Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹54.8 LAccepted-AOC | L1 | Accepted-AOC Accepted | |
| 2 | L2₹61.5 L+₹4.7 L (8.36%)Rejected-Finance | L2 | Rejected-Finance Not L1 | |
| 3 | L3₹62.0 L+₹5.3 L (9.30%)Rejected-Finance NO 98 1 1C YOJANANAGAR LOHEGAON WAGOLI ROAD NEAR SIVBHA DARBAR HOTEL LOHEGAON PUNE 411047 | PUNE | PUNE | MAHARASHTRA | 411047 | L3 | Rejected-Finance Not L1 | |
| 4 | L4₹63.2 L+₹6.5 L (11.4%)Rejected-Finance | L4 | Rejected-Finance Not L1 | |
| 5 | L5₹63.7 L+₹7.0 L (12.3%)Rejected-Finance | L5 | Rejected-Finance Not L1 |
Tender Value
₹63.0 L
EMD Value
₹1.2 L
Closing Date
18 Jan 2022, 6:00 pmClosed
CWE (ARMY) SECUNDERABAD
CWE (ARMY) MUDFORT COMPLEX, SECUNDERABAD- 500003
SPECIAL REPAIRS TO BLDG NO T-33 AND T-34 (OTM BLDG) OF EME RECORDS UNDER GE (SOUTH) SECUNDERABAD
2021_MES_495622_1
CWE(S)/SOUTH/TOKEN-27 OF 2021-2022
Open Tender
Civil Works
Item Rate
270 days
Secunderabad
As per NIT
7 documents required · 7 mandatory
₹1,000
GE South Secunderabad
₹1.2 L
Yes
3 Mar 2022
17 Dec 2021
25 Jan 2022
17 Dec 2021
18 Jan 2022
12 Jan 2022
Amount
Dismantling of single layer mangalore pattern or similar tiles roofing including ridges complete all as specified and as directed.
Dismantling the battens of any size for tiles including tiling fillets spaced exc 15cm c/c complete all as specified and as directed.
Dismantling timber scantling 40 sq cm and over in any position complete all as specified and as directed.
S&F for mild steel sections as in main and cross beams hip and jack rafters, purlines fixed independently all as specified complete all as specified and directed.
M&L Pre painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall, fixed with self tapping screws complete all as specified and directed.
S&F Pre- painted galvalume aluminum zinc coating AZ-150 GI based plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in ridges, fixed with self tapping screws complete all as specified and directed.
Demolition of brick work or stone masonary built in cement mortar complete all as specified and as directed.
M&L for Brick work with sub-class `B' bricks, straight or curved on plan exceeding 6 M mean radius built in cement mortar 1:6 complete all as specified and as directed.
M&L for brickwork with subclass ‘B’ bricks straight or curved on plan to any radius in half brick thickwalls built in CM 1:4 all as specified and as directed
M&L for plain cement concrete type B1 1:2:4 (using 20 mm gradded aggregate), in coping, complete all as specified and directed.
Taking down cement plaster on brick or stone walls built in cement mortar including raking out joints, hacking for key, scrubbing down with water etc complete all as directed.
M&L rendering 15mm thick in CM 1:6 on brick or stone surface finished even and smooth without using extra cement complete all as specified and directed.
Material and labour for rendering 5mm thick in cement mortar (1:4) with WPC over a layer of 10 mm thick in CM 1:6 on fair faces of brickwork or concrete surfaces, finished the surface even and fair complete all as specified and directed.
Supply only integral water proofing compound for roof and sunken floor complete all as specified and directed.
M&L preparation of new steel surfaces and applying two coats of synthetic enamel paint over a coat of redoxide primer complete all as specified and directed.
M&L for appling two coats of OBD over a coat of primer and 3mm thick wall care putty after preparation of new surfaces on walls incl finished the surface even and smooth complete all as specified and directed.
M&L for complete removal or existing wall treatment and applying two coats of OBD over a coat of primer including 3mm thick wall care putty finished the surface even and smooth including preparation complete all as specified and directed.
M&L for complete removal of existing treatment including washing/ scrubbing down and applying two coats of cement base paint over a coat of primer on external walls, all as specified and directed.
M&L applying two coats of cement based paint over of a coat of primer including preparation of new plastered surfaces of wall all as specified and directed.
Taking down chowkats or frames with shutters (without taking off shutter from the frames ) not exceeding 1.5 Sqm each complete all as specified and as directed.
Taking down chowkats or frames with shutters (without taking off shutter from the frames ) exceeding 1.5 Sqm each but n.exc. 4 sqm each complete all as specified and as directed.
Taking down door shutters of any description area exc 1.00 sqm and not exc 2.00 sqm each complete all as specified and directed
M&L for Cutting holes in brick wall built in cement mortar depth of embedded portion of hold fast exc half brick but not exc one brick and making good dismantled portion in cement mortar (1:3) or plain cement concrete (1:2:4) type B1 complete all as specified and as directed.
M&L PCC 1:3:6 type C-1 (using 20mm size graded stone aggregates ) as in bed blocks etc incl necessary form work incl weathering, slightly rounded or chamfered angles and throating all as directed.
S&F of Pressed steel frames for doors of size 105x60mm with one or more rebates including necessary fixing lugs, hinges, lock strike plate etc complete as specified and directed.
S&F of Pressed steel frames for doors of size 125x60mm with one or more rebates including necessary fixing lugs, hinges, lock strike plate etc complete as specified and directed.
M&L for PCC 1:3:6 type C0 (using 12.50mm size gradded stone aggregate)as in filling of doors frames complete all as specified and directed.
M&L for Mild steel frame work such as grills framed guard bars confirming to Fe.290.Gde-E-165 complete all as specified and directed.
S & F 2 nd class hard wood 35mm thick factory made plain framed, panelled shutter (two panels) with lock rail and pannel of 12mm veneered particle board with comercial vencering on both faces The size of rail and stile as per IS -1003 (part-I) Kiln seasond and chemically pressure treated complete all as specified and directed
S & F, steel windows double shutter (one side glazed type and other side gauzed type) with pressed steel frame and side hung shutters including projecting or box type hinges with steel handle & steel peg stay, complete with glazing bars, dovetailed or welded complete all as specified and as directed.
S&F 2nd class hardwood 35mm thick Glazed and skeleton shutters open rebated and prepared to receive glass , gauge etc., (without sash bars) edges og framing plain, chamfered or roundered , fitted with cutand mitred beadsforsecuring glass, etc sizes of members of shutters as specified in SSR Pt-I, section 8 , clause 8.24 (a) fitted to chowkat complete all as specified and directed.
S&F of 150 mm size extruded aluminium alloy handles, fabricated type, anodised complete all as specified and directed.
S&F 200 mm long aluminium anodised barrel tower bolt of extruded section and fixed complete all as specified and directed.
S&F aluminium alloy anodised sliding door bolt with hasp staple (bolt type) length 300mm
S&F for Stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperature 1.40mm and fixed with stainless steel wire staples complete all as specified and directed.
S&F Repairs Stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperature 1.40mm and fixed with stainless steel wire staples complete all as specified and directed.
S&F 3mm thick sheet glass ordinary quality and glazing with oil putty in square panels or with wooden bead n.exc 0.50 Sqm each pane complete all as specified and directed..
M&L for one coat of synthetic enamel paint including preparation of old painted wooden surfaces of any description over 10 cm width and girth complete all as specified and directed.
M&L Preparing new wooden surfaces of any description over 10 cm width or girth and applying two coats of synthetic enamel paint over one coat of pink primer complete all as specified and directed.
Dismantaling stone slabs and tiles of any description or thickness in floor ,aprons laid bedded and pointed in any mortar complete all as specified and as directed.
Demolition of cement concrete in ground floor and paving n exc 15 cm thickness below and above ground level all as directed.
M&L 75 mm thick plain cement concrete 1:3:6 type C-2 using 40 mm graded stone aggregate, laid in alternate bays in panels not exe. 2.00 Sqm area each with 6mm wide joints filled with mastic filling, finished even & smooth as in plinth protection, complete all as specified and as directed.
M&L for 75 mm thick PCC 1:4:8, type D2 by using 40 mm graded aggregate as in sub base of floor complete all as specified and as directed.
M&L Machine cut kota stone slab flooring 20-25mm thick laid over 20 mm thick screed bed in CM 1:6 laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete all as specified and directed.
M&L Machine cut kota stone slab 20-25mm thick laid over 15mm thick rendering in CM 1:4 backing of tiles as in skirting/ dados etc including rubbing and polishing complete all as specified and directed.
M&L Chequered cement concrete tiles 30cm x 30cm x 25 mm thick set, jointed with white cement & pigment and pointed in colour / white cement to match the shade of tile laid over 20 mm thick screed bed in CM 1:6 complete all as specified and directed.
Taking down existing unserviceable point wiring of any description/type/ size of light/fan/power/two way/bell etc on TW batten/conduit including removal of batten / conduit / gutties / wooden boards / switches / sockets / regulators/ light fittings etc and removal of unserviceable material out of site area and making good the disturbed surfaces of wall/ceiling so as to match with the existing finishes all as specified & directed
Taking down the existing unserviceable main switch / cut out / DBs of any type / capacity / description as per existing at site including making good the disturbed surfaces to match with the existing finishes all as specified and directed.
M & L for Point wiring in Concealed/surface conduit in wall with 1.5 Sq mm copper conductor single core PVC insulated cable FRLS type 1100 V grade multistranded drawn through conduit and including rigid PVC conduit and conduit accessories of suitable dia medium grade and pressed steel terminal boxes of 1.6 mm thick MS, duly painted with red oxide metal primer including fixing/grouting sunken/ surface as per site requirement covered with 3 mm thick laminated sheet including running up of 1.5 Sq mm copper conductor PVC insulated cable as earth continuity conductor along with wiring and connecting to the common earth dolly for fixing the switches/ sockets/ regulators etc all as specified for :
(a) One light point controlled by one, one way switch 5A, SP
(b) One ceiling / exhaust fan point controlled by one, one way switch and regulator
(c) One 2/3 pin 5 Amps socket outlet point controlled by one switch on the same board
(d) One 3 Pin 5 Amps switch socket Independt board
All as per Item No 49.00 here-in-before but using 4 Sq mm single core copper conductor cable multistranded PVC insulated FRLS 1100 Volts grade for 6/16 Amps switch socket combination point including running of 4.00 Sq mm copper conductor PVC wire as earth continuity conductor along with wiring and connecting to the common earth dully.
S & F Switch piano type single pole one way flush type 5 Amps capacity 230 volts complete all as specified and directed.
Supply and fix switch socket combination flush type multipurpose 2/3 pin 5 Amps, 230 Volts complete all as specified and directed.
Supply and fix socket outlet flush type multipurpose 2/3 pin 5 amps, 230 volts complete all as specified and directed.
Supply and fix switch socket combination flush type multipurpose 5 in 1, 5/16 Amps, 230 Volts complete all as specified and directed.
S & F ceiling rose three terminal surface bakelite type AC 50 Hz 230 Volts of size 65 x 50 mm complete all as specified and directed.
S & F angle/batten lamp holder of insulated body with back plate for angle/batten fittings fixed with wooden round blocks complete all as specified and directed.
Supply Fix LED bulb of 9W complete all as specified and directed
Supply and fix box type Wall mounted light fittings with LED lamp 18/20/22 W complete all as specified and directed
S&F electronic type regulator two module stepped heavy duty for ceiling fan suitable to work on 230 volts complete all as specified and directed
S & F Security Lights of 1x25 watt LED light with high power LED and unique peanut lens to ensure uniform distribution and including provision of 1.5 sqmm 3 core multistranded copper conductor cable from light fitting to junction box complete all as specified and directed .
M & L bracket made out of GI pipe of suitable dia for srl item No. 59, not less than 1.2 mtr long and fixed on walls with 2 nos MS clamps made out of MS flat of suitable size thickness complete with MS nuts, bolts and washers etc bent to required shape complete all as specified and directed
S & F Vertical type TPN DB 8 way double door with incoming as MCCB TP 415 volts AC 3 phase 50 Hz with fixed magnetic setting for current rating of 100 Amps 16 KA with locking arrangement complete all as specified and directed
S & F Sheet metal enclusure MCB DB SPN 8 way double door with 200A rated bus bar 240V double door with flush type locking system complete all as specified and directed.
S & F Sheet metal enclosure MCB DB SPN 4 way double door with 200A rated bus bar 240V double door with flush type locking system complete all as specified and directed.
S & F MCB SPN 63 Amps 240 volts for fixing on MCB DB's complete all as specified and directed.
S & F MCB SP 6 to 32 Amps 240 volts for fixing in MCB DB's complete all as specified and directed.
M & L for Submain wiring with two single core 6 Sq mm PVC insulated cable FRLS type copper conductor multistranded 1100 Volts grade drawn through and including rigid PVC conduit and conduit accessories of 25 mm dia medium grade including running up of 6 Sq mm copper conductor multistranded PVC insulated cable as earth continuity conductor along the wiring and connected to the common earth dolly complete including removing the existing unserviceable sub main wiring and making good the disturbed surface to match with the existing all as specified. Note:-two runs of cable, one run of earth contuinity conductor and one run of conduit shall be measured and paid as one unit length.
M & L for Submain wiring with two single core 10 Sq mm PVC insulated cable FRLS type copper conductor multistranded 1100 Volts grade drawn through and including rigid PVC conduit and conduit accessories of 25 mm dia medium grade including running up of 10 Sq mm copper conductor multistranded PVC insulated cable as earth continuity conductor along the wiring and connected to the common earth dolly complete including removing the existing unserviceable sub main wiring and making good the disturbed surface to match with the existing all as specified. Note:-two runs of cable, one run of earth contuinity conductor and one run of conduit shall be measured and paid as one unit length.
Earthing complete with galvanised steel earth plate electrode 60cm x 60cm x 6mm thick burried directly in ground to a depth not less than 2.25 m below ground level with top edge of earth plate not less than 1.5 m below normal ground level connected to GI earth lead wire 4 mm dia by means of bolts, nut, check nuts and washers etc of galvanised iron and earth lead protected by provision of GI pipe 15 mm bore of medium grade from earth electrode to DBs/Main switch all as shown in Electrical Plate No 3 of SSR Part I and connected to main switch board including excavation and earth work in any type of soil, PCC chamber in 1:2:4 Type B-1 using 20 mm graded stone aggregate 75 mm thick RCC cover in 1:2:4 type B-1 reinforced with 6mm dia bars at 75mm c/c both ways with 12mm dia MS bar handle made to shape, 20 mm dia medium grade GI watering pipe perforated at bottom 1.75m long with funnel and wire mesh, common salt and charcoal filling complete including testing on completion all as specified Note: GI pipe 15mm dia & GI earth lead 4mm dia upto 7.5 m length is deemed to be included in quoted rate
Disconnecting and removing ceiling fan of 1200/1400 mm sweep from any height bringing down, dismantling, cleaning internally and externally, thoroughly examine, replacement of split pins, cotter pins and check nuts etc overhauling, lubricating with approved lubricants, reassembling, including replacement of wornout/defective parts, refixing in original position including minor repairs for the smooth functioning and provision of new flexible wire of size 23/0.0076 multistranded copper conductor cable from ceiling rose to fan. NOTE :- (1) Necessary repairs/ replacement of unserviceable parts shall be measured and paid seperately.(2) Labour element for replacing of u/s parts deemed to be included in rate quoted.
M & L rewinding of burnt ceiling fan motor of 1200 / 1400mm sweep with supper enameled copper wire of suitable size of any make, type, model incl transportation complete all as specified and directed
Supply only Capacitor 2.5 Mfd capacity 240 Volts.
Supply only Sealed ball bearing
Supply only Rubber bushes
Supply and replace downrod of 4ft height.
Sri Associates
S.R.M.K Enterprises
BEEGEE DESIGN SYSTEMS
Saiansh Associates
c devender reddy and co
M/S DIVIJA BUILDERS
STANDARD AGENCIES
Bidder Name
Saiansh Associates
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .