| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹28.0 LAccepted-AOC BHU | ₹28.0 L Quoted ₹28.7 L | L1 | Accepted-AOC being lowest |
| 2 | L2₹29.8 L+₹1.1 L (3.93%)Rejected-Finance | ₹29.8 L+₹1.1 L (3.93%) | L2 | Rejected-Finance other than lowest |
| 3 | L3₹29.8 L+₹1.1 L (3.97%)Rejected-Finance | ₹29.8 L+₹1.1 L (3.97%) | L3 | Rejected-Finance other than lowest |
| 4 | L4₹30.7 L+₹2.0 L (7.02%)Rejected-Finance H NO 200 GIRJA NAGAR 37 BN P A C LINE KANPUR 208015 | KANPUR | KANPUR | UTTAR PRADESH | 208015 | ₹30.7 L+₹2.0 L (7.02%) | L4 | Rejected-Finance other than lowest |
| 5 | L5₹31.3 L+₹2.6 L (8.98%)Rejected-Finance | ₹31.3 L+₹2.6 L (8.98%) | L5 | Rejected-Finance other than lowest |
| Sl No | Description | Qty | Unit | DHARM ENTERPRISES L4 | keerti trading corporation L2 | Lalta Prasad vijay kumar Forwarding Agency L1 | Kumar Electricals L5 | AARADHIRAJ ASSOCIATES L3 |
|---|---|---|---|---|---|---|---|---|
| 1.00 | Taking down old unserviceable/deteriorated batten/PVC conduit copper/aluminium point wiring from existing place i.e. light, fan, socket or power points complete with all unserviceable fittings such as switches, sockets, ceiling rose, pendants, Holders, etc and making good all disturbed surface to wall, floor etc by means of cement mortar (1 : 3) or plaster of Peris and to match / finish new surface as the existing surface either by using same colour distemper, Putti or white / colour wash all as required and directed by Engineer-in-Charge. | 440 | Point | 20 ₹8,800 Lowest | 25 ₹11,000 | 30 ₹13,200 | 30 ₹13,200 | 50 ₹22,000 |
| 2.00 | M & L for concealed point wiring on wall and surface on ceiling/roof with necessary fixing arrangements with PVC-FRLS insulated and unsheathed copper multi-stranded conductor of size 1.5 Sqmm, 1100 volts grade drawn in existing conduit and Bakelite laminated sheet 3mm thick ISI marked for fixing of switches / sockets, fan regulators, wall mounting fittings, door bell & bulkhead etc with MS screw and cup washers including PVC-FRLS insulated and unsheathed copper multi-stranded conductor of size 1.5 Sqmm, 1100 volts grade for continuous earthing including cutting the chases and making good the surface by cement mortar (1:3) as and where received at site and for matching / finishing of new surfaces either by means of plaster of peris/ Putti or distemper / colour wash with same existing colour surfaces all as specified and directed by Engineer-in-Charge for the following :- For one light/ fan/ call bell. | 100 | Point | 450 ₹45,000 Lowest | 500 ₹50,000 | 465 ₹46,500 | 475 ₹47,500 | 600 ₹60,000 |
| 3.00 | All as per item no 3 here in before but for one socket point controlled by one switch on independent board. | 45 | Point | 450 ₹20,250 Lowest | 500 ₹22,500 | 475 ₹21,375 | 475 ₹21,375 | 610 ₹27,450 |
| 4.00 | All as per item no 3 here in before but for one socket point controlled by one switch on same board. | 30 | Point | 90 ₹2,700 | 100 ₹3,000 | 85 ₹2,550 Lowest | 100 ₹3,000 | 100 ₹3,000 |
| 5.00 | All as per item No.3 here in before but for power point wiring with 2.5 Sqmm PVC-FRLS insulated, unsheathed, copper conductor, stranded 1100 Volt grade cable and 2.5 Sqmm PVC-FRLS insulated, unshethed, copper conductor, stranded 1100 Volt grade cable as continuous earth lead. | 30 | Point | 540 ₹16,200 Lowest | 600 ₹18,000 | 550 ₹16,500 | 560 ₹16,800 | 650 ₹19,500 |
| 6.00 | All as per item no 3 here in before but for one light point controlled by 2 way switch complete all as specified and directed. | 20 | Point | 580 ₹11,600 | 600 ₹12,000 | 550 ₹11,000 Lowest | 600 ₹12,000 | 600 ₹12,000 |
| 7.00 | All as per item no 3 here in before but for bell buzzer point controlled by one push button on the same board with other switches of independent complete all as specified and directed. | 20 | Point | 780 ₹15,600 | 500 ₹10,000 | 465 ₹9,300 | 480 ₹9,600 | 410 ₹8,200 Lowest |
| 8.00 | M & L for surface point wiring on wall and surface on ceiling/roof with necessary fixing arrangements with PVC-FRLS insulated and unsheathed copper multi-stranded conductor of size 1.5 Sqmm, 1100 volts grade drawn in and including casing caping 20 / 25 mm white / ivory with all accessories/ fittings such as junction boxes, bends, tee, elbow etc including PVC / Polycarbonate gang box of appropriate size for fixing of switches / sockets, fan regulators, door bell & bulkhead etc with MS screw and cup washers including PVC-FRLS insulated and unsheathed copper multi-stranded conductor of size 1.5 Sqmm, 1100 volts grade for continuous earthing all as specified and directed by Engineer-in-Charge for the following :-For one light / fan/ call bell. | 80 | Point | 530 ₹42,400 | 500 ₹40,000 | 465 ₹37,200 Lowest | 480 ₹38,400 | 600 ₹48,000 |
| 9.00 | All as per item No. 9 here-in-before but for one socket point 5 Amp capacity controlled by one switch on independent board. | 40 | Point | 500 ₹20,000 | 500 ₹20,000 | 475 ₹19,000 Lowest | 480 ₹19,200 | 635 ₹25,400 |
| 10.00 | All as per item No. 9 here-in-before but for one socket point 5 Amp capacity controlled by one switch on same board with other switches including earth wire as specified and directed. | 40 | Point | 80 ₹3,200 Lowest | 100 ₹4,000 | 85 ₹3,400 | 100 ₹4,000 | 100 ₹4,000 |
Tender Value
₹30 L
EMD Value
₹60,000
Closing Date
14 Feb 2026, 6:00 pmClosed
GE(AF)EM Chakeri Kanpur
GE(AF)EM Chakeri Kanpur
REPAIR/MAINT OF INTERNAL ELECTRIFICATION WORKS AND REPAIR/ RENEWAL AND MAINTENANCE OF VARIOUS TYPES OF CEILING FANS, EXHAUST FANS AND CONNECTED ELECTRICAL ACCESSORIES WORKS AT SNCOS AND ORS MDD ACCN AT AGV AT AFS KANPUR
2026_MES_749877_1
8822/E8
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
Area under GE(AF)EM Chakeri Kanpur
As per tender document
9 documents required · 9 mandatory
₹500
GE(AF)EM Chakeri
₹60,000
Yes
15 Apr 2026
23 Jan 2026
19 Feb 2026
24 Jan 2026
14 Feb 2026
7 Feb 2026
Taking down old unserviceable/deteriorated batten/PVC conduit copper/aluminium point wiring from existing place i.e. light, fan, socket or power points complete with all unserviceable fittings such as switches, sockets, ceiling rose, pendants, Holders, etc and making good all disturbed surface to wall, floor etc by means of cement mortar (1 : 3) or plaster of Peris and to match / finish new surface as the existing surface either by using same colour distemper, Putti or white / colour wash all as required and directed by Engineer-in-Charge.
M & L for concealed point wiring on wall and surface on ceiling/roof with necessary fixing arrangements with PVC-FRLS insulated and unsheathed copper multi-stranded conductor of size 1.5 Sqmm, 1100 volts grade drawn in existing conduit and Bakelite laminated sheet 3mm thick ISI marked for fixing of switches / sockets, fan regulators, wall mounting fittings, door bell & bulkhead etc with MS screw and cup washers including PVC-FRLS insulated and unsheathed copper multi-stranded conductor of size 1.5 Sqmm, 1100 volts grade for continuous earthing including cutting the chases and making good the surface by cement mortar (1:3) as and where received at site and for matching / finishing of new surfaces either by means of plaster of peris/ Putti or distemper / colour wash with same existing colour surfaces all as specified and directed by Engineer-in-Charge for the following :- For one light/ fan/ call bell.
All as per item no 3 here in before but for one socket point controlled by one switch on independent board.
All as per item no 3 here in before but for one socket point controlled by one switch on same board.
All as per item No.3 here in before but for power point wiring with 2.5 Sqmm PVC-FRLS insulated, unsheathed, copper conductor, stranded 1100 Volt grade cable and 2.5 Sqmm PVC-FRLS insulated, unshethed, copper conductor, stranded 1100 Volt grade cable as continuous earth lead.
All as per item no 3 here in before but for one light point controlled by 2 way switch complete all as specified and directed.
All as per item no 3 here in before but for bell buzzer point controlled by one push button on the same board with other switches of independent complete all as specified and directed.
M & L for surface point wiring on wall and surface on ceiling/roof with necessary fixing arrangements with PVC-FRLS insulated and unsheathed copper multi-stranded conductor of size 1.5 Sqmm, 1100 volts grade drawn in and including casing caping 20 / 25 mm white / ivory with all accessories/ fittings such as junction boxes, bends, tee, elbow etc including PVC / Polycarbonate gang box of appropriate size for fixing of switches / sockets, fan regulators, door bell & bulkhead etc with MS screw and cup washers including PVC-FRLS insulated and unsheathed copper multi-stranded conductor of size 1.5 Sqmm, 1100 volts grade for continuous earthing all as specified and directed by Engineer-in-Charge for the following :-For one light / fan/ call bell.
All as per item No. 9 here-in-before but for one socket point 5 Amp capacity controlled by one switch on independent board.
All as per item No. 9 here-in-before but for one socket point 5 Amp capacity controlled by one switch on same board with other switches including earth wire as specified and directed.
All as per item No. 9 here-in-before but casing /caping for power point wiring with 2.5 Sqmm PVC-FRLS insulated, unsheathed, copper conductor, stranded 1100 volt grade cable and 2.5 Sqmm PVC-FR insulated, unsheathed, copper conductor, stranded 1100 volt grade cable as continuous earth lead.
S & F, for switch flush type single pole one way 5 Amps, 240 volts, white finish complete all as specified.
S & F, for switch flush type single pole two way 5 Amps, 240 volts, white finish complete all as specified.
S & F, for switch flush type 15 Amps, 240 Volts single pole white finish complete all as specified.
S & F , for socket outlet 5 pin, 5 Amps flush type white finish complete all as specified.
S&F, for socket outlet 2 in 1, 3 pin, 5/15 A, flush type universal, 240 V white finish complete all as specified.
S&F, electronic socket size, rotary, 5 speed step type regulator, 120-230 V white finish complete all as specified.
S&F, ceiling rose, surface backlite, 65 x 20 mm three terminal white finish complete all as specified.
Receiving complaints from JE incharge lodged by the user/occupants of internal electrific nature, rectification of the fault in respect of main distribution board having MCBs , MCB distribution board in sheet metal enclosure, point wiring fixture for light/fan /bell /light or power sockets, complete repair to the extend by removing connections from the system, rectyfying faults in (surface /concelled), circuits, main switches, MCBs/DBs any type of utility light fittings, lamp holders and other connected fixtures of internal electrification including providing stores as under as well as as insulation tape, screws, nuts as for the site requirement to rectify the fault with regard to complaint lodged and refixing of fitting and fixture to their original position complete all as specified and directed.
Note : (i) Any copmplaint which is left out/unattendent 1-2 days by the electrician by any means will be communicated to the JE incharge /AGE E/M with reason. (ii) New material/stores provided for completing the job shall be measured and paid for separetely under relevent items of BOQ. (iii) Contractor shall provide the all type of T & P to each electrician for attending the internal electric complaints. (iv) Contractor shall provide the complaint register and complaint slip serially numbered in duplicate.
S&F, in replacement, double door metallic sheet metal enclosure for DB when MCBs to be used SPN 8 ways, 240 V with 200Amps rated bus bar complete fixed properly on in concealed position and to provide required sizes of flexible conduit at any open surfaces near DBs of cables/wires all as directed.
Supply & fixing, testing and commissioning of MCB SP 240 volt 6 Amp to 32 amp 10 KA capacity having C-curve characteristics connected with suitable lugs fixed in repairs complete all as specified & directed.
All as per item No 21 but of DP 6 to 32 Amps.
All as per item No 21 but of DP 40 Amps.
All as per item No 21 but of TPN MCB 40 Amps.
S&F sheet metal enclosure , 20A single pole and neutral with a two pin and earth plug and socket complete in metal clad board (Industrial type) with one single pole MCB 20 Amp fixed properly on in concealed position all as directed by Engineer-in-Charge.
M & L sub main wiring with two single core PVC-FRLS insulated unsheathed multi stranded copper conductor cable of size 2.5 sqmm drawn in new/existing MS/PVC conduit with 2.5 Sqmm PVC-FRLS insulated unsheathed multi stranded copper conductor as a continuous earth wire complete all fixing accessories such as couplers lock, nuts, sadles, pipe hooks etc fixed properly including taking down old unserviceable sub main wiring complete. all as directed by Engineer in Charge. Note :-(i) Two single core cable and one run of earth copper conductor will be measured and paid as one unit length. (ii) PVC Conduit if required shall be measured and paid separately under respective item.
M & L sub main wiring with two single core PVC-FRLS insulated unsheathed multi stranded copper conductor cable of size 2.5sqmm drawn through in and incl suitable size PVC casing capping and all accessories fixed on wall/floors surface along with 2.5 sqmm PVC insulated unsheathed copper conductor multi stranded cable 1100V grade as earth continuity conductor and connected to common earth dolly including taking down UNSV old wiring all as directed by Engineer in Charge. Note : (i) Two single core cable, one run of earth copper conductor and one run of PVC casing capping will be measured and paid as one unit length.
M & L sub main wiring with two single core PVC-FRLS insulated unsheathed multi stranded copper conductor cable of size 4 sqmm drawn in new/existing MS/PVC conduit with 4 Sqmm PVC-FRLS insulated unsheathed multi stranded copper conductor as a continuous earth wire complete all fixing accessories such as couplers lock, nuts, sadles, pipe hooks etc fixed properly including taking down old unserviceable sub main wiring complete all as directed by Engineer in Charge. Note : (i) Two single core cable and one run of earth copper conductor will be measured and paid as one unit length. (ii) PVC Conduit if required shall be measured and paid separately under respective item.
M & L sub main wiring with two single core PVC-FRLS insulated unsheathed multi stranded copper conductor cable of size 4 sqmm drawn through in and incl suitable size PVC casing capping and all accessories fixed on wall/floors surface along with 4 sqmm PVC insulated unsheathed copper conductor multi stranded cable 1100V grade as earth continuity conductor and connected to common earth dolly including taking down UNSV old wiring all as directed by Engineer in Charge. Note : (i) Two single core cable, one run of earth copper conductor and one run of PVC casing capping will be measured and paid as one unit length.
M & L sub main wiring with two single core PVC-FRLS insulated unsheathed multi stranded copper conductor cable of size 6 sqmm drawn in existing MS/PVC conduit with 6 Sqmm PVC-FRLS insulated unsheathed multi stranded copper conductor as a continuous earth wire complete all fixing accessories such as couplers lock, nuts, sadles, pipe hooks etc fixed properly including taking down old unserviceable sub main wiring completeall as directed by Engineer in Charge. Note : (i) Two single core cable and one run of earth copper conductor will be measured and paid as one unit length. (ii) PVC Conduit if required shall be measured and paid separately under respective item.
M & L sub main wiring with four single core PVC-FRLS insulated unsheathed multi stranded copper conductor cable of size 6 sqmm drawn in existing MS/PVC conduit with two single core 6 Sqmm PVC-FRLS insulated unsheathed multi stranded copper conductor as a continuous earth wire complete all fixing accessories such as couplers lock, nuts, sadles, pipe hooks etc fixed properly including taking down old unserviceable sub main wiring complete all as directed by Engineer in Charge. Note : (i) Four single core cable and two single core of earth copper conductor will be measured and paid as one unit length. (ii) PVC Conduit if required shall be measured and paid separately under respective item.
S&F rigid non metallic medium white / ivory PVC conduit medium grade ISI marked of size not less than 20 mm dia concealed position inclusive all fitting such as tee, bends, reducer, elbow, bell mouth, tube ends and all fixing accessories such as couplers lock, nuts, saddlers, pipe hooks etc fixed properly on as in concealed position incl cutting chasing & making good to disturbed surfaces & matching with the existing colour of wall/floor etc all as directed by Engineer-in-Charge.
All as per item No 32 here-in-before but 25 mm dia PVC conduit medium grade ISI marked
M & L in replacement for energy saver LED light fitting 40 watt, 230 Volts, single tube mounting including LED Tube/ LED blocks 40 Watt ,Lumen OUTPUT NOT LESS THEN 100 LM /WATT with 50000 burning Hours, PF = 0.95 complete with electronic driver LED Printed board, end cover, connector box etc and accessories, prewired, LED including required fixing arrangements and electrical connection three core copper cable from ceiling rose to led light fitting all as directed by Engineer in Charge. Make: PHILIPS BN100C LED 40S-6500 PSU L120GR or equivalent in Wipro Cat No LL24-541-XXX-57-XX / GE
M & L in replacement energy saving LED 4ft Batten 20/22 Watt with a nominal system lumen output of 2400/2500 lumens and a minimum system efficacy of 100 lm/W with fixing arrangements and electrical connection three core copper cable from ceiling rose to light fitting and removing UNSV . The luminaire shall have a rate system lifetime of 40,000 burning hours at L70.. The luminaire shall meet IP 20 rating and PF > 0.95. all as directed by Engineer in Charge.
M & L in replacement energy saver LED smart batten fiting 10 Watt, 230 V, box type etc and accessories, including required fixing arrangements and electrical connection three core copper cable from ceiling rose to light fiting and removing unsv backet with sketch fitting all as directed.
S&F in replacement Endural LED bulk head fitting Plastic Body, heat resistant, with specially designed gasket all as per directed by Engr- in - charge. Make : Philips Cat pat- WT140W LED7S NW PSU S1 PC or equivalent in Wipro /GE
Supply only in replacement carried out in day to day complain of switch piano flush type 5/6 Amps one way AC 230 Volts complete all as specified and directed.
Supply only in replacement carried out in day to day complain of switch piano flush type 15/16 Amps one way AC 230 Volts complete all as specified and directed.
Supply only in replacement carried out in day to day complain of bell push 5 Amps, AC 230 Volts complete all as specified and directed.
Supply only in replacement carried out in day to day complain of socket outlet 2 in 1, 6 pin 15 Amp flush type (Multi purpose) AC 230 Volts complete all as specified and directed.
Supply only in replacement carried out in day to day complain of socket outlet 2 in 1, 5 pin 5 Amps flush type (Multi purpose) AC 230 Volts complete all as specified and directed.
Supply only in replacement carried out in day to day complain of electronic fan regulators flush type on the exiting phenolic laminated sheet etc complete all as specified and directed.
Supply only in replacement of carried out in day to day complain of ceiling rose 65x50mm two to three terminal AC 230 volts complete all as specified and directed.
Supply only in replacement carried out in day to day complain of buzzer,AC, 230 volts, single phase complete all as specified and directed.
Supply only in replacement bell, ding dong, AC, 230 volts, single phase complete all as specified and directed.
Supply only in replacement carried out in day to day complain of lamp holder insulated body with back plate batten/angle type for batten fittings complete all as specified and directed.
Supply only in replacement carried out in day to day complain of electronic ballast 36/40 watts 230 volts complete all as specified and directed.
Supply only in replacement carried out in day to day complain of MCB SP, 6 to 32 Amps 10 KA single pole AC 230 volts complete all as specified and directed.
Supply only in replacement carried out in day to day complain of MCB SPN 20 to 40 Amps 10 KA AC 230 volts complete all as specified and directed.
Supply only in replacement carried out in day to day complain of MCB TPN, 415 Volts, 25 TO 40 Amps complete all as specified and directed.
Supply only in replacement carried out in day to day complain of for LED bulb of capacity not less than 10 watt suitable for lamp holder complete all as specified and directed.
Supply only in replacement carried out in day to day complain of metal plug socket industrial 2 pin and earth plug of 20 Amps 230 V suitable for AC box/Gyser complete all as directed.
Supply, fixing in replacement of MCCB 63 Amps, 4 Pole, 415V, 25 kA , Ics =100 % Icu -do-. Make : Havells Cat No IHLE1ABF00663 or equivalent in Schiender/ABB
Supply, fixing in replacement of MCCB 40 Amps, 4 Pole, 415V, 20 kA , Ics =100 % Icu -do-. Make : Havells Cat No IHLE1ABF0040 or equivalent in Schiender/ABB
Supply, fixing in replacement of TPN MCCB 100 Amp, 4 Pole, 415 V, 25 KA ICS = 100% Icu --do- Make : Havells cat No. IHLE1AB40100 or equivalent in Legrand/ ABB/ Schiender
Taking out with S & F electronic meter tamper proof,LCD display, polycorbonate cover 230 V 10 to 60 amp accuracy class I , 50 Hz confirming to IS 13779 IP54 with parameter to show data, time, current reading, load, PF, Voltage, KWH all as directed by Engineer in Charge.
All as per item No. 57 but 3 Phase electronic meter
Taking down from site or collecting unserviceable ceiling fan of any sweep and make from existing position, transporting to local wksp, cleaning external portion with washing soda for removing oily stain, opening and cleaning internal portion with kerosene oil, drying it out, oiling / greasing properly, dismentling unserviceable bearing / bush / rubber bush for arm with nuts & clamp / flexible wire and replacing under respective item of schedule A and reassembling ensuring speedy and noiseless run and hanging the same at site complete all as directed. Note :- Spares if required shall be measured and paid separately under respective items.
All as per srl No 59 above but of exhaust fan any make and any size complete all as specified.
M & L for Preparation of old painted surfaces of ceiling fan of any make and size and applying one coat of synthetic enamel white paint of superior quality as approved by Accepting officer by spray painting including writing MES/SM Number of fan with black paint / Black Permanent Marker Pen in approprieate size of font complete all as specified and directed by Engr-in-Charge.
M & L for Preparation of old painted surfaces of exhaust fan of any make and size and applying one coat of synthetic enamel white paint of superior quality as approved by Accepting officer by spray painting including writing MES/SM Number of fan with black paint / Black Permanent Marker Pen in approprieate size of font complete all as specified and directed by Engr-in-Charge
S & F in Replacement of canopy (top and bottom) of ceiling fans any make / size with canopy of matching colour complete all as directed by Engr-in-Charge
S & F in Replacement of rubber reel with nut, bolts, split pins etc of ceiling fan with rubber reel heavy duty for hanging fan complete all as directed by Engr-in-Charge
S & F in replacement of factory made down rod with clamps etc of ceiling fan with down rod of 15 mm bore medium grade GI pipe 0.30 metre long with clamps, GI bolts, nuts, split pins washers of suitable size of approved quality all as per specified and directed by Engineer in charge.
S & F in replacement of PVC connector block of ceiling fan of suitable size as per sample at site all as directed by Engr-in-Charge.
S & F in replacement capacitor of capacity 2.5mfd, 240 Volts, AC all as directed by Engr-in-Charge
S & F in replacement factory made blade of ceiling fan of any make duly painted of sweep 1200mm including provision of screws etc fixing purpose complete all as specified and directed by Engineer -in-charge.
Supply & Replacement of cable/wire for connection of fan with flexible copper cable 3 core of size 23/0.0076 all as directed by Engr-in-Charge.
Taking down ceiling fan 1200 mm sweep and after disconnecting the cable/wire connection from the existing alignment (after detecting and declaring the winding wire burnt) and deposited to AGE E/M-III store yard.
Taking down exhaust fan 300 mm sweep complete with louvers from the existing aligment (after detecting and declaring the winding wire burnt) and deposited to AGE E/M-III store yard.
Supply and fixing ceiling fan complete with three blade, down rod and connected accessories 230V, 1200 mm sweep with squirrel cage induction motor including testing with staplized voltage through regulator to entire satisfaction of user/concern all as directed by Engineer in Charge.
Supply and fixing exhaust fan complete with blade, steel body AC single phase 230V of size 300 mm sweep with frame and louvers with nut bolts including testing complete to satisfaction of user/concern complete all as directed by Engineer in Charge.
stage.html
html • 0.05 MB
technical_839814.pdf
techsummary_839814.pdf
finance_839814.pdf
BOQ Comparative Chart
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 2.05 MB
8822E8_CreditSchdule_1.pdf
Additional Documents • 0.18 MB
BOQ_839814.xls
BOQ • 0.43 MB
8822E8_Tender_1.pdf
Tender Documents • 0.82 MB
Tender_Acceptance_Letter.pdf
Additional Documents • 0.08 MB
Workdetails.pdf
Additional Documents • 0.09 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .