Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.5 CrAccepted-AOC CAMP INS CHILKA CHHATRAGARH PO NB CHILKA ODISHA 752 037 | KHORDHA | ODISHA | 752037 | ₹1.5 Cr | L1 | Accepted-AOC being the lowest tenderer |
| 2 | L2₹1.6 Cr+₹6.8 L (4.38%)Rejected-Finance | ₹1.6 Cr+₹6.8 L (4.38%) | L2 | Rejected-Finance not lowest |
| 3 | L3₹1.7 Cr+₹19.1 L (12.4%)Rejected-Finance | ₹1.7 Cr+₹19.1 L (12.4%) | L3 | Rejected-Finance not lowest |
| 4 | L4₹1.9 Cr+₹34.3 L (22.2%)Rejected-Finance | ₹1.9 Cr+₹34.3 L (22.2%) | L4 | Rejected-Finance not lowest |
| 5 | L5₹2.0 Cr+₹44.6 L (28.9%)Rejected-Finance | ₹2.0 Cr+₹44.6 L (28.9%) | L5 | Rejected-Finance not lowest |
Tender Value
₹1.3 Cr
EMD Value
₹2.0 L
Closing Date
20 Dec 2023, 6:00 pmClosed
CWE NO.2 VISAKHAPATNAM
CWE NO.2 VISAKHAPATNAM, HQ CE (N) COMPLEX, RAILWAY STATION ROAD, VISAKHAPATNAM - 530004
PROVISION OF WATCH TOWER FOR AUGMENTATION OF SECURITY INFRASTRUCTURE AT INS CHILKA, ODISHA
2023_MES_609579_4
82620
Open Tender
Civil Works
Lump-sum
270 days
GARRISON ENGINEER CHILKA
AS PER TENDER DOCUMENTS
7 documents required · 7 mandatory
₹1,000
GARRISON ENGINEER CHILKA
₹2.0 L
Yes
2 Apr 2024
29 Nov 2023
22 Dec 2023
29 Nov 2023
20 Dec 2023
29 Nov 2023
Amount
Schedule "A" Part – I to IX: NOTE: Schedule "A" Part – I to Part – IX are prepriced by MES.
Lumpsum price worked out by the contractor for "BUILDING WORKS", as listed in Schedule "A" Part – I (Refer pre priced schedule attached seperately).
Lumpsum price worked out by the contractor for "EARTHWORK & EXCAVATION", as listed in Schedule "A" Part – II (Refer pre priced schedule attached seperately).
Lumpsum price worked out by the contractor for "INTERNAL ELECTRIFICATION", as listed in Schedule "A" Part – III (Refer pre priced schedule attached seperately).
Lumpsum price worked out by the contractor for "INTERNAL WATER SUPPLY", as listed in Schedule "A" Part – IV (Refer pre priced schedule attached seperately).
Lumpsum price worked out by the contractor for "AREA DRAINAGE" as listed in Schedule "A" Part – V (Refer pre priced schedule attached seperately).
Lumpsum price worked out by the contractor for "SEWAGE DISPOSAL", as listed in Schedule "A" Part – VI (Refer pre priced schedule attached seperately).
Lumpsum price worked out by the contractor for “ROAD / PATH / HARDSTANDING” as listed in Schedule ‘A’ Part -VII (Refer pre priced schedule attached seperately).
Lumpsum price worked out by the contractor for “EXTERNAL WATER SUPPLY” as listed in Schedule ‘A’ Part - VIII (Refer pre priced schedule attached seperately).
Lumpsum price worked out by the contractor for "EXTERNAL ELECTRIC SUPPLY", as listed in Schedule "A" Part – IX (Refer pre priced schedule attached seperately).
Schedule "A" Part - X: Miscellaneous Items for B/R and E/M Works Note : This schedule is not pre-priced by MES and the pre-priced rate indicated as "Rs 0.00" under Col. 5 siginifies this fact only.
M&L point wiring with 1.5 sqmm PVC insulated unsheathed multistranded copper cable of FRLS grade with one run of 1.5 sqmm PVC insulated copper cable as earth continuity drawn in and including concealed PVC conduit not less than 20 mm dia with pressed steel in concealed MS box duly and including covered with 3 mm thick hylam sheet for mounting switches / Sockets, accessories such as spacers, saddles, junction boxes complete all as specified and directed for the following :- Note- The quoted rate is deemed to be include cutting, chasing, pinning and making good the disturbed surface.
One light / fan / exhaust / bell point controlled by one switch
One 3 pin 5 Amps socket out let on Independent board.
All as per Sl. item No. 12 above but with 2.5 sqmm cable with one run of 2.5 sqmm cable as earth continuity on independent board.
S&F MCB 6 to 32 Amp, 240 Volt, SP breaking capacity 10 KA 'C' series complete all as specified and directed.
S&F 1 x 20 w tubelight fitting with lamp, Endura linear LED Wall mounted LED batten with polycarbonate housing & intergated driver for efficient heat dissipation with fitting complete all as specified and directed.
S&F 1 x 9 / 10 watt indoor batten type luminaries decorative ultra slim linear LED lighting fixture with extruded polycarbonate and including LED tube of capacity 9 / 10 watt with decorative holder and end cap and connecting up with three / two core twisted flexible copper conductor cable with suitable size complete all as specified and directed.
S&F LED street light 25 W, made up of pressure die cast aluminium housing with high power LED as lighting source and lens embeded PC cover having top opening separate driver compartment with IP 66 protection and impact resistance of IK07 and including necessary fixing arrangement suitable length and dia GI pipe, clamp etc, complete all as specified and directed.
M&L cutting or screwing existing GI pipe of any insertion of suitable for branch connection dia complete all as specified and directed.
Supply and lay well burnt / fly ash brick of size 200 x 100 x 80 mm locally available as protection of cable in trenches complete all as specified and directed.
M&L cutting the existing road / PCC / drain for laying of undergound cable and including necessary earth work and making good to match with the existing surface with PCC 1:2:4 type B1 using 20 mm graded aggregate complete all as specified and directed.
S&F 15mm chromium plated, 2 way bib cock double handle with flange complete all as specified and directed.
M/S JAGANNATH SASMAL
DHABALESWAR ENGINEERING WORKS
M/S SIWALIK AND CO
R K Traders
stage.html
html • 0.05 MB
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .