Loading…
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹24.8 LAdmitted-Finance | L1 | Admitted-Finance | |
| 2 | L2₹24.9 L+₹2,985.40 (0.12%)Admitted-Finance 2 MORE SARAI CH CHOWK DELHI CENTRAL DELHI DELHI 110006 | NORTH DELHI | DELHI | 110006 | L2 | Admitted-Finance | |
| 3 | L3₹24.9 L+₹11,292.60 (0.45%)Admitted-Finance CW 545 SANJAY GANDHI TRANSPORT NAGAR NEW DELHI 110042 | NORTH | DELHI | 110042 | L3 | Admitted-Finance | |
| 4 | L4₹30.7 L+₹5.8 L (23.5%)Admitted-Finance PP 32 MAURYA ENCLAVE PITAMPURA CHAITANYA CONSTRUCTION CO PP 32 MAURYA ENCLAVE PITAMPURA DELHI NORTH WEST DELHI DELHI 110034 | NORTH WEST DELHI | DELHI | 110034 | L4 | Admitted-Finance | |
| 5 | Not Admitted-Fee/PreQual/Technical SHOP NO 55 GROUND FLOOR ROHINI SECTOR 7 NAHARPUR FLOOR HARLAL MARKET NAHARPUR SECTOR 7 DELHI OPP GOYAL GARMENTS VILLAGE TOWN DELHI CITY DELHI | - | Not Admitted-Fee/PreQual/Technical Others-EMD/FDR Not Submitted |
| Sl No | Description | Qty | Unit | Devraj Enterprises L3 | CHANDERA BUILDERS L2 | Raj Engineering Co. L1 | M/S CHAITANYA CONSTRUCTION CO. L4 |
|---|---|---|---|---|---|---|---|
| 1.00 | Supply of Horizontal Split casing single stage pump having flanged suction & delivery and suitable to handle potable water. The pump should have following duties:-
Discharge Capacity :- 115 -130 m3/hr
Duty Head :- 40 Mtrs.
Speed :- 1450 RPM
Material of Construction
Casing : CI
Shaft : Stainless Steel EN-8
Impeller : CI
Sleeve : SS-410
Wear ring : CI Make: Mather & Plate / Kirloskar/Jyoti/Beacon weir/DJB approved | 2 | Nos. | 2,82,600 ₹3,33,468 | 1,98,000 ₹2,33,640 Lowest | 2,80,000 ₹3,30,400 | 2,65,000 ₹3,12,700 |
| 2.00 | Supply of 30 HP 1500 RPM (Syn) squirrel cage induction motor suitable to operate on 400±10% Volt, 3Ph , 50Hz , Horizontal foot mounted confirming to IEC:60034-1. SOR(E&M)-2024 Item Code 3.2.18. Make:- ABB/Kirloskar/Jyoti/Crompton/DJB approved | 2 | Nos. | 2,73,140 ₹3,22,305.2 | 2,02,000 ₹2,38,360 Lowest | 2,73,000 ₹3,22,140 | 2,65,000 ₹3,12,700 |
| 3.00 | Supply of MS Base frame, flexible Tyre coupling, coupling guard suitable for above pump sets. | 2 | Sets | 30,400 ₹35,872 | 44,000 ₹51,920 | 29,980 ₹35,376.4 Lowest | 65,000 ₹76,700 |
| 4.00 | Providing & fixing LT Starter Panel Board of size 1400x1200x350 mm made out of 14 SWG CRCA sheet floor mounted type and suitable to fix below mentioned items, i/c provision for cable entry & base frame made out of MS channel. The panel should be duly painted with vermin proof paint and completely wired with suitable size copper wire.
Incomer consisting of following:- 1 no. automatic Phase Sequence Correcting Power Switch Circuit with a provision for manual operation : 250 Amps 4P, 415 VAC 50 Hz Make:-L&T/ABB/Schneider/Siemens/Socomec/HP ,1 no. MCCB TP 250 Amps 36 kA Thermal Magnetic with adjustable Trip Setting for Overload and Short Circuit Protection Make:-Siemens/L&T/ABB/Schneider , 1 No. voltmeter with VSS 0-500 VAC Digital Type 96mm X 96mm Make:- Rishabh/AE/L&T/Schneider , 1 No. ammeter with ASS 0 - 250 Amps Digital type 96mm X 96mm Make:- Rishabh/AE/L&T/Schneider , 1 No. energy Meter (KwHr) Digital Type CT operated Class 0.5 Make:- Rishabh/AE/L&T/Schneider , 3 Nos. CT 250 / 5 Amps Class : 0.5 for metering Make:- Kappa / AE , 1 No. CT 250 / 5 Amps for Power Factor Control Make:- Kappa / AE , 3 Set R Y B Indication Make:- Teknic / L&T / ABB / Schneider , 3 Set On / Off / Trip Indication Make:-Teknic / L&T / ABB / Schneider , 1 No. CBCT based Earth Fault Protection System to trip the MCCB in case of Earth Fault, Make:- Prok Devices / Elmeasure / Siemens / Schneider / ABB / L&T , 1. No Earth Fault Trip Indication suitable for operation of 2P/set Make:- Teknic / L&T / ABB / Schneider.
Control consisting of following:-
1 No. Current Transformer 415 VAC / 220 VAC 500 VA Make:- Logicstat / Eq ,2 Nos. Control MCB DP 10 Amps Make:- Siemens/L&T/ABB/Schneider , 1 No. Control On Indication Make:-Teknic / L&T / ABB / Schneider.
Starter Section consisting of following:-
30 HP Star / Delta Starter (1W + 1S) with following total material for both
2 Nos. MCCB TP 36 kA Motor Duty Suitable for 30 HP Make:-Siemens/L&T/ABB/Schneider, 4 Nos. Contactor TP 95 Amps AC3 Duty 220 VAC Make:- Siemens/L&T/ABB/Schneider , 2 Nos. Contactor TP 63 Amps AC3 Duty 220 VAC Make:- Siemens/L&T/ABB/Schneider, 2 Nos. Thermal Over Load Relay 45-63 Amps Make:- Siemens/L&T/ABB/Schneider , 2 Nos. Single Phase / Phase Reversal Protection Make:- Minilec / L&T / E1 , 4 Set Start / Stop PB Make:- Teknic / L&T / ABB / Schneider , 4 Set On / Off / Trip Indication Make:- Teknic / L&T / ABB / Schneider , 4 Nos. Star / Delta Timer Make:- Siemens/L&T/ABB/Schneider.
DOL Starter up to 5 H.P for 2 nos. P/set. having 2 No. MCB TP 16 Amps Make:- Siemens/L&T/ABB/Schneider , 1 No. Contactor 16 Amps TP 230 VAC Make:- Siemens/L&T/ABB/Schneider , 1 No. Overload Relay 2.8 - 4 Amps Make:- Siemens/L&T/ABB/Schneider , 1 No. Single Phase / Phase Reversal Protection Make:- Minilec / L&T / E1 , 2 Set Start / Stop PB Make:- Siemens/L&T/ABB/Schneider , 2 Set On / Off / Trip Indication Make:- Teknic / L&T / ABB / Schneider.
Lighting Section having 4 Nos. 10 Amps SP MCB for lights/Fans etcMake:-Siemens/L&T/ABB/Schneider.
Power Factor Section of 50 KVAR APFC System having
1 No. MCCB TP 160 Amps Thermal Magnetic 36 kA for APFC section isolation Make:- Siemens/L&T/ABB/Schneider , 1 No. Microprocessor based APFC Relay 6 Steps Make:- Epcos / L&T / ABB / Beluk , 4 Nos. Capacitor Heavy Duty MPP 10 KVAR 415 VAC Make:- Epcos / L&T / ABB / Beluk , 4 Nos. Capacitor Duty Contactor suitable for 20 KVAR or higher 220 VAC Make:- Siemens/L&T/ABB/Schneider , 4 Nos. MCB TP 40 Amps Make:- Siemens/L&T/ABB/Schneider , 4 Nos. Auto / Manual Selector Switch with LED Indication Make:- Teknic / L&T / ABB / Schneider , 8 Set Start / Stop PB in manual mode Make:- Teknic / L&T / ABB / Schneider , 2 Nos. Capacitor Heavy Duty MPP 5 KVAR 415 VAC Make:- Epcos / L&T / ABB / Beluk , 2 Nos. Capacitor Duty Contactor suitable for 10 KVAR or higher 220 VAC Make:- Siemens/L&T/ABB/Schneider , 2 Nos. MCB TP 20 Amps Make:- Siemens/L&T/ABB/Schneider , 2 Nos. Auto / Manual Selector Switch with LED Indication Make:- Teknic / L&T / ABB / Schneider , 4 Set Start / Stop PB in manual mode Make:- Teknic / L&T / ABB / Schneider.
Miscellaneous Material having 1 No. Bus Bar with heak shrinkable sleeves Make:- Hindalco / EC Grade with certificate , 1 No. Powder Coated Panel Enclosure with accessories Make:- DJB Approved , 1 No. Control wire. Make:- DJB Approved , 1 No. Power Wire. Make:- DJB Approved , 1 No. Dismantling of existing panel, 1 No. Delivery and installation of new panel, 1 No. Lugs / Glands as required for connections. | 1 | Job | 4,20,200 ₹4,95,836 Lowest | 4,65,000 ₹5,48,700 | 4,78,800 ₹5,64,984 | 4,88,650 ₹5,76,607 |
| 5.00 | Supply of PVC insulated PVC sheathed armored aluminum conductor power cable 1.1 KV as per IS-1554 ( Part-I) of following sizes.
3½ Core x 120 mm². | 60 | Mtr. | 63,000 ₹74,340 | 39,000 ₹46,020 Lowest | 57,900 ₹68,322 | 57,000 ₹67,260 |
| 6.00 | Supply of PVC Insulated un armored single core Flexible Copper Cable for working voltage upto 1.1 KV as per IS:694/2010 of size 35 mm2.. Make :Grandley / Gloster/DJB approved | 100 | Mtr. | 39,000 ₹46,020 | 24,000 ₹28,320 Lowest | 37,800 ₹44,604 | 25,000 ₹29,500 |
| 7.00 | Supply of CI Sluice Valves non rising with SS spindle ISI PN 1.0 IS 14846 flanged end of following sizes
(a) 200 mm dia. | 2 | Nos. | 1,44,000 ₹1,69,920 | 96,000 ₹1,13,280 Lowest | 1,37,000 ₹1,61,660 | 1,12,000 ₹1,32,160 |
| 8.00 | (b) 150 mm dia. | 2 | Nos. | 80,000 ₹94,400 | 78,000 ₹92,040 Lowest | 79,000 ₹93,220 | 1,32,000 ₹1,55,760 |
| 9.00 | Supply of CI non return valve without bypass swing type IS:5312 flange end of 150 mm dia.
Make:- Kirloskar/IVC/DJB approved | 2 | Nos. | 51,000 ₹60,180 | 78,000 ₹92,040 | 49,980 ₹58,976.4 Lowest | 1,34,000 ₹1,58,120 |
| 10.00 | Pipes &Special
S/o M.S. Pipe of dia.200 mm. | 10 | Mtr. | 36,500 ₹43,070 | 28,000 ₹33,040 | 34,950 ₹41,241 | 26,500 ₹31,270 Lowest |
Tender Value
Refer Docs
EMD Value
₹49,900
Closing Date
3 Jan 2026, 3:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
EXECUTIVE ENGINEER (EM) M-11
GREATER KAILASH, PART-I, NEW DELHI
Supply, installation, Testing and Commissioning of pump set with all E/M equipments for online Booster Pumping Station at Meethapur Chowk Under Badarpur Constituency AC-53.
2025_DJB_283383_12
NIT No. 20/EE(EM)M-11/(25-26)
Open Tender
Electrical Work/ Equipment
Works
60 days
EXECUTIVE ENGINEER (E/M) M-11
Please refer Tender documents.
3 documents required · 3 mandatory
₹500
Delhi Jal Board
₹49,900
Yes
9 Mar 2026
23 Dec 2025
3 Jan 2026
23 Dec 2025
3 Jan 2026
23 Dec 2025
Supply of Horizontal Split casing single stage pump having flanged suction & delivery and suitable to handle potable water. The pump should have following duties:- Discharge Capacity :- 115 -130 m3/hr Duty Head :- 40 Mtrs. Speed :- 1450 RPM Material of Construction Casing : CI Shaft : Stainless Steel EN-8 Impeller : CI Sleeve : SS-410 Wear ring : CI Make: Mather & Plate / Kirloskar/Jyoti/Beacon weir/DJB approved
Supply of 30 HP 1500 RPM (Syn) squirrel cage induction motor suitable to operate on 400±10% Volt, 3Ph , 50Hz , Horizontal foot mounted confirming to IEC:60034-1. SOR(E&M)-2024 Item Code 3.2.18. Make:- ABB/Kirloskar/Jyoti/Crompton/DJB approved
Supply of MS Base frame, flexible Tyre coupling, coupling guard suitable for above pump sets.
Supply of PVC insulated PVC sheathed armored aluminum conductor power cable 1.1 KV as per IS-1554 ( Part-I) of following sizes. 3½ Core x 120 mm².
Supply of PVC Insulated un armored single core Flexible Copper Cable for working voltage upto 1.1 KV as per IS:694/2010 of size 35 mm2.. Make :Grandley / Gloster/DJB approved
Supply of CI Sluice Valves non rising with SS spindle ISI PN 1.0 IS 14846 flanged end of following sizes (a) 200 mm dia.
(b) 150 mm dia.
Supply of CI non return valve without bypass swing type IS:5312 flange end of 150 mm dia. Make:- Kirloskar/IVC/DJB approved
Pipes &Special S/o M.S. Pipe of dia.200 mm.
S/o M.S flange of dia. 200 mm.
S/o M.S. D.F.90° Bend of 200 mm dia.
S/o M.S. D.F.90° Bend of 150 mm dia.
S/o M.S. Pipe of 150 mm dia.
S/o M.S flange of dia. 150 mm.
S/o MS All flanged 200 x 200 x 200 mm dia. Tee.
S/o M.S All flanged 150x150x150mm dia. Tee.
Welding and fitting of above item as per site requirement.
Supply of vacuum pump set DV-40 in standard construction with bronze impeller, stainless steel shaft, CI body, complete with base frame, coupling, coupling guard etc.Make:- Kirloskar/DJB approved. Supply of squirrel cage induction motor TEFC, 5 HP 1500 RPM, suitable to operate 400±10% Volts, 3 Phase 50Hz AC supply.Make: Kirloskar / Jyoti / Crompton/DJB approved.
Providing &Fixing of 40 mm dia G.I. medium class pipe , pipe fittings like socket ,elbow ,Tee ,union , x-nipple , GM gate valve 40 mm dia( 4 Nos.) 15 mm dia( 1 No) with required fittings and base frame , 500 Ltr PVC tank to be placed on roof.Make:-Pipe : Jindal / ISI marked ,Fittings:- R- Brand / ISI marked ,Gate Valve:- SANT/LEADER/ISI marked.
Supply of 19 mm thick high voltage insulation mats, Size 1M X 2M.
Supply of Pressure gauge 150 mm dia. 0-100 PSI , GI pipe fitting , stock cock , copper tube , wooden board on the suction & delivery of each pump. One complete set of 250 mm dia. pressure gauge 0-100 PSI on main header with all fittings etc. 150 mm dia. Make:- H Guru / Fiebig
Supply of fire extinguisher powder type 4.5 Kg capacity. Make:- Bharat / Nithi / ISI Mark
Supply of fire bucket 9 liter capacity with stand of 6 nos. bucket. Make:- Spink/Arihant/DJB approved
Supply of nut bolt as per site requirement.
Supply of Rubber Sheet for packing as per site requirement.
Supply of change over switch 320 Amp , 4 Pole . 415 Volts ,Confirms to IEC: 60974-III/IS : 13947-II Make:- Havells/ABB/ DJB Approved
Fabrication / Supply& fixing of retro reflective sign board made out of 40 x 40 x 6mm MS angle iron frame & 2 mm thick MS sheet & 50 mm dia. GI pipe for supporting the board. The size of board 4 mtr. X 1mtr. Including grouting of board in proper way. The board shall be duly painted & matter to be written as per the direction of engineer in charge.
Providing / fixing of ISMB 300 x 140 mm along the length (7 mtrs.) of pump house with ISI marked triple spur geared chain pulley block with greed 80 alloy steel load chain tested to 50% overload confirming to IS- 3832 - 9087 of 2 ton capacity with overhead monorail travelling trolley with 5 mtr chain mounted on ISMB 300 x 140 approx. 7 mtr long. SOR(E&M)-2024 Item Code-7.27.10. Make:-Indef / Morris / Avon / Hercules / Reva /DJB approved
Earthing with GI earth plate 600 mm x 600 mm x 6 mm thick including accessories & providing masonry enclosure with cover plate having locking arrangement & watering pipe of 2.7 mtr long etc with charcoal / coke & salt as required.
Making of RCC foundation for 2 nos. P/Sets with all material like steel, cement, concrete, Foundation Bolt& all other related civil work required to complete the pump house
Installation, testing & commissioning of all above E&M equipment. It includes laying of pipe line, Cable as per the instruction of engineer in charge. Itjob also includes cost of cartage, painting, watch & ward of the materials at site and minor items/Jobs required (reducer, socket etc.) for pump house operational &commissioning the same up to the satisfaction of engineer in charge with one year guarantee.
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.58 MB
BOQ_374618.xls
BOQ • 0.33 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .