| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹18.8 LAccepted-AOC 11TH FLOOR ECO CENTRE BUSINESS TOWER P NO 4 EM BLOCK SECTOR V KOLKATA 91 | KOLKATA | 24 PARAGANAS NORTH | WEST BENGAL | 700091 | ₹18.8 L | L1 | Accepted-AOC L1 |
| 2 | L2₹20.1 LRejected-Finance 4TH FLOOR VOLTAS HOUSE A BLOCK DR BABASAHEB AMBEDKAR ROAD CHINCHPOKLI MUMBAI MAHARASHTRA 400033 | MUMBAI | MAHARASHTRA | 400033 | ₹20.1 L | L2 | Rejected-Finance L2 |
| 3 | L3₹23.0 LRejected-Finance 306 BAKSHI HOUSE NEHRU PLACE SOUTH DELHI DELHI 110019 INDIA | SOUTH | DELHI | 110019 | ₹23.0 L | L3 | Rejected-Finance L3 |
| 4 | L4₹23.2 LRejected-Finance | ₹23.2 L | L4 | Rejected-Finance L4 |
| Sl No | Description | Qty | Unit | VOLTAS LIMITED L2 | M/s Cooltec L4 | VOLKS ENERGIE PVT LTD L3 | Bluestar Limited L1 |
|---|---|---|---|---|---|---|---|
| 1.00 | Dismantling of existing Ceiling suspended chilled water cooled type FCU from the existing false ceiling including dismantling of insulation and pipelines including other associated accessories, shifting of old FCUs along with accessories and handing over to AAI designated stores etc. complete as required. | 28 | Job | 3,050 ₹85,400 | 6,000 ₹1.7 L | 3,000 ₹84,000 | 3,250 ₹91,000 |
| 2.00 | Supply of 2 TR Ceiling suspended chilled water fan coil units complete alongwith all associated accessories such as casing, filter cabinet with synthetic fibre filters, 3 row deep copper cooling coil, double inlet forward curve twin blower, single fan motor with 3 - variable speed suitable for operation of single phase 230 Volt, 50 HZ, AC power supply, wired thermostats with provision of Manual / remote control operation, 2 way modulating control solenoid valve with actuator, providing and fixing of suitable length and size heavy duty PVC drain pipe including interconnection with existing drain pipe line, suitable size copper pipe for interconnection between FCU & Chilled water line, providing required quantity of power / control cables including connection, testing and commissioning etc., complete alongwith following accessories as per technical specifications / scope of work as required.
a) Copper flexible connection of suitable size complete with set of ball valves and strainers shall be provided.
b) Providing & fixing of double layered fire proof canvass complete with flange type suitable for inter connection with duct collar and fan coil unit.
c) FCU shall be provided with additional SS Drain tray of suitable size under the FCU with suitable supporting arrangement. | 28 | Each | 53,630 ₹15.0 L | 52,000 ₹14.6 L | 69,143 ₹19.4 L | 50,846 ₹14.2 L |
| 3.00 | Installation, testing and commissioning of 2 TR ceiling mounted chilled water type fan coil unit in the existing false ceiling using suitable supports, fastners, downrods etc. including all necessary modifications to existing pipelines if any by cutting / welding/ interconnection including provision of new thermal insulation with nitrile rubber, gasket of suitable materials and thickness to be pasted with adhesive etc. Supply and Provision of ducting system made up of suitable thickness GI materials for interconnection of unit & grills including XLPE thermal insulation of suitable thickness (both upto 2.5 sqmtr), providing & fixing of new supply air grill (Max 1 Sqm) alongwith VCD control, termination of all associated electrical power /control cable i/c testing and commissioning etc. as required. | 28 | Jobs | 15,280 ₹4.3 L | 25,000 ₹7 L | 10,000 ₹2.8 L | 13,000 ₹3.6 L |
Tender Value
₹27.0 L
EMD Value
₹81,088
Closing Date
15 Sept 2025, 5:00 pmClosed
SM(E-E)
AAI, Admin building operational office, Chennai Airport.
Improvement of Airconditioning system at IT equipment rooms of T1 and T4 Terminal building at CIA
2025_AAI_246253_1
AAI/CHN/E-E/HVAC/IT-FCU/25
Open Tender
Electrical Works
90 days
Chennai
As per NIT
19 documents required · 19 mandatory
₹1,180
₹81,088
26 May 2026
26 Aug 2025
16 Sept 2025
26 Aug 2025
15 Sept 2025
26 Aug 2025
26 Aug 2025 - 1 Sept 2025
Amount
Dismantling of existing Ceiling suspended chilled water cooled type FCU from the existing false ceiling including dismantling of insulation and pipelines including other associated accessories, shifting of old FCUs along with accessories and handing over to AAI designated stores etc. complete as required.
Supply of 2 TR Ceiling suspended chilled water fan coil units complete alongwith all associated accessories such as casing, filter cabinet with synthetic fibre filters, 3 row deep copper cooling coil, double inlet forward curve twin blower, single fan motor with 3 - variable speed suitable for operation of single phase 230 Volt, 50 HZ, AC power supply, wired thermostats with provision of Manual / remote control operation, 2 way modulating control solenoid valve with actuator, providing and fixing of suitable length and size heavy duty PVC drain pipe including interconnection with existing drain pipe line, suitable size copper pipe for interconnection between FCU & Chilled water line, providing required quantity of power / control cables including connection, testing and commissioning etc., complete alongwith following accessories as per technical specifications / scope of work as required. a) Copper flexible connection of suitable size complete with set of ball valves and strainers shall be provided. b) Providing & fixing of double layered fire proof canvass complete with flange type suitable for inter connection with duct collar and fan coil unit. c) FCU shall be provided with additional SS Drain tray of suitable size under the FCU with suitable supporting arrangement.
Installation, testing and commissioning of 2 TR ceiling mounted chilled water type fan coil unit in the existing false ceiling using suitable supports, fastners, downrods etc. including all necessary modifications to existing pipelines if any by cutting / welding/ interconnection including provision of new thermal insulation with nitrile rubber, gasket of suitable materials and thickness to be pasted with adhesive etc. Supply and Provision of ducting system made up of suitable thickness GI materials for interconnection of unit & grills including XLPE thermal insulation of suitable thickness (both upto 2.5 sqmtr), providing & fixing of new supply air grill (Max 1 Sqm) alongwith VCD control, termination of all associated electrical power /control cable i/c testing and commissioning etc. as required.
VOLTAS LIMITED (BID ID -899710)
VOLKS ENERGIE PVT LTD (BID ID -900084)
M/s Cooltec (BID ID -899909)