Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹49.4 LAccepted-AOC | L1 | Accepted-AOC Awarded | |
| 2 | L2₹55.9 L+₹3.9 L (7.49%)Rejected-Finance | L2 | Rejected-Finance Rejected |
Tender Value
₹49.5 L
EMD Value
₹99,000
Closing Date
15 Dec 2023, 6:00 pmClosed
GE (AF) Subroto Park
GE (AF) Subroto Park c o 56 APO
SPECIAL REPAIR TO CAMERO SNCO MESS AND CERTAIN LIVING IN ACCOMMODATION AT CAMERO SNCO MESS AND PROVN OF WALL MOUNTED FAN FOR VARIOUS OFFICES OF AFRO AT SUBROTO PARK
2023_MES_618460_3
GE/SP/ TOKEN-55/2023-24
Open Tender
Civil Works
Item Rate
120 days
GE (AF) Subroto Park
Please refer Tender documents.
10 documents required · 10 mandatory
₹500
GE (AF) Subroto Park
₹99,000
Yes
22 Dec 2023
24 Nov 2023
18 Dec 2023
24 Nov 2023
15 Dec 2023
2 Dec 2023
Amount
Taking down frame or chowakhats (w/o taking off shutter from the frame ) of any description exc. 1.50 sqm and not exc. 4.00 sqm each complete all as specified
S&F for 35 mm thick II nd Class hardwood Glazed and skeleton shutters,(minimum 8 panels) open rebated and with prepared to receive wire cloth (gauze), etc. (without sash bars), edges of framing plain, chamfered or rounded. fitted with cut and mitred beads for securing glass, etc.; sizes of me-mbers of shutters as specified in SSR Part I, Section 8, clause 8.24 (a); supplied and fitted to chowkats
S & F 35mm factory made plain framed, panelled shutter (without interlocking rail and with one panel only) with lock rail and panel of 9 mm B.W.P. commercial ply or 12 mm veneered particle board with commercial veneering on both faces. The size of rail and stile as per IS : 1003 (Part I), kiln seasoned and chemically pressure treated
S&F for size 105x60mm Pressed steel frames for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate, etc., complete as specified,
S&F for size 125 x 60 mm Pressed steel frames for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate, etc., complete, as specified complete all as spd.
M & L for cement concrete type C1, 1:3:6 (20 mm graded aggregate) in door and windows frames, any size, single or double rebated, including arrangement for fixing of hinges and fixtures as required complete all as specified and directed by Engr-in-charge.
Taking down frame or chowakhats (w/o taking off shutter from the frame ) of any description not exc. 1.50 sqm each complete all as specified
S&F solid PVC Door Frame of size 50mm x 47mm made out of 5mm wood grain printed PVC sheet used instead of Plain colour PVC sheet & edges will be painted to match with printed sheet PVC sheet reinforced with M.S. Square tube, suppling & fixing in opening as per specification
S&F Factory Made Solid PVC Moulded Door Shutter, 28 to 30mm thick (stiles), with 2, 4, or 6 raised panel design with 2mm thick 3D wood grain Moulded PVC Sheet Polyurethane painted on the front face & 2mm prelam PVC Sheet on back face complete all as specified.
S & F for aluminium powder coated frame work any colour (minimum thickness of powder coating 50 micron) for doors, windows, ventilators with one or more rebates including joining cleats for fixing etc complete all as specified.
S & F for aluminum powder coated any colour (minimum thickness of powder coating 50 micron) aluminium window and ventilator shutters/partician, side hung type without sash bars, aluminium sections weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws, powder coated aluminium fittings such as peg stays 150mm long (1 no.). hinges type B-21 100mm long (2 no.) suitable handle (1 no.) complete all as specified
S & F aluminium deco grills conforming to DG-104 grade all as specified and directed by Engineer-in-Charge.
S & F for aluminum powder coated any colour (minimum thickness of powder coating 50 micron) as in door shutters, aluminium section weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber neoprene packing, handles 2 Nos in each door, hinges, anodised aluminium snap beading screws etc. complete all as specified.
S & F prelaminated particle board 12mm thick, exterior grade, prelaminated both side with decorative choice laminations fixed with aluminium glazing clips as in door shutter/partitions etc complete all as specified and directed by Engineer-in-Charge.
S&F brass body mortice lock vertical type size 100mm 4 lever, including escutcheon plate and two No keys fixed complete all as specified and directed by Engr-in-Charge.
S& F Aluminium (extruded section body) Door closer hydraulically regulated, designation No. 3, universal type, suitable for door shutters of 851 to 1000 mm in width and of weight between 61 to 80 kg and fixed
S&F 150mm long Aluminium anodised, barrel tower bolts of ex- truded section and fixed complete all as specified.
S&F 150mm long aluminium handle cast type polished bright.
S&F 100 mm long butt hinges medium weight, cold rolled mild steel, and fixed complete all as specified.
S&F for Stainless steel wire cloth. 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples complete all as specified and directed by Engr-in-charge.
S&F for 250mm long Aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy complete all as specified and directed by Engr-in-charge.
Demolition of brick work or stone/boulder masonry built in cement mortar all as specified.
M&L for brick work with subclass B bricks, straight or curved on plan to any radius built in CM 1:6 all as specified
M&L for brick work with subclass B bricks, straight or curved on plan to any radius in half brick thick wall built in CM 1:4 all as specified
M&L for guiniting work to RCC work in coloumn, chajjas, balconies, slabs, landings etc by removing loose, concrete, incl removing rust with short blasting and cleaning of surface with wire brush and applying epoxy treatment to rusted reinforcement and including S&F welded wire mess fabric or wire not less than 95x95x3mm adhesive plaster grade for concrete admixture and providing guniting pressure 2.00/2.50 Kg/Sq cm with admixture 1 part of cement and 3.50 part of sand and thickness 50mm average and making the surface even and smooth including necessary formwork and 10mm thick with CM 1:4 plaster over repaired surface with WPC complete all as specified and directed by Engr-in-Charge.
Taking down cement or cement lime plaster on brick walls incl racking out joints hacking for key scrubbing down with water etc up to 4th stories complete all as specified and as directed by Engr-In-Charge.
M&L for rendering 15 mm thick in CM (1:4) on fair faces of brick surfaces or concrete surfaces even and smooth without using extra cement with using water poofing compound up to 4th stories complete all as specified and as directed by Engr-In-Charge.
M&L for rendering CM (1:6) 15 mm thick on fair faces of brick work or concrete surfaces surface even and fair without using extra cement up to 4th stories complete all as specified and as directed by Engr-In-Charge.
M&L for rendering 5mm thick in CM (1:3) on concrete surfaces of ceiling, even and smooth without using extra cement up to 4th stories complete all as specified and as directed by Engr-In-Charge.
M&L for preparation on new plastered or unplatered surfaces of walls and applying two coat of exterior Apex/weather coat over a coat of primer any tint (colour as approved by GE) over putty including preparation of surface of wall, band/chajja/balcony up to four storey height building complete all as specified and dircted by Engineer in charge.
M&L for preparation on old plastered or unplastered surfaces of walls and applying two coat of exterior Apex/weather coat over a coat of primer any tint (colour as approved by GE) over putty including preparation of surface of wall, band/chajja/balcony up to four storey height building complete all as specified and dircted by Engineer in charge.
M&L for preparation of newly plastered or unplastered surface and applying two coats of distemper oil emulsion on walls over a coat of primer incl 3mm thick wall care putty on walls/ceiling upto 4 story bldg complete all as specified and directed by Engr-In-Charge.
M&L for complete removal of existing treatment and applying two coat of oil bound distemper white or tinted on wall complete all as directed and specified.
M&L factory made precast PCC kerb stone of size 30cmx15cmx30cm or 30cmx15cmx45cm manufactured by M-30 grade of concrete fixed on 75mm thick PCC (1:2:4) using 20mm graded stone aggregate, jointed with cement mortar (1:4) including necessary excavation ,returning filling,1mm thick wall care putty ,2 coats of exterior emultion over a coat of primers of existing kerb stone including dismantling complete all as specified and directed by Engr-In-Charge..
M & L for 75 mm thick PCC 1:3:6 type C2 as in Plinth Protection/hard standin/path using 40 mm stone aggregate including making joints & filling with sand bitumen mastic as per including dismantling complete all as specified and directed by Engr In Charge.
M&L Preparation of new steel surfaces of any description, over 10 cm in width or girth, not otherwise described and applying two coat of synthetic enamel paint over a coat of red oxide/ zinc chromate,complete all as specified.
M&L for one coat of synthetic enamel paint including prepration of old steel surfaces complete all as specified and directed by Engr-in-charge.
M&L Preparation of new wooden surfaces of any description, over 10 cm in width or girth, not otherwise described and applying two coat of synthetic enamel paint over a coat of pink primer,complete all as specified.
M&L one coats of synthetic enamel paint including prepration of old wooden surfaces complete all as specified and directed by Engr-in-charge.
Dismantling stone slab and granite of any description or thickness in floors etc and removing the debries outside the MOD land complete all as specified and directed by Engineer-in-Charge.
M&L for PCC 1:2:4 type B-1(20mm graded aggregate),25mm thick as in sub base to the tile flooring complete all as specified.
M&L for machine cut kota stone slab flooring 20-25 mm thick laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing and 15mm thick screed bed or bedding layer of cement mortar 1:4 complete all as specified.
All as per item No 43 above but in skirting over 10 mm thick rendering in cement mortar 1:4 complete all as specified.
M&L for 20 mm thick granite stone (any type) machine cut, bedded and jointed with grey cement slurry and pointed with white cement with admixture of pigment (1:2) to match the shade of stone including cutting and polishing as in floors laid over 15mm thick screed bed in cement mortar 1:6 complete.on cooking / working platform
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing) removing serviceable tiles to store and rubbish off the premises complete all as specified.
M&L for colored Glazed ceramic tiles in vertical surface 350x 250x 7 mm/ 450X 350X 7mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match over 15 mm thick screed bed or bedding layer in cm (1:4) complete all as specified.
M&L non skid ceramic coloured printed tiles 7 to 8 mm thick (square/rectangular) area of each tiles exc 0.11 sqm but n. exc 0.18 sqm, in floors etc set and jointed in neat cement slurry and pointed in coloured cement to match over 15 mm thick screed bed or bedding layer in cm (1:4) complete all as specified.
M&L Vitrified Ceramic light shade tiles 9 to 10 mm thick (square/ rectangular) polished, area of each tiles not exceeding 0.36 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match flooring( in any pattern) and jointed with coloured cement matching with surfaces of tiles as in floor 15 mm thick cement screed in CM 1:6 and pointed with coloured cement matching with surfaces of tiles as in floor complete all as specified and directed complete all as specified and directed
All as per item No 49 above but as on vertical surface of wall such as skirting/dado including 10mm thick cement plaster (1:4) as in backing coat of tiles complete all as specified and as directed
M&L for exterior (out door) wall tiles 350mX250mmX7 to 8mm or 350X 450X 7mm to 8mm thick on vertical surface, jointed in neat cement slurry and pointed in white or colour cement to match with tiles incl back plaster 10 mm thick in cm 1:4 with WPC complete all as specified and directed by Engr In Charge.
Taking out of APP modified water proofing membrane including mud puska/bricks complete on roof surface and surface properly cleaned by wire brush complete all as specified and as directed by Engineer-in-Charge.
M&L for cement concrete tiles 20cmX20CMX20MM thick with grey cement and no pigment machine pressed; set jointed and pointed in neat cement slurry in floors and cut and polished completed all as specified and directed by Engr-In-Charge.
M & L 20 mm thick screed bed or bedding layer of cement mortar (1:4), for laying of cement tiles on roof complete all as specified and directed by Engr In Charge.
M&L for preparation of plastered/concrete surfaces of roof and applying the under mentioned course of roof treatement complete all as specified and directed by Engineer-in-Charge.:- (a) Surface shall be throughly wire brushed, cleaned, washed, dried up properly and apply evenly a bituminuous primer coat conforming to IS @0.4 ltr /Sqm over concrete / plastered roof surface.(b) Applying evenly a tack coat of bitumen 85/25 grade @1.20 kg/ sqm.(c) Laying of 3mm thick APP membrane sheet (min weight 3 Kg/Sqm) consisting of a core of 160 gms/Sqm polyster non woven fabric mat protected on both sides with a high quality polymeric asphaltic mix again protected with thermo fusible HMHDPE FILM on dried primed surface by torch application method. APP membrane will normally be laid in length at right angle to the direction of slope. The over lap shall be minimum 100mm on longitudinal direction and 150mm on the transverse direction including cuttings, grooves etc.(d) Membrane bonded completely to the substrate & the over laps are then scaled/fused by flame.(e) Including 10mm thick rendering with 1:4 using WPC. Note:- This treatement shall be done by the approved authorized applicators and guarantee of treatement shall be for 10 years. (ii) Independent testing of membrane for the approved technical parameters specified herinafter shall be carried ourt from the approved laboritries any other Govt approved laboratory having facilities for the testing membrane. APP membrane shall have following parameteres:- (i) Tear strength :- Longitudnal direction-300N, Transverse direction-250N (ii) Joint Strength :- Longitudnal direction- 650N, Transverse direction-450N
M&L for PCC 1:2:4 type B1 using 20mm graded aggregate mixed with water proofing compound as per manufacturer instructions laid as in padding over roof slabs for providing proper slope to the concrete padding, surface finished even and smooth without using extra cement complete all as specified.
M&L for PCC 1:2:4 type B0 (using 12.5mm graded aggregate) roof kerbs, benching rounded or chamfered on edge including rounded or chamfered edges with necessary form work etc complete all as specified and directed by Engr-in-charge.
Demolition of un-reinforced Cement Concrete of any description and in any position not otherwise specifically provided complete all as specified and directed..
M&L for 100mm thik cement concrete 1:4:8 type D2 (using 40 mm graded stone aggregate) as in sub base for floors finishes complete all as specified and directed by Engr-in -Charge.
S&F precast machine pressed PCC interlocking paver block of 80 mm thickness, M-40 grade of any shape and size confirming to IS -15658-2006 with grey cement and pigment as approved including dismentling complete all as specified and directed by Engineer-in-Charge.
M&L for sand filling under floors or in foundations including watering and consolidation complete all as specified and directed.
M&L for Chequered glossy finished cement concrete coloured tiles (300 X300) 20-25mm thick confirming to IS -1237 (rubber moulded) in floor setc, set, jointed & pointed with cement slurry 15mm thick bedding layer of cement sand mortar (1:6) complete all as specified by Engr-in-Charge.
Taking down or steel water tubing along with fittings connections incl cleaning for reusing or removing complete 15 mm bore complete all as specified.
Taking down or steel water tubing along with fittings connections incl cleaning for reusing or removing complete 20 mm bore complete all as specified.
S&F medium grade galvanising steel water tubing ISI marked with all fittings and fixed to walls and ceiling or laid in floors15 mm bore complete all as specified.
S&F medium grade galvanising steel water tubing ISI marked with all fittings and fixed to walls and ceiling or laid in floors20 mm bore complete all as specified.
S&F in repairs 15 mm bore bib taps chromium plated and fancy type with crutch or butter fly handle high pressure screwed down for pipes etc complete all as specified.
S&F in repairs15mm dia stop/angle valve but fancy type chromium plated with long shank and cup (Concealed type) screwed down, high pressure, with crutch or butterfly handle screwed both ends for iron pipe or for unions and fixed complete all as specified.
S&F in repair factory made SFRC manhole / drain cover (Grade M-25) heavy duty cover slab in rectangular shape of size as required, 80 mm thick incl MS sheet 2 mm thick all around the cover including demolition of cover, complete all as spefcified and directed by Engr - in - charge.
S&F in repairs,15 mm pillar taps, cast copper alloy, with capstan heads, chromium plated screwed down high pressure, with or without lettered "Hot" or Cold with long screwed shanks and fly nuts screwed for iron pipes and fixed , fancy type complete all as specified.
S&F in repair counter top oval wash basin, Size - 450 x 400mm incl waste coupling & PVC waste pipe. complete all as specified and as directed by Engr-In-Charge.
S&F in repair for vitreous china urinal half stall type white complete all as specificed and directed by Engr-in-Charge.
S&F vitreous china squatting (Orissa pattern) water closet of size 580x440mm white , with integral foot rests ( excluding flushing cistern and flush [pipe) complete incl. trap and connection to trap and flush pipe antisyphonage pipes. Incl. Proven of lime concrete bedding and making good to floor fixed in repairs complete all as specified.
S/F in repairs viterious china wash down water closet pan (Pedestal pattern) white (excluding fixing bolts, flushing cistern and flush pipe)incl P or S trap etc complete all as specified and as directed by Engr-In-Charge.
S&F in repairs 10 litre capacity PVC low level flushing cistern complete with symphonic handle lever pvc bend incl. Connecting to wc and fixed to walls with bracket duly painted complete all as specified.
S&F 100 mm dia PTMT Grating complete all as specified.
S&F 15mm dia PVC Connection 450 mm long with nuts complete all as specified.
S&F in repairs chromium plated shower rose 125 mm size with or without swivel joints complete all as specified.
S&F in repairs CP Towel rail 450mm long fixed with and including chromium plated brass screws and wooden/plastic cleats complete all as specified
S&F in repairs soap dish, cromium plated fixed to plugs with chromium plated brass screws etc complete all as specified
S&F of glass shelf assembly consisting of 5.5 mm thick sheets glass shelf 12cm wide with chromium plated bracket guard and railing 60cm long complete all as specified
S&F in repair stainless steel sink with drainage board made out of 1mm thick sheet for kitchen or laboratory with plug, washer, waste etc including cast iron brackets, connecting union over all size 915mm X 460mm with bowl size 410mm X 330mm X 160mm complete all as specified and directed by Engr-in-charge.
M&L for PCC (1:5:10) type E-2 using 40 mm graded brick aggregate as in sunken portion complete all as specified and as directed
M &L for removing building materials etc. (other than spoil payable under items 03028 to 03031 in Section-3—Earthwork) to a distance of 15km, beyond the lead included in the rates, including loading, unloading and stacking at the destination complete all as specified and directed by Engineer-in-Charge.
Material and labour for false ceilings using GI snap grid system with roll-formed out of hot dip galvanised steel caping (powder coated) main runner 38 x 24 mm , cross Tee 29 x 24 mm and wall angle 24 x 24 mm members suspended with 4mm dia GI wire, carry maximum load up to 8.10 Kg/Sqm with 4mm thick designer ceiling board , pre painted Gypsum Board 12mm thick in ceiling fixed with screw as per manufacturers instructions size 595 x 595mmx 4mm thick any texture (Lake and Hill, oceaniccascade or Electra) as approved by GE all as per , Everest Ceiling grid system 'Regular T-2430' or its equivalent make of "'Ramco, Charminar/Armstrong'' at any height including dismantling complete all as specified and as directed by Engr-In-Charge.
M &L for PVC profile for wall panelling colour / shade as approved size 250mm wide, 08 mm over all thick with 1 mm wall thickness fixed with screw to mild steel square ( size 20mmx 20mmx 1mm thick) tubler frame work including one coat of red oxide primer, fixed to walls and including dismentling complete all as specified and directed by Engr-in-Charge.
M&L for PVC profile corner beading L/T type for wall panelling, colour/shade matching with wall panelling complete all as specified and directed by Engineer-in-Charge.
S & F of rolled mild steel sections as in main and cross beams, hip and jack rafter, purlins where connected to common rafters, running rails, grills, coolar stand, chajja, water tank stand, gate, drain cover, guides for sliding doors fixed with angle cleat and other connecting plates conforming to Fe-290 Grade E-165 including dismantling complete all as specified and directed.
S&F Rotational moulded polyethylene 1000 Ltr water storage tanks triple layer as per IS (cylindrical vertical with closed top) hoisted and fixed in position including dismantling water tanks exc 500 but not exc 1000 ltrs capacity and removing to store complete all as specified and directed by Engr In Charge.
S&F in repair 20mm dia ball brass valves, high pressure, with polythene float and flynut complete, screwed for iron pipe or brass ferrule and fixed complete all as specified and as directed by Engr-In-Charge.
Taking down rainwater pipes (any size or pattern), including all fittings, heads, shoes, bends, swan-necks, etc., including cleaning or refixing or removal to Store (measured overall as fixed along the centre line over fittings and accessories)
S&F PVC (SWR) pipes 150 mm single socketed, in any length with solvent cement joints fixed to walls/laid in floors incl stack clamps of stainless steel with bolts & nuts etc .
All as per item No 93 above but 110 mm dia.
S&F in repair PVC SWR floor trap with grating including jointing with solvent cement 110 mm dia complete all as specified and directed by Engr-in-charge.
S&F in repair PVC SWR bends 150 mm complete all as specified and directed by Engr-in-charge.
S&F in repairPVC SWR bends 110 mm complete all as specified and directed by Engr-in-charge.
S&F in repair PVC SWR Junction piece 110 mm double (Double T) provided with access door equal or unequal.
S&F in repair 150 mm PVC SWR Junction single (Single T) provided with access door.
S&F in repair PVC SWR vent cowl of size 150 mm.
S&F in repair PVC SWR vent cowl of size 110 mm.
Demolition of cement concrete in sunken portion in any position not otherwise specifically provided for complete all as specified and directed by Engineer-in-Charge
M&L providing and making fillet of 75mmx75mm in size with cement concrete in 1:2:4 in sunken portion including applying the under mentioned course of sunken treatement complete all as specified and directed by Engineer-in-Charge.:- (a) Surface shall be throughly wire brushed, cleaned, washed, dried up properly and apply evenly a bituminuous primer coat conforming to IS @0.4 ltr /Sqm over concrete / plastered surface. (b) Applying evenly a tack coat of bitumen 85/25 grade @1.20 kg/ sqm. (c) Laying of 3mm thick APP membrane sheet (min weight 3 Kg/Sqm) consisting of a core of 160 gms/Sqm polyster non woven fabric mat protected on both sides with a high quality polymeric asphaltic mix again protected with thermo fusible HMHDPE FILM on dried primed surface by torch application method. APP membrane will normally be laid in length at right angle to the direction of slope. The over lap shall be minimum 100mm on longitudinal direction and 150mm on the transverse direction including cuttings, grooves etc. (d) Membrane bonded completely to the substrate & the over laps are then scaled/fused by flame. (e) Including 10mm thick rendering with 1:4 using WPC. (f) Painting with two coats of water proofing paint with aluminium finish.
M&L for Refilling Lime concrete with brick aggregate (Course) in lime mortar1:3, 300mm thick in the sunken with the help of proper tools & equipments & plants.
M&L Providing and making cement concrete in 40mm thickness in 1:2:4 type B0 (12.5mm graded aggregate) mixing Dr Fixit Pidiproof LW+ or equivalent Complete in sunken upto the below level of tiling complete all as specified and directed.
Demolition reinforced cement concrete of roofs, floors (other than ground floors), beams, staircases, landing, chajjas and similar suspended work (reinforcement cut as required to facilitate demolition) complete all as specified and directed by Engineer-in-Charge.
M&L for nominal mix 1:2:4, type B-1 nominal mix 1:2:4, type B-1 using (20mm graded aggreate) in slabs supported on walls, beams and column in floors,roofs,landings,balconies,canopies, deck slabs and in shelves and the like complete all as specified and directed by Engineer-in-Charge
Use and waste of formwork to fair finished surface of sides and soffits of floor or roof beams, beam haunchings, girder, column, bressummers,lintels,cantilevers ,shelevs including supports, overhangs, etc. also splays between floors and beams ,etc complete all as specified and directed by Engineer-in-Charge
Formwork to edges of concrete flats, treads, breaks in floors, window cills, concrete rail ings, openings in concrete walls, floor and roofs n exc 20 cm wide and sides of RCC/ PCC bands in walls, horizon tal or sloping and similar work exc 10cm but n exc 20cm wide complete all as specified and directed by Engineer-in-Charge
M&L for mild steel TMT bars 10mm dia and over cut to length bent to shape required including cranking bending spirally for hooping for columns hooking ends and blinding with and including mild steel wire annealed not less than 0.9mm dia or securing with clips complete all as specified and directed by Engineer-in-Charge
M & L for green marble work 18 to 20mm thick (table rubbed and polished) in steps, jambs, pillars, windowcills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with marble shade of following types complete all as specified and directed by Engineer-in-Charge
S&F factory made 18mm (+0.7mm) thick celuka PVC ply of density 600kg/cbm manufactured by an ISO-900-2008 certified company.One side prelam and other side plain 18mm thick Celuka PVC ply for kitchen cabinet shutter and also manufactures test report and test certificate is mandatory with each and every supply of the material complete as per directions of Engineer-in-Charge,manufacturers specifications and drawing.
S&F factory made 18mm (+0.7mm) thick celuka PVC ply of density 600kg/cbm manufactured by an ISO-900-2008 certified company. Both sides plain 18mm thick Celuka PVC ply for framing purpose and also manufactures test report and test certificate is mandatory with each and every supply of the material complete as per directions of Engineer-in-Charge,manufacturers specifications and drawing.
S&F 100mm size Stainless steel handel complete all as specified and as directed by Engr-in-charge.
M&L for 50mm magnetic catches and fixed complete all as specified and as directed by Engr-in-charge.
S&F 38mm size stainless steel piano hinges complete all as specified and as directed by Engr-in-charge.
S&F for 125mm size of hasp & staple safety type stainless steel with mild steel hinge pin incl bolt to hinges plate and fixed with screws complete all as specified and as directed by Engr-in-charge.
Taking down carefully copper/aluminium point wiring light ,fan, light fittings,socket or power complete, such as switches, ceiling roses, pendents, regulators, sockets etc.removing materials to store for keeping in safe costudy or for taking credit (credit for above items should be made as per conditioned separately) and making good disturbed surface of walls, floors etc. complete all as specified and directed by Engineer-in-Charge.
M&L for point wiring with single core PVC insulated unsheathed 1100 volt grade cable with multi strand copper conductor of size 1.5 Sq mm FRLS (Nominal area) drawn through and including non metallic rigid PVC concealed conduit, medium grade, ISI marked not less than 20mm dia, concealed in wall, ceiling with GI saddles GI screws, rawl plugs (concealed conduit wiring) with all fittings including Tee, Junction boxes and provision of pressed steel terminal modular box powder coated of suitable size for mounting switch sockets and regulators and drawing continuous earth wire of PVC insulated unsheathed 1100 Volts grade cable with stranded copper conductor of size 1.5 Sq mm (Nominal area) complete all as specified. Note: Cost for cutting, chasing and making good to existing surfaces are deemed to be included in the Quoted Rate. (a) For one light point/fan point controlled by one SP switch
All as per item No-119 above but for one 3 pin socket out let, 6 Amps on same board with the cable 1.5 Sqmm size.
All as per item No-119 above but for one 3 pin socket out let, 6 Amps on Independent board with the cable 1.5 Sqmm size.
All as per item No 119 above but with 2.5 Sq mm cable for Independent bd one 3 pin 15 Amps socket outlet including S/C 2.5 Sq mm PVC insulated copper conductor unsheathed 1100 v grade IS -694 FR LS cable for continuous earth wire connected to gang box of required size all as specified and directed by Engineer-in-Charge.
S&F switch piano 6 amps flush type single pole one way suitable for 240 volt AC Complete all as specified and directed by Engineer-in-Charge.
S&F socket outlet flush type 6 pin 6 amps suitable for 240 volt AC Complete all as specified and directed by Engineer-in-Charge.
S&F switch piano 16 amps flush type single pole one way suitable for 240 volt AC Complete all as specified and directed by Engineer-in-Charge.
S&F socket outlet 2 in 1, 5 pin 16 amps flush type suitable for 240 volt AC Complete all as specified and directed by Engineer-in-Charge.
Supply and fixing of ceiling roses, surface bakelite 65x50mm 2 or 3 terminals , PVC/Polycarbonate, isolated body fixed on PVC round block complete all as specified and directed by Engineer-In- Charge.
Supply and fix electronic Fan Regulator rotary flush step type 120 watt, 240 volt complete .
S&F Single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB 20A
S&F Triple pole and earth encolsure with a three pin and earth plug with socket complete with one triple pole MCB
Supply and fixing LED lights fitting 1x 20W, 220V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete.
Supply and fixing LED lights fitting 1x 10W, 220V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete.
Taking down including disconnecting the electric connection of ceiling fan and dismantling blades,greasing complete all as specified and directed
M&L for repairing of ceiling fan any size (including change of bearings/windings with super enamelled copper wire of same size ) replacement of suitable capacity of condenser and testing complete all as specified and directed by Engineer in Charge.
Hanging / fixing only ceiling fan received from item above and connecting up including fastner and provision of suitable size of copper cable from connector of fans to ceiling rose complete.
Taking down including disconnecting the electric connection of exhaust fan and dismantling blades,greasing and painting the whole assembly including marking MES No complete all as specified and directed
M&L for repairing of exhaust fan 450 mm sweep (including change of bearings/windings with super enamelled copper wire of same size ) replacement of suitable capacity of condenser and testing complete all as specified and directed by Engineer in Charge.
Fixing only Exhaust fan received from item above and connecting up including fastner and provision of suitable size of copper cable from connector of fans to ceiling rose complete all as specified and directed by Engr-in-charge.
M &L for submain wiring with two run of 4.0 sqmm single core PVC insulated but unsheathed FRLS cable of specified size of multistranded copper conductor 1100 volts grade IS:694 marked and one run of 4.0 sqmm PVC insulated but unsheathed FRLS cable for earth continuty conductordrawn through and under suitable size of rigid non metallic PVC conduit , medium grade, ISI marked ( not less than 20 mm dia) complete with all acessories and fittings all laid/fixed concealed in wall/ceiling and surface conduit on ceiling, and also include the specified runs of specified size earth continuity conductor of similar type cable complete all as specified - 3 Runs of 4.0 Sqmm single core and one run of PVC conduit shall be measured as one unit length.
M & L for submain wiring with two run of 6.0 sqmm single core PVC insulated but unsheathed FRLS cable of specified size of multistranded copper conductor 1100 volts grade IS:694 marked and one run of 6.0 sqmm PVC insulated but unsheathed FRLS cable for earth continuty conductordrawn through and under suitable size of rigid non metallic PVC conduit , medium grade, ISI marked ( not less than 20 mm dia) complete with all acessories and fittings all laid/fixed concealed in wall/ceiling or surface in wall and surface conduit on ceiling, and also include the specified runs of specified size earth continuity conductor of similar type cable complete all as specified - 3 Runs of 6.0 Sqmm single core and one run one run of PVC conduit shall be measured as one unit length.
M & L for submain wiring with two run of 10.0 sqmm single core PVC insulated but unsheathed FRLS cable of specified size of multistranded copper conductor 1100 volts grade IS:694 marked and one run of 10.0 sqmm PVC insulated but unsheathed FRLS cable for earth continuty conductordrawn through and under suitable size of rigid non metallic PVC conduit , medium grade, ISI marked ( not less than 20 mm dia) complete with all acessories and fittings all laid/fixed concealed in wall/ceiling or surface in wall and surface conduit on ceiling, and also include the specified runs of specified size earth continuity conductor of similar type cable complete all as specified - 3 Runs of10.0 Sqmm single core and one run of one run of PVC conduit shall be measured as one unit length.
Taking down unserviceable submain wiring of alluminium two runs of any size cable including batten/conduit complete etc and making good distrub surfaces complete all as specified and directed.
Taking down old unsv MCB/ DB/ TPN type of any size.
Supply and fixing load line vertical distribution board 'A' frame made out of CRCA sheet,double door, surface mounting TPN 6 way 415 volts 125 Amps rated bus bar and stove enamels dust and vermin proof suitable forTP/FP 'A' frame MCCB of 40/63 Amps =01 No MCCB for outgoing complete all as specified and as directed by Engineer-in-Charge. Note :- MCB shall be measured and paid seperately.
Taking down old unsv MCB DB SPN type of any size.
Supply and fixing MCB distribution board with Bus bar 200A neutral link , earth bar made out of CRCA mild steel sheet surface mounting SPN 12 way 230 volts double door type complete all as specified and as directed by Engineer-in-Charge. Note :- MCB shall be measured and paid seperately.
M&L for earthing complete with GI earth plate electrode 60cmx60cmx6.3mm thick buried directly in ground (earth pit not less than 2.25 meter deep below normal ground level) with top edge of the plate not less than 1.5 meter below normal ground level, connected to and including galvanized iron strip 4 mm dia as earth lead by means of GI bolts, nuts, check nuts and washers earth pit surrounded by picked layer of coal dust and 15 mm thick mixture in equal ratio of magnesium sulphate & copper sulphate in all around bottom and top and watering pipe 20mm bore of GI medium grade with funnel all as shown in electrical plate NO 5 of SSR Part I (1991) and connecting to earthing test point, including CI cover, frame and PCC (1:3:6) type C-2 using 20mm graded stone aggregate as in earthing pit with CI cover and framing including necessary earth work etc, complete all as specified Note :- PCC chamber shall be constructed at least one meter away from building shall be provided in slanting manner. Note :- PCC pit cover shall be precast of RCC 1:2:4 type B-I 80 mm thick reinforced with XPM weighting not less than 4 Kg (sqm in liew of CI)
M&L in replacement of earth contuinity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit / pipe or fixed to poles or any other indicated situation for loop earthing etc as required 4 mm dia galvanized iron or steel wire complete all as specified and directed by Engineer-in-Charge.
Supply and fix in replacement of fixed thermal and fixed magnetic settings, 4 pole MCCB 100 Amps, 50 HZ, 415 volts with rupturing capacity 16 KA complete all as specified and directed by Engineer-in-charge.
Supply and fix in replacement of fixed thermal and fixed magnetic settings, 4 pole MCCB 40 Amps, 50 HZ, 415 volts with rupturing capacity 16 KA complete all as specified and directed by Engineer-in-charge.
Taking down unserviceable SP MCBs of any capacities from the MCCB DBs /MCB DBs after disconnecting the electric supply,complete all as specified.
Refixing the SP MCBs received from above item complete all as specified.
S&F MCB SP 5 to 32 Amps 10 KA, 240 volt 'B' Series all as specified and directed by engineer-in-charge.
Taking down unserviceable SPN MCBs of any capacities from the MCCB DBs /MCB DBs after disconnecting the electric supply,complete all as specified.
Refixing the SPN MCBs received from above item complete all as specified.
S&F MCB SPN 32 Amps 10 KA, 240 volt 50 HZ 'C' Series all as specified and directed by engineer-in-charge.
M&L for taking down existing geyser carefully without damaging of any capacity from bathroom and to be kept in safe custody untill completion of finishing work and re-fixing the same after completion of finishing work including cleaning the geyserr and marking MES No, connecting,testing complete all as specified and as directed by Engr-in-Charge.
M&L for point wiring with single core PVC insulated unsheathed 1100 volt grade cable with multi strand copper conductor of size 1.5 Sq mm FRLS (Nominal area) drawn through and including non metallic rigid PVC casing/caping, medium grade, ISI marked not less than 20 mm dia, concealed in wall, ceiling with GI saddles GI screws, rawl plugs (concealed conduit wiring) with all fittings including Tee, Junction boxes and provision of pressed steel terminal modular box powder coated of suitable size for mounting switch sockets and regulators and drawing continuous earth wire of PVC insulated unsheathed 1100 Volts grade cable with stranded copper conductor of size 1.5 Sq mm (Nominal area) For one light C/Fan/Exhaust/ Wall fan point controlled by one SP switch complete all as specified. Note: Cost for cutting, chasing and making good to existing surfaces are deemed to be included in the Quoted Rate.
S&F socket outlet, 2 in 1, 3 pin 5 amp flush type suitable for 240 V AC complete all as specified.
S&F wall mounting fan 450 mm sweep 230 Volt, rated motor speed not more than 1400 RPM, pull cord type 3 step regulator, pull cord type oscillation and mechanism for upwad and downword adjustment including necessary fixing arrangement for proper fixing in wall as per site requirement complete all as specified.
M & L for submain wiring with two run of 2.5 sqmm single core PVC insulated but unsheathed FRLS cable of specified size of multistranded copper conductor 1100 volts grade IS:694 marked and one run of 2.5 sqmm PVC insulated but unsheathed FRLS cable for earth continuty conductordrawn through and under suitable size of rigid non metallic PVC conduit , medium grade, ISI marked ( not less than 20 mm dia) complete with all acessories and fittings all laid/fixed concealed in wall/ceiling or surface in wall and surface conduit on ceiling, and also include the specified runs of specified size earth continuity conductor of similar type cable complete all as specified - 3 Runs of 2.5 Sqmm single core cable and one PVC conduit shall be measured as one unit length all as specified and directed by engineer-in-charge.
Supply and fixing MCB distribution board with Bus bar 200A neutral link , earth bar made out of CRCA mild steel sheet surface mounting SPN 4 way 230 volts double door type regal gray horizontal type complete all as specified and as directed by Engineer-in-Charge. Note :- MCB shall be measured and paid seperately.
Supply and fixing MCB distribution board with Bus bar 200A neutral link , earth bar made out of CRCA mild steel sheet surface mounting SPN 8 way 230 volts double door type regal gray horizontal type complete all as specified and as directed by Engineer-in-Charge. Note :- MCB shall be measured and paid seperately.
S&F MCB SP 5 to 32 Amps 10 KA, 240 volt 'C' Series all as specified and directed by engineer-in-charge.
S&F MCB SPN 40 Amps 10 KA, 240 volt 50 Hz 'C' Series all as specified and directed by engineer-in-charge.
shakti construction
stage.html
html • 0.04 MB
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .