement of GI tubing medium grade ISI marked with all fittings laid in trenches/ floor/wall or ceiling of size 15mm bore all as specified and directed by Engineer in Charge
S&F in replacement of electric water heater, storage type steel body with copper inner tank and heating element up to 2KW, capacity 25 ltr, BEE 5 Star rated complete with all accessories such as safety valve, thermostste, NRV, connection piece etc. complete all as specified and directed by Engineer in Charge. Note: Old Gyser shall be deposted to MES Store Yard)
Repair / maintenance of chlorine granuals based dosing plant comprising dosing pump, agitator and 100 ltr FRP tank (Make- Declibac ) and connected pipe lines as per manufacturers recommendation which include the following complete all as specified and directed:- (i) Cleaning of chlorine plant room once in a week. (ii) Daily Checking of all Chlorination plants /testing of complete system for serviceability of plant. (iii) Daily Testing of chlorine at consumer end with medical authority and maintained chlorine test record . (iv) Minor repair/cleaning of PVC pipe line /NRV to make plant functional. (v) Routine maintenance and servicing of agitator of by using necessary lubricant, replacement of bush/bearing, aligning the shaft , key etc. Notes : (a) Any other spares required for replacement shall be measured and paid under relevant item of BOQ. (b) If any defect found in plant contractor should rectify the defect with in 24 Hrs, if failed to rectify the decfect the contractor shall be liable to pay compensation Rs 500/- (Rupees five hundred only) per plant per day.
Supply only gear motor 230 volt,50 Hz for chlorine dosing pump complete all as specified and directed.
Supply only roller assembly complete all as specified and directed.
Supply only Roter assembly complete all as specified and directed.
Supply only PVC pump tube as per sample complete all as specified and directed.
Supply only injection check valve 3/8" size complete all as specified and directed.
Supply only weighted suction line strainer 3/8" size complete all as specified and directed.
Supply only white suction /discharge tubing 3/8" size complete all as specified and directed.
Supply only agitator motor with suitable capacity alongwith agitator shaft & impeller made poly propylene rigid 32 mm dia and 500 mm length complete all as specified and directed.
Supply only pump head complete all as specified and directed. (Note: Old Pump Head shall be deposited in MES Store Yard )
Supply only check valve duck bill complete all as specified and directed.
Supply only dosing tank complete all as specified and directed. Make:- Declibac Technologies (P) Ltd. / Shree Rayalaseema Hi Strength Hypo Ltd. / Petter and watts
Supply only calcium based high strength granular chlorination chemical with CIAS having 65 % to 70 % active chlorine, whitish, free flowing, decomposes clear in water solution , free of foreign matter , the chlorination chemical should contain appropriate quantities of dispersants, corrosion inhibitors to prevent incrustation scaling in distribution systems, mercury and other heavy meatl conteminants in chlorination chemical must be Below Detectable Limit (BDL) complete all as specified and directed. Make:- Bharti Water/ Shree Rayalaseema Hi Strength Hypo Ltd. / Petter and watts/ Declibac Technologies (P) Ltd.
M&L for rewinding of agitator motor of capacity 120 watts, 960 RPM single phase 230 V and using copper winding wire of existing gauge with necessary insulation material including testing after repair and refixing of the same complete all as specified and directed.
S&F in replacement of phase sequncer cum pump protection system 415/440 volt, 50 Hz, internal working voltage 12/14 volt, suitable for 100 HP capacity with MNX-95 Contactor in it for auto change of phase sequncer if incomming phase sequnce changes, single phaseing prevention system and adjustable low and high voltage protection system to protect the machniery, mounting on bracket made out of 40x40x3mm angle iron frame , all control wiring, cable connection all as directed by Engineer in Charge. Make: Indian Engineering Co. / United Engineering as approved by GE
S&F in replacement of Bib Tap 15mm size ISI marked standard PTMT any colour high pressure screwed for iron pipe all as specifed and directed by Engineer in Charge
Earthing complete with galvanised GI earth plate of size 600 x 600 x 6mm thick burried directly in ground not less than 2.25 Mtr below ground level, earth plate paced on all side with charcoal mixed with salt to a thickness of 150mm in layers, connected by GI earth wire 4 mm thick, soldered and revetted to earth plate. GI earth strip will be protected by using 15mm bore GI pipe (light grade) from test point to main board. The earthing includes PCC pit chamber, RCC pit cover and frame, watering pipe 20mm bore, funnel with wire mess with necessary earth work including disposal of surplus soil to a distance not less than 50 Mtr etc complete all as specified and shown in electrical plate No 3 of SSR Part-I (2009) and providing earth indentification plate size 250x200x1.6mm thick welded with angle iron 25x25x4mm (600mm long) embedded in ground with PCC(1:3:6) type C2 using 40mm graded stone aggregate.Earth plate shall be marked with type of earthing, Test results with black paint with white back ground paint in standard letter font) Note : - Rate quoted by contractor deemed to be inclusive of Earth conductor upto 7.5 RM all as directed by Engineer in Charge.
Cleaning of pump house (area appx 500 Sqm) and all connected valves pits inside and out side and cleaning roof of buiding , cutting of grass in side of boundary wall, surrounding to OHT and complete including removal of debrish/ waste to a distance exceeding 50mtr but not exceeding 250mtr all as directed by Engineer in Charge
Supply, lowering and fixing MS ERW Column pipe 250 mm bore of class C heavy duty , 3.0mtr in length having wall thickness not less than 7.1mm electric registance welded with MS flange heavy duty on both side confirming to IS:3589 & 1239 with provn of 8 Nos holes welded all around with pipe for rigidness and 4 nos ribs 10mm thick and providing 2mm thick rubber sheet and nut bolts of of suitable length and washers shall be confirming to IS and including connecting and providing two coat of synthetic enmel paint over a coat of red oxide primer as directed by Engineer in Charge. (Note: Payment of 3mtr length MS Column pipe shall be treated as Each unit).
All as per item no 38 here in before but suitable for 200mm bore pipe
All as per item no 38 here in before but suitable for 150mm bore pipe
Supply & laying Pea gravels for packing of size 3 to 5mm to be designed by the contactor of natural shape brought directed from river bed and packing around the casing and sloted pipe complete all as directed by Engineer in Charge. (Note:- For measurement purpose stack measurement of Pea gravel braught at site shall be recored in MB and after pouring remaining Pea gravel shall also be entered in MB)
Demolition of brick work built in cement mortar in any type complete all as directed by Engineer in Charge
M&L for brick work with sub class ,B' brick straight or curve exceeding 6mtr mean radius built in cment mortar (1:6) complete all as specified and directed by Engineer in Charge
Taking down cement plaster of any description on brick or concrete surface, ceiling etc including racking joints hacking for key scrubbing down with water complete all as directed by Engineer in Charge.
M&L for rendering in 15mm thick cement mortar (1:6) on fair face of brick work surface or concrte surface of wall, finished even and smooth without using extra cement complete all as diretced by Engineer in Charge.
M&L for rendering in 5mm thick cement mortar (1:3) on fair face of brick work surface or concrte surface of ceiling, finished even and smooth without using extra cement complete all as diretced by Engineer in Charge.
M&L for preparation of newly plastered surface of wall and applying three coat of white wash complete all as specified
M&L for preparation of newly plastered surface of wall and applying two coat of oil bound distemper over a coat of primer complete all as specified
M&L for preparation of old decorated surafce of wall/Column/bracing, domes etc by complete removal of treatment and applying two coat of cement base paint all as directed by Engineer in Charge
Demolition of cement concrete (unreinforced) of any description in ground floors and paving not exceeding 15 cm thickness (above or below ground level) complete all as directed by Engineer in Charge
M&L for 75mm thick PCC (1:3:6) type C-2 using 40 mm graded stone aggregate as in flooring/ plinth protection/ subbase, finished even and smooth without using extra cement all as directed by Engineer in Chagre
S&F in replacement of Automatic Star delta starter for 100 HP submersible pump indicating connecting all incomming and out going copper wire complete all as specifed and directed by Engineer in Charge. L&T Cat Part No: MU G50 or equivalent model in Crompton greaves as approved by GE
S&F in replacement of wire less water level indicator digital type with 7-segment LED display water level of the tank in % with resolution of 1-2% resolution, it recive water level data from transformer and display in % with rest switch to put off the buzzer sound with fuse protection system on/off switch for receiver display unit including water level data transmeter with maintance free water level senser complete with maximum range of signal appx 500 mtr at arial distance including necessary suitable size of copper cable connection for 230volt supply complete all as specifed and directed by Engineer in Charge. Make: Aqua brim Model Penta cool challenger digital /Spacon /Johnson automation and control as approved by GE. (Note:- Old u/s water level indicator shall be depoisted in MES store yard ).
Kumar Electricals
Preetpowercontrol
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .