EE
DELHI JAL BOARD MU BLOCK, PITAMPURA, DELHI-34
Repairing of panels with allied works at various Tube Wells in AC 16
2025_DJB_273190_2
NIT No. 04(2025-26)M-6
Open Tender
Miscellaneous Works
Item Rate
30 days
EE ENM M VI
Please refer Tender documents.
3 documents required · 3 mandatory
₹500
Account No 50448339804
₹10,000
Yes
16 Jun 2025
31 May 2025
9 Jun 2025
31 May 2025
9 Jun 2025
31 May 2025
Dismantling of old and damaged MCCB, MCCBs, relay, Meters, contactors, etc. from the panel from the site after disconnecting their connections from the incoming and outgoing to the pump and also dismantle of cubical panel from the wall after removing fastener with the help of manual labour to carry out the work.
Replacement of MCCB triple pole of rating 63 Ampere, breaking capacity 25 kA or more Make:-L&T/BCH/Havells/C&S/HPL/Approved by DJB
Supply of power contactor, triple pole of rating 25 Ampere 415V AC Make:-L&T/BCH/Schneider
Supply of ADD on Blocks 1NO + 1NC for above contactors Make:-L&T/BCH/Schneider
Supply of supply monitoring type includes Single Phasing Preventor (SPP) Fail Safe Type having time ON Delay 2 sec and OFF Delay 7 sec Make: L&T/Schenider/BCH/approved make by DJB
Supply of Timer for star Delta 415V Make:-L&T/BCH/Schneider
Lifting & Lowering of sub pump set along with all allied accessories from T/wells ice dismantling of column pipe by opening/cutting of nut and bolts as required, opening and rejointing of cabies Testing commissioning of T/wells after lowering as per site requirement. The work including all arrangement of man and tools tackles such as tripod, chain, pulley pipe wrench etc.
Supply of three core flat cable with bare bunched copper conductor insulated & sheathed with PVC for submersible pump motor with voltage grade upto 1100V of 6.0 sq mm. size in 100mtr. Roll. Make Makegrandley/Havells/as approved by djb
Replacement of 3.5x35 sq. mm PVC insulated & PVC sheathed Aluminum armored conductor cable confirming to IS: 1554 from energy meter to panel complete or as required. Make: Make: - Gloster, Grandlay, Havells, Plaza, ICC, ICL, Universal & CCI. HSN 8544
Supply of C curves 32 Amp Four Pole MCB. Make :- Havells / Siemens/ L&T/ Legrand / Hager/ Newton
Supply of rotary switch for local/remote /auto-manual switch for panel .Make :- Havells / Siemens/ L&T
Replacement of main MCCB triple pole of rating 100 Ampere, breaking capacity 25 kA or more Make:-L&T/BCH/Havells/C&S/HPL/Approved by DJB
Replacement Changeover Switch Fuse Unit 4 Pole with rewireable fuse with current capacity 100 Amp, 415 volt, 50 Hz. Make L&T / Havells / HPL / BCH / C&S
Supply of Indicating Light LED type for panel Make:-L&T/BCH/Schneider
24 Hour Timer/ time switch Quartz type Make:-L&T/BCH/Schneider
Supply of Push buttons Make:-L&T/BCH/Schneider
Supply of Over load relay suitable for 7.5 HP/10 HP motor/pump Make:-L&T/BCH/Schneider
Supply of rotary switch for phase changeover for 32 Ampere .Make :- Havells / Siemens/ L&T
Supply of voltage monitoring relay series having operation of Phase Loss + Phase Sequence + Under Voltage + Over Voltage monitoring Make: L&T/ Havells /HPL/ any approved by DJB
Supply of Digital Ammeter for Three Phase supply Size 96X96 mm Make: - Trinity, Sigma, Conzerv, AE, L&T, Legrand or any approved by DJB
Supply of Digital Volt meter for Three Phase supply Size 96X96 mm Make: - Trinity, Sigma, Conzerv, AE, L&T, Legrand or any approved by DJB
Fixing of starter panel with help of fasteners/nut bolts etc. and Making incoming connections to the starter panel by the existing or by new copper cable as per site requirement including making end terminations etc. as per site requirement
Painting the complete panel in all respect with one coat of red oxide primer and two coats of anti corrosive powder coating/ paint including arrangement of standby panel if required at site as per direction of site in-charge during execution of work.
Installation and testing of new MCB, MCCB, relay, RCCB & digital ammeter & voltmeter etc. with the help of mechanical tool & tackels, making end terminations with the help of thimbles as per site requirement , copper flexible wire etc. This job also includes of manual man power, loading & unloading of men & material at site.
M G Traders and Engineers (BID ID -1588909)
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .