| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹42.3 LAccepted-AOC | L1 | Accepted-AOC ACCEPTED DUE TO LOWEST | |
| 2 | L2₹44 L+₹1.6 L (3.81%)Rejected-AOC | L2 | Rejected-AOC REJECTED DUE TO NOT LOWEST | |
| 3 | Rejected-Technical 10 MAKHAN LAL SADHUKHAN LANE PO PS BARRACKPORE KOLKATA 700120 W B | KOLKATA | NORTH 24 PARGANAS | WEST BENGAL | 700120 | - | Rejected-Technical NOT ENLISTED IN ELIGIBLE CATEGORY |
Tender Value
₹40.8 L
EMD Value
₹81,500
Closing Date
15 Nov 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE (AF) LOHEGAON
GE (AF) LOHEGAON, PUNE -411032
PROVISION OF CERTAIN SANCTIONED WORKS AND MINOR WORKS AT 9 BRD AIR FORCE STATION PUNE
2021_MES_472147_2
8508/E8
Open Tender
Civil Works
Item Rate
270 days
GE (AF) LOHEGAON
As per NIT
8 documents required · 8 mandatory
₹500
Yes
GE (AF) LOHEGAON
₹81,500
Yes
15 Jan 2022
28 Oct 2021
22 Nov 2021
28 Oct 2021
15 Nov 2021
3 Nov 2021
60 days
Amount
Excavation in trenches n.exc 1.5m wide and n.exc 1.5m in depth for foundations, manholes etc and getting out Hard/dense soils complete all as specified and directed
Returning filling in including spreading levelling watering and well ramming in layers n.exc 25cm in Hard/dense soils complete all as specified and directed.
Removing the excavated surplus soils exceeding 50mtr but N.exc 250 mtr and depositings where directed at a level n.exc 1.5 mtr above the starting point complete all as specified and directed
M&L for PCC (1:4:8) type D-2 using 40mm graded aggregate as mass concrete as in foundation as required on site complete all as specified and directed
M&L for Reinforced cement concrete Type B1 1:2:4 using 20 mm graded aggregate in Foundations, including rafts, footings, foundation beams, plinth beams, bases for columns, etc. basement slabs, under-reamed piles and mass concrete complete all as specified and directed
M&L for Reinforced cement concrete Type B1 1:2:4 using 20 mm graded aggregate in Beams, cantilevers, bressummers, lintels over 1.5m span complete all as specified and directed
M&L for Formwork to sides of flat and rough finished surface concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams and similar work, vertical or to batte complete all as specified and directed
M&L for Formwork to edges of concrete flats, treads, breaks in floors, window cills, concrete railings, openings in concrete walls, floor and roofs n exc 20 cm wide and sides of RCC/ PCC bands in walls, horizontal or sloping and similar work exc 10cm but n exc 20cm wide for fair finished concrete complete all as specified and directed
M&L for mild steel TMT bar 10mm dia and over, cut to length,bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with including mils steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed
M&L for mild steel TMT bar 8mm mm dia and over, cut to length,bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed
M&L for 40 mm thick Damp proof course to horizontal or vertical surfaces including necessary formwork in Cement concrete B0 type 1:2:4 with 12mm graded agregate complete all as specified and directed
S & F Roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc. Fe-410W(GdeE-250) quality B complete all as specified and directed
S & F Joist, channel, angle, or tee sections, fixed independently, without connecting plates, etc. (cut to ordinary lengths i.e. within 20mm of the length indicated) Fe-410W(GdeE-250) quality B complete all as specified and directed
S & F Plates (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes, without any attachment Fe-410W(GdeE-250) quality B complete all as specified and directed
M&L for two coats of synthetic enamel painting over a coat of red oxide primer on new steel surfaces of any description over 10 cm width or girth complete all as specified and directed
M&L for modular Brick work with sub- class ‘B’ bricks, straight or curved on plan exc 6m mean radius, built in cement mortar 1:6 complete all as specified and directed
S & F Solid PVC Door Frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with M.S. Square tube, suppling & fixing in opening as per specification & drawing complete all as specified and directed
S&F Factory made solid panel pvc door shutter 30mm thick (style) consisting of frame made out of ms tubes for top &bottem rails, ms frame shall be covered with heat moulded plain colour PVC 'C' channel having a pvc sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour pvc sheetfor top rail ,lock rail, &bottem rail, on either side & as gap insert for top rail , panneling of plain colour pvc sheet to be fitted in the ms frame welded /sealed to the stiles & rails with suitable pvc sheet beading, &jointed together with solvent cement suppling & fixing in the frame at site as per spacification &drawing complete all as specified and directed.
S&F 100 mm long butt hinges, medium weight, and cold rolled mild steel complete all as specified and directed.
S&F 150 mm long aluminum anodised barrel tower bolts of extruded section complete all as specified and directed.
S&F 125 mm aluminum alloy handles, cast type, anodized complete all as specified and directed.
S&F in repairs 300 mm long Mild steel sliding door bolts, plate type, stove enamelled black, with bright bolt not less than 12mm dia with and including a minimum of 6 bolts and nuts, four on bolt plate and two on staple plate and fixed complete all as specified and directed.
Supply and fix, as vitreous china squatting pan of Orrisa pattern size 580mm x 440 mm white with integral foot rests (excluding flushing cistern and flush pipe) including connection making good to floor complete all as specified and directed.
S&F 10 ltrs capacity PVC valve less syphonic action type, low level flushing cistern, white with inlet, ball valve float and handle including brackets complete all as specified and directed.
Supply and fix, vitreous china wash basin, white flat back size 550 x 400 mm, excluding taps, waste chain, plug and porcelain stopper but including brackets, cutting for and pinning in ends of bracket or erecting stand complete all as specified and directed.
Supply only 15 mm bore pillar taps fancy type (long neck) cast copper alloy with capstan heads chromium plated screwed down high pressure with or without letter hot or could with long screwed and shanks and fly nuts screwed for iron pipes complete all as specified and directed.
S&F for 15 mm bore stop valves cast copper alloy screwed down high pressured with batterfly handle screwed both ends for iron pipes fancy type choromium plate with long shunk and cup (concealed type) complete all as specified and directed.
S&F for 15 mm bore angle stop valves of PTMT any colour high pressure screwed for iron pipe and fixed (minimum weight 15mm 90gms) complete all as specified and directed.
S&F for 15 mm bore push tap any colour high pressure PTMT screwed for iron pipe and fixed (minimum weight 15mm 47gms) complete all as specified and directed.
S&F for bib tap 15 mm bore fancy chromium plated with long shank & cup complete all as specified and directed.
S&F for 75mm PVC (SWR) multi floor trap with grating including jointing with solvent cement complete all as specified and directed.
M&L for 75mm PVC (SWR) floor trap, plain with grating including jointing with solvent cement complete all as specified and directed.
Supply and fix ,Towel rail 450 mm long of PTMT fixed with and incl chromium plated brass screws and wooden/ plastic cleat ( min weight 170 gms) complete all as specified and directed.
S&F LDPE waste pipes of 32mm bore pressure rating 6 Kgf/Sqcm for wash hand basin complete all as specified and directed.
S&F PVC connection 15mm dia sizes with PTMT nuts of length 450 mm complete all as specified & directed.
S&F soap disk stainless steel complete all as specified and directed.
S&F High density polythene pipe(HDPE)of pressure rating 6 Kgf /Sq cm fixed comp to wall or laid in tranches or under floors (50 mm bore) incl all fittings complete all as specified and directed.
S & F PVC (SWR) pipes single socketed 75mm dia in any length with rubber ring joints complete all as specified and directed.
S & F PVC (SWR) pipes single socketed 110mm dia in any length with rubber ring joints complete all as specified and directed.
S & F PVC (SWR) bend 110mm dia with access door bends complete all as specified and directed.
S & F PVC (SWR) bend 75mm dia with access door bends complete all as specified and directed.
S & F PVC (SWR) gully trap 110 mm dia fixed in cement concrete and providing connection upto 1st manhole with PVC pipe complete all as specified and directed.
S & F PVC (SWR) P traps bore 125 mm dia complete all as specified and directed.
S&F grating doom 150mm size of PTMT for wash basin complete all as specified and directed.
Cutting into existing manholes for connecting nw drains and rendering, cutting out branch channel and making good in PCC (1:2:4)150 mm Bore( Internal diameter ) complete all as specified and directed.
Extra forming fair finished drain channel inner girthe n.exc 30 CM in cement incl forms, moulds, mitred stops/ends etc complete all as specified and directed.
M&L RCC precast (1:2:4) type B1 using 20 mm graded stone aggregate in Manholes covers set in CM 1:4 complete all as specified and directed.
Material and labour for white Non - skid Ceramic Coloured tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.06 sqm but not exceeding 0.11 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specified and directed.
M&L for white Glazed ceramic tiles in vertical surface 350x 250x 7 mm/ 450X 350X 7mm thick set and jointed in neat cement slurry and pointed in white or colour cement to matchin colourd cement to match including backing coat CM 10mm 1:6 complete all as specified and directed.
M & L for rendering 10mm thick in CM 1:6 finished even and smooth without using extra cement with sagol finished complete all as specified and directed.
Material and labour for 15 mm thick rendering in cement mortar (1:6) on fair face of brick or concrete surface finished even and fair complete all as specified and directed.
Material and labour for applying two coats of oil bound distemper over a coat of 1mm wall care putty on walls including preparation of new or previously untreated surfaces complete all as specified and directed.
Material and labour for applying two coats of Cement Base Paint over a coat of Chalk whiting on walls including preparation of new or previously untreated surfaces complete all as specified and directed.
S & F for GI tubing medioum grade with all fittings concealed to wall or laid in floors 15 mm bore complete all as specified and directed.
S&F Pre-painted galvanume aluminium zinc coating GI bashed corrugated steel sheeting 0.50mm th of any colour having tensile strength 550 Mpa as in roof covering/clading of wall , fixed with self tapping screw complete all as specified and directed.
S&F Pre-painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed.
M&L for Anodised aluminium powder coated snap grid frame work for false ceiling as per manufacturer specification and Gypsum Board 12mm thick in ceiling fixed with screw as per manufacturers instruction complete all as specified and directed.
M&L Powder coated for powder coating of any colour (Thickness or powder coating not less than 50 micron). Anodised aluminium window and ventilator shutters, fixed type without sash bar, aluminium section weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws etc. complete all as specified .(sealing of window/door frames with sillicon gel to avoid rain water entry) complete all as specified and directed.
S & F galvanised mild steel wire cloth 0.63 mm nominal dia of wire and average width or aperture 1.40mm and fixed with tinned tackles or galvanised wire complete all as specified and directed.
S&F 3mm Figured glass, pin head type and glazing with oil putty in squares n exc 0.5 sq. m in each pane complete all as specified and directed.
S & F Sheet Glass, Ordinary quality in squares exc 0.5 sqm each pane 5.5 mm Thick including necessary rubber beading complete all as specified and directed.
M&L RCC pipes class NP-2 laid and jointed complete with collars with following sizes laid on old/new PCC bed 150mm nominal bore complete all as specified and directed.
M&L for concrete bed to150mm bore pipe PCC 1:4:8 type D2 using 40mm graded agg to drain pipes incl packing under and haunching against the sides after they are laid & tested complete all as specified and directed.
Excavating in post holes (or similar holes) each n exc 0.5 cu. m, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm, hard and dense soil complete all as specified and directed.
M&L for Cement concrete 1:3:6 C2 type 40 mm graded aggregate in foundations as required on site, filling and mass concrete complete all as specified and directed.
Fixing only chain link fencing including line wires, any mesh, size and type to any type of standards, rails, straining bolts, etc. including provision of binding wire complete all as specified and directed.
M&L for Chain link MS galvanisd fencing , any size or type complete all as specified and directed.
M&L for Galvanised. 2 strand, steel barbed wire 2.24mm dia barbed with 2mm dia barbs at 75mm spacings and straining and fixing to any type of standard rails strain- ing bolts, including, securing or tying at crossings with and provision of galvanised mild steel wire, staples or steel pins, etc. as directed (each line wire to be measured) complete all as specified and directed.
M & L for Deformed and twisted Mild steel bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed.
M&L for preparation of new steel surfaces and applying two coats of synthetic enamel painting over a coat of red oxide primer on new steel surfaces of any description over 10 cm width or girth complete all as specified and directed.
Surface excavation in hard and dense soil n.exc (not exceeding) 30 cm deep and averaging 15cm deep and getting out hard dense soil complete all as specified and directed.
M&L for 75mm Cement concrete 1:4:8 D2 type 40 mm graded aggregate in foundations, filling and mass concrete complete all as specified and directed.
M&L 50 mm Sand cushioning under floors or in foundations including watering and consolidation complete all as specified and directed.
M&L Machine pressed precast concrete interlocking paver block any shape and size confirming to IS 15658-2006 of 60 mm thickness, M-35 Grade with grey cement and pigment complete all as specified and directed.
Providing and laying at or near ground level factory made kerb stone of M-25 grade cement concrete in position to the required line, level and curvature, jointed with cement mortar 1:3 (1 cement: 3 coarse sand), including making joints with or without grooves (thickness of joints except at sharp curve shall not to more than 5 mm), including making drainage opening wherever required complete throating etc. and setting in mortar complete with joints to match complete all as specified and directed.
Removing excavated material n exc. 50m and depositing where directed at a level n exc. 1.5 m above the starting point
Excavation in trenches n.exc 1.5m wide and n.exc 1.5m in depth for foundations, manholes etc and getting out in Soft/loose soil complete all as specified and directed.
Material and labour for Non - skid Ceramic Coloured tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.06 sqm but not exceeding 0.11 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specified and directed.
M&L for joint free Glazed white ceramic tiles in vertical surface 350x 250x 7 mm/ 450X 350X 7mm thick set and jointed in neat cement slurry and pointed in white or colour cement to matchin colourd cement to match complete all as specified and directed.
S & F Sheet Glass, Ordinary quality 5.5 mm Thick including necessary rubber beading in sqmm n.exc 0.5 sqm each pane complete all as specified and directed.
Surface excavation n.exc. 30 cm deep and averaging 15 cm deep and getting out in soft/loose soil complete all as specified and directed.
M&L 100 mm thick PCC 1:4:8 (using 40mm graded stone aggregate) as sub base complete all as specified and directed.
M&L Rubber moulded Machine pressed precast concrete interlocking paver block any shape and size confirming to IS 15658-2006 of 60 mm thickness, M-35 Grade with grey cement no pigment complete all as specified and directed.
Excavating in post holes (or similar holes) each n exc 0.5 cu. m, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm, watering, and removing surplus soil to a distance n.exc 50m and making good surface in sot/ disintegrated rock complete all as specified and directed.
S&F Rolled sections as in coloums, vertical posts etc. fixed with angle cleats or other connecting plates Fe 290 (Gde E-165) complete all as specified and directed.
S&F Roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc (Gde E-250) Quliaty A complete all as specified and directed.
M&L 12 mm Mild steel screw bolts (machine made) with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, exc 5cm but n exc 10cm long complete all as specified and directed.
S&F MS for wind tie for roof including securing bolts including all necessary drilling bolting or riveting etc and similar work conforming to Fe-290 Gde-E-165 complete all as specified and directed.
M&L two coat of synthetic enamel painting on surface of any description n exc 10 cm in width or girth when unconnected with other painting or when painted in a different tint complete all as specified and directed.
M&L for Pre-cast cement concrete block masonry with solid blocks, exc. 10 cm of type C1 1:3:6 using 20mm graded aggregate in width and setting in mortar 1:6 complete all as specified and directed.
Material and labour for 15 mm thick rendering in cement mortar (1:6) on fair face of brick or concrete surface finished even and fair all complete all as specified and directed.
M&L for 40mm coping concrete 1:2:4 B0 type 12.5mm grade aggregate complete all as specified and directed.
Material and labour for providing point wiring with two runs of 1.5 Sqmm multi stranded copper conductor FRLS PVC insulated single core 1100 volts grade & with one run of 1.5 Sqmm single core multi stranded copper conductor FRLS PVC insulated 1100 Volts grade wire for continuous earthing complete in and including PVC casing and caping with all fittings/fixture etc and open recessed type Plastic Enclosure( Plastic Switch Board ) ISI Marked (IS:14772) for housing switches / sockets complete all as specified and directed.
One light point controlled by one switch.
One Exhaust/Ceiling fan point controlled by one regulator/switch
Material and labour for providing point wiring with two runs of 2.5 Sqmm multi stranded copper conductor FRLS PVC insulated single core 1100 volts grade & with one run of 1.5 Sqmm single core copper stranded FRLS PVC insulated 1100 volts grade wire for continuous earthing complete in and including PVC casing and caping 25mm size with all fittings/fixture etc fixed wall and open recessed type Plastic switch board) made of robust Synthetic material Fire Proof, Anti corrosive & shock proof ISI Marked complet for housing one 15 A Switch / sockets complete all as specified and directed.
Supply and fix sheet metal enclosure MCB DB double door SPN 4 way 230 V with neutral link and with 200 A bus bar complete all as specified and directed.
Supply and fix MCB SPN 40 Amp, 230 volt 'C' series complete all as specified and directed.
S&F MCB SP 240 volt 6 to 32 A 'C' series complete all as specified and directed.
Supply and fix switch piano flush type 5 A one way complete all as specified and directed.
Supply and fix switch socket combination multipurpose 5 Pin 5 Amps complete all as specified and directed.
Supply and fix switch socket combination multipurpose 3 pin 6/16 Amps complete all as specified and directed.
Supply and fix ceiling rose surface type bakelite/PVC three terminal 65x50mm complete all as specified and directed.
Supply and fix high quality indoor Surface and wall mounted LED batten 20 Watt, extruded aluminium housing provided for efficient heat dissipation with polycarbonate diffuser & integrated electronic driver with industrial grade heavy duty driver having THD<10%. complete with all accessories internally pre-wired and including connecting up with three core 0.5 Sqmm flexible copper conductor cable ceiling rose to fitting terminal.
Supply and fixing LED light fitting mirror type with high out put diffuser 2 feet, 10 watt 220 V AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed.
S&F angle / batten holder insulated body with back plate for batten fittings complete all as specified and directed.
Supply and fix heavy duty exhaust fan 380mm sweep, 1400 RPM, turbo force SP, 230 volts complete all as specified and directed.
M& L for cutting hole of suitable size for exhaust fan of given size and making good existing wall complete all as specified and directed.
Supply & fix fans ceiling complete with electronic type regulator and accessories 230 V , 1400 mm sweep complete all as specified and directed.
M & L for sub main wiring with two runs of single core 4.0 Sq mm FRLS PVC insulated unsheathed multi stranded copper conductor 650 / 1100 V grade with colour code and one run of 2.5 Sq mm ( 22 / 0.3 mm ) single core FRLS PVC insulated unsheathed multi stranded copper conductor green colour cable as earth continuity conductor including PVC casing & caping complete all as specified and directed. ( Note :Two runs of 4.0 Sqmm copper cable,one run of earth wire of 2.5 Sqmm copper cable and one run of PVC casing and capping shall be measured & paid as one length.)
Supply, laying and testing cable XLPE insulated screened PVC bedded, GI steel strip or wire armoured, electric power cables (heavy duty) with standard aluminium conductor, 1100 volts grade of size 2 core 10 Sqmm complete all as specified and directed.
Material and labour for stone dust sand cushioning to under ground cable, provided with a layer 8 cm before and 15 cm after laying and stretching jointing and testing the cable all as specified and directed. [Note : Measuremenet will be done after punning]
Supply and fix GI Pipe Light grade with all connected accessories of sizes 40 mm complete all as specified and directed.
Supply, Install, Test and Commissioning of LT panel outdoor type fabricated out of 3.0 mm thick CRCA sheet double door(front & back opening), CPRI approved complete with powder coating with seven tank process mounted on M.S angle Iron frame of size 50x50x6mm, duly grouted with PCC foundation reqd with the following:- (a) copper bus bar 1000 Amp (R Y B & N) with coloured heat shrinkable insulated sleeve 415 Volts as per IS of suitable size mounted on DMC/epoxy insulator (not less than 50mmx50mm conicle type at a maximum interval of 500 mm- 01 Set. (b) MCCB 400 Amps 4 POLE 415 V (50 KA) -02 Nos (c ) MCCB 250 Amps 4 pole 415 V A (36 KA)- 03 Nos (d) MCCB 160 Amps 4 pole 415 V (25 KA) - 02 Nos (e) MCCB 100 Amps 4 pole 415 V (25 KA-03 Nos (f) MCCB 63 Amps 415 V (18 KA) - 06 Nos (g) MCCB 40 Amps 415 V (18 KA)-03 Nos (h) MCCB 40 A DP 230 Volts 25 kA- 02 Nos (j) ON Load Change Over 400 Amps - 01 Nos (k) LED indicator for RYB of size 22.5 mm - Set of 3 (l) 3 Phase Digital voltmeter -01 nos (m) 3 Phase Digital ammeter-01 Nos (n) Digital frequency meter - 01 Nos Note: (i) Seprate chamber shall be provided for each MCCBs and All MCCBs above 160 Amps equivalent to model No MTX2.0 of make L & T and must conforms micro processer based adjustable type and should have adjustable overload setting from 0.4 to 1.0 x In, Adjustable short circuit setting from 1.5 to 8 x Ir, inbuilt ground fault protection from 20% - 50% of In and adjustable neutral overload protection from 50% to 150% Ir (ii) MCCBs 100 Amps & 160 Amps should be thermal magnetic release type and should have adjustable overload setting from 0.67 to 1.0 x In and adjustable short circuit setting from 6-12 x In
Supplying ,Laying, jointing, testing and commissioning of LT under ground cable 1100 volts grade XLPE (cross linked polythene ) armoured with galvanised round steel wire or steel strip , electric power cable heavy duty, with multi stranded aluminium conductor, laid in trenches, ducts fix on walls/poles with proper size saddles and clamp laid under roads/path/ drain /colverts or enclosed in GI pipe/ fix complete all as specified and directed for following size:-
400 Sqmm 31/2 core
120 Sqmm 31/2 core
95 Sqmm 31/2 core
70 Sqmm 31/2 core
50 Sqmm 31/2 core
35 Sqmm 31/2 core
25 Sqmm 4 core
Excavation in trenches not exc 1.5 m wide and not exc 1.5 m in depth and getting out Soft/disintegrated rock for laying of cable / pole etc. complete all as specified and directed.
M&L for brick protection covers laid over cables of sub class'B' bricks old size (230X115X75) mm complete all as specified and directed.
Supply and fix GI Pipe Light grade with all connected accessories of sizes 100 mm complete all as specified and directed.
Supply and fix GI Pipe Light grade with all connected accessories of sizes 80 mm complete all as specified and directed.
M&L for cement concrete (1:2:4) type B1 in foundation filling and mass concrete and coping of poles incl necessary form work using 20 mm graded stone aggregate etc or as required on site etc complete all as specified and directed.
Supply and labour for Brickwork with sub class ‘B’ bricks, straight or curved on plan exc 6m mean radius built in cement motar 1: 4 for laying of under ground cable duct complete all as specified and directed.
M & L for cement plaster work 10 mm thick in 1:4 Rendering on fair faces of brick work or concrete surfaces including 5 mm thick finishing to be carryout one even and smooth surface (without usingextra lime or cement) complete all as specified and directed.
M & L for MS angle iron 50x50 x 5 mm and MS steel chequred plate of thickness 5 mm for cable duct cover complete all as specified and directed.
M & L for painting of MS angle and MS Chackered Plate by applying one coat of red oxide primer and two coat of black bituminius paint on surface complete all as specified and directed.
M & L for preparation of surface and applying of two coats of cement based distemper on walls of cable duct complete all as specified and directed.
Tools & Labour for making through hole upto 450 mm thick in wall of stone masonry for inserting of GI Pipe upto 100 mm dia for passing of UG cables of any size including making good the disturbed portion of wall to match existing surface complete all as specified and directed.
S & F MCCB 250 Amps 4 Pole 415 Volts 36 kA microprocessor release type same as in outgoing of Ser Item No 114.00 (c) with sheet Metal Enclosure complete all as specified and directed.
S & F MCCB 160 Amps 4 Pole 415 Volts 25 kA thermal release type same as in outgoing of Ser Item No 114 (e) and (f) with sheet Metal Enclosure complete all as specified and directed.
S & F MCCB 100 Amps 4 Pole 415 Volts 5 kA thermal release type same as in outgoing of Ser Item No 114 (e) and (f) with sheet Metal Enclosure complete all as specified and directed.
S & F MCCB 63 Amps 4 Pole 415 Volts 18 kA thermal release type with sheet Metal Enclosure complete all as specified and directed.
S & F MCCB 40 Amps 4 Pole 415 Volts 18 kA thermal release type with sheet Metal Enclosure complete all as specified and directed.
S&F Vertical double door Distribution board TPN 4 way 200 A rated busbar suitable for incomming MCCB and Out going MCBs including MCCB 160 A TPN 36 kA complete all as specified and directed.
S&F Vertical double door Distribution board TPN 8 way 200 A rated busbar suitable for incomming MCCB and Out going MCBs including MCCB 200 4 Pole 36 kA complete all as specified and directed.
Supply and fix sheet metal enclosure MCB DB double door SPN 8 way 230 V with neutral link and with 200 A bus bar complete all as specified and directed.
Supply and fix sheet metal enclosure MCB DB double door SPN 12 way 230 V with neutral link and with 200 A bus bar complete all as specified and directed.
Supply and fix sheet metal enclosure MCB DB double door SPN 16 way 230 V with neutral link and with 200 A bus bar complete all as specified and directed.
Supply and fix MCB SPN upto 40 Amps 230 volt 'C' series complete all as specified and directed.
Supply and fix MCB SPN 63 Amp, 230 volt 'C' series complete all as specified and directed.
Supply and fix MCB TP 63 Amp, 415 volt 'C' series complete all as specified and directed.
Supply and fix MCB TP 40 Amp, 415 volt 'C' series complete all as specified and directed.
S & F Sub Main Wiring with PVC Insulated multistranded copper conductor wires with 4 x16.0 sq. mm+ 2x10.0 sq.mm earth wire including one run of suitable size casing and capping complete all as specified and directed.
Ditto all as per Ser Item No 141.00 above but with 50.0 sq. mm 3 core cable PVC Insulated multistranded copper conductor wires complete all as specified and directed.
Ditto all as per Ser Item No 141.00 above but with 2x10.0 sq. mm + 1x6.0 sq. mm earth wire complete all as specified and directed.
Ditto all as per Ser Item No 141.00 above but with 2x16.0 sq. mm + 1x10.0 sq. mm earth wire complete all as specified and directed.
M & L for Earthing complete with copper earth plate electrode 600 mm x 600 mm x 3.15 mm as earthing lead buried directly in ground vertically to a depth not less than 2.25 Mtr deep below ground level with top edge of the plate not less than 1.5 Mtr below normal ground level connected to and including copper strip 20 X 3 mm as earthing lead by means of bolts, nuts, check nuts & washers etc and connected to earthing test point all as shown in electrical plate No. 5 of SSR Part I of 2009 & as specified or indicated and testing on completion including excavation/earth work in any type of strata PCC ( 1:3:6 ) type C1 earthing chamber, pre cast slab cover 50 mm thick in cement concrete ( 1: 2 : 4 ) type B 1 ( reinforced with welded steel wire fabric (XPM) weight not less than 4 Kg / Sqm), funnel with wire mesh, watering pipe of 20 mm bore medium grade, including copper strip 20 x 3 mm with GI protection pipe of 40 mm medium grade up to 7.5 meter length, etc complete all as specified and directed.
M&L for providing earthing complete with galvanised iron earth plate electrode 600 mm x 600 mm x 6mm as earthing lead buried directly in ground vertically to a depth not less than 2.25 Mtr deep below ground level with top edge of the plate not less than 1.5 Mtr below normal ground level connected to and including galvanised GI wire 4 mm as earthing lead by means of bolts, nuts, check nuts & washers etc made of GI and connected to earthing test point, providing charcoal and common salt all as shown in electrical plate No. 5 of SSR Part I of 2009 & as specified or indicated and testing on completion including exaction/earth work in any type of strata PCC (1:3:6) type C1 earthing chamber, pre cast slab 50 mm thick in cement concrete (1:2:4) type B1 (reinforced with welded steel wire fabric (XPM) weight not less than 4 Kg/sqm), funnel with wire mesh, watering pipe of 20 mm bore medium grade and lugs, including galvanised iron strip wire 4 mm with GI protection pipe of 20 mm medium grade 7.5 meter long, etc complete all as specified and directed. (i) Excavated material to be removed from the site and deposit at the distance not exceeding 50m distance and levelled. (ii) Refill the pit with M&L for black cotton soil 1 cum.
S & F Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe orfixed to poles or any other indicated situation for loop earthing etc. as required Copper 20x 3 mm incl S & F DMC porcelain insulators of size 20x3 mm T type with nut bolts,washers / screws for fixing of copper strips on walls / roof etc complete all as specified and directed.
M& L for wiring complete with 1.5 sqmm single core multistanded copper conductor FRLS PVC insulated and unsheathed cable 1100V grade conforming to IS 694 drawn through steel ERW conduit of 25mm ( external) flame proof, heavy grade ISI marked including necessary conduit accessories surface on wall , ceiling etc. including sunken type pressed steel terminal boxes with phinolic laminated sheet of approved shade 3mm thick including 1.5mm PVC insulated flame retardent copper conductor as in continous earth wire for One FP light point controlled by one way metal clad switch complete all as specified and directed.
Supply and fix Switch flame proof rotary type with termination box in LM6, 16A, single pole 250V complete all as specified and directed.
Supply and fixing LED light fitting 1x 40 Watt flame proof, CMRI certified recommended for gas/ vapor group of IIA & IIIB, Zone 1 & 2 and IP 65 protection with die cast aluminum housing with heat resistant toughened glass, with LED tube light fixtures driver, holders, connector etc. Complete with all accessories prewired and including connecting up with three core flexible copper conductor cable with suitable size complete all as specified and directed.
M& L for wiring complete with 2.5 sqmm single core multistanded copper conductor FRLS PVC insulated and unsheathed cable 1100V grade conforming to IS 694 drawn through steel ERW conduit of 25mm ( external) flame proof, heavy grade ISI marked including necessary conduit accessories surface on wall , ceiling etc. including sunken type pressed steel terminal boxes with phinolic laminated sheet of approved shade 3mm thick including 1.5mm PVC insulated flame retardent copper conductor as in continous earth wire for One FP Power point controlled by one way metal clad switch complete all as specified and directed.
S & F Flame proof switch socket & plug combined in LM6 cable termination box in LM6, 16A 250 V 2P + E complete all as specified and directed.
Supply, laying, jointing, testing and commissioning of LT under ground cable 1100 volts grade XLPE (cross linked polythene ) armoured with galvanised round steel wire or steel strip , electric power cable heavy duty, with multi stranded aluminium conductor, laid in trenches, ducts fix on walls/poles/and steel structure etc as required on site with proper size saddles and clamp laid under roads/path/ drain /colverts or enclosed in GI pipe/ fix complete all as specified and directed. for following size:- 10 Sq mm x 3 Core
M&L for providing earthing complete with galvanised iron earth plate electrode 600 mm x 600 mm x 6mm as earthing lead buried directly in ground vertically to a depth not less than 2.25 Mtr deep below ground level with top edge of the plate not less than 1.5 Mtr below normal ground level connected to and including galvanised GI wire 4 mm as earthing lead by means of bolts, nuts, check nuts & washers etc made of GI and connected to earthing test point, providing charcoal and common salt all as shown in electrical plate No. 5 of SSR Part I of 2009 & as specified or indicated and testing on completion including exaction/earth work in any type of strata PCC (1:3:6) type C1 earthing chamber, pre cast slab 50 mm thick in cement concrete (1:2:4) type B1 (reinforced with welded steel wire fabric (XPM) weight not less than 4 Kg/sqm), funnel with wire mesh, watering pipe of 20 mm bore medium grade and lugs, including galvanised iron strip wire 4 mm with GI protection pipe of 20 mm medium grade 7.5 meter long, etc complete all as specified and directed. (i) Excavated material to be removed from the site and deposit at the distance not exceeding 50m distance and levelled. (ii) Refill the pit with M&L for black cotton soil 1 cum. Note - On testing after completion if the desired earth resistance is not obtained the earthing will be redone at no extra cost
R K ENTERPRISES
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .