Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹13.5 LAccepted-AOC | L1 | Accepted-AOC admitted as L1 | |
| 2 | L2₹14.6 L+₹69,597 (5.00%)Rejected-Finance 1890 NEW SHOBHAPUR COLONY VEHICLE FACTORY ROAD JABALPUR MP 482009 | JABALPUR | MADHYA PRADESH | 482009 | L2 | Rejected-Finance OTHER THAN LOWEST BIDDER | |
| 3 | L3₹15.3 L+₹1.4 L (10.3%)Rejected-Finance HO SR NO 73 TAPKIR MALA CHOWK TAPKIR NAGAR KALEWADI PIMPRI PUNE 411017 | PUNE | MAHARASHTRA | 411017 | L3 | Rejected-Finance OTHER THAN LOWEST BIDDER | |
| 4 | L4₹16.0 L+₹2.1 L (14.9%)Rejected-Finance | L4 | Rejected-Finance OTHER THAN LOWEST BIDDER | |
| 5 | L5₹16.0 L+₹2.1 L (15.0%)Rejected-Finance | L5 | Rejected-Finance OTHER THAN LOWEST BIDDER |
Tender Value
₹17.5 L
EMD Value
₹35,000
Closing Date
6 Nov 2021, 6:00 pmClosed
CWE JABALPUR
CWE JABALPUR PB NO 54 SADAR JABALPUR 482001
Special repair to Old record room of the office building in PAO (ORs) Corps of Signal, Jabalpur under GE (East) Jabalpur
2021_MES_480936_1
82586/JBPE/E8
Open Tender
Civil Works
Item Rate
180 days
JABALPUR
AS PER NIT
9 documents required · 9 mandatory
₹500
Yes
GE EAST JABALPUR
₹35,000
Yes
7 Dec 2021
9 Oct 2021
8 Nov 2021
9 Oct 2021
6 Nov 2021
23 Oct 2021
9 Oct 2021 - 23 Oct 2021
Amount
Basic Rate : Refer Schedule'A' Notes
Dismantling of plain or corrugated steel sheeting, any gauge, thickness, including Nainital or similar pattern roof covering and ridge complete all as specified and as directed.
S&F of pre-painted galvalume aluminium zinc coating GI based 0.50mm thick (AZ-150) corrugated steel sheet (TCT) of any colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall, fixed with self tapping screws/ L or J type or cranked hook/ bolts complete all as specified & directed. Make: Tata Bule Scope Steel Ltd or M/S Cril Colour Roof India Ltd. or equivalent brand of other Make as approved by GE from list of make attached with tender documents.
M&L for PCC 1:2:4 type B-0 using 12.50mm graded crushed stone aggregate as in bed block for hold fast, plinth courses, copings, benching, bed plates etc and the like including weathering slightly rounded/ chamfered angles with & including necessary use and waste of form work for fair faces of concrete, complete all as specified and directed.
Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as specified and directed.
Supply and fix rolled mild steel sections conforming to Fe- 410-W (Gde E-250) quality-A as in main and cross beams, hip and jack rafters; purlins where connected to common rafters and running rails & guides for sliding doors, fixed with angle cleats or other connecting plates etc complete all as specified & directed.
M&L for mild steel work conforming to Fe-290 Gde -165 as in nosing to steps including embeding in concrete and screwing etc, wind ties for roof including securing bolts, posts & struts in fencing including cutting top to shape as directed, drilling holes, notching for wire, etc; flat iron fillets (for securing wire mesh etc) including all necessary drilling, bolting or riveting etc complete all as specified and directed.
Dismantling wall and ceiling boards (fibre, pulp, insulation, etc.) or insulation boards/ slabs/ blankets, any thickness, including cover fillets complete all as specified and as directed..
M&L for mils steel galvanised powder coated T-grid frame work of make as approved by GE for suspended false ceiling with size of grid 600 x 600mm consisting of main tee/ runner of size 35 x 25 x 1.3 mm, cross tee of size 25 x 25 x 1.3 mm and wall angle of size 25 x 25x 1.5 mm suspended @ 1.2M c/c both way with and including 4mm dia GI wire with J hook, nuts/bolts, butterfly clips, soffit cleat/ rawl plug etc as per manufacturer's instructions and 8mm thick pre-primed, self embossed, textured designer, water & termite resistant calcium silicate boards for insulation complete all as specified and directed. Make: Armstrong or Ramco Industries or equivalent brand of other Make as approved by GE from list of makes attached with tender documents.
Demolition of cement concrete of any description (unreinforced) in ground floors and paving not exceeding 15 cms thickness (below or above ground level) including removal of debris to out side MD land complete all as specified & directed.
M&L for 25mm thick cement concrete type B0, 1:2:4 (using 12.50mm graded stone aggregate) in sub floors, sub-bases etc for receiving the toping layer finish the surface even & rough, complete all as specified and directed.
M&L for machine cut kota stone slab as in flooring, 18-20mm thick over & including 20mm thick cement screed bed in CM (1:6) laid and jointed with grey cement slurry mixed with pigment to match with the shade of the slab including rubbing and mirror polishing complete all as specified & directed.
M&L for machine cut kota stone slab as in skirting/ vertical surface, 18-20mm thick over & including 10mm thick rendering in CM (1:4) laid and jointed with grey cement slurry mixed with pigment to match with the shade of the slab including rubbing and mirror polishing complete all as specified & directed.
M&L for 75mm thick PCC 1:3:6 type C-2 using 40mm graded stone aggregate as in plinth protection finished even and smooth without using extra cement forming joints to full depth at every 3M intervals and at every change of direction and filing with bitumen sand mixture 1:3 by weight complete all as specified and directed.
M&L for Pre cast PCC 1:2:4 type B-1 using 20mm graded stone aggregate as in bed block for hold fast, plinth courses, copings, bending, bed plates etc and the like including weathering slightly rounded/ chamfered angles with & including necessary use and waste of form work for fair faces of concrete, complete all as specified and directed.
M&L for 60mm thick rubber mould reflective factory made coloured pre cast PCC interlocking paver blocks/ tiles conforming to IS 15658-2006, M-35 designation of section as approved by GE in hard standing, laid dry over & including 50mm thick sand cushion and filling the voids of paver blocks/tiles with dry sand complete all as specified & directed. Make:- Mehtab Tiles, Indore (MP) or Nitco, Mumbai or Mayur Tiles & Interlocking pavers, Lucknow or Star Tiles & Industries, Ramadevi, Kanpur as approved by GE.
M&L for 75mm thick PCC 1:4:8 type D-2 using 40mm graded stone aggregate complete all as specified and directed.
Demolition of brick work or stone/ boulder masonry, built in cement mortar or cement lime mortar including all quoins, arches, pillars etc but excluding ashlar facings, dressed stone work and pre-cast concrete articles complete all as specified and directed.
M&L for brick work with sub class 'B' old size fly ash bricks, straight or curved on plan exc 6m mean radius built in CM (1:6) complete all as specified & directed.
M&L for brick work with sub class 'B' old size bricks, straight or curved on plan exc 6m mean radius built in CM (1:6) but except bricks complete all as specified & directed. Note:- Old bricks as obtained from "demolition of brick work" here-in-before shall be used after cleaning & stacking and quoted rate shall be deemed to be inclusive of these provisions also.
Taking down cement plaster etc on brick walls/ concrete (ceiling) surfaces of any descriptions including racking out joints, hacking for keys, scrubbing down with water and disposal of unserviceable materials to out side of MD land complete all as specified & directed.
M&L for 15mm thick rendering in two layers, first layer 10mm thick in CM 1:6 and other finishing layer 5mm thick in CM 1:4 with and including integral liquid water proofing compound @ 3% by wt of cement or as per manufacturer's instructions on fair faces of brick work or concrete surfaces, finished even and smooth without using extra cement complete all as specified & directed. NOTE:- WPC shall be measured and paid seoarately
M&L for 15mm thick rendering in CM 1:6 on fair faces of brick work or concrete surfaces, finished even and smooth without using extra cement complete all as specified & directed.
M&L for 10mm thick rendering in CM 1:3 on fair faces of brick work or concrete surfaces, finished even and smooth without using extra cement complete all as specified & directed.
Supply only Integral liquid water proofing compound of make as approved by GE complete all as specified & directed.
M&L for preparation of newly plastered surfaces on wall and apply 1mm thick of Birla/ JK wall care putty for smooth finish of wall complete all as specified and directed.
M&L for prepration of old decorated plastered or unplastered surfaces of walls of any description by complete removal of existing treatment and preparation of surfaces for further treatment and applying two coats of distemper, oil emulsion white or tinted complete all as specified and directed.
M&L for prepration of new plastered surfaces of walls and applying two coats of cement base paint over & including a coat of appropriate primer complete all as specified & directed.
Taking down Chowkhats or frame with shutter (w/o taking off shutter from the frame) area n.exc 1.50 sqm each and removal complete all as specified & directed.
Taking down Chowkhats or frame with shutter (w/o taking off shutter from the frame) area exc 1.50 sqm but n.exc 4 sqm each and removal complete all as specified & directed.
S&F framed work as in iron enclosure, doors or gate of angle iron or other section with gusset plate, rails, braces etc drilled for fixing of steel seating other covering, door etc to be prepared for hanging or sliding with and including either hooks and hinges or steel handing door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging, also fastening and fixing conforming to Fe-290 (Gde-E-165) complete all as specified and as directed. Note: The unit rate quoted by contractor is deemed to be inclusive of cutting to dead lenth where required, notching, drilling, fitting, rivetting and/or welding or connecting with bolts and nuts (including rivets or bolt and nuts), providing and fiitings angle cleats, fish plates, gusset plate etc., also for welding plumbing, truing up and fixing complete. No claim whatso ever shall be entertained by Govt on this account.
M&L for Plates (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes, without any attachment Fe-410-W Gde- E-250 quality-A complete all as specified and directed.
Supply and fix factory made pre-coated steel windows/ ventilators flash butt welded with side hung shutters including box type hinges with pre-coated handles, pre-coated tower bolts, pre-coated steel peg stay 250mm long with suitable lugs and with glazing bars dovetailed or welded with and including provision of guard bars complete all as specified and as directed. Notes: (i) For construction details, TD drawing No. CEJZ/TD/980 Sheet 1/2 & 2/2 shall be followed. (ii) Wiremesh/ glass panes shall be measured and paid separately in "supply only" under respective items of BOQ.
Supply and fix factory made pre-coated steel windows/ ventilators flush butt welded with side hung shutters including box type hinges with pre-coated handles, pre-coated tower bolts, pre-coated steel peg stay 250mm long with suitable lugs and without glazing bars complete all as specified and as directed.complete all as specified & directed. Notes: (i) For construction details, TD drawing No. CEJZ/TD/980 Sheet 1/2 & 2/2 shall be followed. (ii) Wiremesh/ glass panes shall be measured and paid for separately in "supply only" under respective items of BOQ.
M&L for mild steel conforming to Fe.290.Gde-E-165 in framed work such as grills, gratings, etc with ends of bars shouldered and/or riveted or forged into spikes; framed guard bars; ladders; railings and similar work complete all as specified & directed.
M&L for hold fast made out of flat iron of suitable section conforming to Fe.290.Gde-E-165 complete all as specified & directed.
S&F in repairs, stainless steel wire cloth, 0.36mm nominal dia of wire and average width of aperture 1.40 mm and fixed with stainless steel wire staples or any other means as per site requirement complete all as specified & directed.
S&F sheet glass, ordinary quality 3.0mm thick and glazing with oil putty/ beads in squares n. exc 0.5sqm in each pane complete all as specified & directed. Notes:- (i) Glazing in old work, serviceable beads as obtained from hacking out of sheet glass shall be re-used after cleaning/ rubbing the the same with sand paper, if required as per site. (ii) Glazing in new work, beads shall be supplied with joinery.
Supply & fix 300mm long aluminium alloy, anodised sliding door bolts with hasp & staple (bolt type) & fixing clips of sheet, cast or extruded section and fixing bolts & sliding bolts of extruded section or cast aluminium alloy complete all as specified & directed.
Supply & fix 100mm size butt hinges, medium weight, cold rolled mild steel complete all as specified and directed.
Supply and fix aluminium handles 150mm size, cast type, anodised complete all as specified & directed.
Supply and fix 200mm long aluminium anodised barrel tower bolts of extruded section complete all as specified & directed.
M&L for preparation of new surfaces of iron/ steel of any description over 10 cm width or girth and applying two coat of synthetic enamel paint of colour as approved by GE over and including a coat of red-oxide primer complete all as specified & directed.
M & L for preparation of surface including cleaning drying and removing all oil, grease, dust etc and priming the surface with a coat of Dr fixit primeseal apply at the rate of 8-10 Sqm/Ltr and applying two coats of Dr. fixit Hydroshield PUD plus by brush or roller to achieve a total depth of 0.8-1 mm with coverage of approximately 0.60 Litre/Sqm per coat. Note: (i) The contents of Dr fixit Hydroshield PUD plus shall be throughly stirred for atleast 2-3 minutes using a slow speed (300-400 RPM) drill machine attached with a mixing paddle. Do not dilute with water keep on stirring during application. (ii) All joints corners/drainage outlets and penetration points shall be treated prior to application of Dr fixit Hydroshield PUD plus. All corners gaps joints protrusions and outlets should be coated with an extra coat incorporating reinforceing fabric. (iii) Allow complete drying between coats with a minimum 3 to 4 hours depending on the weather conditions.
Taking down carefully copper/aluminium point wiring on batten/ PVC conduit (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, sockets, light fittings etc, including removal and making good disturbed surfaces of walls, ceilings etc as per existing complete all as specified & directed.
Taking down unservicable/partly unservicable street light/ light fittings any type, tube light fitting and fixtures, etc, and making good to the disturbed surfaces of walls/ floor etc to macth with existing surfaces including white washing/ colour washing/ distempering to match with existing wall/ floor/ ceiling finishes complete all as specified & directed.
Taking down main switches/ DB's (alongwith existing board, MCBs & isolators) including removing the same from site and making good disturbed surfaces complete all as specified & directed.
Taking down existing old/ unserviceable sub main wiring of any type and description, removal of teak wood batten/ PVC pipe/ PVC casing & caping and making good disturbed surfaces of walls, ceilings etc as per existing complete all as specified and directed.
M&L for point wiring concealed type with 1.50sqmm PVC insulated, unsheathed, single core, multistranded copper conductor FRLS cable 1100 volts grade including 1.5sqmm PVC insulated unsheathed multistranded copper copper conductor FRLS cable as earth continuity conductor drawn through in and including rigid PVC conduit not less than 20mm dia with its accessories, sunken type pressed steel terminal box made of 1.2mm thick MS sheet/ anodised steel box painted with one coat of red oxide primer including 3.0mm thick ISI marked laminated/ ebonite sheet cover for fixing switches/ socket/ regulators etc including all fixing accessories and cutting chases as per standard engineering practice & making good the disturbed surfaces as per existing finish for the one light/ fan/ exhaust fan/ bell point controlled by one no one way piano type switch 5/6 Amps complete all as specified & directed.
M&L for point wiring concealed type with 1.50sqmm PVC insulated, unsheathed, single core, multistranded copper conductor FRLS cable 1100 volts grade including 1.5sqmm PVC insulated unsheathed multistranded copper conductor FRLS cable as earth continuity conductor drawn through in and including rigid PVC conduit not less than 20mm dia with its accessories, sunken type pressed steel terminal box made of 1.2mm thick MS sheet/ anodised steel box painted with one coat of red oxide primer including 3.0mm thick ISI marked laminated/ ebonite sheet cover for fixing switches/ socket/regulators etc including all fixing accessories and cutting chases as per standard engineering practice & making good the disturbed surfaces as per existing finish for the one socket out let 3/5 pin, 5/6 Amps controlled by one no one way piano type switch on the same board with other switches complete all as specified & directed.
M&L for point wiring concealed type with 1.50sqmm PVC insulated, unsheathed, single core, multistranded copper conductor FRLS cable 1100 volts grade including 1.5sqmm PVC insulated unsheathed multistranded copper conductor FRLS cable as earth continuity conductor drawn through in and including rigid PVC conduit not less than 20mm dia with its accessories, sunken type pressed steel terminal box made of 1.2mm thick MS sheet/ anodised steel box painted with one coat of red oxide primer including 3.0mm thick ISI marked laminated/ ebonite sheet cover for fixing switches/ socket/regulators etc including all fixing accessories and cutting chases as per standard engineering practice & making good the disturbed surfaces as per existing finish for the one socket out let 3/5 pin, 5/6 Amps controlled by one no one way piano type switch on independent board but not below the switch board of light points in same vertical plane complete all as specified & directed.
M&L for point wiring concealed type with 2.50sqmm PVC insulated, unsheathed, single core, multistranded copper conductor FRLS cable 1100 volts grade including 1.5sqmm PVC insulated unsheathed multistranded copper conductor FRLS cable as earth continuity conductor drawn through in and including rigid PVC conduit not less than 20mm dia with its accessories, sunken type pressed steel terminal box made of 1.2mm thick MS sheet/ anodised steel box painted with one coat of red oxide primer including 3.0mm thick ISI marked laminated/ ebonite sheet cover for fixing switches/ socket/regulators etc including all fixing accessories and cutting chases as per standard engineering practice & making good the disturbed surfaces as per existing finish for the one socket out let 3/6 pin, 15/16 Amps controlled by one no, one way piano type switch on independent board complete all as specified & directed.
Supply & fix switch piano, flush type single pole, one way 5/6 Amps, 240 volts complete all as specified & directed.
Supply & fix bell push, single pole one way 5/6 Amps, 240 volts complete all as specified & directed.
Supply & fix socket outlet 2 in 1, 2 pin 5/6 Amps and 3 pin 5/6 Amps, flush universal type complete all as specified & directed.
Supply & fix switch socket combination 2 in 1, 2/3 pin, 5/6 Amps shuttered flush type multipurpose controlled by one switch complete all as specified & directed.
Supply & fix switch socket combination 2 in 1, 3 pins 5/6 Amps and 3 pins 15/16 Amps flush universal type controlled by one switch complete all as specified & directed.
Supply & fix ceiling rose, surface bakelite, 65x50mm surface type, two to three terminals, AC 240 volts complete all as specified & directed.
Supply & fix in repairs, rotory stepped type electronic fan regulator mini flush type 100W, 240 Volts-50Hz complete all as specified & directed.
Supply and fix in repairs, angle type lamp holder insulated with polycarbonate body and back plate housed with porcelain base suitable for 7 Watt LED lamp with and including 7 Watt LED bulb complete all as specified and directed. Makes: (i) Anchor/ Plaza/Equivalent for lamp holder as approved by GE. (ii) Crompton ,Philips ,Havells ,WIPRO ,Bajaj or equivalent as approved by GE for 7 Watt LED bulb.
M&L for provision of sub main wiring with two runs of single core FRLS PVC insulated, unsheathed, mutistranded copper conductor cable of size 6.0 sqmm drawn in and including rigid PVC conduit medium grade ISI marked not less than 20mm dia with its accessories, concealed type, including one run of single core FRLS PVC insulated, unsheathed, multistranded copper conductor cable of size 4.0sqmm as earth continuity and cutting chases as per standard engineering practice & making good the disturbed surfaces as per existing finish complete all as specified & directed. Notes:- (i) Finished sub main wiring with two runs of 6.0 sqmm cable & one run of 4.0 sqmm cable alongwith PVC conduit and its accessories shall be measured and paid one unit length. (ii) Connections of cables with MCBs or bus bars shall be done through appropriate size brass/ copper thimbles. (iii) Colour coding for wiring/ bus bar/ main connection shall be followed .
Supply and fix TPN DB-VPTN 4 way sheet metal enclosure triple pole and neutral, IP 43-IK 09 with metal door, 415 volts with copper bus bar of 250A for each phase and with 2 neutral bar, 2 earthbar and cable ties for cable management all enclosed on standard steel sheet flush or surface mouting type factory fabricated complete all as specified and directed . Make:- Legrand Cat No. 5077 45 or equivalent model of make L&T/ Havells/ ABB as approved by GE.
Supply and fix SPN DB 8 way sheet metal enclosure, IP 43-IK 09 with metal door, 240/ 415 volts with copper bus bar of 100A and neutral bar, earth bar and cable ties for cable management all enclosed on standard steel sheet flush or surface mouting type factory fabricated complete all as specified and directed. Make:- Legrand Cat No. 5076 11 or equivalent model of make L&T/ Havells/ ABB as approved by GE.
Supply & fix single pole and neutral sheet metal enclosure (AC box) with a two pin & earth plug and socket with one no. MCB SP of capacity 20 Amps, 10 kA, 240 volts complete all as specified & directed. Earth plug socket Cat Part No. 5078 11 of Legrand Make:- Legrand/ Siemens/ L&T/ Schneider as approved by GE.
Supply & fix MCCB , 100 Amps, 415 volts, 50Hz, 25kA, four pole complete all as specified & directed. Make:- Legrand Cat No. 4200 55 or equivalent model of make L&T/ Havells/ ABB as approved by GE.
Supply & fix MCB SPN, 32 Amps, 'C' series, 240 volts, 50Hz, 10kA complete all as specified & directed. Make:- Legrand Cat No. 4086 17 or equivalent model of make L&T/ Havells/ ABB as approved by GE.
Supply & fix MCB SP, 6 to 32 Amps, 'C' series, 240 volts, 50Hz, 10kA complete all as specified & directed. Make:- ABB/ Legrand/ Siemens/ L&T/ Havells as approved by GE.
Taking down of existing exhaust/ ceiling fan of any size/ sweep for keeping the safe cosdoy and re-fixing/ re-hanging the same after repair work or as directed and connecting up the same with & including twin twisted copper flexible wire from ceiling rose to exhaust/ ceiling fan complete all as specified & directed.
Supply and fix in repairs, 20 watt new generation energy saving and environmental friendly long life LED security light made up of pressure die cast aluminium housing with high power LED as lighting source and lens embedded PC cover having TOP opening seperate driver compartment with IP65 protection and impact resistance of IK07 on bldg wall with and including pipe bracket made out of G.I tubing 32/40 mm dia bore medium grade ISI marked 1.20m long bent to shape & providing clamps 2 Nos made out of 50 x 6mm Flat iron/ MS clamps & 12mm dia bolts, nuts & washers etc and two coat painting of approved colour on brackets completely with and including synthetic enamel paint and connecting up with & including twin twisted copper flexible wire from ceiling rose to fittings complete all as specified & directed. Make:- Havells Cat part No. ENDURAPEARLSL20WLED757SASYTOPCMP or equivalent model of make- Philips or Crompton or WIPRO or Bajaj as approved by GE.
M&L for earthing complete with galvansided steel earth plate electrode 600x600x6.0mm thick directly burried in the ground (earth pit not less than 2.25M deep below ground level) with top edge of earth plate not less than 1.50M deep below normal ground level, connected to galvanised iron wire 4mm by means of bolts, nuts, check nuts and washers of galvanised iron or steel, 15mm bore GI pipe medium grade including necessary fittings for protection of earthing wire, watering pipe 20mm bore GI medium grade, concrete chamber in PCC (1:4:8) type D-2 using 40 mm grade aggregate, coping shall be in PCC (1:3:6) type C-1 using 20 mm grade aggregate and internal surfaces of concrete chamber shall be given 12mm thick plaster in CM (1:4), funnel with wire gauge of 22 gauge (0.63 mm) 8 mesh per linear including 50mm thick cover of RCC (1:2:4) type B-1 using 20mm grade stone aggregate reinforced with 8mm MS deformed bar @ 75 mm C/C both ways, char coal dust and common salt all as shown in electrical plate No. 3 of SSR Part-I (2009) including all necessary excavation & earth work and removal of surplus soil to a distance n. exc 50M and providing connection points with MS/ GI bolts & washers as required and connection from earth test point to earth electrode with same GI earth wire alongwith protection pipe and testing on completion complete all as specified and directed. Note:- GI wire and protection pipe from earth electrode to test point max upto 7.50M shall be deemed to be included in the unit rates as quoted by the contractor.
Supply & fix LED security light fitting of 10/15W, with high power LED & LED driver with and including bracket made of G.I tubing 25 mm dia bore medium grade ISI marked 0.90m long bent to shape & providing clamps 2 Nos made out of 30 x 5 mm Flat iron/ MS clamps & 12mm dia bolts, nuts & washers etc including painting to all and including taking down unserviceable old street light and bracket complete all as specified & directed. Make:- Havells Cat No. ENDURAPEARLSL15WLED757SASYTOPCMP or equivalent model of make L&T/ C&S/ ABB as approved by GE.
Schedule of credit amount of Rs. 37,215.00 to be deducted during AOC
M/S A K MUKHERJEE
Goodluck Enterprises
JITENDER SINGH
NEERAJ DUBEY
M/s Ram Associates
LAL SINGH & SONS
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .