Loading…
Loading…
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance | Admitted-Finance |
| 2 | Admitted-Finance 21 JHAMRI 151 JHAMRI JHAMRI ROHTAK HARYANA 124142 UDYAM HR 07 0030314 | JHAJJAR | HARYANA | 124142 | Admitted-Finance |
| 3 | Admitted-Finance | Admitted-Finance |
Tender Value
₹14.5 L
EMD Value
₹14,000
Closing Date
24 May 2022, 9:00 amClosed
SE ETC ALIGARH
LAL DIGGI ALIGARH
Annual Maintenance of 220 KV and 132 KV Substations Sikandrarao under Electricity Transmission Division II Aligarh
2022_UPTCL_675922_3
ETC-63/2021-22
Open Tender
Electrical Works
Item Rate
365 days
ALIGARH
Please refer Tender documents.
2 documents required · 2 mandatory
₹2,360
SE ETC ALIGARH
₹14,000
21 Jun 2022
10 May 2022
24 May 2022
10 May 2022
24 May 2022
10 May 2022
Amount
Preventive/Break down maintenance of electrical equipments, switch gears, DO set, lighting of switch yard & control room, mulsifire system and other associated equipments etc. at 132 KV S/S Sikandrarao and 220 KV S/S Sikandrarao round the clock by a team comprising the following technical personnel’s:-
TG-2 (01 Nos.)
Line Man/Technician (02 Nos.)
Helper (02 Nos.)
Proper cleaning of complete Switch yard by cutting grass and bushed 4 times & Chemical spray 01 time in a year as per technical specification and details.
Grass Cutting
Chemical Spray
General cleaning of floors in control room building, BCU, Toilet, wash basin, E-Mulsifire room, store room, by phenyl & wet cloth including cleaning of CC road drains in the periphery of substation.
General cleaner (01 No)
Cleaning of cable trenches of various sizes by removing earth deposit and other foreign material in bottom and over the cable racks including removal of cables from the racks and placing it outside trench carefully without causing any damage to cable. removal of trench cover and its fixing & all other associated works to complete the lob satisfactorily.
Maintenance of mulsyfire system and fire hydrant including control panel, indication panel, jockey pump, compressor headers, complete pipe line, deluge valve, piping ring mains on 2 nos T/F & 12 volt battery with charger with all associated work complete as per technical specification enclosed.
Cleaning & checking outdoor and indoor unit, cleaning of air filter of 2Ton capacity Hitachi make split air condition with nylon brush, soap and water and repairing of deteriorated filter if required with skilled technician.
Checking of leakage for R-22 (Freon) gas and brazing of any leakage joint perfectly of 2 Ton split AC and all other associated work including cost of material and skilled labour
Recharging of R-22 (Freon) Gas in sufficient quantity in compressor of 2 Ton Split AC including cost of material and skilled labour.
Providing /Repairing of auto transformer and control circuit (PCB) and OEN relay of 15 A -230V stabilizer. Module VC500
Replacement/repair of fan motor for various air conditioners of 2 Ton split AC type Hitachi make.
Repairing of cooling fan motor of 220/132 KV 160 MVA Power Transformer, 132/33 KV, 40/63 MVA Power Transformer
Replacement of compressor of 2 Ton split type AC including of material and skilled labour.
KRISHNA ENTERPRISES
SSK ENGINEERS
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .