| # | Company | Quoted % | Amount | Rank | Status |
|---|---|---|---|---|---|
| 1 | L1₹18.8 LAdmitted-Finance | -47.77% | ₹18.8 L | L1 | Admitted-Finance |
| 2 | L2₹19.7 LAdmitted-Finance | -45.30% | ₹19.7 L | L2 | Admitted-Finance |
| 3 | L3₹20.6 LAdmitted-Finance | -42.87% | ₹20.6 L | L3 | Admitted-Finance |
| 4 | L4₹21.6 LAdmitted-Finance | -40.11% | ₹21.6 L | L4 | Admitted-Finance |
| 5 | L5₹21.6 LAdmitted-Finance | -40.00% | ₹21.6 L | L5 | Admitted-Finance |
Tender Value
₹36 L
EMD Value
₹72,000
Closing Date
9 Feb 2026, 6:00 pmClosed
Executive Engineer PWD(RandB)nagrota Jammu
Executive Engineer PWD(RandB)nagrota Jammu
Construction of 02-No ACR (Senior Secondary) at HS Surinsar (Under PAB 2025-26 Samagra Shiksha).
2026_PWDJK_301701_3
short e nit 77 of 2025-26 dated 28-01-2026
Open Tender
Civil Works - Roads
60 days
Executive Engineer PWD(RandB)nagrota Jammu
Please refer Tender documents.
2 documents required · 2 mandatory
₹600
Executive Engineer PWD(RandB)nagrota Jammu
₹72,000
21 Feb 2026
29 Jan 2026
10 Feb 2026
29 Jan 2026
9 Feb 2026
29 Jan 2026
Demolishing RCC work manually/ mechanical means including stacking of steel bars and disposal of unserviceable material within 50m lead.
Demolishing brick work manually or by mechanical means including stacking of servicable material and disposal of unservicable within 50m lead in cement mortar
Demolishing cement concrete manually or by mechanical means including disposal of material within 50 metres lead 1:3:6 or richer mix
Demolishing cement concrete manually or by mechanical means including disposal of material within 50m lead. 1:4:8 or leaner mix
Earth work in excavation by manual means in trenches for foundations, drains, pipes, cables etc. (not exceeding 1.5 m in width) and for shafts, wells, cesspits and the like not exceeding 10 sqm on plan, including dressing of sides and ramming of bottoms lift upto 1.5 m, including getting out excavated earth and disposal of surplus excavated earth as directed: All kinds of soil :
Providing and laying in position cement concrete of specified grade including curing but excluding the cost of centring and shuttering. All work upto plinth level with: 1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size)
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering. All works upto plinth level in (1:3:6) grade with 20mm nominal size of crushed stone aggre-gates.
Providing and laying in position specified grade of reinforced cement concrete excluding the cost of centering. shuttering, finishing and reinforcement-All work upto plinth level 1:1.5:3 (1 cement: 1.5 coarse sand: 3 graded stone aggregate 20mm nominal size)
Reinforcement for RCC work including straightening cutting, bending,placing in position & binding all complete TMT bars.
Centering and shuttering including strutting, propping etc. and removal of form work for:
Foundations, footings, bases for columns
Lintels, beams, plinth beams, girders, bressumers and centilevers.
Columns, pillars, piers, abutments, posts and struts.
Suspended floors, roofs, landings, balconies and access platforms.
Edges of slabs and breaks in floors and walls Under 20 cm wide
Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundation etc. Layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering lead upto 50m and lift upto 1.5m.
Reinforced cement concrete work in walls (anythickness), including attached pilasters, buttresses,plinth and string courses, fillets, columns, pillars, piers, abutmen"ts, posts ans sturts, etc. upto floorfive level excluding cost of centring, shuttering, fmishing and reinforcement. 1:1.5:3 (1 cement : 1.5 coarse sand : 3 graded crushed stone aggregate 20mm nominal size
Providing and laying reinforced cement concrete 1:1.5:3 (1 cement:1.5 coarse sand: 3 graded stone aggreate 20mm nominal size in suspended floors , balconies, landings and staircase having upto 15 degree slope excluding cost of centering and shuttering. All work upto floor V level.
Brick work with common burnt clay F.P.S.(non-modualar) bricks of class designation 75 in foundation and plinth in Cement mortar 1 :6 ( 1 cement : 6 coarse sand) & Extra for brick work in superstructure above plinth level upto floor V level. (By manual means)
Providing and fixing pressed steel door frames conforming to IS: 4351, manufactured from commercial mild steel sheet of 1.60mm thickness, including hinges jamb, lock jamb, bead and if required angle threshold of mild steel angle of section 50x25mm, or base ties of 1.60mm pressed, mild steel welded or rigidly fixed together by mechanical means, including M.S pressed butt hinges 2.5mm thick with mortar guards, lock strike-plate and shock absorbers as specified and applying a coat of approved steel primer after pre-treatment of the surface as directed by Engineer in-charge: Profile B
Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc including priming coat with approved steel primer all complete Fixed to steel windows by welding
6 mm Cement plaster to ceiling of mix 1 : 3 ( 1 cement : 3 fine sand)
12mm cement plaster of mix 1:6 (1 cement : 6 fine sand)
15 mm Cement plaster on the rough side of single or half brick wall of mix 1:6 (1 cement:6 fine sand)
Half brick masonry with common burnt clay (non-modular) bricks of class designation 7.5 in foundations and plinth including curing in : Cement mortar 1:4 ( 1 cement : 4 coarse sand)
Providing and fixing panelled or panelled and glazed shutters for doors, windows and clerestory windows fixing with butt hinges of required size with necessary screws, excluding panelling which will be paid for separately, all complete as per direction of Engineer-in-charge. (Note: -Butt hinges and necessary screws shall be paid separately). 35 mm Thick Second class deodar wood
Providing and fixing glazed shutters for doors, windows and clerestory windows using 4mm thick float glass panes including ISI marked M.S. pressed butt hinges bright finished of required size with necessary screws.30mm thick Ist class kail wood
Providing and fixing panelling or panelling and glazing in panelled or panelled and glazed shutters for doors, windows and clerestory windows (Area of opening for panel inserts excluding portion inside grooves or rebates to be measured). Panelling for panelled or panelled and glazed shutters 25 mm to 40 mm thick Plain particle board flat pressed, 3 layer or graded wood particle board medium density
Providing and fixing wooden moulded beading to door and window frames with iron screws, plugs and priming coat on unexposed surface etc. complete: Kiln seasoned and chemically treated hollock wood 50x12mm
Providing and Fixing Fan of Anchor or Crompton make of 1200 mm including Testing. Commissioning Complete.
Providing and Fixing Fan Electric Points Complete in all respect as per necessary as site.
S/I Fan Regulator.
Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622 of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1cement :4 coarse sand) including grouting the joints with white cement and matching pigments etc. complete Size of tile 600x600 mm
Making plinth protection 50mm thick with cement conc .(1:3:6) ,20 mm nominal size of stone aggregates over 75mm bed of dry brick ballast,40mm nominal size of well rammed and consolidated and grouted with fine sand including finishing the top smooth.
Providing and fixing hardware fixtures (Aluminium) ISI marked anodised (Anodic coating) not less than grade AC 10 as per IS-1868
Sliding door bolts (300 x 16mm)
Tower bolt150x10mm
Tower bolt100x10mm
Handle 125mm
Stopper twin type
Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface.
Wall Painting with acrylic emulsion paint of approved brand and manufacture to give an even shade. Two or more coats on new work
Applying priming coat with ready mixed pink or grey primer of approved brand and manufacture on wood work (hard and soft wood)
Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade. Two or more coats on new work.
Providing and fixing on wall face unplasticised- PVC moulded fittings / accessories for unplasticised - Rigid PVC rain water pipes conforming to IS: 13592 Type A including jointing with seal ring conforming to IS : 5382 leaving 1 0 mm gap for thermal expansion. 110 mm bend
Engagement of painter for writing name of school and making logo etc
Carriage of material by Mechanical Transport including loading/unloading and stacking at site complete.
Sand for an av. Lead 15.00 Km.
Bajri for an av. Lead 15.00 Km.
Bricks for an av. Lead 25.00 Km.
Please Enable Macros to View BoQ information
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.42 MB
BOQ_978881.xls
BOQ • 0.29 MB
Download all tender documents and submit your bid