Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹12.2 CrAccepted-AOC | ₹12.2 Cr | L1 | Accepted-AOC Being Lowest |
| 2 | L2₹12.4 CrRejected-Finance AT BARIMAL PO HATIBARI PS SUKINDA DIST JAJPUR PIN 755018 | JAJAPUR | ODISHA | 755018 | ₹12.4 Cr | L2 | Rejected-Finance Not being Lowest |
| 3 | L3₹12.5 CrRejected-Finance | ₹12.5 Cr | L3 | Rejected-Finance Not being Lowest |
| 4 | L4₹12.7 CrRejected-Finance K 99 LGF KALKAJI NEW DELHI 110 019 | NEW DELHI | SOUTH EAST DELHI | DELHI | 110019 | ₹12.7 Cr | L4 | Rejected-Finance Not being Lowest |
| 5 | L5₹13.9 CrRejected-Finance | ₹13.9 Cr | L5 | Rejected-Finance Not being Lowest |
Tender Value
₹9.3 Cr
EMD Value
₹7.9 L
Closing Date
27 Jun 2022, 6:00 pmClosed
CE NAVY VISAKHAPATNAM
CHIEF ENGINEER NAVY STATION ROAD VISAKHAPATNAM
-PROVISION OF DEFICIENT SINGLE ACCOMMODATION FOR TRAINEE SAILORS AT INS CHILKA
2021_MES_473537_2
82348
Open Tender
Civil Works
730 days
GARRISON ENGINEER CHILKA
AS PER TENDER DOCUMENTS
12 documents required · 12 mandatory
₹3,000
GARRISON ENGINEER CHILKA
₹7.9 L
Yes
24 Nov 2022
3 Jun 2022
29 Jun 2022
3 Jun 2022
27 Jun 2022
15 Jun 2022
Amount
Schedule "A" Part – I to Schedule "A" Part – XI: NOTE: Schedule "A" Part – I to Part – XI are prepriced by MES. Bidders shall insert their Lumpsum amount in Green coloured field under Column - 6 only
Lumpsum price worked out by the contractor for "BUILDINGS & STRUCTURES", as listed in Schedule "A" Part – I
Lumpsum price worked out by the contractor for "SITE CLEARANCE / AREA DEVELOPMENT/EARTH WORK/EXCAVATION", as listed in Schedule "A" Part – II
Lumpsum price worked out by the contractor for "INTERNAL ELECTRIFICATION", as listed in Schedule "A" Part – III
Lumpsum price worked out by the contractor for "INTERNAL WATER SUPPLY", as listed in Schedule "A" Part – IV
Lumpsum price worked out by the contractor for "SEWAGE DISPOSAL", as listed in Schedule "A" Part – V
Lumpsum price worked out by the contractor for "EXTERNAL WATER SUPPLY", as listed in Schedule "A" Part – VI
Lumpsum price worked out by the contractor for "EXTERNAL ELECTRIFICATION", as listed in Schedule "A" Part – VII
Lumpsum price worked out by the contractor for "ROADS /PATH/CULVERT", as listed in Schedule "A" Part – VIII
Lumpsum price worked out by the contractor for "AREA DRAINAGE", as listed in Schedule "A" Part – IX
Lumpsum price worked out by the contractor for "RETAINING WALL", as listed in Schedule "A" Part – X
Lumpsum price worked out by the contractor for "WATER COOLERS", as listed in Schedule "A" Part – XI
Schedule "A" Part - XII: [Miscellaneous Items] [Internal Electrification, External Water Supply, External Electrification and water Coolers]
M & L point wiring complete with 1100 Volts, FRLS grade, 1.5 Sq.mm, Single core, PVC Insulated, unsheathed, multistranded copper conductor cable, confirming to IS - 694 drawn through and including medium grade PVC conduit, 20 mm dia including all accessories concealed in walls / roofs / floors / ceiling etc. and pressed GI steel terminal boxes of thickness 1.12 mm covered with 3 mm thick phenolic laminated white sheet cover for mounting switched, sockets, fan regulators etc concealed in walls, including 1100 Volts, FRLS Grade, 1.5 Sq.mm, single sore, PVC insulated, unsheathed, multistranded copper conductor cable as earth continuity conductor with colour coding and connecting to earth dolly for one light / fan point / exhaust fan / ceiling rose point controlled by one switch complete all as specified.
All as per Serial Item No. 12 above but for one bell point controlled by one bell push.
All as per Serial Item No. 12 above but one 3/5 pin 5 Amp socket outlet point controlled by one switch on same board.
All as per Serial Item No. 12 above but one 3/5 pin 5 Amp socket outlet point controlled by one switch on independent board.
All as per item No.12 here-in-before but controlled by two two way switch complete all as specefied and directed.
M & L point wiring complete with 1100 Volts, FRLS grade, 2.5 Sq.mm, Single core, PVC Insulated, unsheathed, multistranded copper conductor cable, confirming to IS - 694 drawn through and including medium grade PVC conduit, 20 mm dia including all accessories concealed in walls / roofs / floors / ceiling etc. and pressed GI steel terminal boxes of thickness 1.12 mm covered with 3 mm thick phenolic laminated white sheet cover for mounting switched, sockets, fan regulators etc concealed in walls, including 1100 Volts, FRLS Grade, 2.5 Sq.mm, single sore, PVC insulated, unsheathed, multistranded copper conductor cable as earth continuity conductor with colour coding and connecting to earth dolly for 3/5 pin 15 Amp socket outlet point controlled by one switch of 15/16 Amp complete all as specified.
S & F Switch piano, flush type single pole, two way 6 Amps complete all as specified and as directed.
S & F Energy efficient 4 feet LED light fitting with tube 20 watt or nearest size , 230 Volts surface mounted LED batten type with extruded aluminium / CRCA housing and robust construction with necessary acrylic cover as diffuser complete with mounting bracket etc., including connecting upto suitable size copper cable complete all as specified as directed
S & F Energy efficient 2 feet LED light fitting with tube 10 watt or nearest size , 230 Volts surface mounted LED batten type with extruded aluminium / CRCA housing and robust construction with necessary acrylic cover as diffuser complete with mounting bracket etc., including connecting upto suitable size copper cable complete all as specified as directed
S & F Energy savings, surface mounted, bulk head LED luminarie of capacity 10 Watts connecting with 1.0 Sqmm 3 core multistranded copper conductor connecting upto ceiling rose complete all as specified as directed
S & F LED security street light luminaire 25 Watts, new generation energy savings & environmental friendly long life versatile, Pressure die cast aluminium with mid power LEDs as source and HF electronic driver prewired with 1.0 Sqmm copper conductor cable upto connector, with suitable size of bracket of 2.0 Mtr length, nut and bolts, PVC insulated three core flexible cable of suitable size and length duly connected to light fitting complete al las specified and as directed.
S & F ceiling fan, 1200 mm sweep complete AC, single phase, 230 Volt 50 HZ, 5 star rated, connecting with flexible cable 3 core copper conductor of size 23/0.0076 of suitable length from ceiling rose to ceiling fan including all hanging arrangement complete all as specified and as directed.
S & F exhaust fan, 300 mm sweep or nearest size, 900 RPM metal body (heavy duty), complete with louvers suitable for operation on 230 V AC, 50 Hz AC supply fixed on wall making opening, fixing and making good the distrubered surfaces etc connecting with twin core flexible cable of suitable length from ceiling rose to fan complete all as spcified and as directed. Male: Cat No. Turbo force SP of Havells or its equivalent in Bajaj/ Crompton
S & F MCB DB, double door type, vertical, TPN 6 way, 415 Volts, 50 Hz, IP 43 protection with 200 Amps rated bus bar, including provision for fixing MCCB FP 63 Amps as incoming and outgoing circuit MCB SP/TP complete, fill empty way with blanking plates complete all as specified and as directed.
M & L for sub-main wiring with 6.0 sqmm nominal area two single core PVC insulated unshethed multi-stranded FRLS copper conductor cable including one 6.0 sqmm PVC insulated unshethed multi-stranded copper conductor cable for earth wire drawn through suitable PVC conduit of suitable size complete all as specified and as directed. Note :(i) Two run of 6.0 Sqmm + one run of 6.0 Sqmm as a earth wire cable + one run of PVC conduit shall be measured as an one Unit.
S & F MCB SP 40 Amps, 240 Volts, 10 KA, 'C' Curve complete all as specified and as directed.
M & L earthing complete with galvanised steel earth plate electrode 600 X 600 X 6 mm thick burried directly in ground [earth pit not less than 2.25 m deep below ground level] with top edge of Plate not less than 1.50 m below normal ground level connected to GI earth lead wire 4.0 mm dia [earth lead] and GI pipe 50 mm, medium grade for earthing lead protection to the extent of maximum 7.5m, earth plate electrode surrounded by 150 mm thick packed layers of charcoal and common salt filled in alternate layers, connected to the plate by means of GI Bolts & Nuts complete all as per electrical plate No. 3 of SSR Part – I, connected to panel / DB including testing on completion including main earthing, charcoal, common Salt, PCC [1:2:4, Type B1] Pit with RCC 1:2:4, type B1 Cover, 50 mm thick with 6 Nos, 8 mm dia TMT bars in both ways, MS frame made with 40 X 40 X 6 mm angle Iron, MS Funnel with 20 mm bore, medium grade GI Watering pipe, wire mesh, earth work excavation, return filling, removal of surplus soil etc. complete all as specified. Note: GI earth wire upto 7.5 metres shall be deemed to be included in the quoted lumpsum and beyond 7.5 metre shall be measured and paid separately under relavent item.
M & L for 100 mm dia ductile iron pipe spigot and socket type centrifugally cast (spun) all as per IS:8329-2000, class K7 with flexible rubber gasket push on type joint [gasket D jointing] having cement mortar lining with portland slag cement as per IS 455 : 1989 bituminous coating as per Annex 'C' of IS 8329, including provision of specials, such as tee's, elbows, bends, reducers, taper pieces complete all as specified and directed.
M & L for DI specials of any size including any size bends, tile pieces, T-bendsas per IS:9523/2000 of class K-12, Pn 10 with inside cement mortar lining and outside zinc followed by black bitumen coating of size DN 80 to 200 mm DI socketed fitting complete all as specified and directed.
Supply, install, testing and commissioning pressure booster pump of capacity 2 HP, single phase with necessary control panel [starter panel] including water and electrical connections complete all as specified and as directed.
M & L for masonry valve chamber of size 1000 X 1000 X 900 mm [interanl dimensions] comprising of 50mm thick PCC for valve including excavation and earth work in any type of soil and 200 mm thick PCC 1:4:8 type D2 foundation, brick work in CM (1:6) plastring internal surface 15 mm tick in CM (1:4) PCC (1:3:6) type B1 couping 50 x50x6 mm angle iron 3 mm thick MS plate cover complete with locking arrangement painting steel and iron surface with two coat of synthetic enamel paint over a coat of zinc chrome primer complete all as specified and as directed.
M & L for cutting existing road/PCC/drain of size 150 mm wide 230 mm deep for laying under ground cable making good to match with the existing surface with PCC 1:3:6 type C1 [using 40 mm graded stone aggregate] including necessary earth work complete all as specified and as directed.
M & L for boring holes under road, pavement, hard standing by trenching technology using ultra sound technique using necessary machine complete all as specified and directed.
M & L earthing complete with galvanised steel earth plate electrode 600 X 600 X 6 mm thick burried directly in ground [earth pit not less than 2.25 m deep below ground level] with top edge of Plate not less than 1.50 m below normal ground level connected to 32x6mm thick GI strip [earth lead] and GI pipe 50 mm, medium grade for earthing lead protection to the extent of maximum 7.5m, earth plate electrode surrounded by 150 mm thick packed layers of charcoal and common salt filled in alternate layers, connected to the plate by means of GI Bolts & Nuts complete all as per electrical plate No. 3 of SSR Part – I, connected to panel / DB including testing on completion including main earthing, charcoal, common Salt, PCC [1:2:4, Type B1] Pit with RCC 1:2:4, type B1 Cover, 50 mm thick with 6 Nos, 8 mm dia TMT bars in both ways, MS frame made with 40 X 40 X 6 mm angle Iron, MS Funnel with 20 mm bore, medium grade GI Watering pipe, wire mesh, earth work excavation, return filling, removal of surplus soil etc. complete all as specified. Note: GI earth strip upto 7.5 metres shall be deemed to be included in the quoted lumpsum and beyond 7.5 metre shall be measured and paid separately under relavent item.
Supply, install, commissioning and testing of LT Panel board of size 1.2x 1.2x 0.40 metres made out of CRCA sheet 3.15 mm thick outdoor Pedestal type framing with angle iron of size 50x50x6 mm, totally enclosed, factory made powder coated, dust and vermin proof with front and rear opening, hinged doors with projected and raised platform of suitable size weather and water proof with necessary locking arrangements along with lugs, cable glands of various sizes for cables, danger notice plate, strickering of Switcher gear about termination of switch gear, and the nuts/ bolts etc used are to be made of rust proof material incl as per IS: 8623 aluminium bus bar of 300 Amps for phases [not less than 0.70 metre long] and 200 Amps for nuetral RYB insulated with PVC sleeves insulation mounted on Porcelain insulator and foundation, suitable for three phase and four wire LT AC, 50 Hz 415 V complete with necessary internal electric connection as required and provision of the following:
Supply, install, commissioning and testing of LT Panel board of size 1.2x 1.2x 0.40 metres made out of CRCA sheet 3.15 mm thick outdoor Pedestal type framing with angle iron of size 50x50x6 mm, totally enclosed, factory made powder coated, dust and vermin proof with front and rear opening, hinged doors with projected and raised platform of suitable size weather and water proof with necessary locking arrangements along with lugs, cable glands of various sizes for cables, danger notice plate, strickering of Switcher gear about termination of switch gear, and the nuts/ bolts etc used are to be made of rust proof material incl as per IS: 8623 aluminium bus bar of 200 Amps for phases and 100 Amps for nuetral RYB insulated with PVC sleeves insulation mounted on Porcelain insulator and foundation, suitable for three phase and four wire LT AC, 50 Hz 415 V complete with necessary internal electric connection as required and provision of the following:
Supply and install voltage stabilizer for automatic operation, single phase naturally air cooled indoor type and designed for input variation between 170 Volts to 250 Volts with output voltage at 230 Volts with accuracy of +/- 2.5% and of capacity 2 KVA complete all as specified and as directed. Make:- V-Guard/ Volina/Shakti/ Zenith
Supply and fix 40 mm dia PVC drain out pipe including bends, tees, elbows etc., from water cooler to drain complete all as specified and as directed.
Supply and fix 15 mm dia flexible pipe used for water cooler inlet complete all as specified and as directed.
Supply and fix integral LED light suitable for fixing on wall 3 to 5 watts warm white and connected with 0.5 Sqmm 3 core multistranded copper conductor cabe upto ceiling rose complete all as specified and as directed.
ANIL KUMAR BISWAL
GANGA INFRABUILD PVT LTD
SOOD ASSOCIATES PVT LTD
DHARIWAL TRADERS PRIVATE LIMITED
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid