Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Tender Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹22.4 LAccepted-AOC | L1 | Accepted-AOC Lowest bid. | |
| 2 | L2₹22.7 L+₹27,111 (1.21%)Rejected-Finance | L2 | Rejected-Finance Other than lowest bid. | |
| 3 | L3₹24.6 L+₹2.2 L (9.80%)Rejected-Finance | L3 | Rejected-Finance Other than lowest bid. | |
| 4 | L4₹26.8 L+₹4.4 L (19.5%)Rejected-Finance | L4 | Rejected-Finance Other than lowest bid. | |
| 5 | L5₹27.0 L+₹4.6 L (20.3%)Rejected-Finance | L5 | Rejected-Finance Other than lowest bid. |
Tender Value
₹30 L
EMD Value
₹60,000
Closing Date
9 Sept 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE SOUTH MAMUN
GE SOUTH MAMUN PATHANKOT-145001
COMPREHENSIVE MAINT TO OTM ACCN OF AGE B/R-I OF GE (SOUTH) MAMUN
2023_MES_613505_1
GE(S)/M-29/2023-24
Open Tender
Miscellaneous Works
Item Rate
270 days
GE SOUTH MAMUN
AS PER NIT
8 documents required · 8 mandatory
₹500
GE SOUTH MAMUN
₹60,000
Yes
10 Oct 2023
12 Aug 2023
16 Sept 2023
12 Aug 2023
9 Sept 2023
26 Aug 2023
Amount
Demolition of brick or stone / concrete block / stone boulder masonry built in cement mortar including all quions, arches, pillars etc but excluding ashlar facings dressed stonework and pre cast concrete articles complete all as sepecified and directed.
Demolition of cement concrete (unreinforced) of any description and in any position not specifically provided for, complete all as specified and directed.
Taking down cement plaster on brick walls or stone walls or concrete surface any description etc including raking out joints, hacking for key, scrubbing down with water etc., complete all as specified and directed.
M&L for roughening surface of old concrete by picking, sweeping clean and washing down with water to remove all loose dust etc.and applying brushing neat cement slurry with 3.00 kg of cement per sqm, complete all as specified and directed.
Taking down, easing and adjusting shutters of any description, exceeding 1.00 Sqm but not exc 2.0 Sqm each and refixing in the same or other opening, complete all as specified and directed.
M&L for Brick work with fly ash bricks, old size bricks, straight or curved on plan exc 6 mtr mean radius built in CM (1:6) including complete all as specified and directed.
All as per item No. 6 above but except bricks complete all as specified and directed.
M&L for non skid ceramic coloured tiles 7 to 8mm thick, area of each tile exc 0.18 Sqm but not exc 0.38 Sqm as in floors etc, set and jointed (joint free) in neat cement slurry and pointed in coloured cement to match the shade of tile over and including 15mm thick screed bed or bedding layers in CM 1:6 for laying floor finishes, complete all as specified and directed.
M&L for non skid ceramic coloured tiles 7 to 8mm thick, area of each tile exc 0.18 Sqm but not exc 0.38 Sqm as in skirting, dado, verticle surfaces etc, set and jointed (joint free) in neat cement slurry and pointed in coloured cement to match the shade of tile over and including 10mm thick screed bed or bedding layers in CM 1:4 for laying floor finishes, complete all as specified and directed.
M&L for glazed ceramic coloured tiles of size 300mm x 450mm x 7mm thick on vertical surfaces, set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tile over and including rendering 10mm thick in CM 1:4 and finished rough to receive tiles complete all as specified and directed.
M&L for 10mm thick vitrified ceramic 'light shade' colour tile (Square or Rectangular), polished of size 600mm x 600mm as in floors etc, set and jointed in neat cement slurry and pointed in coloured cement to match the shade of tile over and including 15mm thick screed bed or bedding layers in CM 1:6 and finished rough, complete all as specified and directed.
M&L for 10mm thick vitrified ceramic 'light shade' colour tile (Square or Rectangular), polished, area of each tile not exc 0.36 Sqm as on vertical surfaces, set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tile over and including rendering 10mm thick in CM 1:4 and finished rough to receive tiles complete all as specified and directed.
M&L for 10mm thick vitrified ceramic 'light shade' colour tile (Square or Rectangular), polished, area of each tile exceeding 0.42 Sqm but n.exc 1.00 Sqm as in floors etc, set and jointed in neat cement slurry and pointed in coloured cement to match the shade of tile over and including 15mm thick screed bed or bedding layers in CM 1:6 and finished rough, complete all as specified and directed.
M&L for 10mm thick vitrified ceramic 'light shade' colour tile (Square or Rectangular), polished, area of each tile exc 0.42 Sqm but n.exc 1.00 Sqm as on vertical surfaces, set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tile over and including rendering 10mm thick in CM 1:4 and finished rough to receive tiles complete all as specified and directed.
M&L for marble work (Green / Black marble Bhaislana Zebra) 18-20mm thick (table rubbed and polished) as in cooking plateform, window cills, jambs, steps and like including pointing with white cement (1:2) using marble dust with admixture of pigment to match the marble shade including rounding the exposed edges full round, and making hole for gas pipe where required, over and including 15mm thick screed in CM 1:4 finished even and rough to receive top layer complete all as specified and directed.
M&L for machine cut kota stone slab flooring 18-20mm thick over and including 20mm thick (size not less than 55 x 55 Cms) screed bed in CM 1:6, laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing to yield mirror finish as in floors / cills etc, and moulding at edges if required complete all as specified and directed.
M&L for machine cut kota stone slab as in riser of skirting/dado etc of 16-18mm thick over and including 10mm thick rendering in CM 1:4, laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing to yield mirror finish as in floors / cills etc, and moulding at edges if required complete all as specified and directed.
M&L for 10mm thick rendering or plastering work in CM 1:3 on ceiling surfaces, finished the surface even and smooth without using extra cement complete all as specified and directed.
M&L for 10mm thick rendering or fair faces of brick work or concrete surfaces in CM 1:6 finished even and fair without using extra cement complete all as specified and directed.
M&L for 15mm thick rendering on brick work or concrete surfaces of wall, in CM 1:4 finished the surface even and smooth without using extra cement complete all as specified and directed.
Taking down cement plaster and decayed concrete of any description, upto tripple storey of building, from roof projection, chajja etc and making good the decayed portion with cement mortar 1:3 mixed with water proofing compound as per manufacturers instruction or PCC 1:2:4 type B-0 (using 12.5mm graded crushed stone aggregate ) including necessary form work and finally finished the surface with 15mm thick cement plaster in CM 1:3, complete all as specified and directed.
M&L for 75mm thick cement concrete 1:3:6, type C-1 (using 20mm graded crushed stone aggregate) as in plinth protection and paving, laid in slope, finished even and fair including making joints at every 2.5 mtr and at corner filled with bitumen 85/25 and sand in ratio 1:2 by weight complete all as specified and directed.
M&L for preparation of newly plastered surface of wall and applying two coats of oil emulsion distamper white or tinted shade over a coat of chalk whitening primer, complete all as specified and directed.
Complete removal of existing treatment of surface of wall and applying two coats of oil emulsion distamper white or tinted shade over a coat of chalk whitening primer, complete all as specified and directed.
M&L for preparation of newly plastered external surface of wall and applying two coats of cement base paint white tinted shade over a coat of alkali resistant primer including curing before and after paint, complete all as specified and directed.
Complete removal of existing treatment of external surface of wall and applying one coats of cement based paint white tinted shade over a coat of alkali resistant primer including curing before and after paint, complete all as specified and directed.
Material & Labour for applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces complete all as specified and directed.
M&L for preparation of newly plastered surface of ceiling and applying three coats of white wash, complete all as specified and directed.
M&L for preparation of old plastered surface of ceiling and applying one coat of white wash, complete all as specified and directed.
M&L for preparation of newly plastered surface of wall and applying three coats of white wash, complete all as specified and directed.
M&L for preparation of old plastered surface of wall and applying two coats of white wash, complete all as specified and directed.
M&L for preparation of new surfaces of steel & iron work of any description exc 10cm width or girth and applying two coat of synthetic enamel paint over a coat red oxide primer, complete all as specified and directed.
M&L for preparation of old surfaces of steel & iron work of any description exc 10cm width or girth and applying one coat of synthetic enamel paint, complete all as specified and directed.
M&L for preparation of old surfaces of wood & wooden of any description exc 10cm width or girth and applying one coat of synthetic enamel paint, complete all as specified and directed.
Dismantling of plain or corrugated asbestos cement (corrugated,semicorrugated, etc.) sheets in roof coverings complete all as specified and directed.
Dismantling structural steel work in- cluding doors, gates but excluding framed truss etc.complete all as specified and directed.
Dismantling timber scantlings 40 sq. cm and over in section, in any position complete all as sepecified and directed.
M&L for PCC 1:2:4, type B-1 (using 20mm graded crushed stone aggregates) as in coping, including weathering slightly rounded or chamfered angles and throating complete all as specified and directed.
M&L for Rolled sections as in main and cross beams, hip and jack rafters; purlins where connected to common rafters and running rails and guides for sliding doors; fixed with angle cleats or other connecting plates confirming to Fe-290 (Gde E-165) complete all as specified and directed.
S&F for Pre- painted galvatume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified complete all as specified and directed.
S&F for Pre- painted galvatume aluminum zinc coating GI based plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified complete all as specified and directed.
S&F 0.63mm thick plain, galvanised, mild steel sheeting, in ridges, hips, valley gutters, drip and straight flashings (length and girth as fixed) with grade of zinc coating 275 complete all as specified and directed.
S&F for 6mm thick non asbestos cement, corrugated or semi-corrugated sheets in roofs, walls etc.fixed with L-type or J-type or cranked hook bolts complete all as specified and directed.
All as per item 43 above but except asbestos cement, corrugated or semi corrugated sheets, complete all as specified and directed.
S&F false ceiling of 9.5mm thick gypsum tiles 600mmx600mm laminated with PVC film on the front face side and metalised polyester film on the back side with all four edges sealed with PVC film (shade either plain white or crack) fixed using T-grid/cross-T/wall angle/level clip & suspenders of standard galvanised sections in a grid size of 600mmx600mm including taking down existing ceiling board & grid work etc of any type/pattern complete all as specified and directed.
M&L in repair (short quantity) 4mm thick non asbestos fibre cement building boards fix to existing timber/GI/Aluminium framework with screws in ceiling with screws including preparation of new surface and applying three coats of white wash including taking down existing ceiling boards complete all as sepecified and directed.
S&F 5mm thick coloured/printed solid PVC sheet as in wall paneling/lining for fixing on brick masonry wall and solid PVC partitions inclusive of 5mm thick and 35mm wide vertical PVC beading fixed with machine screws with a horizontal spacing of 300mm centre to centre and arround of opening at site including demolition of existing lining of any description complete all as specified and directed.
M&L for 3mm thick PVC corner fillet on gola of width 35mm for wall paneling fixed to opening of door and window, complete all as specified and directed.
Disconnecting existing PVC tanks, setting aside (or lowering if required) for repair, cleaning and removing all scale and dirt by using bleaching powder from tank and from mouth of circulating pipe etc and hoisting if required reconnecting and refixing in position of capacity up to 500ltrs and making good for running of water from tank to inside of bldgs and letter writing of ''Date of cleaning and due on'' with synthetic enamel paint complete all as specified and directed. Note :- Bleaching powder shall be included in this items.
Disconnecting existing PVC tanks, setting aside (or lowering if required) for repair, cleaning and removing all scale and dirt by using bleaching powder from tank and from mouth of circulating pipe etc and hoisting if required reconnecting and refixing in position of capacity exceeding 500ltrs but n.exceeding 1000ltrs and making good for running of water from tank to inside of bldgs and letter writing of ''Date of cleaning and Due on'' with synthetic enamel paint complete all as specified and directed. Note :- Bleaching powder shall be included in this items.
S&F in repair 20mm bore Ball valves high pressure of PTMT with epoxy coated Aluminium rod & highdensity plastic ball screwed for iron pipe and fixed. (Minimum weight - 210 gms, complete all as specified and directed.
S&F in repair 20mm bore stop valves, cast(ISI marked) copper alloy,screwed down,high pressure, with crutch or butterfly handle,screwed both ends for iron pipe or for unions and fixed complete all as specified and directed.
Taking up or down 20mm bore steel tubing and connections, including cleaning for re-fixing the same steel tubing and connections in new or old position (Walls, ceiling, floors, etc.complete all as specified and directed.
S&F as in repair water tank cover, high pressure of plastic fitted to existing water tank complete all as specified and directed.
M/S TARA CHAND CONSTRUCTION CO.
M/s Ashoka Brothers
VOHRA CONSTRUCTION CO
AV ENTERPRISES
M/S BHOTO AND CO
Bidder Name
Abrol construction co
AV ENTERPRISES
M/S BHOTO AND CO
M/s Ashoka Brothers
M/S TARA CHAND CONSTRUCTION CO.
VOHRA CONSTRUCTION CO
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .